You are on page 1of 1

Capacities of Diaphragm Meters at Pressure

(in scf/h of 0.6 SG Natural Gas)


Differential New Meters Discontinued: Rebuilds may be available
Gauge Pressure Elster Sensus Elster Sensus Elster Sensus Elster Sensus Sensus Elster Elster
Pressure ("WC)
(psi) R-275 415
AC250 AL 425 AC 630 AL 1000 RC 750 AL 800 RC 1600 RC1000 AL 1400 AL 2300
MR-8 MR12
0.25 0.5 250 275 425 415 630 1000 750 800 800 1000 1400 2300
0.25 1 355** 383** 583** 577** 860** 1400** 1033** 1100** 1067** 1400** 1933** 3200**
0.25 2 565 600 898 900 1320 2200 1600 1700 1600 2200 3000 5000
2 2 600 635 955 952 1390 2400 1688** 1850 1688** 2321** 3265 5440
5 2 656 690 1038 1035 1515 2700 1840 2100 1840 2530 3700 6200
10 2 - - 1154 1160 1710 3400 2080 2600 2080 2860 4600 7700
20 2 - - 1367* 1377* 2010 4100 2480 3200 2480 3410 5600 9400
25 2 - - 1462* 1473* 2160 4600 - 3500* 2640 3630 6200 10400
50 2 - - - - - 6600* - 5100* 3360 - 9000 15000
75 2 - - - - - 8540* - 6600* 3920** - 11650 19400
100 2 - - - - - 10100* - 7800* 4480 - 13800 23000

Notes:
* Multiple options exist for MAOP, insure meter is rated for pressure
** These values have been interpolated and are estimates
For Propane capacities multiply Gas capacities by 0.63
For BTU flow rates assume 1000 BTU/scf Gas or 2500 BTU/scf Propane
For 200 series, we recommend using 0.5" differenetial capacities to ensure long-life performance

Although every effort has been made to insure the above data and calculations are accurate,
Barchard Engineering Ltd. assumes no liability or offers any guarantees for customer's use of this document.