You are on page 1of 106

TA B L E O F C O N T E N T S

To go directly to a TDS, click on the product name / application.


To return to this page, click on the LIMCO logo on any TDS.
Application Standard Preparation for Plastic Parts
P ro c e d u re s Standard Preparation for Steel, Aluminum & Galvanized Metals
Standard Preparation for OEM and Cured Finishes
Supreme PLUS Basecoat Blending Procedure - U.S. National Rule VOC
Supreme PLUS Basecoat Blending Procedure - Low VOC Recommendation

U n d e rc o a t s 800K 2K Primer Surfacer - U.S. National Rule Primer Surfacer Application with LH810, LH820
800K 2K Primer Surfacer - U.S. National Rule Primer Surfacer Application with LHF, LHM, LHS
800K 2K Primer Surfacer - U.S. National Rule Tinted Wet-On-Wet Sealer Application with LHF,
LHM, LHS
800K 2K Primer Surfacer - U.S. National Rule Tinted Wet-On-Wet Sealer Application with LHF,
LHM, LHS - MEXICO ONLY
846 1K Acrylic Primer - U.S. National Rule Primer Application
H1000 1K Waterborne Primer - Low VOC Primer Surfacer Application
LP20 Epoxy Primer - U.S. National Rule Primer Application
LP20 Epoxy Primer - Low VOC Primer Application
LP20 Epoxy Primer - U.S. National Rule Primer Surfacer Application
LP20 Epoxy Primer - Low VOC Primer Surfacer Application
LP20 Epoxy Primer - Wet-On-Wet Sealer Application
LP20 Epoxy Primer - Low VOC Wet-On-Wet Sealer Application
LP100 Etch Primer - U.S. National Rule Primer Application
LP100 Etch Primer - Low VOC Primer Application
LP610 Low VOC Primer - Low VOC Primer Surfacer Application
LP610 Low VOC Primer - Low VOC Sealer Application
LP620 Low VOC Primer - U.S. National Rule Primer Surfacer Application
LP620 Low VOC Primer - Low VOC Primer Surfacer Application
LP620 Low VOC Primer - U.S. National Rule Sealer Application
LP620 Low VOC Primer - Low VOC Sealer Application
LS56 1K Sealer - U.S. National Rule Wet-On-Wet Sealer Application
LS800 2K Sealer - U.S. National Rule Wet-On-Wet Sealer Application
PS21nr 1K Gray Sealer - U.S. National Rule Wet-On-Wet Sealer Application

To p c o a t s Supreme PLUS Acrylic 1K Single Stage - U.S. National Rule VOC


Supreme PLUS Low VOC Acrylic 1K Single Stage - 340 gms/liter (2.8 lbs/gal) VOC
420 gms/liter (3.5 lbs/gal) VOC
Supreme PLUS Acrylic 2K Single Stage - U.S. National Rule VOC
Supreme PLUS Low VOC Acrylic 2K Single Stage - 340 gms/liter (2.8 lbs/gal) VOC
420 gms/liter (3.5 lbs/gal) VOC
Supreme PLUS Urethane Single Stage with LA2799 - U.S. National Rule VOC
Supreme PLUS Urethane Single Stage with LA2999 - U.S. National Rule VOC
Supreme PLUS Low VOC Urethane Single Stage with LA2799 - 340 gms/liter (2.8 lbs/gal) VOC
Supreme PLUS Low VOC Urethane Single Stage with LA2799 - 420 gms/liter (3.5 lbs/gal) VOC
Supreme PLUS Low VOC Urethane Single Stage with LA2899 - 340 gms/liter (2.8 lbs/gal) VOC
420 gms/liter (3.5 lbs/gal) VOC
US. Rev. 1/3/18
AD2503L
To p c o a t s Supreme PLUS Basecoat - U.S. National Rule VOC
continued Supreme PLUS Low VOC Basecoat - 420 gms/liter (3.5 lbs/gal) VOC
Supreme PLUS 2K Direct-to-metal - U.S. National Rule VOC
Supreme PLUS 2K Direct-to-metal - 420 gms/liter (3.5 lbs/gal) VOC

C l e a rc o a t s LC4000 Clearcoat - U.S. National Rule VOC


LC4100 High Solids Clearcoat - U.S. National Rule VOC
LC4200 Low VOC Clearcoat - 250 gms/liter (2.1 lbs/gal) VOC
LC4300 European Style Clear - U.S. National Rule VOC
LC4400 Low VOC European Style Clear - 250 gms/liter (2.1 lbs/gal) VOC
LC4500 Express Clear - U.S. National Rule VOC
LC4800 Low 2.0 VOC Express Clear - 250 gms/liter (2.1 lbs/gal) VOC

Miscellaneous 892 Flex Agent


LE800 Fisheye Eliminator
LF01 Low VOC Flattener
LF10 Flattening Agent
Click on logo to return to Table of Contents

A P P L I C AT I O N P R O C E D U R E S

Standard Preparation
for Plastic Parts
General This system is used to repair damaged flexible or rigid plastic parts, or to refinish replacement plastic
parts.

Cleaning Wash all areas to be refinished with water and a mild


detergent soap. Rinse thoroughly and let dry.

Clean all areas to be painted with plastic cleaner. R-M 902 Plastic Prep-Cleaner, then
R-M 909 Final Wipe

Sanding Prepare any areas that are to be painted by scuffing with a Scotchbrite #7447
fine scuff pad.

Cleaning Use an air blow gun to remove all traces of dust and dirt R-M 902 Plastic Prep-Cleaner, then
from the cracks and surfaces of the vehicle. R-M 909 Final Wipe

Clean all areas to be painted with plastic cleaner.

Do not allow plastic cleaners to dry on the surface. Apply


wet and then dry with a clean rag.

Pre-prime For bare plastic on flexible plastic parts, apply one coat of R-M 868 1K Plastic Primer
868, 869 or 870. Do not sand. R-M 869 1K Low VOC Adhesion Promoter
R-M 870 High Solids Adhesion Promoter
For bare plastic on semi-rigid or rigid parts, apply one coat for Plastics
of 868, 869 or 870.

Primer Surfacer For flexible parts, apply 2 or 3 coats of primer surfacer 800K 2K Primer Surfacer
mixed with flex additive over any areas that require filling. 846 1K Acrylic Primer
After drying, finish sand with P240 to P320 grit dry, or 892 Flex Agent
P280 to P500 grit wet. See the primer surfacer technical LP20 Epoxy Primer (rigid parts only)
reference sheets for flexed mix ratios.
LP610 Low VOC Primer
For semi-rigid or rigid parts, apply 2 or 3 coats of primer LP620 Low VOC Primer (rigid parts only)
surfacer. After drying, finish sand with P240 to P320 grit 892 Flex Agent
dry, or P280 to P500 grit wet.

Sealer Apply 1 medium wet coat over entire part. Allow to flash 800K 2K Primer Surfacer
for 20 to 30 minutes. See the sealer technical reference LP20 Epoxy Primer (rigid parts only)
sheets for flexed mix ratios. LP610 Low VOC Primer
LP620 Low VOC Primer
LS56 1K Sealer
LS800 2K Sealer
PS21nr 1K Gray Sealer
892 Flex Agent

US. Rev. 11/1/16


A P P L I C A T I O N P R O C E D U R E S

Standard Preparation
for Plastic Parts

Topcoat All Basecoats and 1K Acrylic / Synthetic Enamel colors may All Limco Topcoats
be used on plastic parts without a flex additive. For all 892 Flex Agent
other topcoats see specific technical data sheet for flex
recommendations.

Clearcoat Apply 2 coats of clear over Limco Basecoat colors. Limco 892 LC4000 Clearcoat
Flex Agent must be added to the Limco clearcoats. See the LC4100 High Solids Clearcoat
clearcoat technical reference sheets for flexed mix ratios. LC4200 Low VOC Clearcoat
LC4500 Express Clear
LC4800 Low 2.0 VOC Express Clear
892 Flex Agent

Notes Always check local VOC laws to ensure that the use of these
Limco products is compliant in your area.

Refer to the appropriate Technical Data Sheet(s) for detailed processing information.
Materials described are for application by professional trained personnel only using proper equipment. Products may be hazardous & should be used according to label directions & technical data information. Appropriate respiratory protection should be worn at
all times while products are in use—read product label and Material Safety Data Sheet (MSDS) for specific details. Statements & methods described are based upon the latest standard of technology known to the manufacturer. Application procedures cited are
suggestions only & are not to be interpreted as warranty for events resulting from their use. Dilution ratios are intended to provide maximum performance within the typical Volatile Organic Compound (VOC) restriction for product use. Specific VOC limits need to
be referenced to verify local compliance. Altering the solvent or dilution ratio may impact VOC compliance. User is solely responsible to ensure product use and application is in accordance with all applicable regulatory, legislative, and municipal requirements.
Click on logo to return to Table of Contents

A P P L I C AT I O N P R O C E D U R E S

Standard Preparation for steel,


aluminum, & galvanized metals
General Use this procedure to prepare bare steel, aluminum, zinc coated or galvanized metals.

Cleaning Remove all traces of oil, grease, welding residue or any 203 Wax and Grease Remover, then
other material with wax and grease remover. Remove 139 Final Wash Cleaner
any traces of rust by sanding, wire wheel, brush or
sandblasting. Remove all traces of paint stripper by
following manufacturer’s instructions.

Sanding Steel: dry sand with P80 to P180 grit sandpaper.

Aluminum: dry sand with P120 to P180 grit sandpaper.

Zinc or galvanized metal: use coarse scuff pad. (Do not remove zinc or galvanized coating.)

Cleaning Blow off any dust and reclean metal with 139 Final Wash 139 Final Wash Cleaner
Cleaner.

Do not allow cleaner to dry on the surface. Apply wet and


then dry with a clean rag.

Notes Prime bare metal as soon as possible to prevent further oxidation.

Always check local VOC laws to ensure that the use of these Limco products is compliant in your area.

Refer to the appropriate Technical Data Sheet(s) for detailed processing information.
Materials described are for application by professional trained personnel only using proper equipment. Products may be hazardous & should be used according to label directions & technical data information. Appropriate respiratory protection should be worn at
all times while products are in use—read product label and Material Safety Data Sheet (MSDS) for specific details. Statements & methods described are based upon the latest standard of technology known to the manufacturer. Application procedures cited are
suggestions only & are not to be interpreted as warranty for events resulting from their use. Dilution ratios are intended to provide maximum performance within the typical Volatile Organic Compound (VOC) restriction for product use. Specific VOC limits need to
be referenced to verify local compliance. Altering the solvent or dilution ratio may impact VOC compliance. User is solely responsible to ensure product use and application is in accordance with all applicable regulatory, legislative, and municipal requirements.

US. Rev. 11/1/16


Click on logo to return to Table of Contents

A P P L I C AT I O N P R O C E D U R E S

Standard Preparation for


OEM and cured finishes

General Use this procedure to repair or refinish OEM finishes or fully cured, sound old paint work.

Cleaning Wash all areas to be refinished with water and a mild


detergent soap. Rinse thoroughly and let dry.

Clean all areas to be painted with 203 Wax and Grease 203 Wax and Grease Remover, then
Remover, then do a final wipe with 139 Final Wash 139 Final Wash Cleaner
Cleaner.

Sanding Dry sand all painted areas and any body filler areas that will be primed with P240 grit sandpaper. Be
sure to only prime over sanded areas.

Sand any areas that will be topcoated directly with P400 grit or finer wet or P320 grit or finer dry.

Prepare any areas that are to be blended into by compounding and scuffing with a fine scuff pad.

Cleaning Use an air blow gun to remove all traces of dust and dirt
from the cracks and surfaces of the vehicle.

Clean all areas to be painted with pre-paint cleaner 139 139 Final Wash Cleaner
Final Wash Cleaner making sure to remove all residue. Do
not allow pre-paint cleaners to dry on the surface. Apply
wet and then dry with a clean rag.

Notes Always check local VOC laws to ensure that the use of these Limco products is compliant in your area.

Refer to the appropriate Technical Data Sheet(s) for detailed processing information.
Materials described are for application by professional trained personnel only using proper equipment. Products may be hazardous & should be used according to label directions & technical data information. Appropriate respiratory protection should be worn at
all times while products are in use—read product label and Material Safety Data Sheet (MSDS) for specific details. Statements & methods described are based upon the latest standard of technology known to the manufacturer. Application procedures cited are
suggestions only & are not to be interpreted as warranty for events resulting from their use. Dilution ratios are intended to provide maximum performance within the typical Volatile Organic Compound (VOC) restriction for product use. Specific VOC limits need to
be referenced to verify local compliance. Altering the solvent or dilution ratio may impact VOC compliance. User is solely responsible to ensure product use and application is in accordance with all applicable regulatory, legislative, and municipal requirements.

US. Rev. 11/1/16


Click on logo to return to Table of Contents

A P P L I C AT I O N P R O C E D U R E S

Supreme PLUS Basecoat


Blending Procedure
U.S. National Rule VOC

General Supreme PLUS Basecoat U.S. National Rule VOC is based upon a modified acrylic resin system that can
be blended for the repair of original basecoat/clearcoat finishes.

Preparation Follow the appropriate procedures in the “Standard Preparation” section.

Pre-prime Apply 1 or 2 coats of precoat primer to all bare metal LP20 Epoxy Primer
areas. Allow sufficient flash time between coats. Do not LP100 Etch Primer
sand. Allow to dry for 30 minutes before applying primer
surfacer.

Primer Surfacer Build up any damaged areas with 2 or 3 coats of primer H1000 1K Waterborne Primer *
surfacer. After drying, sand dry with P320 grit sandpaper 800K 2K Primer Surfacer
or sand wet with P400 grit sandpaper. Apply primer 846 1K Acrylic Primer
surfacer per technical reference sheets. LP20 Epoxy Primer
* Dry sand only and can not be used over LP100. LP610 Low VOC Primer
LP620 Low VOC Primer

Sealer A sealer can improve holdout, maximize adhesion and 800K 2K Primer Surfacer
minimize sand scratch swelling. Apply sealer per technical LP20 Epoxy Primer
reference sheets. LP610 Low VOC Primer
LP620 Low VOC Primer
LS56 1K Sealer
LS800 2K Sealer
PS21nr 1K Gray Sealer

US. Rev. 11/1/16


A P P L I C A T I O N P R O C E D U R E S

Supreme PLUS Basecoat


Blending Procedure
U.S. National Rule VOC

Blending Repair area should be sanded with P320-P400 grit sandpaper


Procedure for topcoating with Supreme PLUS Basecoat.
Sand the rest of the panel with P800-P1000 grit sandpaper.
Clean area with pre-paint cleaner. 139 Final Wash Cleaner
Apply 1 coat of LA1202 mixed 1:1 to 1:3 with LR11 over the
area to be blended, let that flash for 10 minutes.
Apply color as needed to achieve proper hiding, make sure to Supreme PLUS Basecoat
stay inside the area with the LA1202 mixture on it.
Blend out color as needed into LA1202 mixture.
Allow 10 minutes flash before applying first coat of clear over LC4000 Clearcoat (High Solids version
entire blend area. only)
LC4100 High Solids Clearcoat
Apply second wet coat of clear over the entire panel.
LC4500 Express Clear

Notes Always check local VOC laws to ensure that the use of these Limco products is compliant in your area.

Refer to the appropriate Technical Data Sheet(s) for detailed processing information.
Materials described are for application by professional trained personnel only using proper equipment. Products may be hazardous & should be used according to label directions & technical data information. Appropriate respiratory protection should be worn at
all times while products are in use—read product label and Material Safety Data Sheet (MSDS) for specific details. Statements & methods described are based upon the latest standard of technology known to the manufacturer. Application procedures cited are
suggestions only & are not to be interpreted as warranty for events resulting from their use. Dilution ratios are intended to provide maximum performance within the typical Volatile Organic Compound (VOC) restriction for product use. Specific VOC limits need to
be referenced to verify local compliance. Altering the solvent or dilution ratio may impact VOC compliance. User is solely responsible to ensure product use and application is in accordance with all applicable regulatory, legislative, and municipal requirements.
Click on logo to return to Table of Contents

A P P L I C AT I O N P R O C E D U R E S

Supreme PLUS Basecoat


Blending Procedure
Low VOC Recommendation

General Supreme PLUS Basecoat Low VOC is based upon a modified acrylic resin system that can be blended for
the repair of original basecoat/clearcoat finishes.

Preparation Follow the appropriate procedures in the “Standard Preparation” section.

Pre-prime Apply 1 or 2 coats of precoat primer to all bare metal LP20 Epoxy Primer
areas. Allow sufficient flash time between coats. Do not LP100 Etch Primer
sand. Allow to dry for 30 minutes before applying primer
surfacer.

Primer Surfacer Build up any damaged areas with 2 or 3 coats of primer H1000 1K Waterborne Primer *
surfacer. After drying, sand dry with P320 grit sandpaper LP20 Epoxy Primer
or sand wet with P400 grit sandpaper. Apply primer LP610 Low VOC Primer
surfacer per technical reference sheets. LP620 Low VOC Primer
* Dry sand only and can not be used over LP100.

Sealer A sealer can improve holdout, maximize adhesion and LP20 Epoxy Primer
minimize sand scratch swelling. Apply sealer per technical LP610 Low VOC Primer
reference sheets. LP620 Low VOC Primer

US. Rev. 11/1/16


A P P L I C A T I O N P R O C E D U R E S

Supreme PLUS Basecoat


Blending Procedure
Low VOC Recommendation

Blending Repair area should be sanded with P320-P400 grit sandpaper


Procedure for topcoating with Supreme PLUS Low VOC Basecoat.
Sand the rest of the panel with P800-P1000 grit sandpaper.
Clean area with pre-paint cleaner. 909 Final Wipe (low VOC mix)
Apply 1 coat of LC4200 or LC4800 mixed 4:1:600-800%
with LR21 over the area to be blended, let that flash for 10 Supreme PLUS Low VOC Basecoat
minutes.
Apply color as needed to achieve proper hiding, make sure to LC4200 Low VOC Clearcoat
stay inside the area with the over reduced clear mixture on it. LC4800 Low 2.0 VOC Express Clear
Blend out color as needed into over reduced clear mixture.
Allow 10 minutes flash before applying first coat of clear over
entire blend area.
Apply second wet coat of clear over the entire panel.

Notes Always check local VOC laws to ensure that the use of these Limco products is compliant in your area.

Refer to the appropriate Technical Data Sheet(s) for detailed processing information.
Materials described are for application by professional trained personnel only using proper equipment. Products may be hazardous & should be used according to label directions & technical data information. Appropriate respiratory protection should be worn at
all times while products are in use—read product label and Material Safety Data Sheet (MSDS) for specific details. Statements & methods described are based upon the latest standard of technology known to the manufacturer. Application procedures cited are
suggestions only & are not to be interpreted as warranty for events resulting from their use. Dilution ratios are intended to provide maximum performance within the typical Volatile Organic Compound (VOC) restriction for product use. Specific VOC limits need to
be referenced to verify local compliance. Altering the solvent or dilution ratio may impact VOC compliance. User is solely responsible to ensure product use and application is in accordance with all applicable regulatory, legislative, and municipal requirements.
Click on logo to return to Table of Contents

U N D E R C O AT S

800K 2K Primer Surfacer


U.S. National Rule Primer Surfacer Application
with LH810, LH820
Description: Limco 800K 2K Primer Surfacer is a very fast curing, easy sanding primer, that provides good sand
scratch filling, no settling in the can, excellent adhesion and topcoat holdout.

Materials: Primer Surfacer: 800K


Hardeners: LH810
LH820
Flex Agent: 892

Substrate/Pretreatment: Cleaning Sanding Second Cleaning


Well cured old paint work 203 Wax and Grease Remover P240 - P400 grit 139 Final Wash Cleaner
O.E.M. primed spare parts 203 Wax and Grease Remover P240 - P400 grit 139 Final Wash Cleaner
Bare steel 203 Wax and Grease Remover P80 - P180 grit 139 Final Wash Cleaner
Galvanized Steel 203 Wax and Grease Remover Coarse scuff pad 139 Final Wash Cleaner
Then, pre-prime with LP20 or LP100
Aluminum 203 Wax and Grease Remover P120 - P180 grit 139 Final Wash Cleaner
Then, pre-prime with LP20 or LP100
Fiberglass plastic parts R-M 902 Plastic Prep-Cleaner P220 grit R-M 902 Plastic Prep-Cleaner
(without gelcoat)

NOTES: On Galvanized Steel and Aluminum, make sure sanding is not so vigorous that it removes the galvanized coating.
With the second cleaning, make sure all residue is removed. Pay special attention when cleaning Galvanized Steel and
Aluminum.

Topcoats: Supreme PLUS Acrylic 1K Single Stage


Supreme PLUS Acrylic 2K Single Stage
Supreme PLUS Urethane Single Stage
Supreme PLUS Basecoat

Remarks: Always check local VOC laws to ensure that the use of these Limco products is compliant in your
area.

US. Rev. 11/1/16


T E C H N I C A L D A T A

800K 2K Primer Surfacer


U.S. National Rule Primer Surfacer Application with LH810, LH820
Flexed
Mixing ratio: 4:1 4:1:1
Primer 4 parts 800K 4 parts 800K
Hardener 1 part LH810 or LH820 1 part LH810 or LH820
Flex Agent — 1 part 892

Potlife at 68°F/20°C 1.5 hours 1.5 hours

Spray viscosity Ford #4


S 18 - 21 seconds 18 - 21 seconds
@ 68°F/20°C

Gravity gun nozzle HVLP 1.5 - 1.7 mm 1.5 - 1.7 mm

Spray pressure HVLP at the cap 8 - 10 psi 8 - 10 psi

Application 2 - 3 medium wet coats 2 - 3 medium wet coats

Flash-off time @ 68°F/20°C 5 minutes between coats 5 minutes between coats

Film build 2.0 - 3.0 mils 2.0 - 3.0 mils

Coverage 567 sq. ft./gal @ 1.0 mils 644 sq. ft./gal @ 1.0 mils

Drying:
68°F/20°C 60 minutes with LH810; 90 minutes with LH810;
1.5 - 2 hours with LH820 2.5 hours with LH820
140°F/60°C 20 minutes 20 minutes
Infra red short wave N/A N/A
Infra red medium wave N/A N/A

Sanding:
Wet by Hand P320 - P400 grit P320 - P400 grit

Dry by Hand P400 grit P400 grit

Dry by Machine P320 - P400 grit P320 - P400 grit

VOC as applied ≤ 580 gms/liter (≤ 4.8 lbs/gal) ≤ 580 gms/liter (≤ 4.8 lbs/gal)

Comments

Materials described are for application by professional trained personnel only using proper equipment. Products may be hazardous & should be used according to label directions & technical data information. Appropriate respiratory protection should be worn at
all times while products are in use—read product label and Material Safety Data Sheet (MSDS) for specific details. Statements & methods described are based upon the latest standard of technology known to the manufacturer. Application procedures cited are
suggestions only & are not to be interpreted as warranty for events resulting from their use. Dilution ratios are intended to provide maximum performance within the typical Volatile Organic Compound (VOC) restriction for product use. Specific VOC limits need to
be referenced to verify local compliance. Altering the solvent or dilution ratio may impact VOC compliance. User is solely responsible to ensure product use and application is in accordance with all applicable regulatory, legislative, and municipal requirements.
Click on logo to return to Table of Contents

U N D E R C O AT S

800K 2K Primer Surfacer


U.S. National Rule Primer Surfacer Application
with LHF, LHM, LHS
Description: Limco 800K 2K Primer Surfacer is a very fast curing, easy sanding primer, that provides good sand
scratch filling, no settling in the can, excellent adhesion and topcoat holdout.

Materials: Primer Surfacer: 800K


Hardeners: LHF
LHM
LHS
Reducers: LR10
LR11
LR12
LR13
LR15
Flex Agent: 892

Substrate/Pretreatment: Cleaning Sanding Second Cleaning


Well cured old paint work 203 Wax and Grease Remover P240 - P400 grit 139 Final Wash Cleaner
O.E.M. primed spare parts 203 Wax and Grease Remover P240 - P400 grit 139 Final Wash Cleaner
Bare steel 203 Wax and Grease Remover P80 - P180 grit 139 Final Wash Cleaner
Galvanized Steel 203 Wax and Grease Remover Coarse scuff pad 139 Final Wash Cleaner
Then, pre-prime with LP20 or LP100
Aluminum 203 Wax and Grease Remover P120 - P180 grit 139 Final Wash Cleaner
Then, pre-prime with LP20 or LP100
Fiberglass plastic parts R-M 902 Plastic Prep-Cleaner P220 grit R-M 902 Plastic Prep-Cleaner
(without gelcoat)

NOTES: On Galvanized Steel and Aluminum, make sure sanding is not so vigorous that it removes the galvanized coating.
With the second cleaning, make sure all residue is removed. Pay special attention when cleaning Galvanized Steel and
Aluminum.

Topcoats: Supreme PLUS Acrylic 1K Single Stage


Supreme PLUS Acrylic 2K Single Stage
Supreme PLUS Urethane Single Stage
Supreme PLUS Basecoat

Remarks: Always check local VOC laws to ensure that the use of these Limco products is compliant in your
area.

US. Rev. 11/1/16


T E C H N I C A L D A T A

800K 2K Primer Surfacer


U.S. National Rule Primer Surfacer Application with LHF, LHM, LHS
Flexed
Mixing ratio: 8:1:1 8:2:1:1
Primer 8 parts 800K 8 parts 800K
Hardener 1 part LHF, LHM or LHS 2 parts LHF, LHM or LHS
Reducer 1 part LR10, LR11, LR12, LR13 or LR15 1 part LR10, LR11, LR12, LR13 or LR15
Flex Agent — 1 part 892

Potlife at 68°F/20°C 30 minutes 30 minutes

Spray viscosity Ford #4


S 18 - 21 seconds 18 - 21 seconds
@ 68°F/20°C

Gravity gun nozzle HVLP 1.5 - 1.7 mm 1.5 - 1.7 mm

Spray pressure HVLP at the cap 8 - 10 psi 8 - 10 psi

Application 2 - 3 medium wet coats 2 - 3 medium wet coats

Flash-off time @ 68°F/20°C 5 minutes between coats 5 minutes between coats

Film build 2.0 - 3.0 mils 2.0 - 3.0 mils

Coverage 573 sq. ft./gal @ 1.0 mils 652 sq. ft./gal @ 1.0 mils

Drying:
68°F/20°C 60 minutes with LHF; 90 minutes with LHF;
1.5 - 2 hours with LHS 2.5 hours with LHS
140°F/60°C 20 minutes 20 minutes
Infra red short wave N/A N/A
Infra red medium wave N/A N/A

Sanding:
Wet by Hand P320 - P400 grit P320 - P400 grit

Dry by Hand P400 grit 400 grit

Dry by Machine P320 - P400 grit P320 - P400 grit

VOC as applied ≤ 580 gms/liter (≤ 4.8 lbs/gal) ≤ 580 gms/liter (≤ 4.8 lbs/gal)

Comments

Materials described are for application by professional trained personnel only using proper equipment. Products may be hazardous & should be used according to label directions & technical data information. Appropriate respiratory protection should be worn at
all times while products are in use—read product label and Material Safety Data Sheet (MSDS) for specific details. Statements & methods described are based upon the latest standard of technology known to the manufacturer. Application procedures cited are
suggestions only & are not to be interpreted as warranty for events resulting from their use. Dilution ratios are intended to provide maximum performance within the typical Volatile Organic Compound (VOC) restriction for product use. Specific VOC limits need to
be referenced to verify local compliance. Altering the solvent or dilution ratio may impact VOC compliance. User is solely responsible to ensure product use and application is in accordance with all applicable regulatory, legislative, and municipal requirements.
Click on logo to return to Table of Contents

U N D E R C O AT S

800K 2K Primer Surfacer


U.S. National Rule Tinted Wet-On-Wet Sealer
Application with LHF, LHM, LHS
Description: Limco 800K 2K as a tinted wet-on-wet sealer is a very fast drying sealer that provides excellent
adhesion with good topcoat color holdout.

Materials: Primer Sealer: 800K


Limco Bases: LA Bases
Hardeners: LHF
LHM
LHS
Reducers: LR21
LR25
Flex Agent: 892

Substrate/Pretreatment: Cleaning Sanding Second Cleaning


Well cured old paint work 203 Wax and Grease Remover P240 - P400 grit 139 Final Wash Cleaner
O.E.M. primed spare parts 203 Wax and Grease Remover P240 - P400 grit 139 Final Wash Cleaner
Bare steel 203 Wax and Grease Remover P80 - P180 grit 139 Final Wash Cleaner
Galvanized Steel 203 Wax and Grease Remover Coarse scuff pad 139 Final Wash Cleaner
Then, pre-prime with LP20 or LP100
Aluminum 203 Wax and Grease Remover P120 - P180 grit 139 Final Wash Cleaner
Then, pre-prime with LP20 or LP100
Fiberglass plastic parts R-M 902 Plastic Prep-Cleaner P220 grit R-M 902 Plastic Prep-Cleaner
(without gelcoat

NOTES: On Galvanized Steel and Aluminum, make sure sanding is not so vigorous that it removes the galvanized coating.
With the second cleaning, make sure all residue is removed. Pay special attention when cleaning Galvanized Steel and
Aluminum.

Topcoats: Supreme PLUS Acrylic 1K Single Stage


Supreme PLUS Acrylic 2K Single Stage
Supreme PLUS Urethane Single Stage
Supreme PLUS Basecoat

Remarks: Always check local VOC laws to ensure that the use of these Limco products is compliant in your
area.

US. Rev. 11/1/16


T E C H N I C A L D A T A

800K 2K Primer Surfacer


U.S. National Rule Tinted Wet-On-Wet Sealer
Application with LHF, LHM, LHS
Flexed
Mixing ratio: Step 1 - 1:1 Step 1 - 1:1
Primer 1 part 800K 1 part 800K
Base 1 part LA Base 1 part LA Base
(without mixing clear) (without mixing clear)
Step 2 - 4:1:1 Step 2 - 4:1:1:1
4 parts 800K / LA Base mixture 4 parts 800K / LA Base mixture
Hardener 1 part LHF, LHM or LHS 1 part LHF, LHM or LHS
Reducer 1 part LR21 or LR25 1 part LR21 or LR25
Flex Agent ­— 1 part 892

Potlife at 68°F/20°C 8 hours 8 hours

Spray viscosity Ford #4


S 13 - 15 seconds 13 - 15 seconds
@ 68°F/20°C

Gravity gun nozzle HVLP 1.3 - 1.5 mm 1.3 - 1.5 mm

Spray pressure HVLP at the cap 8 - 10 psi 8 - 10 psi

Application 1 medium wet coat 1 medium wet coat

Flash-off time @ 68°F/20°C 15 - 30 minutes 15 - 30 minutes

Film build 0.5 - 1.5 mils 0.5 - 1.5 mils

Coverage 585 sq. ft./gal @ 1.0 mils 648 sq. ft./gal @ 1.0 mils

Drying:
68°F/20°C 15 - 30 minutes 15 - 30 minutes
140°F/60°C N/A N/A
Infra red short wave N/A N/A
Infra red medium wave N/A N/A

Sanding:
Wet by Hand N/A N/A

Dry by Hand N/A N/A

Dry by Machine N/A N/A

VOC as applied ≤ 580 gms/liter (≤ 4.8 lbs/gal) ≤ 580 gms/liter (≤ 4.8 lbs/gal)

Comments

Materials described are for application by professional trained personnel only using proper equipment. Products may be hazardous & should be used according to label directions & technical data information. Appropriate respiratory protection should be worn at
all times while products are in use—read product label and Material Safety Data Sheet (MSDS) for specific details. Statements & methods described are based upon the latest standard of technology known to the manufacturer. Application procedures cited are
suggestions only & are not to be interpreted as warranty for events resulting from their use. Dilution ratios are intended to provide maximum performance within the typical Volatile Organic Compound (VOC) restriction for product use. Specific VOC limits need to
be referenced to verify local compliance. Altering the solvent or dilution ratio may impact VOC compliance. User is solely responsible to ensure product use and application is in accordance with all applicable regulatory, legislative, and municipal requirements.
Click on logo to return to Table of Contents

U N D E R C O AT S

800K 2K Primer Surfacer


U.S. National Rule Tinted Wet-On-Wet Sealer
Application with LHF, LHM, LHS
MEXICO ONLY
Description: Limco 800K 2K as a tinted wet-on-wet sealer is a very fast drying sealer that provides excellent
adhesion with good topcoat color holdout.

Materials: Primer Sealer: 800K


Limco Bases: LA Bases
Hardeners: LHF
LHM
LHS
Reducers: LR10
LR11
LR12
LR13
LR15
Flex Agent: 892

Substrate/Pretreatment: Cleaning Sanding Second Cleaning


Well cured old paint work 203 Wax and Grease Remover P240 - P400 grit 139 Final Wash Cleaner
O.E.M. primed spare parts 203 Wax and Grease Remover P240 - P400 grit 139 Final Wash Cleaner
Bare steel 203 Wax and Grease Remover P80 - P180 grit 139 Final Wash Cleaner
Galvanized Steel 203 Wax and Grease Remover Coarse scuff pad 139 Final Wash Cleaner
Then, pre-prime with LP20 or LP100
Aluminum 203 Wax and Grease Remover P120 - P180 grit 139 Final Wash Cleaner
Then, pre-prime with LP20 or LP100
Fiberglass plastic parts R-M 902 Plastic Prep-Cleaner P220 grit R-M 902 Plastic Prep-Cleaner
(without gelcoat

NOTES: On Galvanized Steel and Aluminum, make sure sanding is not so vigorous that it removes the galvanized coating.
With the second cleaning, make sure all residue is removed. Pay special attention when cleaning Galvanized Steel and
Aluminum.

Topcoats: Supreme PLUS Acrylic 1K Single Stage


Supreme PLUS Acrylic 2K Single Stage
Supreme PLUS Urethane Single Stage
Supreme PLUS Basecoat

Remarks: Always check local VOC laws to ensure that the use of these Limco products is compliant in your
area.

US. Rev. 11/1/16


800K 2K Primer Surfacer
U.S. National Rule Tinted Wet-On-Wet Sealer
Application with LHF, LHM, LHS
MEXICO ONLY
Flexed
Mixing ratio: Step 1 - 1:1 Step 1 - 1:1
Primer 1 part 800K 1 part 800K
Base 1 part LA Base 1 part LA Base
(without mixing clear) (without mixing clear)
Step 2 - 4:1:1 Step 2 - 4:1:1:1
4 parts 800K / LA Base mixture 4 parts 800K / LA Base mixture
Hardener 1 part LHF, LHM or LHS 1 part LHF, LHM or LHS
Reducer 1 part LR10, LR11, LR12, LR13 or LR15 1 part LR10, LR11, LR12, LR13 or LR15
Flex Agent ­— 1 part 892

Potlife at 68°F/20°C 8 hours 8 hours

Spray viscosity Ford #4


S 13 - 15 seconds 13 - 15 seconds
@ 68°F/20°C

Gravity gun nozzle HVLP 1.3 - 1.5 mm 1.3 - 1.5 mm

Spray pressure HVLP at the cap 8 - 10 psi 8 - 10 psi

Application 1 medium wet coat 1 medium wet coat

Flash-off time @ 68°F/20°C 15 - 30 minutes 15 - 30 minutes

Film build 0.5 - 1.5 mils 0.5 - 1.5 mils

Coverage 631 sq. ft./gal @ 1.0 mils 689 sq. ft./gal @ 1.0 mils

Drying:
68°F/20°C 15 - 30 minutes 15 - 30 minutes
140°F/60°C N/A N/A
Infra red short wave N/A N/A
Infra red medium wave N/A N/A

Sanding:
Wet by Hand N/A N/A

Dry by Hand N/A N/A

Dry by Machine N/A N/A

Comments
Click on logo to return to Table of Contents

U N D E R C O AT S

846 1K Acrylic Primer


U.S. National Rule Primer Surfacer Application

Description: Limco 846 1K Acrylic Primer is a non-settling, fast drying, easy sanding, flexible primer that meets
the U.S. National Rule and provides excellent adhesion plus good color hold-out.

Materials: Primer: 846


Reducers: LR21
LR25

Substrate/Pretreatment: Cleaning Sanding Second Cleaning


Well cured old paint work 203 Wax and Grease Remover P240 - P400 grit 139 Final Wash Cleaner
O.E.M. primed spare parts 203 Wax and Grease Remover P240 - P400 grit 139 Final Wash Cleaner
Bare steel 203 Wax and Grease Remover P80 - P180 grit 139 Final Wash Cleaner
Galvanized Steel 203 Wax and Grease Remover Coarse scuff pad 139 Final Wash Cleaner
Then, pre-prime with LP20 or LP100
Aluminum 203 Wax and Grease Remover P120 - P180 grit 139 Final Wash Cleaner
Then, pre-prime with LP20 or LP100
Fiberglass plastic parts R-M 902 Plastic Prep-Cleaner P220 grit R-M 902 Plastic Prep-Cleaner
(without gelcoat)

NOTES: On Galvanized Steel and Aluminum, make sure sanding is not so vigorous that it removes the galvanized coating.
With the second cleaning, make sure all residue is removed. Pay special attention when cleaning Galvanized Steel and
Aluminum.

Topcoats: Supreme PLUS Acrylic 1K Single Stage


Supreme PLUS Acrylic 2K Single Stage
Supreme PLUS Urethane Single Stage
Supreme PLUS Basecoat

Remarks: Always check local VOC laws to ensure that the use of these Limco products is compliant in your
area.
846 is a high filling, fast sanding 1K lacquer primer. Best results are obtained when thinner coats,
with 5 - 10 minutes flash between coats, are observed. Excessive film builds of lacquer primer can
lead to soft topcoats or premature film failures.

US. Rev. 11/1/16


T E C H N I C A L D A T A

846 1K Acrylic Primer


U.S. National Rule Primer Surfacer Application
Mixing ratio: 1:1
Primer 1 part 846
Reducer 1 part LR21 or LR25

Potlife at 68°F/20°C N/A

Spray viscosity Ford #4


S 12 - 15 seconds
@ 68°F/20°C

Gravity gun nozzle HVLP 1.5 mm

Spray pressure HVLP at the cap 10 psi

Application 2 - 3 medium wet coats

Flash-off time @ 68°F/20°C 5 - 10 minutes

Film build 2.0 - 3.0 mils

Coverage 548 sq. ft./gal @ 1.0 mils

Drying:
68°F/20°C 20 minutes
140°F/60°C N/A
Infra red short wave N/A
Infra red medium wave N/A

Sanding:
Wet by Hand N/A

Dry by Hand P320 grit

Dry by Machine P280 grit

VOC as applied ≤ 580 gms/liter (≤ 4.8 lbs/gal)

Comments

Materials described are for application by professional trained personnel only using proper equipment. Products may be hazardous & should be used according to label directions & technical data information. Appropriate respiratory protection should be worn at
all times while products are in use—read product label and Material Safety Data Sheet (MSDS) for specific details. Statements & methods described are based upon the latest standard of technology known to the manufacturer. Application procedures cited are
suggestions only & are not to be interpreted as warranty for events resulting from their use. Dilution ratios are intended to provide maximum performance within the typical Volatile Organic Compound (VOC) restriction for product use. Specific VOC limits need to
be referenced to verify local compliance. Altering the solvent or dilution ratio may impact VOC compliance. User is solely responsible to ensure product use and application is in accordance with all applicable regulatory, legislative, and municipal requirements.
Click on logo to return to Table of Contents

U N D E R C O AT S

H1000 1K Waterborne Primer


Low VOC Primer Surfacer Application

Description: Limco H1000 1K Waterborne Primer is a grey, 1K Low VOC Waterborne System that is fast drying,
easy sanding and provides excellent adhesion with good color holdout.

Materials: Primer Surfacer: H1000

Substrate/Pretreatment: Cleaning Sanding Second Cleaning


Well cured old paint work R-M 909 Final Wipe P240 - P400 grit R-M 909 Final Wipe
O.E.M. primed spare parts R-M 909 Final Wipe P240 - P400 grit R-M 909 Final Wipe
Bare steel R-M 909 Final Wipe P80 - P180 grit R-M 909 Final Wipe
Galvanized Steel R-M 909 Final Wipe Coarse scuff pad R-M 909 Final Wipe
Then, pre-prime with LP20
Aluminum R-M 909 Final Wipe P120 - P180 grit R-M 909 Final Wipe
Then, pre-prime with LP20
Fiberglass plastic parts R-M 909 Final Wipe P220 grit R-M 909 Final Wipe
(without gelcoat)

NOTES: On Galvanized Steel and Aluminum, make sure sanding is not so vigorous that it removes the galvanized coating.
With the second cleaning, make sure all residue is removed. Pay special attention when cleaning Galvanized Steel and
Aluminum.

Topcoats: Supreme PLUS Acrylic 1K Single Stage (U.S. National Rule and Low VOC)
Supreme PLUS Acrylic 2K Single Stage (U.S. National Rule and Low VOC)
Supreme PLUS Urethane Single Stage (U.S. National Rule and Low VOC)
Supreme PLUS Basecoat (U.S. National Rule and Low VOC)

Remarks: Always check local VOC laws to ensure that the use of these Limco products is compliant in your
area.
Shelf Life - 12 months
Keep from freezing.
Store at temperatures 40°F - 105°F / 5°C - 40°C.
Dry sand only. DO NOT wet sand H1000 1K Waterborne Primer.

US. Rev. 11/1/16


T E C H N I C A L D A T A

H1000 1K Waterborne Primer


Low VOC Primer Surfacer Application
Mixing ratio: Ready for use
Primer H1000

Potlife at 68°F/20°C N/A

Spray viscosity Ford #4


S 14 - 16 seconds
@ 68°F/20°C

Gravity gun nozzle HVLP 1.5 mm

Spray pressure HVLP at the cap 10 psi

Application 2 - 3 coats

Flash-off time @ 68°F/20°C 5 - 10 minutes between coats

Film build 2.0 - 3.0 mils

Coverage 655 sq. ft./gal @ 1.0 mils

Drying:
68°F/20°C 30 minutes
140°F/60°C N/A
Infra red short wave N/A
Infra red medium wave N/A

Sanding:
Wet by Hand N/A

Dry by Hand P320 grit

Dry by Machine P280 grit

VOC as applied ≤ 250 gms/liter (≤ 2.1 lbs/gal)

Comments

Materials described are for application by professional trained personnel only using proper equipment. Products may be hazardous & should be used according to label directions & technical data information. Appropriate respiratory protection should be worn at
all times while products are in use—read product label and Material Safety Data Sheet (MSDS) for specific details. Statements & methods described are based upon the latest standard of technology known to the manufacturer. Application procedures cited are
suggestions only & are not to be interpreted as warranty for events resulting from their use. Dilution ratios are intended to provide maximum performance within the typical Volatile Organic Compound (VOC) restriction for product use. Specific VOC limits need to
be referenced to verify local compliance. Altering the solvent or dilution ratio may impact VOC compliance. User is solely responsible to ensure product use and application is in accordance with all applicable regulatory, legislative, and municipal requirements.
Click on logo to return to Table of Contents

U N D E R C O AT S

LP20 Epoxy Primer


U.S. National Rule Primer Application

Description: Limco LP20 Epoxy Primer is a two part epoxy primer for use as a primer under 800K, 846, PS21nr,
LS800 or LS56. LP20 offers excellent adhesion and corrosion protection when used over steel,
aluminum, zinc coated or galvanized metals. LP20 can be applied over cured, cleaned and sanded
paint finishes (except acrylic lacquers).

Materials: Primer: LP20


Activator: LA20
Reducer: LR21

Substrate/Pretreatment: Cleaning Sanding Second Cleaning


Well cured old paint work 203 Wax and Grease Remover P240 - P400 grit 139 Final Wash Cleaner
O.E.M. primed spare parts 203 Wax and Grease Remover P240 - P400 grit 139 Final Wash Cleaner
Bare steel 203 Wax and Grease Remover P80 - P180 grit 139 Final Wash Cleaner
Galvanized Steel 203 Wax and Grease Remover Coarse scuff pad 139 Final Wash Cleaner
Aluminum 203 Wax and Grease Remover P120 - P180 grit 139 Final Wash Cleaner
Fiberglass plastic parts LP20 is not recommended over this substrate
(without gelcoat)

NOTES: On Galvanized Steel and Aluminum, make sure sanding is not so vigorous that it removes the galvanized coating.
With the second cleaning, make sure all residue is removed. Pay special attention when cleaning Galvanized Steel and
Aluminum.

Topcoats: Supreme PLUS Acrylic 1K Single Stage


Supreme PLUS Acrylic 2K Single Stage
Supreme PLUS Urethane Single Stage
Supreme PLUS Basecoat

Remarks: Always check local VOC laws to ensure that the use of these Limco products is compliant in your
area.

US. Rev. 11/1/16


T E C H N I C A L D A T A

LP20 Epoxy Primer


U.S. National Rule Primer Application
Mixing ratio: 3:1:1
Primer 3 parts LP20
Activator 1 part LA20
Reducer 1 part LR21

Potlife at 68°F/20°C 8 hours

Spray viscosity Ford #4


S 12 seconds
@ 68°F/20°C

Gravity gun nozzle HVLP 1.3 - 1.5 mm

Spray pressure HVLP at the cap 6 - 10 psi

Application 1 - 2 light coats

Flash-off time @ 68°F/20°C 5 - 10 minutes between coats

Film build 0.5 - 0.75 mils

Coverage 697 sq. ft./gal @ 1.0 mils

Drying:
68°F/20°C 15 - 30 minutes
140°F/60°C N/A
Infra red short wave N/A
Infra red medium wave N/A

Sanding:
Wet by Hand N/A

Dry by Hand N/A

Dry by Machine N/A

VOC as applied ≤ 580 gms/liter (≤ 4.8 lbs/gal)

Comments Do not use over flexible parts.

Materials described are for application by professional trained personnel only using proper equipment. Products may be hazardous & should be used according to label directions & technical data information. Appropriate respiratory protection should be worn at
all times while products are in use—read product label and Material Safety Data Sheet (MSDS) for specific details. Statements & methods described are based upon the latest standard of technology known to the manufacturer. Application procedures cited are
suggestions only & are not to be interpreted as warranty for events resulting from their use. Dilution ratios are intended to provide maximum performance within the typical Volatile Organic Compound (VOC) restriction for product use. Specific VOC limits need to
be referenced to verify local compliance. Altering the solvent or dilution ratio may impact VOC compliance. User is solely responsible to ensure product use and application is in accordance with all applicable regulatory, legislative, and municipal requirements.
Click on logo to return to Table of Contents

U N D E R C O AT S

LP20 Epoxy Primer


Low VOC Primer Application

Description: LP20 Epoxy Primer is a two part epoxy primer for use as a primer under H1000, LP610 or LP620.
LP20 offers excellent adhesion and corrosion protection when used over steel, aluminum, zinc
coated or galvanized metals. LP20 can be applied over cured, cleaned and sanded paint finishes
(except acrylic lacquers).

Materials: Primer: LP20


Activator: LA25
Reducer: LR21

Substrate/Pretreatment: Cleaning Sanding Second Cleaning


Well cured old paint work R-M 909 Final Wipe P240 - P400 grit R-M 909 Final Wipe
O.E.M. primed spare parts R-M 909 Final Wipe P240 - P400 grit R-M 909 Final Wipe
Bare steel R-M 909 Final Wipe P80 - P180 grit R-M 909 Final Wipe
Galvanized Steel R-M 909 Final Wipe Coarse scuff pad R-M 909 Final Wipe
Aluminum R-M 909 Final Wipe P120 - P180 grit R-M 909 Final Wipe
Fiberglass plastic parts LP20 is not recommended over this substrate
(without gelcoat)

NOTES: On Galvanized Steel and Aluminum, make sure sanding is not so vigorous that it removes the galvanized coating.
With the second cleaning, make sure all residue is removed. Pay special attention when cleaning Galvanized Steel and
Aluminum.

Topcoats: Supreme PLUS Low VOC Acrylic 1K Single Stage 340 gms/liter (2.8 lbs/gal) VOC
Supreme PLUS Low VOC Acrylic 1K Single Stage 420 gms/liter (3.5 lbs/gal) VOC
Supreme PLUS Low VOC Acrylic 2K Single Stage 340 gms/liter (2.8 lbs/gal) VOC
Supreme PLUS Low VOC Acrylic 2K Single Stage 420 gms/liter (3.5 lbs/gal) VOC
Supreme PLUS Low VOC Urethane Single Stage 340 gms/liter (2.8 lbs/gal) VOC
Supreme PLUS Low VOC Urethane Single Stage 420 gms/liter (3.5 lbs/gal) VOC
Supreme PLUS Low VOC Basecoat 420 gms/liter (3.5 lbs/gal) VOC

Remarks: Always check local VOC laws to ensure that the use of these Limco products is compliant in your
area.

US. Rev. 11/1/16


T E C H N I C A L D A T A

LP20 Epoxy Primer


Low VOC Primer Application
Mixing ratio: 4:1:1
Primer 4 parts LP20
Activator 1 part LA25
Reducer 1 part LR21

Potlife at 68°F/20°C 8 hours

Spray viscosity Ford #4


S 12 seconds
@ 68°F/20°C

Gravity gun nozzle HVLP 1.3 - 1.5 mm

Spray pressure HVLP at the cap 6 - 10 psi

Application 1 - 2 light coats

Flash-off time @ 68°F/20°C 5 - 10 minutes between coats

Film build 0.5 - 0.75 mils

Coverage 762 sq. ft./gal @ 1.0 mils

Drying:
68°F/20°C 15 - 30 minutes
140°F/60°C N/A
Infra red short wave N/A
Infra red medium wave N/A

Sanding:
Wet by Hand N/A

Dry by Hand N/A

Dry by Machine N/A

VOC as applied ≤ 250 gms/liter (≤ 2.1 lbs/gal)

Comments Do not use over flexible parts.

Materials described are for application by professional trained personnel only using proper equipment. Products may be hazardous & should be used according to label directions & technical data information. Appropriate respiratory protection should be worn at
all times while products are in use—read product label and Material Safety Data Sheet (MSDS) for specific details. Statements & methods described are based upon the latest standard of technology known to the manufacturer. Application procedures cited are
suggestions only & are not to be interpreted as warranty for events resulting from their use. Dilution ratios are intended to provide maximum performance within the typical Volatile Organic Compound (VOC) restriction for product use. Specific VOC limits need to
be referenced to verify local compliance. Altering the solvent or dilution ratio may impact VOC compliance. User is solely responsible to ensure product use and application is in accordance with all applicable regulatory, legislative, and municipal requirements.
Click on logo to return to Table of Contents

U N D E R C O AT S

LP20 Epoxy Primer


U.S. National Rule Primer Surfacer Application

Description: Limco LP20 Epoxy Primer is a two part epoxy primer for use as a Primer Surfacer. LP20 offers excellent
adhesion and corrosion protection when used over steel, aluminum, zinc coated or galvanized
metals. LP20 can be applied over cured, cleaned and sanded paint finishes (except acrylic lacquers).

Materials: Primer Surfacer: LP20


Activator: LA20
Reducer: LR21

Substrate/Pretreatment: Cleaning Sanding Second Cleaning


Well cured old paint work 203 Wax and Grease Remover P240 - P400 grit 139 Final Wash Cleaner
O.E.M. primed spare parts 203 Wax and Grease Remover P240 - P400 grit 139 Final Wash Cleaner
Bare steel 203 Wax and Grease Remover P80 - P180 grit 139 Final Wash Cleaner
Galvanized Steel 203 Wax and Grease Remover Coarse scuff pad 139 Final Wash Cleaner
Aluminum 203 Wax and Grease Remover P120 - P180 grit 139 Final Wash Cleaner
Fiberglass plastic parts LP20 is not recommended over this substrate
(without gelcoat)

NOTES: On Galvanized Steel and Aluminum, make sure sanding is not so vigorous that it removes the galvanized coating.
With the second cleaning, make sure all residue is removed. Pay special attention when cleaning Galvanized Steel and
Aluminum.

Topcoats: Supreme PLUS Acrylic 1K Single Stage


Supreme PLUS Acrylic 2K Single Stage
Supreme PLUS Urethane Single Stage
Supreme PLUS Basecoat

Remarks: Always check local VOC laws to ensure that the use of these Limco products is compliant in your
area.

US. Rev. 11/1/16


T E C H N I C A L D A T A

LP20 Epoxy Primer


U.S. National Rule Primer Surfacer Application
Mixing ratio: 3:1:1
Primer 3 parts LP20
Activator 1 part LA20
Reducer 1 part LR21

Potlife at 68°F/20°C 8 hours

Spray viscosity Ford #4


S 12 seconds
@ 68°F/20°C

Gravity gun nozzle HVLP 1.5 - 1.8 mm

Spray pressure HVLP at the cap 6 - 10 psi

Application 2 - 3 medium coats

Flash-off time @ 68°F/20°C 5 - 10 minutes between coats

Film build 2.0 - 2.5 mils

Coverage 697 sq. ft./gal @ 1.0 mils

Drying:
68°F/20°C 3 hours
140°F/60°C 30 - 35 minutes
Infra red short wave N/A
Infra red medium wave N/A

Sanding:
Wet by Hand P400 - P600 grit

Dry by Hand P320 - P400 grit

Dry by Machine P320 - P400 grit

VOC as applied ≤ 580 gms/liter (≤ 4.8 lbs/gal)

Comments Do not use over flexible parts.

Materials described are for application by professional trained personnel only using proper equipment. Products may be hazardous & should be used according to label directions & technical data information. Appropriate respiratory protection should be worn at
all times while products are in use—read product label and Material Safety Data Sheet (MSDS) for specific details. Statements & methods described are based upon the latest standard of technology known to the manufacturer. Application procedures cited are
suggestions only & are not to be interpreted as warranty for events resulting from their use. Dilution ratios are intended to provide maximum performance within the typical Volatile Organic Compound (VOC) restriction for product use. Specific VOC limits need to
be referenced to verify local compliance. Altering the solvent or dilution ratio may impact VOC compliance. User is solely responsible to ensure product use and application is in accordance with all applicable regulatory, legislative, and municipal requirements.
Click on logo to return to Table of Contents

U N D E R C O AT S

LP20 Epoxy Primer


Low VOC Primer Surfacer Application

Description: Limco LP20 Epoxy Primer is a two part epoxy primer for use as a Primer Surfacer. LP20 offers excellent
adhesion and corrosion protection when used over steel, aluminum, zinc coated or galvanized
metals. LP20 can be applied over cured, cleaned and sanded paint finishes (except acrylic lacquers).

Materials: Primer Surfacer: LP20


Activator: LA25
Reducer: LR21

Substrate/Pretreatment: Cleaning Sanding Second Cleaning


Well cured old paint work R-M 909 Final Wipe P240 - P400 grit R-M 909 Final Wipe
O.E.M. primed spare parts R-M 909 Final Wipe P240 - P400 grit R-M 909 Final Wipe
Bare steel R-M 909 Final Wipe P80 - P180 grit R-M 909 Final Wipe
Galvanized Steel R-M 909 Final Wipe Coarse scuff pad R-M 909 Final Wipe
Aluminum R-M 909 Final Wipe P120 - P180 grit R-M 909 Final Wipe
Fiberglass plastic parts LP20 is not recommended over this substrate
(without gelcoat)

NOTES: On Galvanized Steel and Aluminum, make sure sanding is not so vigorous that it removes the galvanized coating.
With the second cleaning, make sure all residue is removed. Pay special attention when cleaning Galvanized Steel and
Aluminum.

Topcoats: Supreme PLUS Low VOC Acrylic 1K Single Stage 340 gms/liter (2.8 lbs/gal) VOC
Supreme PLUS Low VOC Acrylic 1K Single Stage 420 gms/liter (3.5 lbs/gal) VOC
Supreme PLUS Low VOC Acrylic 2K Single Stage 340 gms/liter (2.8 lbs/gal) VOC
Supreme PLUS Low VOC Acrylic 2K Single Stage 420 gms/liter (3.5 lbs/gal) VOC
Supreme PLUS Low VOC Urethane Single Stage 340 gms/liter (2.8 lbs/gal) VOC
Supreme PLUS Low VOC Urethane Single Stage 420 gms/liter (3.5 lbs/gal) VOC
Supreme PLUS Low VOC Basecoat 420 gms/liter (3.5 lbs/gal) VOC

Remarks: Always check local VOC laws to ensure that the use of these Limco products is compliant in your
area.

US. Rev. 11/1/16


T E C H N I C A L D A T A

LP20 Epoxy Primer


Low VOC Primer Surfacer Application
Mixing ratio: 4:1:1
Primer 4 parts LP20
Activator 1 part LA25
Reducer 1 part LR21

Potlife at 68°F/20°C 8 hours

Spray viscosity Ford #4


S 20 seconds
@ 68°F/20°C

Gravity gun nozzle HVLP 1.5 - 1.8 mm

Spray pressure HVLP at the cap 6 - 10 psi

Application 2 - 3 medium coats

Flash-off time @ 68°F/20°C 5 - 10 minutes between coats

Film build 2.0 - 2.5 mils

Coverage 762 sq. ft./gal @ 1.0 mils

Drying:
68°F/20°C 6 hours
140°F/60°C 30 - 35 minutes
Infra red short wave N/A
Infra red medium wave N/A

Sanding:
Wet by Hand P400 - P600 grit

Dry by Hand P320 - P400 grit

Dry by Machine P320 - P400 grit

VOC as applied ≤ 250 gms/liter (≤ 2.1 lbs/gal)

Comments Do not use over flexible parts.

Materials described are for application by professional trained personnel only using proper equipment. Products may be hazardous & should be used according to label directions & technical data information. Appropriate respiratory protection should be worn at
all times while products are in use—read product label and Material Safety Data Sheet (MSDS) for specific details. Statements & methods described are based upon the latest standard of technology known to the manufacturer. Application procedures cited are
suggestions only & are not to be interpreted as warranty for events resulting from their use. Dilution ratios are intended to provide maximum performance within the typical Volatile Organic Compound (VOC) restriction for product use. Specific VOC limits need to
be referenced to verify local compliance. Altering the solvent or dilution ratio may impact VOC compliance. User is solely responsible to ensure product use and application is in accordance with all applicable regulatory, legislative, and municipal requirements.
Click on logo to return to Table of Contents

U N D E R C O AT S

LP20 Epoxy Primer


Wet-On-Wet Sealer Application

Description: Limco LP20 Epoxy Primer is a two part epoxy primer for use as a wet-on-wet sealer under Limco
Supreme PLUS topcoats. LP20 can be applied over cured, cleaned and sanded paint finishes (except
acrylic lacquers).

Materials: Sealer: LP20


Activator: LA20
Reducer: LR21

Substrate/Pretreatment: Cleaning Sanding Second Cleaning


Well cured old paint work 203 Wax and Grease Remover P240 - P400 grit 139 Final Wash Cleaner
O.E.M. primed spare parts 203 Wax and Grease Remover P240 - P400 grit 139 Final Wash Cleaner
Bare steel 203 Wax and Grease Remover P80 - P180 grit 139 Final Wash Cleaner
Galvanized Steel 203 Wax and Grease Remover Coarse scuff pad 139 Final Wash Cleaner
Aluminum 203 Wax and Grease Remover P120 - P180 grit 139 Final Wash Cleaner
Fiberglass plastic parts LP20 is not recommended over this substrate
(without gelcoat)

NOTES: On Galvanized Steel and Aluminum, make sure sanding is not so vigorous that it removes the galvanized coating.
With the second cleaning, make sure all residue is removed. Pay special attention when cleaning Galvanized Steel and
Aluminum.

Topcoats: Supreme PLUS Acrylic 1K Single Stage


Supreme PLUS Acrylic 2K Single Stage
Supreme PLUS Urethane Single Stage
Supreme PLUS Basecoat

Remarks: Always check local VOC laws to ensure that the use of these Limco products is compliant in your
area.

US. Rev. 11/1/16


T E C H N I C A L D A T A

LP20 Epoxy Primer


Wet-On-Wet Sealer Application
Tinted with
Untinted
LA Bases
Mixing ratio: 3:1:1 3:1:1:1
Primer 3 parts LP20 3 parts LP20
Base – 1 part LA Base
Activator 1 part LA20 1 part LA20
Reducer 1 part LR21 1 part LR21

Potlife at 68°F/20°C 8 hours 8 hours

Spray viscosity Ford #4


S 12 seconds 12 seconds
@ 68°F/20°C

Gravity gun nozzle HVLP 1.5 - 1.8 mm 1.5 - 1.8 mm

Spray pressure HVLP at the cap 6 - 10 psi 6 - 10 psi

1 medium wet coat 1 medium wet coat


Application
or 2 light coats or 2 light coats

5 - 10 minutes 5 - 10 minutes
Flash-off time @ 68°F/20°C
between coats between coats

Film build 0.75 - 1.3 mils 0.75 - 1.3 mils

Coverage 697 sq. ft./gal @ 1.0 mils 688 sq. ft./gal @ 1.0 mils

Drying:
68°F/20°C 45 minutes before topcoating 45 minutes before topcoating
with Limco with Limco
140°F/60°C N/A N/A
Infra red short wave N/A N/A
Infra red medium wave N/A N/A

Sanding:
Wet by Hand N/A N/A

Dry by Hand N/A N/A

Dry by Machine N/A N/A

VOC as applied ≤ 550 gms/liter (≤ 4.6 lbs/gal) ≤ 550 gms/liter (≤ 4.6 lbs/gal)

Comments Do not use over flexible parts.

Materials described are for application by professional trained personnel only using proper equipment. Products may be hazardous & should be used according to label directions & technical data information. Appropriate respiratory protection should be worn at
all times while products are in use—read product label and Material Safety Data Sheet (MSDS) for specific details. Statements & methods described are based upon the latest standard of technology known to the manufacturer. Application procedures cited are
suggestions only & are not to be interpreted as warranty for events resulting from their use. Dilution ratios are intended to provide maximum performance within the typical Volatile Organic Compound (VOC) restriction for product use. Specific VOC limits need to
be referenced to verify local compliance. Altering the solvent or dilution ratio may impact VOC compliance. User is solely responsible to ensure product use and application is in accordance with all applicable regulatory, legislative, and municipal requirements.
Click on logo to return to Table of Contents

U N D E R C O AT S

LP20 Epoxy Primer


Low VOC Wet-On-Wet Sealer Application

Description: Limco LP20 Epoxy Primer is a two part epoxy primer for use as a wet-on-wet sealer under Limco
Supreme PLUS topcoats. LP20 can be applied over cured, cleaned and sanded paint finishes (except
acrylic lacquers).

Materials: Sealer: LP20


Activator: LA25
Reducer: LR21

Substrate/Pretreatment: Cleaning Sanding Second Cleaning


Well cured old paint work R-M 909 Final Wipe P240 - P400 grit R-M 909 Final Wipe
O.E.M. primed spare parts R-M 909 Final Wipe P240 - P400 grit R-M 909 Final Wipe
Bare steel R-M 909 Final Wipe P80 - P180 grit R-M 909 Final Wipe
Galvanized Steel R-M 909 Final Wipe Coarse scuff pad R-M 909 Final Wipe
Aluminum R-M 909 Final Wipe P120 - P180 grit R-M 909 Final Wipe
Fiberglass plastic parts LP20 is not recommended over this substrate
(without gelcoat)

NOTES: On Galvanized Steel and Aluminum, make sure sanding is not so vigorous that it removes the galvanized coating.
With the second cleaning, make sure all residue is removed. Pay special attention when cleaning Galvanized Steel and
Aluminum.

Topcoats: Supreme PLUS Low VOC Acrylic 1K Single Stage 340 gms/liter (2.8 lbs/gal) VOC
Supreme PLUS Low VOC Acrylic 1K Single Stage 420 gms/liter (3.5 lbs/gal) VOC
Supreme PLUS Low VOC Acrylic 2K Single Stage 340 gms/liter (2.8 lbs/gal) VOC
Supreme PLUS Low VOC Acrylic 2K Single Stage 420 gms/liter (3.5 lbs/gal) VOC
Supreme PLUS Low VOC Urethane Single Stage 340 gms/liter (2.8 lbs/gal) VOC
Supreme PLUS Low VOC Urethane Single Stage 420 gms/liter (3.5 lbs/gal) VOC
Supreme PLUS Low VOC Basecoat 420 gms/liter (3.5 lbs/gal) VOC

Remarks: Always check local VOC laws to ensure that the use of these Limco products is compliant in your
area.

US. Rev. 11/1/16


T E C H N I C A L D A T A

LP20 Epoxy Primer


Low VOC Wet-On-Wet Sealer Application
Mixing ratio: 4:1:1
Primer 4 parts LP20
Base –
Activator 1 part LA25
Reducer 1 part LR21

Potlife at 68°F/20°C 8 hours

Spray viscosity Ford #4


S 12 seconds
@ 68°F/20°C

Gravity gun nozzle HVLP 1.5 - 1.8 mm

Spray pressure HVLP at the cap 6 - 10 psi

Application 1 medium wet coat or 2 light coats

Flash-off time @ 68°F/20°C 5 - 10 minutes between coats

Film build 0.75 - 1.3 mils

Coverage 762 sq. ft./gal @ 1.0 mils

Drying:
68°F/20°C 45 minutes before topcoating with Limco
140°F/60°C N/A
Infra red short wave N/A
Infra red medium wave N/A

Sanding:
Wet by Hand N/A

Dry by Hand N/A

Dry by Machine N/A

VOC as applied ≤ 250 gms/liter (≤ 2.1 lbs/gal)

Comments Do not use over flexible parts.

Materials described are for application by professional trained personnel only using proper equipment. Products may be hazardous & should be used according to label directions & technical data information. Appropriate respiratory protection should be worn at
all times while products are in use—read product label and Material Safety Data Sheet (MSDS) for specific details. Statements & methods described are based upon the latest standard of technology known to the manufacturer. Application procedures cited are
suggestions only & are not to be interpreted as warranty for events resulting from their use. Dilution ratios are intended to provide maximum performance within the typical Volatile Organic Compound (VOC) restriction for product use. Specific VOC limits need to
be referenced to verify local compliance. Altering the solvent or dilution ratio may impact VOC compliance. User is solely responsible to ensure product use and application is in accordance with all applicable regulatory, legislative, and municipal requirements.
Click on logo to return to Table of Contents

U N D E R C O AT S

LP100 Etch Primer


U.S. National Rule Primer Application

Description: Limco LP100 Etch Primer is chromate free and has excellent adhesion properties that work equally
well on steel, aluminum and galvanized steel. When applied over bare steel, LP100 is an effective
rust inhibitor. Limco LP100 can be primed over with any approved Limco undercoat except H1000.
Limco LP100 should also not be used under waterborne primers or peroxide-cured body fillers.

Materials: Primer: LP100


Activator: LPA100
Reducers: LR10
LR11
LR12
LR13
LR15

Substrate/Pretreatment: Cleaning Sanding Second Cleaning


Well cured old paint work LP100 is not recommended over this substrate
O.E.M. primed spare parts LP100 is not recommended over this substrate
Bare steel 203 Wax and Grease Remover P80 - P180 grit 139 Final Wash Cleaner
Galvanized steel 203 Wax and Grease Remover Coarse scuff pad 139 Final Wash Cleaner
Aluminum 203 Wax and Grease Remover P120 - P180 grit 139 Final Wash Cleaner
Fiberglass plastic parts LP100 is not recommended over this substrate
(without gelcoat)

NOTES: On Galvanized Steel and Aluminum, make sure sanding is not so vigorous that it removes the galvanized coating.
With the second cleaning, make sure all residue is removed. Pay special attention when cleaning Galvanized Steel and
Aluminum.

Topcoats: A topcoat can not be applied directly over LP100.

Remarks: Always check local VOC laws to ensure that the use of these Limco products is compliant in your
area.

US. Rev. 11/1/16


T E C H N I C A L D A T A

LP100 Etch Primer


U.S. National Rule Primer Application
Mixing ratio: 1:1:50%
Primer 1 part LP100
Activator 1 part LPA100
Reducer 50% LR10, LR11, LR12, LR13 or LR15

Potlife at 68°F/20°C N/A

Spray viscosity Ford #4


S 12 - 13 seconds
@ 68°F/20°C

Gravity gun nozzle HVLP 1.5 mm

Spray pressure HVLP at the cap 8 - 10 psi

Application 1 medium wet coat or 2 light coats

Flash-off time @ 68°F/20°C 5 - 10 minutes

Film build 0.5 - 1.5 mils

Coverage 171 sq. ft./gal @ 1.0 mils

Drying:
68°F/20°C 15 minutes
140°F/60°C N/A
Infra red short wave N/A
Infra red medium wave N/A

Sanding:
Wet by Hand N/A

Dry by Hand N/A

Dry by Machine N/A

VOC as applied ≤ 780 gms/liter (≤ 6.5 lbs/gal)

Comments Appropriate undercoat must be applied on top of LP100 within 4 hours of application.

Materials described are for application by professional trained personnel only using proper equipment. Products may be hazardous & should be used according to label directions & technical data information. Appropriate respiratory protection should be worn at
all times while products are in use—read product label and Material Safety Data Sheet (MSDS) for specific details. Statements & methods described are based upon the latest standard of technology known to the manufacturer. Application procedures cited are
suggestions only & are not to be interpreted as warranty for events resulting from their use. Dilution ratios are intended to provide maximum performance within the typical Volatile Organic Compound (VOC) restriction for product use. Specific VOC limits need to
be referenced to verify local compliance. Altering the solvent or dilution ratio may impact VOC compliance. User is solely responsible to ensure product use and application is in accordance with all applicable regulatory, legislative, and municipal requirements.
Click on logo to return to Table of Contents

U N D E R C O AT S

LP100 Etch Primer


Low VOC Primer Application

Description: Limco LP100 Etch Primer is chromate free and has excellent adhesion properties that work equally
well on steel, aluminum and galvanized steel. When applied over bare steel, LP100 is an effective
rust inhibitor. Limco LP100 can be primed over with any approved Limco undercoat except H1000.
Limco LP100 should also not be used under waterborne primers or peroxide-cured body fillers.

Materials: Primer: LP100


Activator: LPA100
Reducers: LR21
LR25

Substrate/Pretreatment: Cleaning Sanding Second Cleaning


Well cured old paint work LP100 is not recommended over this substrate
O.E.M. primed spare parts LP100 is not recommended over this substrate
Bare steel R-M 909 Final Wipe P80 - P180 grit R-M 909 Final Wipe
Galvanized steel R-M 909 Final Wipe Coarse scuff pad R-M 909 Final Wipe
Aluminum R-M 909 Final Wipe P120 - P180 grit R-M 909 Final Wipe
Fiberglass plastic parts LP100 is not recommended over this substrate
(without gelcoat)

NOTES: On Galvanized Steel and Aluminum, make sure sanding is not so vigorous that it removes the galvanized coating.
With the second cleaning, make sure all residue is removed. Pay special attention when cleaning Galvanized Steel and
Aluminum.

Topcoats: A topcoat can not be applied directly over LP100.

Remarks: Always check local VOC laws to ensure that the use of these Limco products is compliant in your
area.

US. Rev. 11/1/16


T E C H N I C A L D A T A

LP100 Etch Primer


Low VOC Primer Application
Mixing ratio: 1:1:150%
Primer 1 part LP100
Activator 1 part LPA100
Reducer 150% LR21 or LR25

Potlife at 68°F/20°C N/A

Spray viscosity Ford #4


S 10 - 11 seconds
@ 68°F/20°C

Gravity gun nozzle HVLP 1.5 mm

Spray pressure HVLP at the cap 8 - 10 psi

Application 1 medium wet coat or 2 light coats

Flash-off time @ 68°F/20°C 5 - 10 minutes

Film build 0.5 - 1.5 milS

Coverage 122 sq. ft./gal @ 1.0 milS

Drying:
68°F/20°C 15 minutes
140°F/60°C N/A
Infra red short wave N/A
Infra red medium wave N/A

Sanding:
Wet by Hand N/A

Dry by Hand N/A

Dry by Machine N/A

VOC as applied ≤ 660 gms/liter (≤ 5.5 lbs/gal)

Comments Appropriate undercoat must be applied on top of LP100 within 4 hours of application.

Materials described are for application by professional trained personnel only using proper equipment. Products may be hazardous & should be used according to label directions & technical data information. Appropriate respiratory protection should be worn at
all times while products are in use—read product label and Material Safety Data Sheet (MSDS) for specific details. Statements & methods described are based upon the latest standard of technology known to the manufacturer. Application procedures cited are
suggestions only & are not to be interpreted as warranty for events resulting from their use. Dilution ratios are intended to provide maximum performance within the typical Volatile Organic Compound (VOC) restriction for product use. Specific VOC limits need to
be referenced to verify local compliance. Altering the solvent or dilution ratio may impact VOC compliance. User is solely responsible to ensure product use and application is in accordance with all applicable regulatory, legislative, and municipal requirements.
Click on logo to return to Table of Contents

U N D E R C O AT S

LP610 Low VOC Primer


Low VOC Primer Surfacer Application

Description: Limco LP610 Low VOC Primer is a quick cure, sandable primer that provides good sand scratch filling
with excellent adhesion and topcoat holdout. It is a 2.1 VOC compliant performance primer that
provides good filling properties.

Materials: Primer: LP610


Hardeners: LH601
LH604
LH606
Reducers: LR21
LR25
Flex Agent: 892

Substrate/Pretreatment: Cleaning Sanding Second Cleaning


Well cured old paint work R-M 909 Final Wipe P240 - P400 grit R-M 909 Final Wipe
O.E.M. primed spare parts R-M 909 Final Wipe P240 - P400 grit R-M 909 Final Wipe
Bare steel R-M 909 Final Wipe P80 - P180 grit R-M 909 Final Wipe
Then, pre-prime with LP20 or LP100
Galvanized Steel R-M 909 Final Wipe Coarse scuff pad R-M 909 Final Wipe
Then, pre-prime with LP20 or LP100
Aluminum R-M 909 Final Wipe P120 - P180 grit R-M 909 Final Wipe
Then, pre-prime with LP20 or LP100
Fiberglass plastic parts R-M 909 Final Wipe P220 grit R-M 909 Final Wipe
(without gelcoat)

NOTES: On Galvanized Steel and Aluminum, make sure sanding is not so vigorous that it removes the galvanized coating.
With the second cleaning, make sure all residue is removed. Pay special attention when cleaning Galvanized Steel and
Aluminum.

Topcoats: Supreme PLUS Low VOC Acrylic 1K Single Stage 340 gms/liter (2.8 lbs/gal) VOC
Supreme PLUS Low VOC Acrylic 1K Single Stage 420 gms/liter (3.5 lbs/gal) VOC
Supreme PLUS Low VOC Acrylic 2K Single Stage 340 gms/liter (2.8 lbs/gal) VOC
Supreme PLUS Low VOC Acrylic 2K Single Stage 420 gms/liter (3.5 lbs/gal) VOC
Supreme PLUS Low VOC Urethane Single Stage 340 gms/liter (2.8 lbs/gal) VOC
Supreme PLUS Low VOC Urethane Single Stage 420 gms/liter (3.5 lbs/gal) VOC
Supreme PLUS Low VOC Basecoat 420 gms/liter (3.5 lbs/gal) VOC

Remarks: Always check local VOC laws to ensure that the use of these Limco products is compliant in your
area.
Use an adhesion promoter when refinishing raw plastic parts.

US. Rev. 11/1/16


T E C H N I C A L D A T A

LP610 Low VOC Primer


Low VOC Primer Surfacer Application
Flexed

Mixing ratio: 8:1:2 4:1:1:1


Primer 8 parts LP610 4 parts LP610
Flex Agent — 1 part 892
Hardener 1 part LH601, LH604 or LH606 1 part LH601, LH604 or LH606
Reducer 2 parts LR21 or LR25 1 part LR21 or LR25

Potlife at 68°F/20°C 30 - 45 minutes 30 - 45 minutes

Spray viscosity Ford #4


S 13 - 18 seconds 15 - 19 seconds
@ 68°F/20°C

Gravity gun nozzle HVLP 1.5 - 1.7 mm 1.5 - 1.7 mm

Spray pressure HVLP at the cap 6 - 10 psi 6 - 10 psi

Application 2 - 3 medium wet coats 2 - 3 medium wet coats

Flash-off time @ 68°F/20°C 5 minutes between coats 5 minutes between coats

Film build 2.0 mils 2.0 mils

Coverage 678 sq. ft./gal @ 1.0 mils 763 sq. ft./gal @ 1.0 mils

Drying:
68°F/20°C 60 - 90 minutes 90 - 120 minutes
140°F/60°C 30 minutes; 30 minutes;
allow 10 minutes flash before force dry allow 10 minutes flash before force dry
Infra red short wave 5 - 7 minutes 6 - 8 minutes
Infra red medium wave N/A N/A

Sanding:
Wet by Hand P400 grit P400 grit

Dry by Hand P320 grit P320 grit

Dry by Machine P320 grit P320 grit

VOC as applied ≤ 250 gms/liter (≤ 2.1 lbs/gal) ≤ 250 gms/liter (≤ 2.1 lbs/gal)

Comments

Materials described are for application by professional trained personnel only using proper equipment. Products may be hazardous & should be used according to label directions & technical data information. Appropriate respiratory protection should be worn at
all times while products are in use—read product label and Material Safety Data Sheet (MSDS) for specific details. Statements & methods described are based upon the latest standard of technology known to the manufacturer. Application procedures cited are
suggestions only & are not to be interpreted as warranty for events resulting from their use. Dilution ratios are intended to provide maximum performance within the typical Volatile Organic Compound (VOC) restriction for product use. Specific VOC limits need to
be referenced to verify local compliance. Altering the solvent or dilution ratio may impact VOC compliance. User is solely responsible to ensure product use and application is in accordance with all applicable regulatory, legislative, and municipal requirements.
Click on logo to return to Table of Contents

U N D E R C O AT S

LP610 Low VOC Primer


Low VOC Sealer Application

Description: Limco LP610 Low VOC Primer is a quick cure, sandable primer that provides good sand scratch filling
with excellent adhesion and topcoat holdout. It is a 2.1 VOC compliant performance primer that
provides good filling properties.

Materials: Primer: LP610


Hardeners: LH601
LH604
LH606
Reducers: LR21
LR25
Flex Agent: 892

Substrate/Pretreatment: Cleaning Sanding Second Cleaning


Well cured old paint work R-M 909 Final Wipe P240 - P400 grit R-M 909 Final Wipe
O.E.M. primed spare parts R-M 909 Final Wipe P240 - P400 grit R-M 909 Final Wipe
Bare steel R-M 909 Final Wipe P80 - P180 grit R-M 909 Final Wipe
Then, pre-prime with LP20 or LP100
Galvanized Steel R-M 909 Final Wipe Coarse scuff pad R-M 909 Final Wipe
Then, pre-prime with LP20 or LP100
Aluminum R-M 909 Final Wipe P120 - P180 grit R-M 909 Final Wipe
Then, pre-prime with LP20 or LP100
Fiberglass plastic parts R-M 909 Final Wipe P220 grit R-M 909 Final Wipe
(without gelcoat)

NOTES: On Galvanized Steel and Aluminum, make sure sanding is not so vigorous that it removes the galvanized coating.
With the second cleaning, make sure all residue is removed. Pay special attention when cleaning Galvanized Steel and
Aluminum.

Topcoats: Supreme PLUS Low VOC Acrylic 1K Single Stage 340 gms/liter (2.8 lbs/gal) VOC
Supreme PLUS Low VOC Acrylic 1K Single Stage 420 gms/liter (3.5 lbs/gal) VOC
Supreme PLUS Low VOC Acrylic 2K Single Stage 340 gms/liter (2.8 lbs/gal) VOC
Supreme PLUS Low VOC Acrylic 2K Single Stage 420 gms/liter (3.5 lbs/gal) VOC
Supreme PLUS Low VOC Urethane Single Stage 340 gms/liter (2.8 lbs/gal) VOC
Supreme PLUS Low VOC Urethane Single Stage 420 gms/liter (3.5 lbs/gal) VOC
Supreme PLUS Low VOC Basecoat 420 gms/liter (3.5 lbs/gal) VOC

Remarks: Always check local VOC laws to ensure that the use of these Limco products is compliant in your
area.
Use an adhesion promoter when refinishing raw plastic parts.

US. Rev. 11/1/16


T E C H N I C A L D A T A

LP610 Low VOC Primer


Low VOC Sealer Application
Flexed

Mixing ratio: 8:1:4 4:1:1:2


Primer 8 parts LP610 4 parts LP610
Flex Agent — 1 part 892
Hardener 1 part LH601, LH604 or LH606 1 part LH601, LH604 or LH606
Reducer 4 parts LR21 or LR25 2 parts LR21 or LR25

Potlife at 68°F/20°C 45 - 60 minutes 30 - 45 minutes

Spray viscosity Ford #4


S 12 - 15 seconds 13 - 16 seconds
@ 68°F/20°C

Gravity gun nozzle HVLP 1.5 mm 1.5 - 1.6 mm

Spray pressure HVLP at the cap 6 - 10 psi 6 - 10 psi

Application 2 - 3 medium wet coats 1 - 2 medium wet coats

Flash-off time @ 68°F/20°C 5 minutes between coats 5 minutes between coats

Film build 1.0 - 1.5 mils 1.0 - 1.5 mils

Coverage 574 sq. ft./gal @ 1.0 mils 667 sq. ft./gal @ 1.0 mils

Drying:
68°F/20°C 30 minutes flash before topcoating 30 minutes flash before topcoating
140°F/60°C N/A N/A
Infra red short wave N/A N/A
Infra red medium wave N/A N/A

Sanding:
Wet by Hand N/A N/A

Dry by Hand N/A N/A

Dry by Machine N/A N/A

VOC as applied ≤ 250 gms/liter (≤ 2.1 lbs/gal) ≤ 250 gms/liter (≤ 2.1 lbs/gal)

Comments

Materials described are for application by professional trained personnel only using proper equipment. Products may be hazardous & should be used according to label directions & technical data information. Appropriate respiratory protection should be worn at
all times while products are in use—read product label and Material Safety Data Sheet (MSDS) for specific details. Statements & methods described are based upon the latest standard of technology known to the manufacturer. Application procedures cited are
suggestions only & are not to be interpreted as warranty for events resulting from their use. Dilution ratios are intended to provide maximum performance within the typical Volatile Organic Compound (VOC) restriction for product use. Specific VOC limits need to
be referenced to verify local compliance. Altering the solvent or dilution ratio may impact VOC compliance. User is solely responsible to ensure product use and application is in accordance with all applicable regulatory, legislative, and municipal requirements.
Click on logo to return to Table of Contents

U N D E R C O AT S

LP620 Low VOC Primer


U.S. National Rule Primer Surfacer Application

Description: Limco LP620 Low VOC Primer in this National Rule presentation is a quick cure, sandable primer
that provides good sand scratch filling with excellent adhesion and topcoat holdout. It is a National
Rule compliant performance primer that provides good filling properties.

Materials: Primer: LP620


Hardeners: LHF
LHM
LHS
Reducers: LR10
LR11
LR12
LR13
LR15

Substrate/Pretreatment: Cleaning Sanding Second Cleaning


Well cured old paint work 203 Wax and Grease Remover P240 - P400 grit 139 Final Wash Cleaner
O.E.M. primed spare parts 203 Wax and Grease Remover P240 - P400 grit 139 Final Wash Cleaner
Bare steel 203 Wax and Grease Remover P80 - P180 grit 139 Final Wash Cleaner
Galvanized Steel 203 Wax and Grease Remover Coarse scuff pad 139 Final Wash Cleaner
Then, pre-prime with LP20 or LP100
Aluminum 203 Wax and Grease Remover P120 - P180 grit 139 Final Wash Cleaner
Then, pre-prime with LP20 or LP100
Fiberglass plastic parts R-M 902 Plastic Prep-Cleaner P220 grit R-M 902 Plastic Prep-Cleaner
(without gelcoat)

NOTES: On Galvanized Steel and Aluminum, make sure sanding is not so vigorous that it removes the galvanized coating.
With the second cleaning, make sure all residue is removed. Pay special attention when cleaning Galvanized Steel and
Aluminum.

Topcoats: Supreme PLUS Acrylic 1K Single Stage


Supreme PLUS Acrylic 2K Single Stage
Supreme PLUS Urethane Single Stage
Supreme PLUS Basecoat

Remarks: Always check local VOC laws to ensure that the use of these Limco products is compliant in your
area.
Use an adhesion promoter when refinishing raw plastic parts.

US. Rev. 11/1/16


T E C H N I C A L D A T A

LP620 Low VOC Primer


U.S. National Rule Primer Surfacer Application
Mixing ratio: 4:1:1
Primer 4 parts LP620
Hardener 1 part LHF, LHM or LHS
Reducer 1 part LR10, LR11, LR12, LR13 or LR15

Potlife at 68°F/20°C 45 minutes

Spray viscosity Ford #4


S 16 - 20 seconds
@ 68°F/20°C

Gravity gun nozzle HVLP 1.5 - 1.7 mm

Spray pressure HVLP at the cap 6 - 10 psi

Application 1 - 2 medium wet coats

Flash-off time @ 68°F/20°C 5 minutes

Film build 2.0 - 3.0 mils

Coverage 697 sq. ft./gal @ 1.0 mils

Drying:
68°F/20°C 60 - 90 minutes
140°F/60°C 30 - 40 minutes; allow 10 minutes flash before force drying.
Infra red short wave 5 - 7 minutes
Infra red medium wave N/A

Sanding:
Wet by Hand P400 grit

Dry by Hand P320 grit

Dry by Machine P320 grit

VOC as applied ≤ 580 gms/liter (≤ 4.8 lbs/gal)

Comments

Materials described are for application by professional trained personnel only using proper equipment. Products may be hazardous & should be used according to label directions & technical data information. Appropriate respiratory protection should be worn at
all times while products are in use—read product label and Material Safety Data Sheet (MSDS) for specific details. Statements & methods described are based upon the latest standard of technology known to the manufacturer. Application procedures cited are
suggestions only & are not to be interpreted as warranty for events resulting from their use. Dilution ratios are intended to provide maximum performance within the typical Volatile Organic Compound (VOC) restriction for product use. Specific VOC limits need to
be referenced to verify local compliance. Altering the solvent or dilution ratio may impact VOC compliance. User is solely responsible to ensure product use and application is in accordance with all applicable regulatory, legislative, and municipal requirements.
Click on logo to return to Table of Contents

U N D E R C O AT S

LP620 Low VOC Primer


Low VOC Primer Surfacer Application

Description: Limco LP620 Low VOC Primer is a quick cure, sandable primer that provides good sand scratch filling
with excellent adhesion and topcoat holdout. It is a 2.1 VOC compliant performance primer that
provides good filling properties.

Materials: Primer: LP620


Hardeners: LH601
LH604
LH606
Reducers: LR21
LR25

Substrate/Pretreatment: Cleaning Sanding Second Cleaning


Well cured old paint work R-M 909 Final Wipe P240 - P400 grit R-M 909 Final Wipe
O.E.M. primed spare parts R-M 909 Final Wipe P240 - P400 grit R-M 909 Final Wipe
Bare steel R-M 909 Final Wipe P80 - P180 grit R-M 909 Final Wipe
Then, pre-prime with LP20 or LP100
Galvanized Steel R-M 909 Final Wipe Coarse scuff pad R-M 909 Final Wipe
Then, pre-prime with LP20 or LP100
Aluminum R-M 909 Final Wipe P120 - P180 grit R-M 909 Final Wipe
Then, pre-prime with LP20 or LP100
Fiberglass plastic parts R-M 909 Final Wipe P220 grit R-M 909 Final Wipe
(without gelcoat)

NOTES: On Galvanized Steel and Aluminum, make sure sanding is not so vigorous that it removes the galvanized coating.
With the second cleaning, make sure all residue is removed. Pay special attention when cleaning Galvanized Steel and
Aluminum.

Topcoats: Supreme PLUS Low VOC Acrylic 1K Single Stage 340 gms/liter (2.8 lbs/gal) VOC
Supreme PLUS Low VOC Acrylic 1K Single Stage 420 gms/liter (3.5 lbs/gal) VOC
Supreme PLUS Low VOC Acrylic 2K Single Stage 340 gms/liter (2.8 lbs/gal) VOC
Supreme PLUS Low VOC Acrylic 2K Single Stage 420 gms/liter (3.5 lbs/gal) VOC
Supreme PLUS Low VOC Urethane Single Stage 340 gms/liter (2.8 lbs/gal) VOC
Supreme PLUS Low VOC Urethane Single Stage 420 gms/liter (3.5 lbs/gal) VOC
Supreme PLUS Low VOC Basecoat 420 gms/liter (3.5 lbs/gal) VOC

Remarks: Always check local VOC laws to ensure that the use of these Limco products is compliant in your
area.
Use an adhesion promoter when refinishing raw plastic parts.

US. Rev. 11/1/16


T E C H N I C A L D A T A

LP620 Low VOC Primer


Low VOC Primer Surfacer Application
Mixing ratio: 4:1:1
Primer 4 parts LP620
Hardener 1 part LH601, LH604 or LH606
Reducer 1 part LR21 or LR25

Potlife at 68°F/20°C 45 minutes

Spray viscosity Ford #4


S 16 - 20 seconds
@ 68°F/20°C

Gravity gun nozzle HVLP 1.5 - 1.7 mm

Spray pressure HVLP at the cap 6 - 10 psi

Application 1 - 2 medium wet coats

Flash-off time @ 68°F/20°C 5 minutes

Film build 2.0 - 3.0 mils

Coverage 719 sq. ft./gal @ 1.0 mils

Drying:
68°F/20°C 60 - 90 minutes
140°F/60°C 30 - 40 minutes; allow 10 minutes flash before force drying.
Infra red short wave 5 - 7 minutes
Infra red medium wave N/A

Sanding:
Wet by Hand P400 grit

Dry by Hand P320 grit

Dry by Machine P320 grit

VOC as applied ≤ 250 gms/liter (≤ 2.1 lbs/gal)

Comments

Materials described are for application by professional trained personnel only using proper equipment. Products may be hazardous & should be used according to label directions & technical data information. Appropriate respiratory protection should be worn at
all times while products are in use—read product label and Material Safety Data Sheet (MSDS) for specific details. Statements & methods described are based upon the latest standard of technology known to the manufacturer. Application procedures cited are
suggestions only & are not to be interpreted as warranty for events resulting from their use. Dilution ratios are intended to provide maximum performance within the typical Volatile Organic Compound (VOC) restriction for product use. Specific VOC limits need to
be referenced to verify local compliance. Altering the solvent or dilution ratio may impact VOC compliance. User is solely responsible to ensure product use and application is in accordance with all applicable regulatory, legislative, and municipal requirements.
Click on logo to return to Table of Contents

U N D E R C O AT S

LP620 Low VOC Primer


U.S. National Rule Sealer Application

Description: Limco LP620 Low VOC Primer in this National Rule presentation is a quick cure, sandable primer
that provides good sand scratch filling with excellent adhesion and topcoat holdout. It is a National
Rule compliant performance primer that provides good filling properties.

Materials: Primer: LP620


Hardeners: LHF
LHM
LHS
Reducers: LR10
LR11
LR12
LR13
LR15
Flex Agent: 892

Substrate/Pretreatment: Cleaning Sanding Second Cleaning


Well cured old paint work 203 Wax and Grease Remover P240 - P400 grit 139 Final Wash Cleaner
O.E.M. primed spare parts 203 Wax and Grease Remover P240 - P400 grit 139 Final Wash Cleaner
Bare steel 203 Wax and Grease Remover P80 - P180 grit 139 Final Wash Cleaner
Galvanized Steel 203 Wax and Grease Remover Coarse scuff pad 139 Final Wash Cleaner
Then, pre-prime with LP20 or LP100
Aluminum 203 Wax and Grease Remover P120 - P180 grit 139 Final Wash Cleaner
Then, pre-prime with LP20 or LP100
Fiberglass plastic parts R-M 902 Plastic Prep-Cleaner P220 grit R-M 902 Plastic Prep-Cleaner
(without gelcoat)

NOTES: On Galvanized Steel and Aluminum, make sure sanding is not so vigorous that it removes the galvanized coating.
With the second cleaning, make sure all residue is removed. Pay special attention when cleaning Galvanized Steel and
Aluminum.

Topcoats: Supreme PLUS Acrylic 1K Single Stage


Supreme PLUS Acrylic 2K Single Stage
Supreme PLUS Urethane Single Stage
Supreme PLUS Basecoat

Remarks: Always check local VOC laws to ensure that the use of these Limco products is compliant in your
area.
Use an adhesion promoter when refinishing raw plastic parts.

US. Rev. 11/1/16


T E C H N I C A L D A T A

LP620 Low VOC Primer


U.S. National Rule Sealer Application
Flexed Tinted

Mixing ratio: 4:1:2 4:1:1:2 4:4:1:2


Primer 4 parts LP620 4 parts LP620 4 parts LP620
Color — — 4 parts LA Base
Flex Agent ­— 1 part 892 —
Hardener 1 part LHF, LHM or LHS 1 part LHF, LHM or LHS 1 part LHF, LHM or LHS
Reducer 2 parts LR10, LR11, LR12, 2 parts LR10, LR11, LR12, 2 parts LR10, LR11, LR12,
LR13 or LR15 LR13 or LR15 LR13 or LR15

Potlife at 68°F/20°C 60 minutes 90 minutes 60 minutes

Spray viscosity Ford #4


S 13 - 16 seconds 13 - 16 seconds 13 - 16 seconds
@ 68°F/20°C

Gravity gun nozzle HVLP 1.3 - 1.5 mm 1.3 - 1.5 mm 1.3 - 1.5 mm

Spray pressure HVLP at the cap 6 - 10 psi 6 - 10 psi 6 - 10 psi

Application 1 medium wet coat 1 medium wet coat 1 medium wet coat

Flash-off time @ 68°F/20°C N/A N/A N/A

Film build 1.0 - 1.5 mils 1.0 - 1.5 mils 1.0 - 1.5 mils

Coverage 597 sq. ft./gal @ 1.0 mils 651 sq. ft./gal @ 1.0 mils 608 sq. ft./gal @ 1.0 mils

Drying:
68°F/20°C 30 minutes flash before 30 minutes flash before 30 minutes flash before
topcoating topcoating topcoating
140°F/60°C N/A N/A N/A
Infra red short wave N/A N/A N/A
Infra red medium wave N/A N/A N/A

Sanding:
Wet by Hand N/A N/A N/A

Dry by Hand N/A N/A N/A

Dry by Machine N/A N/A N/A

≤ 550 gms/liter ≤ 550 gms/liter ≤ 550 gms/liter


VOC as applied
(≤ 4.6 lbs/gal) (≤ 4.6 lbs/gal) (≤ 4.6 lbs/gal)

Comments

Materials described are for application by professional trained personnel only using proper equipment. Products may be hazardous & should be used according to label directions & technical data information. Appropriate respiratory protection should be worn at
all times while products are in use—read product label and Material Safety Data Sheet (MSDS) for specific details. Statements & methods described are based upon the latest standard of technology known to the manufacturer. Application procedures cited are
suggestions only & are not to be interpreted as warranty for events resulting from their use. Dilution ratios are intended to provide maximum performance within the typical Volatile Organic Compound (VOC) restriction for product use. Specific VOC limits need to
be referenced to verify local compliance. Altering the solvent or dilution ratio may impact VOC compliance. User is solely responsible to ensure product use and application is in accordance with all applicable regulatory, legislative, and municipal requirements.
Click on logo to return to Table of Contents

U N D E R C O AT S

LP620 Low VOC Primer


Low VOC Sealer Application

Description: Limco LP620 Low VOC Primer is a 2.1 VOC compliant performance sealer that provides good filling
properties and quick drying with good melt-in and topcoat holdout..

Materials: Primer: LP620


Hardeners: LH601
LH604
LH606
Reducers: LR21
LR25
Flex Agent: 892

Substrate/Pretreatment: Cleaning Sanding Second Cleaning


Well cured old paint work R-M 909 Final Wipe P240 - P400 grit R-M 909 Final Wipe
O.E.M. primed spare parts R-M 909 Final Wipe P240 - P400 grit R-M 909 Final Wipe
Bare steel R-M 909 Final Wipe P80 - P180 grit R-M 909 Final Wipe
Then, pre-prime with LP20 or LP100
Galvanized Steel R-M 909 Final Wipe Coarse scuff pad R-M 909 Final Wipe
Then, pre-prime with LP20 or LP100
Aluminum R-M 909 Final Wipe P120 - P180 grit R-M 909 Final Wipe
Then, pre-prime with LP20 or LP100
Fiberglass plastic parts R-M 909 Final Wipe P220 grit R-M 909 Final Wipe
(without gelcoat)

NOTES: On Galvanized Steel and Aluminum, make sure sanding is not so vigorous that it removes the galvanized coating.
With the second cleaning, make sure all residue is removed. Pay special attention when cleaning Galvanized Steel and
Aluminum.

Topcoats: Supreme PLUS Low VOC Acrylic 1K Single Stage 340 gms/liter (2.8 lbs/gal) VOC
Supreme PLUS Low VOC Acrylic 1K Single Stage 420 gms/liter (3.5 lbs/gal) VOC
Supreme PLUS Low VOC Acrylic 2K Single Stage 340 gms/liter (2.8 lbs/gal) VOC
Supreme PLUS Low VOC Acrylic 2K Single Stage 420 gms/liter (3.5 lbs/gal) VOC
Supreme PLUS Low VOC Urethane Single Stage 340 gms/liter (2.8 lbs/gal) VOC
Supreme PLUS Low VOC Urethane Single Stage 420 gms/liter (3.5 lbs/gal) VOC
Supreme PLUS Low VOC Basecoat 420 gms/liter (3.5 lbs/gal) VOC

Remarks: Always check local VOC laws to ensure that the use of these Limco products is compliant in your
area.
Use an adhesion promoter when refinishing raw plastic parts.

US. Rev. 11/1/16


T E C H N I C A L D A T A

LP620 Low VOC Primer


Low VOC Sealer Application
Flexed

Mixing ratio: 4:1:2 4:1:1:2


Primer 4 parts LP620 4 parts LP620
Flex Agent — 1 part 892
Hardener 1 part LH601, LH604 or LH606 1 part LH601, LH604 or LH606
Reducer 2 parts LR21 or LR25 2 parts LR21 or LR25

Potlife at 68°F/20°C 60 minutes 90 minutes

Spray viscosity Ford #4


S 13 - 16 seconds 13 - 16 seconds
@ 68°F/20°C

Gravity gun nozzle HVLP 1.3 - 1.5 mm 1.3 - 1.5 mm

Spray pressure HVLP at the cap 6 - 10 psi 6 - 10 psi

Application 1 medium wet coat 1 medium wet coat

Flash-off time @ 68°F/20°C N/A N/A

Film build 1.0 - 1.5 mils 1.0 - 1.5 mils

Coverage 616 sq. ft./gal @ 1.0 mils 668 sq. ft./gal @ 1.0 mils

Drying:
68°F/20°C 30 minutes flash before topcoating 30 minutes flash before topcoating
140°F/60°C N/A N/A
Infra red short wave N/A N/A
Infra red medium wave N/A N/A

Sanding:
Wet by Hand N/A N/A

Dry by Hand N/A N/A

Dry by Machine N/A N/A

VOC as applied ≤ 250 gms/liter (≤ 2.1 lbs/gal) ≤ 250 gms/liter (≤ 2.1 lbs/gal)

Comments

Materials described are for application by professional trained personnel only using proper equipment. Products may be hazardous & should be used according to label directions & technical data information. Appropriate respiratory protection should be worn at
all times while products are in use—read product label and Material Safety Data Sheet (MSDS) for specific details. Statements & methods described are based upon the latest standard of technology known to the manufacturer. Application procedures cited are
suggestions only & are not to be interpreted as warranty for events resulting from their use. Dilution ratios are intended to provide maximum performance within the typical Volatile Organic Compound (VOC) restriction for product use. Specific VOC limits need to
be referenced to verify local compliance. Altering the solvent or dilution ratio may impact VOC compliance. User is solely responsible to ensure product use and application is in accordance with all applicable regulatory, legislative, and municipal requirements.
Click on logo to return to Table of Contents

U N D E R C O AT S

LS56 1K Sealer
U.S. National Rule Wet-On-Wet Sealer Application

Description: Limco LS56 1K Sealer is a fast drying sealer that provides excellent adhesion with good topcoat
color hold out.

Materials: Sealer: LS56


Reducer: LR21

Substrate/Pretreatment: Cleaning Sanding Second Cleaning


Well cured old paint work 203 Wax and Grease Remover P240 - P400 grit 139 Final Wash Cleaner
O.E.M. primed spare parts 203 Wax and Grease Remover P240 - P400 grit 139 Final Wash Cleaner
Bare steel 203 Wax and Grease Remover P80 - P180 grit 139 Final Wash Cleaner
Then, Pre-prime with LP20 or LP100
Galvanized Steel 203 Wax and Grease Remover Coarse scuff pad 139 Final Wash Cleaner
Then, pre-prime with LP20 or LP100
Aluminum 203 Wax and Grease Remover P120 - P180 grit 139 Final Wash Cleaner
Then, pre-prime with LP20 or LP100
Fiberglass (with gelcoat) R-M 902 Plastic Prep-Cleaner P220 grit R-M 902 Plastic Prep-Cleaner

NOTES: On Galvanized Steel and Aluminum, make sure sanding is not so vigorous that it removes the galvanized coating.
With the second cleaning, make sure all residue is removed. Pay special attention when cleaning Galvanized Steel and
Aluminum.

Topcoats: Supreme PLUS Acrylic 1K Single Stage


Supreme PLUS Acrylic 2K Single Stage
Supreme PLUS Urethane Single Stage
Supreme PLUS Basecoat

Remarks: Always check local VOC laws to ensure that the use of these Limco products is compliant in your
area.

US. Rev. 11/1/16


T E C H N I C A L D A T A

LS56 1K Sealer
U.S. National Rule Wet-On-Wet Sealer Application
Mixing ratio: 2:1
Sealer 2 parts LS56
Reducer 1 part LR21

Potlife at 68°F/20°C N/A

Spray viscosity Ford #4


S 12 - 14 seconds
@ 68°F/20°C

Gravity gun nozzle HVLP 1.5 - 1.7 mm

Spray pressure HVLP at the cap 8 - 10 psi

Application 1 medium wet coat

Flash-off time @ 68°F/20°C 30 minutes; 10 hours (max.)

Film build 0.5 - 0.8 mils

Coverage 421 sq. ft./gal @ 1.0 mils

Drying:
68°F/20°C 30 minutes
140°F/60°C N/A
Infra red short wave N/A
Infra red medium wave N/A

Sanding:
Wet by Hand N/A

Dry by Hand N/A

Dry by Machine N/A

VOC as applied ≤ 550 gms/liter (≤ 4.6 lbs/gal)

Comments

Materials described are for application by professional trained personnel only using proper equipment. Products may be hazardous & should be used according to label directions & technical data information. Appropriate respiratory protection should be worn at
all times while products are in use—read product label and Material Safety Data Sheet (MSDS) for specific details. Statements & methods described are based upon the latest standard of technology known to the manufacturer. Application procedures cited are
suggestions only & are not to be interpreted as warranty for events resulting from their use. Dilution ratios are intended to provide maximum performance within the typical Volatile Organic Compound (VOC) restriction for product use. Specific VOC limits need to
be referenced to verify local compliance. Altering the solvent or dilution ratio may impact VOC compliance. User is solely responsible to ensure product use and application is in accordance with all applicable regulatory, legislative, and municipal requirements.
Click on logo to return to Table of Contents

U N D E R C O AT S

LS800 2K Sealer
U.S. National Rule Wet-On-Wet Sealer Application

Description: The LS800 2K Sealer is a tintable wet-on-wet sealer that dries quickly and provides excellent
adhesion. LS800 2K Sealer can be tinted using Limco Supreme PLUS bases.

Materials: Sealer: LS800


Supreme Bases: LA Bases
Hardeners: LHF
LHM
Reducers: LR10
LR11
LR12
LR13
Flex Agent: 892

Substrate/Pretreatment: Cleaning Sanding Second Cleaning


Well cured old paint work 203 Wax and Grease Remover P240 - P400 grit 139 Final Wash Cleaner
O.E.M. primed spare parts 203 Wax and Grease Remover P240 - P400 grit 139 Final Wash Cleaner
Bare steel 203 Wax and Grease Remover P80 - P180 grit 139 Final Wash Cleaner
Galvanized Steel 203 Wax and Grease Remover Coarse scuff pad 139 Final Wash Cleaner
Then, pre-prime with LP20 or LP100
Aluminum 203 Wax and Grease Remover P120 - P180 grit 139 Final Wash Cleaner
Then, pre-prime with LP20 or LP100
Fiberglass plastic parts R-M 902 Plastic Prep-Cleaner P220 grit R-M 902 Plastic Prep-Cleaner
(without gelcoat)

NOTES: On Galvanized Steel and Aluminum, make sure sanding is not so vigorous that it removes the galvanized coating.
With the second cleaning, make sure all residue is removed. Pay special attention when cleaning Galvanized Steel and
Aluminum.

Topcoats: Supreme PLUS Acrylic 1K Single Stage


Supreme PLUS Acrylic 2K Single Stage
Supreme PLUS Urethane Single Stage
Supreme PLUS Basecoat

Remarks: Always check local VOC laws to ensure that the use of these Limco products is compliant in your
area.
Do not use mixed color to tint LS800. Tint LS800 with LA bases only.
Do not force dry LS800, wet-on- wet application.

US. Rev. 11/1/16


T E C H N I C A L D A T A

LS800 2K Sealer
U.S. National Rule Wet-On-Wet Sealer Application
Untinted Tinted
Mixing ratio: 4:1:2 4:1:1:2
Primer 4 parts LS800 4 parts LS800
Color — 1 part LA Base
Hardener 1 part LHF or LHM 1 part LHF or LHM
Reducer 2 parts LR10, LR11, LR12 or LR13 2 parts LR10, LR11, LR12 or LR13

Potlife at 68°F/20°C 45 - 60 minutes 45 - 60 minutes

Spray viscosity Ford #4


S 13 - 15 seconds 13 - 15 seconds
@ 68°F/20°C

Gravity gun nozzle HVLP 1.4 - 1.5 mm 1.4 - 1.5 mm

Spray pressure HVLP at the cap 8 - 10 psi 8 - 10 psi

Application 1 - 2 medium wet coats 1 - 2 medium wet coats

Flash-off time @ 68°F/20°C 15 minutes 30 minutes

Film build 1.0 - 1.5 mils 1.0 - 1.5 mils

Coverage 590 sq. ft./gal @ 1.0 mils 597 sq. ft./gal @ 1.0 mils

Drying:
68°F/20°C 15 minutes (no longer than 30 minutes (no longer than
3 hours before topcoat) 4 hours before topcoat)
140°F/60°C N/A N/A
Infra red short wave N/A N/A
Infra red medium wave N/A N/A

Sanding:
Wet by Hand N/A N/A

Dry by Hand N/A N/A

Dry by Machine N/A N/A

VOC as applied ≤ 550 gms/liter (≤ 4.6 lbs/gal) ≤ 550 gms/liter (≤ 4.6 lbs/gal)

Comments For flexible plastic parts:


4 parts LS800
1 part 892
1 additional part of hardener
Then follow appropriate tinted or untinted
mix ratio.

Materials described are for application by professional trained personnel only using proper equipment. Products may be hazardous & should be used according to label directions & technical data information. Appropriate respiratory protection should be worn at
all times while products are in use—read product label and Material Safety Data Sheet (MSDS) for specific details. Statements & methods described are based upon the latest standard of technology known to the manufacturer. Application procedures cited are
suggestions only & are not to be interpreted as warranty for events resulting from their use. Dilution ratios are intended to provide maximum performance within the typical Volatile Organic Compound (VOC) restriction for product use. Specific VOC limits need to
be referenced to verify local compliance. Altering the solvent or dilution ratio may impact VOC compliance. User is solely responsible to ensure product use and application is in accordance with all applicable regulatory, legislative, and municipal requirements.
Click on logo to return to Table of Contents

U N D E R C O AT S

PS21nr 1K Gray Sealer


U.S. National Rule Wet-On-Wet Sealer Application

Description: Limco PS21nr 1K Gray Sealer improves color hold-out and eliminates sand scratch swelling. This
sealer is non-sanding, fast drying and ensures excellent adhesion.

Materials: Sealer: PS21nr

Substrate/Pretreatment: Cleaning Sanding Second Cleaning


Well cured old paint work 203 Wax and Grease Remover P240 - P400 grit 139 Final Wash Cleaner
O.E.M. primed spare parts 203 Wax and Grease Remover P240 - P400 grit 139 Final Wash Cleaner
Bare steel 203 Wax and Grease Remover P80 - P180 grit 139 Final Wash Cleaner
Then, pre-prime with LP20 or LP100
Galvanized Steel 203 Wax and Grease Remover Coarse scuff pad 139 Final Wash Cleaner
Then, pre-prime with LP20 or LP100
Aluminum 203 Wax and Grease Remover P120 - P180 grit 139 Final Wash Cleaner
Then, pre-prime with LP20 or LP100
Fiberglass plastic parts PS21nr is not recommended under this substrate
(without gelcoat)

NOTES: On Galvanized Steel and Aluminum, make sure sanding is not so vigorous that it removes the galvanized coating.
With the second cleaning, make sure all residue is removed. Pay special attention when cleaning Galvanized Steel and
Aluminum.

Topcoats: Supreme PLUS Acrylic 1K Single Stage


Supreme PLUS Acrylic 2K Single Stage
Supreme PLUS Urethane Single Stage
Supreme PLUS Basecoat

Remarks: Always check local VOC laws to ensure that the use of these Limco products is compliant in your
area.

US. Rev. 11/1/16


T E C H N I C A L D A T A

PS21nr 1K Gray Sealer


U.S. National Rule Wet-on-Wet Sealer Application
Mixing ratio: Ready for use
Sealer PS21nr

Potlife at 68°F/20°C N/A

Spray viscosity Ford #4


S 13 seconds
@ 68°F/20°C

Gravity gun nozzle HVLP 1.5 mm

Spray pressure HVLP at the cap 10 psi

Application 1 - 2 light coats

Flash-off time @ 68°F/20°C 5 to 10 minutes between coats

Film build 0.5 - 1.0 mils

Coverage 445 sq. ft./gal @ 1.0 mils

Drying:
68°F/20°C 20 minutes
140°F/60°C N/A
Infra red short wave N/A
Infra red medium wave N/A

Sanding:
Wet by Hand N/A

Dry by Hand N/A

Dry by Machine N/A

VOC as applied ≤ 550 gms/liter (≤ 4.6 lbs/gal)


If allowed to dry overnight, sand with P400 grit then, clean with 139 Final Wash Cleaner
Comments
to remove sanding residue prior to topcoating.

Materials described are for application by professional trained personnel only using proper equipment. Products may be hazardous & should be used according to label directions & technical data information. Appropriate respiratory protection should be worn at
all times while products are in use—read product label and Material Safety Data Sheet (MSDS) for specific details. Statements & methods described are based upon the latest standard of technology known to the manufacturer. Application procedures cited are
suggestions only & are not to be interpreted as warranty for events resulting from their use. Dilution ratios are intended to provide maximum performance within the typical Volatile Organic Compound (VOC) restriction for product use. Specific VOC limits need to
be referenced to verify local compliance. Altering the solvent or dilution ratio may impact VOC compliance. User is solely responsible to ensure product use and application is in accordance with all applicable regulatory, legislative, and municipal requirements.
Click on logo to return to Table of Contents

T O P C O AT S

Supreme PLUS
Acrylic 1K Single Stage
U.S. National Rule VOC

Description: Limco Supreme PLUS U.S. National Rule Topcoat is a specially formulated Acrylic 1K Single Stage
system designed to meet the rigorous demands of Refinish, Commercial Vehicle, Agricultural
and Fleet markets. Limco Supreme PLUS U.S. National Rule Acrylic 1K Single Stage Topcoat dries
quickly to a dust-free surface with excellent flow and leveling, good hiding and good gloss.

Materials: Supreme Bases: LA & LIB Bases


Supreme Grab & Go Colors: G Bases
Acrylic 1K Mixing Clear: LA4999
Reducers: LR10
LR11
LR12
LR13
LR15

Substrates prepared
for topcoating: Finish Sanding
Well cured old paint work P500 grit
Primer Surfacer 800K P320 - P500 grit
Primer Surfacer 846 P320 - P500 grit
Primer Surfacer LP20 P320 - P500 grit
Primer Surfacer LP620 P320 - P500 grit
Primer Sealer LP20 Sanding not required
Primer Sealer LP620 Sanding not required
Primer Sealer LS56 Sanding not required
Primer Sealer LS800 Sanding not required
Primer Sealer PS21NR Sanding not required

Remarks: Always check local VOC laws to ensure that the use of these Limco products is compliant in your
area.
To retrieve color information from BASF color retrieval software, use paint line SA1K.
For custom Supreme PLUS Acrylic 1K (600 gms/liter) colors, the color (LA, LIB, G bases) must be
mixed 1 part to 1 part of LA4999 by volume prior to addition of reducer.
OPTIONAL: For a more durable finish, Limco Hardener LHF, LHM or LHS may be added at a ratio
of 10:1 with 1 part of reducer. Caution: Lighter colors may yellow with the addition of hardener.
Adding hardener will result in a four hour pot life.

US Rev. 11/1/16
T E C H N I C A L D A T A

Supreme PLUS
Acrylic 1K Single Stage
U.S. National Rule VOC
Mixing ratio: 8:1
Color 8 parts Color
Reducer 1 part LR10, LR11, LR12, LR13 or LR15

Potlife at 68°F/20°C N/A

Spray viscosity Ford #4


S 14 - 18 seconds
@ 68°F/20°C

Gravity gun nozzle HVLP 1.3 - 1.7 mm

Spray pressure HVLP at the cap 6 - 10 psi

Application 2 - 3 wet coats

Flash-off time @ 68°F/20°C 5 minutes between coats

Film build 2.0 - 3.0 mils

Coverage 540 - 590 sq. ft./gal @ 1.0 mils

Drying:
68°F/20°C 30 - 45 minutes dust free;
2 - 4 hours tack free
140°F/60°C 30 minutes
Infra red short wave N/A
Infra red medium wave N/A

Sanding:
Wet by Hand N/A

Dry by Hand N/A

Dry by Machine N/A

VOC as applied ≤ 600 gms/liter (≤ 5.0 lbs/gal)

Comments Shake new tinting bases for 15 minutes using a mechanical paint shaker before placing
on a mixing machine.
Tinting bases on a mixing machine need to be agitated for 15 minutes at the start of
the work day and every 4 hours during the day to ensure good color matching.
For areas requiring recoating four or more hours after application:
Scuff with a fine scuff pad (Scotchbrite #7447).
Cleaning: Use an air blow gun to remove all traces of dust and dirt from the cracks and
surfaces of the vehicle.
Clean all areas to be painted with 139 Final Wipe Cleaner.

Materials described are for application by professional trained personnel only using proper equipment. Products may be hazardous & should be used according to label directions & technical data information. Appropriate respiratory protection should be worn at
all times while products are in use—read product label and Material Safety Data Sheet (MSDS) for specific details. Statements & methods described are based upon the latest standard of technology known to the manufacturer. Application procedures cited are
suggestions only & are not to be interpreted as warranty for events resulting from their use. Dilution ratios are intended to provide maximum performance within the typical Volatile Organic Compound (VOC) restriction for product use. Specific VOC limits need to
be referenced to verify local compliance. Altering the solvent or dilution ratio may impact VOC compliance. User is solely responsible to ensure product use and application is in accordance with all applicable regulatory, legislative, and municipal requirements.
Click on logo to return to Table of Contents

T O P C O AT S

Supreme PLUS
Low VOC Acrylic 1K Single Stage
340 gms/liter (2.8 lbs/gal) VOC
420 gms/liter (3.5 lbs/gal) VOC

Description: Limco Supreme PLUS Low VOC Topcoat is a specially formulated Acrylic 1K Single Stage system
designed to meet the rigorous demands of Refinish, Commercial Vehicle, Agricultural and Fleet
markets. Limco Supreme PLUS Low VOC Acrylic 1K Single Stage Topcoat dries quickly to a dust-free
surface with excellent flow and leveling, good hiding and good gloss.

Materials: Supreme Bases: LA & LIB Bases


Supreme Grab & Go Colors: G Bases
Low VOC Acrylic 1K Mixing Clear: LA4899
Reducers: LR10
LR11
LR12
LR13
LR15
LR21
LR25

Substrates prepared
for topcoating: Finish Sanding
Well cured old paint work P500 grit
Primer Surfacer H1000 P320 - P500 grit (dry sand only)
Primer Surfacer LP20 P320 - P500 grit
Primer Surfacer LP610 P320 - P500 grit
Primer Surfacer LP620 P320 - P500 grit
Primer Sealer LP20 Sanding not required
Primer Sealer LP610 Sanding not required
Primer Sealer LP620 Sanding not required

Remarks: Always check local VOC laws to ensure that the use of these Limco products is compliant in your
area.
To retrieve color information from BASF color retrieval software, use paint line SA1V.
For custom Supreme PLUS Low VOC Acrylic 1K Single Stage colors, the color (LA, LIB, G bases) must
be mixed 1 part to 2.5 parts of LA4899 by volume prior to addition of reducer.
OPTIONAL: For a more durable finish, Limco Low VOC Hardener LH601, LH604 or LH606 may be
added at a ratio of 10:1 with 1 part of reducer. Caution: Lighter colors may yellow with the addition
of hardener. Adding hardener will result in a four hour pot life.

US Rev. 11/1/16
T E C H N I C A L D A T A

Supreme PLUS
Low VOC Acrylic 1K Single Stage
340 gms/liter (2.8 lbs/gal) VOC
420 gms/liter (3.5 lbs/gal) VOC
340 gms/liter (2.8 lbs/gal) VOC 420 gms/liter (3.5 lbs/gal) VOC
Mixing ratio: 8:1 8:1
Color 8 parts Color 8 parts Color
Reducer 1 part LR21 or LR25 1 part LR10, LR11, LR12, LR13 or LR15
(may use up to 2 parts of reducer)

Potlife at 68°F/20°C N/A N/A

Spray viscosity Ford #4


S 14 - 18 seconds 14 - 18 seconds
@ 68°F/20°C

Gravity gun nozzle HVLP 1.3 - 1.7 mm 1.3 - 1.7 mm

Spray pressure HVLP at the cap 6 - 10 psi 6 - 10 psi

Application 2 - 3 wet coats 2 - 3 wet coats

Flash-off time @ 68°F/20°C 5 minutes between coats 5 minutes between coats

Film build 2.0 - 3.0 mils 2.0 - 3.0 mils

Coverage 524 - 570 sq. ft./gal @ 1.0 mils 524 - 570 sq. ft./gal @ 1.0 mils

Drying:
68°F/20°C 60 - 90 minutes dust free; 60 - 90 minutes dust free;
3 - 5 hours tack free 3 - 5 hours tack free
140°F/60°C 30 minutes 30 minutes
Infra red short wave N/A N/A
Infra red medium wave N/A N/A

Sanding:
Wet by Hand N/A N/A

Dry by Hand N/A N/A

Dry by Machine N/A N/A

VOC as applied ≤ 340 gms/liter (≤ 2.8 lbs/gal) ≤ 420 gms/liter (≤ 3.5 lbs/gal)

Comments Shake new tinting bases for 15 minutes using a mechanical paint shaker before placing
on a mixing machine.
Tinting bases on a mixing machine need to be agitated for 15 minutes at the start of
the work day and every 4 hours during the day to ensure good color matching.
For areas requiring recoating four or more hours after application:
Scuff with a fine scuff pad (Scotchbrite #7447).
Cleaning: Use an air blow gun to remove all traces of dust and dirt from the cracks and
surfaces of the vehicle.
Clean all areas to be painted with 909 Final Wipe Cleaner.

Materials described are for application by professional trained personnel only using proper equipment. Products may be hazardous & should be used according to label directions & technical data information. Appropriate respiratory protection should be worn at
all times while products are in use—read product label and Material Safety Data Sheet (MSDS) for specific details. Statements & methods described are based upon the latest standard of technology known to the manufacturer. Application procedures cited are
suggestions only & are not to be interpreted as warranty for events resulting from their use. Dilution ratios are intended to provide maximum performance within the typical Volatile Organic Compound (VOC) restriction for product use. Specific VOC limits need to
be referenced to verify local compliance. Altering the solvent or dilution ratio may impact VOC compliance. User is solely responsible to ensure product use and application is in accordance with all applicable regulatory, legislative, and municipal requirements.
Click on logo to return to Table of Contents

T O P C O AT S

Supreme PLUS
Acrylic 2K Single Stage
U.S. National Rule VOC

Description: Limco Supreme PLUS U.S. National Rule Topcoat is a specially formulated Acrylic 2K Single Stage
system designed to meet the rigorous demands of Refinish, Commercial Vehicle, Agricultural and
Fleet markets. Limco Supreme PLUS U.S. National Rule Acrylic 2K Single Stage Topcoat dries quickly
to a dust-free surface with excellent flow and leveling, good hiding and mirror-like gloss. The
Supreme PLUS U.S. National Rule Acrylic 2K Single Stage Topcoat film is also chemically resistant
and has superior hardness.

Materials: Supreme Bases: LA & LIB Bases


Supreme Grab & Go Colors: G Bases
Acrylic 2K Mixing Clear: LA3899
Hardeners: LHF
LHM
LHS
Reducers: LR10
LR11
LR12
LR13
LR15

Substrates prepared
for topcoating: Finish Sanding
Well cured old paint work P500 grit
Primer Surfacer 800K P320 - P500 grit
Primer Surfacer 846 P320 - P500 grit
Primer Surfacer LP20 P320 - P500 grit
Primer Surfacer LP620 P320 - P500 grit
Primer Sealer LP20 Sanding not required
Primer Sealer LP620 Sanding not required
Primer Sealer LS56 Sanding not required
Primer Sealer LS800 Sanding not required
Primer Sealer PS21NR Sanding not required

Remarks: Always check local VOC laws to ensure that the use of these Limco products is compliant in your
area.
To retrieve color information from BASF color retrieval software, use paint line SA2K.
For custom Supreme PLUS Acrylic 2K (600 gms/liter) colors, the color (LA, LIB, G bases) must be
mixed 1 part to 1 part of LA3899 by volume prior to addition of hardener and reducer.

US Rev. 11/1/16
T E C H N I C A L D A T A

Supreme PLUS
Acrylic 2K Single Stage
U.S. National Rule VOC
Mixing ratio: 8:1:1
Color 8 parts Color
Hardener 1 part LHF, LHM or LHS
Reducer 1 part LR10, LR11, LR12, LR13 or LR15

Potlife at 68°F/20°C 2 - 4 hours

Spray viscosity Ford #4


S 14 - 16 seconds
@ 68°F/20°C

Gravity gun nozzle HVLP 1.3 - 1.7 mm

Spray pressure HVLP at the cap 6 - 10 psi

Application 2 - 3 wet coats

Flash-off time @ 68°F/20°C 5 minutes between coats

Film build 2.0 - 3.0 mils

Coverage 634 - 658 sq. ft./gal @ 1.0 mils

Drying:
68°F/20°C 30 - 45 minutes dust free; 4 - 6 hours tack free
140°F/60°C 30 minutes
Infra red short wave N/A
Infra red medium wave N/A

Sanding:
Wet by Hand N/A

Dry by Hand N/A

Dry by Machine N/A

VOC as applied ≤ 600 gms/liter (≤ 5.0 lbs/gal)

Comments Shake new tinting bases for 15 minutes using a mechanical paint shaker before placing
on a mixing machine.
Tinting bases on a mixing machine need to be agitated for 15 minutes at the start of
the work day and every 4 hours during the day to ensure good color matching.

Materials described are for application by professional trained personnel only using proper equipment. Products may be hazardous & should be used according to label directions & technical data information. Appropriate respiratory protection should be worn at
all times while products are in use—read product label and Material Safety Data Sheet (MSDS) for specific details. Statements & methods described are based upon the latest standard of technology known to the manufacturer. Application procedures cited are
suggestions only & are not to be interpreted as warranty for events resulting from their use. Dilution ratios are intended to provide maximum performance within the typical Volatile Organic Compound (VOC) restriction for product use. Specific VOC limits need to
be referenced to verify local compliance. Altering the solvent or dilution ratio may impact VOC compliance. User is solely responsible to ensure product use and application is in accordance with all applicable regulatory, legislative, and municipal requirements.
Click on logo to return to Table of Contents

T O P C O AT S

Supreme PLUS
Low VOC Acrylic 2K Single Stage
340 gms/liter (2.8 lbs/gal) VOC
420 gms/liter (3.5 lbs/gal) VOC

Description: Limco Supreme PLUS Low VOC Topcoat is a specially formulated Acrylic 2K Single Stage system
designed to meet the rigorous demands of Refinish, Commercial Vehicle, Agricultural and Fleet
markets. Limco Supreme PLUS Low VOC Acrylic 2K Single Stage Topcoat dries quickly to a dust-free
surface with excellent flow and leveling, good hiding and mirror-like gloss. The Supreme PLUS Low
VOC Acrylic 2K Single Stage Topcoat film is also chemically resistant and has superior hardness.

Materials: Supreme Bases: LA & LIB Bases


Supreme Grab & Go Colors: G Bases
Acrylic 2K Mixing Clear: LA3899
Hardeners: LH601
LH604
LH606
Reducers: LR10
LR11
LR12
LR13
LR15
LR21
LR25

Substrates prepared
for topcoating: Finish Sanding
Well cured old paint work P500 grit
Primer Surfacer H1000 P320 - P500 grit (dry sand only)
Primer Surfacer LP20 P320 - P500 grit
Primer Surfacer LP610 P320 - P500 grit
Primer Surfacer LP620 P320 - P500 grit
Primer Sealer LP20 Sanding not required
Primer Sealer LP610 Sanding not required
Primer Sealer LP620 Sanding not required

Remarks: Always check local VOC laws to ensure that the use of these Limco products is compliant in your
area.
To retrieve color information from BASF color retrieval software, use paint line SA2V.
For custom Supreme PLUS Low VOC Acrylic 2K Single Stage colors, the color (LA, LIB, G bases) must
be mixed 1 part to 2.5 parts of LA3899 by volume prior to addition of hardener and reducer.

US Rev. 11/1/16
T E C H N I C A L D A T A

Supreme PLUS
Low VOC Acrylic 2K Single Stage
340 gms/liter (2.8 lbs/gal) VOC
420 gms/liter (3.5 lbs/gal) VOC
340 gms/liter (2.8 lbs/gal) VOC 420 gms/liter (3.5 lbs/gal) VOC
Mixing ratio: 8:1:1 8:1:1
Color 8 parts Color 8 parts Color
Hardener 1 part LH601, LH604 or LH606 1 part LH601, LH604 or LH606
Reducer 1 part LR21 or LR25 1 part LR10, LR11, LR12, LR13 or LR15
(may use up to 2 parts of reducer)

Potlife at 68°F/20°C 2 - 3 hours 2 - 3 hours

Spray viscosity Ford #4


S 14 - 18 seconds 14 - 18 seconds
@ 68°F/20°C

Gravity gun nozzle HVLP 1.3 - 1.7 mm 1.3 - 1.7 mm

Spray pressure HVLP at the cap 6 - 10 psi 6 - 10 psi

Application 2 - 3 wet coats 2 - 3 wet coats

Flash-off time @ 68°F/20°C 5 minutes between coats 5 minutes between coats

Film build 2.0 - 3.0 mils 2.0 - 3.0 mils

Coverage 556 - 600 sq. ft./gal @ 1.0 mils 556 - 600 sq. ft./gal @ 1.0 mils

Drying:
68°F/20°C LH601: 25 - 30 minutes dust free; 35 - 45 minutes dust free;
2 hours tack free (depending on reducer) 4 - 6 hours tack free
LH604: 60 - 70 minutes dust free;
4 hours tack free (depending on reducer)
140°F/60°C 30 minutes 30 minutes
Infra red short wave N/A N/A
Infra red medium wave N/A N/A

Sanding:
Wet by Hand N/A N/A

Dry by Hand N/A N/A

Dry by Machine N/A N/A

VOC as applied ≤ 340 gms/liter (≤ 2.8 lbs/gal) ≤ 420 gms/liter (≤ 3.5 lbs/gal)

Comments Shake new tinting bases for 15 minutes using a mechanical paint shaker before placing
on a mixing machine.
Tinting bases on a mixing machine need to be agitated for 15 minutes at the start of
the work day and every 4 hours during the day to ensure good color matching.

Materials described are for application by professional trained personnel only using proper equipment. Products may be hazardous & should be used according to label directions & technical data information. Appropriate respiratory protection should be worn at
all times while products are in use—read product label and Material Safety Data Sheet (MSDS) for specific details. Statements & methods described are based upon the latest standard of technology known to the manufacturer. Application procedures cited are
suggestions only & are not to be interpreted as warranty for events resulting from their use. Dilution ratios are intended to provide maximum performance within the typical Volatile Organic Compound (VOC) restriction for product use. Specific VOC limits need to
be referenced to verify local compliance. Altering the solvent or dilution ratio may impact VOC compliance. User is solely responsible to ensure product use and application is in accordance with all applicable regulatory, legislative, and municipal requirements.
Click on logo to return to Table of Contents

T O P C O AT S

Supreme PLUS
Urethane Single Stage
U.S. National Rule VOC with LA2799

Description: Limco Supreme PLUS U.S. National Rule Topcoat is a specially formulated 2K Urethane Single Stage
system designed to meet the rigorous demands of Refinish, Commercial Vehicle, Agricultural and
Fleet markets. Limco Supreme PLUS U.S. National Rule Urethane Single Stage Topcoat dries quickly
to a dust-free surface with excellent flow and leveling, good hiding and mirror-like gloss. The
Supreme PLUS U.S. National Rule Urethane Single Stage Topcoat film is also chemically resistant
and has superior hardness.

Materials: Supreme Bases: LA & LIB Bases


Supreme Grab & Go Colors: G Bases
Urethane Mixing Clear: LA2799
Hardeners: LHF
LHM
LHS
Reducers: LR10
LR11
LR12
LR13
LR15
Flex Agent: 892

Substrates prepared
for topcoating: Finish Sanding
Well cured old paint work P500 grit
Primer Surfacer 800K P320 - P500 grit
Primer Surfacer 846 P320 - P500 grit
Primer Surfacer LP20 P320 - P500 grit
Primer Surfacer LP620 P320 - P500 grit
Primer Sealer LP20 Sanding not required
Primer Sealer LP620 Sanding not required
Primer Sealer LS56 Sanding not required
Primer Sealer LS800 Sanding not required
Primer Sealer PS21NR Sanding not required

Remarks: Always check local VOC laws to ensure that the use of these Limco products is compliant in your
area.
To retrieve color information from BASF color retrieval software, use paint line SUNR.
For custom Supreme PLUS Urethane Single Stage (U.S. National Rule) colors, the color (LA, LIB,
G bases) must be mixed 2 parts to 1 part of LA2799 by volume prior to addition of hardener and
reducer.

US Rev. 11/1/16
T E C H N I C A L D A T A

Supreme PLUS
Urethane Single Stage
U.S. National Rule VOC with LA2799
Flexed

Mixing ratio: 4:1:2 8:3:2:2

Color 4 parts Color 8 parts Color


Hardener 1 part LHF, LHM or LHS 3 part LHF, LHM or LHS
Flex Agent ­— 2 part 892
Reducer 2 parts LR10, LR11, LR12, LR13 or LR15 2 part LR10, LR11, LR12, LR13 or LR15

Potlife at 68°F/20°C 4 hours 4 hours

Spray viscosity Ford #4


S 16 - 18 seconds 16 - 18 seconds
@ 68°F/20°C

Gravity gun nozzle HVLP 1.3 - 1.5 mm 1.3 - 1.5 mm

Spray pressure HVLP at the cap 6 - 10 psi 6 - 10 psi

Application 2 - 3 wet coats 2 - 3 wet coats

Flash-off time @ 68°F/20°C 5 minutes between coats 5 minutes between coats

Film build 2.0 - 3.0 mils 2.0 - 3.0 mils

Coverage 603 - 626 sq. ft./gal @ 1.0 mils 770 - 791 sq. ft./gal @ 1.0 mils

Drying:
68°F/20°C 3 - 4 hours dust free; 3 - 4 hours dust free;
8 - 10 hours to handle 8 - 10 hours to handle
140°F/60°C 30 minutes 30 minutes
Infra red short wave N/A N/A
Infra red medium wave N/A N/A

Sanding:
Wet by Hand N/A N/A

Dry by Hand N/A N/A

Dry by Machine N/A N/A

VOC as applied ≤ 600 gms/liter (≤ 5.0 lbs/gal) ≤ 600 gms/liter (≤ 5.0 lbs/gal)

Comments Shake new tinting bases for 15 minutes using a mechanical paint shaker before placing
on a mixing machine.
Tinting bases on a mixing machine need to be agitated for 15 minutes at the start of
the work day and every 4 hours during the day to ensure good color matching.
When using LHM in cool temperatures, use up to 1.0 oz of Jet95 Accelerator per ready
for use gallon.

Materials described are for application by professional trained personnel only using proper equipment. Products may be hazardous & should be used according to label directions & technical data information. Appropriate respiratory protection should be worn at
all times while products are in use—read product label and Material Safety Data Sheet (MSDS) for specific details. Statements & methods described are based upon the latest standard of technology known to the manufacturer. Application procedures cited are
suggestions only & are not to be interpreted as warranty for events resulting from their use. Dilution ratios are intended to provide maximum performance within the typical Volatile Organic Compound (VOC) restriction for product use. Specific VOC limits need to
be referenced to verify local compliance. Altering the solvent or dilution ratio may impact VOC compliance. User is solely responsible to ensure product use and application is in accordance with all applicable regulatory, legislative, and municipal requirements.
Click on logo to return to Table of Contents

T O P C O AT S

Supreme PLUS
Urethane Single Stage
U.S. National Rule VOC with LA2999

Description: Limco Supreme PLUS U.S. National Rule Topcoat is a specially formulated 2K Urethane Single Stage
system designed to meet the rigorous demands of Refinish, Commercial Vehicle, Agricultural and
Fleet markets. Limco Supreme PLUS U.S. National Rule Urethane Single Stage Topcoat dries quickly
to a dust-free surface with excellent flow and leveling, good hiding and mirror-like gloss. The
Supreme PLUS U.S. National Rule Urethane Single Stage Topcoat film is also chemically resistant
and has superior hardness.

Materials: Supreme Bases: LA & LIB Bases


Supreme Grab & Go Colors: G Bases
Urethane Single Stage Mixing Clear: LA2999
LA2999S (Slow)
Hardeners: LHF
LHM
LHS
Reducers: LR10
LR11
LR12
LR13
LR15
Flex Agent: 892

Substrates prepared
for topcoating: Finish Sanding
Well cured old paint work P500 grit
Primer Surfacer 800K P320 - P500 grit
Primer Surfacer 846 P320 - P500 grit
Primer Surfacer LP20 P320 - P500 grit
Primer Surfacer LP620 P320 - P500 grit
Primer Sealer LP20 Sanding not required
Primer Sealer LP620 Sanding not required
Primer Sealer LS56 Sanding not required
Primer Sealer LS800 Sanding not required
Primer Sealer PS21NR Sanding not required

Remarks: Always check local VOC laws to ensure that the use of these Limco products is compliant in your
area.
To retrieve color information from BASF color retrieval software, use paint line SUSS.
For custom Supreme PLUS Urethane Single Stage (U.S. National Rule) colors, the color (LA, LIB,
G bases) must be mixed 1 part to 1 part of LA2999 by volume prior to addition of hardener and
reducer.
For larger areas, use LA2999S for slower application properties.

US Rev. 11/1/16
T E C H N I C A L D A T A

Supreme PLUS
Urethane Single Stage
U.S. National Rule VOC with LA2999
Flexed

Mixing ratio: 4:1:2 4:1:1:1

Color 4 parts Color 4 parts Color


Hardener 1 part LHF, LHM or LHS 1 part LHF, LHM or LHS
Flex Agent ­— 1 part 892
Reducer 2 parts LR10, LR11, LR12, LR13 or LR15 1 part LR10, LR11, LR12, LR13 or LR15

1 - 1.5 hours 1 - 1.5 hours


Potlife at 68°F/20°C
3 - 4 hours with LA2999S 3 - 4 hours with LA2999S

Spray viscosity Ford #4


S 16 - 18 seconds 16 - 18 seconds
@ 68°F/20°C

Gravity gun nozzle HVLP 1.3 - 1.5 mm 1.3 - 1.5 mm

Spray pressure HVLP at the cap 6 - 10 psi 6 - 10 psi

Application 2 - 3 wet coats 2 - 3 wet coats

Flash-off time @ 68°F/20°C 5 minutes between coats 5 minutes between coats

Film build 2.0 - 3.0 mils 2.0 - 3.0 mils

Coverage 575 - 625 sq. ft./gal @ 1.0 mils 700 - 750 sq. ft./gal @ 1.0 mils

Drying:
68°F/20°C 1 - 1.5 hours 1 - 1.5 hours
with LA2999S: 3 - 4 hours dust free; with LA2999S: 3 - 4 hours dust free;
8 hours to handle 8 hours to handle
140°F/60°C 30 minutes 30 minutes
Infra red short wave N/A N/A
Infra red medium wave N/A N/A

Sanding:
Wet by Hand N/A N/A

Dry by Hand N/A N/A

Dry by Machine N/A N/A

VOC as applied ≤ 600 gms/liter (≤ 5.0 lbs/gal) ≤ 600 gms/liter (≤ 5.0 lbs/gal)

Comments Shake new tinting bases for 15 minutes using a mechanical paint shaker before placing
on a mixing machine.
Tinting bases on a mixing machine need to be agitated for 15 minutes at the start of
the work day and every 4 hours during the day to ensure good color matching.

Materials described are for application by professional trained personnel only using proper equipment. Products may be hazardous & should be used according to label directions & technical data information. Appropriate respiratory protection should be worn at
all times while products are in use—read product label and Material Safety Data Sheet (MSDS) for specific details. Statements & methods described are based upon the latest standard of technology known to the manufacturer. Application procedures cited are
suggestions only & are not to be interpreted as warranty for events resulting from their use. Dilution ratios are intended to provide maximum performance within the typical Volatile Organic Compound (VOC) restriction for product use. Specific VOC limits need to
be referenced to verify local compliance. Altering the solvent or dilution ratio may impact VOC compliance. User is solely responsible to ensure product use and application is in accordance with all applicable regulatory, legislative, and municipal requirements.
Click on logo to return to Table of Contents

T O P C O AT S

Supreme PLUS
Low VOC Urethane Single Stage
340 gms/liter (2.8 lbs/gal) VOC with LA2799

Description: Limco Supreme PLUS Topcoat 340 gms/liter (2.8 lbs/gal) VOC is a specially formulated 2K Urethane
Single Stage system designed to meet the rigorous demands of Refinish, Commercial Vehicle,
Agricultural and Fleet markets. Limco Supreme PLUS Urethane Single Stage Topcoat 340 gms/liter
(2.8 lbs/gal) VOC dries quickly to a dust-free surface with excellent flow and leveling, good hiding
and mirror-like gloss. The Supreme PLUS Urethane Single Stage Topcoat 340 gms/liter (2.8 lbs/gal)
VOC film is also chemically resistant and has superior hardness.

Materials: Supreme Bases: LA & LIB Bases


Supreme Grab & Go Colors: G Bases
Urethane Mixing Clear: LA2799
Hardeners: LH601
LH604
LH606
Reducers: LR21
LR25
Flex Agent: 892

Substrates prepared
for topcoating: Finish Sanding
Well cured old paint work P500 grit
Primer Surfacer H1000 P320 - P500 grit (dry sand only)
Primer Surfacer LP20 P320 - P500 grit
Primer Surfacer LP610 P320 - P500 grit
Primer Surfacer LP620 P320 - P500 grit
Primer Sealer LP20 Sanding not required
Primer Sealer LP610 Sanding not required
Primer Sealer LP620 Sanding not required

Remarks: Always check local VOC laws to ensure that the use of these Limco products is compliant in your
area.
To retrieve color information from BASF color retrieval software, use paint line SU28.
For custom Supreme PLUS Low VOC Urethane Single Stage (340 gms/liter) colors, the color (LA,
LIB, G bases) must be mixed 1 part to 1 part of LA2799 by volume prior to addition of hardener
and reducer.

US Rev. 11/1/16
T E C H N I C A L D A T A

Supreme PLUS
Low VOC Urethane Single Stage
340 gms/liter (2.8 lbs/gal) VOC with LA2799
Flexed
Mixing ratio: 4:1:2 8:3:2:2
Color 4 parts Color 8 parts Color
Hardener 1 part LH601, LH604 or LH606 3 parts LH601, LH604 or LH606
Flex Agent — 2 parts 892
Reducer 2 parts LR21 or LR25 2 parts LR21 or LR25

Potlife at 68°F/20°C 4 hours 4 hours

Spray viscosity Ford #4


S 16 - 18 seconds 16 - 18 seconds
@ 68°F/20°C

Gravity gun nozzle HVLP 1.3 - 1.5 mm 1.3 - 1.5 mm

Spray pressure HVLP at the cap 6 - 10 psi 6 - 10 psi

Application 2 - 3 wet coats 2 - 3 wet coats

Flash-off time @ 68°F/20°C 5 minutes between coats 5 minutes between coats

Film build 2.0 - 3.0 mils 2.0 - 3.0 mils

Coverage 661 - 678 sq. ft./gal @ 1.0 mils 832 - 848 sq. ft./gal @ 1.0 mils

Drying:
68°F/20°C 3 - 4 hours dust free; 3 - 4 hours dust free;
8 - 10 hours to handle 8 - 10 hours to handle
140°F/60°C 30 minutes 30 minutes
Infra red short wave N/A N/A
Infra red medium wave N/A N/A

Sanding:
Wet by Hand N/A N/A

Dry by Hand N/A N/A

Dry by Machine N/A N/A

VOC as applied ≤ 340 gms/liter (≤ 2.8 lbs/gal) ≤ 340 gms/liter (≤ 2.8 lbs/gal)

Comments Shake new tinting bases for 15 minutes using a mechanical paint shaker before placing
on a mixing machine.
Tinting bases on a mixing machine need to be agitated for 15 minutes at the start of
the work day and every 4 hours during the day to ensure good color matching.

Materials described are for application by professional trained personnel only using proper equipment. Products may be hazardous & should be used according to label directions & technical data information. Appropriate respiratory protection should be worn at
all times while products are in use—read product label and Material Safety Data Sheet (MSDS) for specific details. Statements & methods described are based upon the latest standard of technology known to the manufacturer. Application procedures cited are
suggestions only & are not to be interpreted as warranty for events resulting from their use. Dilution ratios are intended to provide maximum performance within the typical Volatile Organic Compound (VOC) restriction for product use. Specific VOC limits need to
be referenced to verify local compliance. Altering the solvent or dilution ratio may impact VOC compliance. User is solely responsible to ensure product use and application is in accordance with all applicable regulatory, legislative, and municipal requirements.
Click on logo to return to Table of Contents

T O P C O AT S

Supreme PLUS
Low VOC Urethane Single Stage
420 gms/liter (3.5 lbs/gal) VOC with LA2799

Description: Limco Supreme PLUS Topcoat 420 gms/liter (3.5 lbs/gal) VOC is a specially formulated 2K Urethane
Single Stage system designed to meet the rigorous demands of Refinish, Commercial Vehicle,
Agricultural and Fleet markets. Limco Supreme PLUS Urethane Single Stage Topcoat 420 gms/liter
(3.5 lbs/gal) VOC dries quickly to a dust-free surface with excellent flow and leveling, good hiding
and mirror-like gloss. The Supreme PLUS Urethane Single Stage Topcoat 420 gms/liter (3.5 lbs/gal)
VOC film is also chemically resistant and has superior hardness.

Materials: Supreme Bases: LA & LIB Bases


Supreme Grab & Go Colors: G Bases
Urethane Mixing Clear: LA2799
Hardeners: LH601
LH604
LH606
Reducers: LR21
LR25
Flex Agent: 892

Substrates prepared
for topcoating: Finish Sanding
Well cured old paint work P500 grit
Primer Surfacer H1000 P320 - P500 grit (dry sand only)
Primer Surfacer LP20 P320 - P500 grit
Primer Surfacer LP610 P320 - P500 grit
Primer Surfacer LP620 P320 - P500 grit
Primer Sealer LP20 Sanding not required
Primer Sealer LP610 Sanding not required
Primer Sealer LP620 Sanding not required

Remarks: Always check local VOC laws to ensure that the use of these Limco products is compliant in your
area.
To retrieve color information from BASF color retrieval software, use paint line SU35.
For custom Supreme PLUS Low VOC Urethane Single Stage (420 gms/liter) colors, the color
(LA, LIB, G bases) must be mixed 2 parts to 1 part of LA2799 by volume prior to addition of hardener
and reducer.

US Rev. 11/1/16
T E C H N I C A L D A T A

Supreme PLUS
Low VOC Urethane Single Stage
420 gms/liter (3.5 lbs/gal) VOC with LA2799
Flexed
Mixing ratio: 4:1:2 8:3:2:2
Color 4 parts Color 8 parts Color
Hardener 1 part LH601, LH604 or LH606 3 parts LH601, LH604 or LH606
Flex Agent — 2 parts 892
Reducer 2 parts LR21 or LR25 2 parts LR21 or LR25

Potlife at 68°F/20°C 1 - 1.5 hours 1 - 1.5 hours

Spray viscosity Ford #4


S 16 - 18 seconds 16 - 18 seconds
@ 68°F/20°C

Gravity gun nozzle HVLP 1.3 - 1.5 mm 1.3 - 1.5 mm

Spray pressure HVLP at the cap 6 - 10 psi 6 - 10 psi

Application 2 - 3 wet coats 2 - 3 wet coats

Flash-off time @ 68°F/20°C 5 minutes between coats 5 minutes between coats

Film build 2.0 - 3.0 mils 2.0 - 3.0 mils

Coverage 620 - 643 sq. ft./gal @ 1.0 mils 794 - 815 sq. ft./gal @ 1.0 mils

Drying:
68°F/20°C 3 - 4 hours dust free; 3 - 4 hours dust free;
8 - 10 hours to handle 8 - 10 hours to handle
140°F/60°C 30 minutes 30 minutes
Infra red short wave N/A N/A
Infra red medium wave N/A N/A

Sanding:
Wet by Hand N/A N/A

Dry by Hand N/A N/A

Dry by Machine N/A N/A

VOC as applied ≤ 420 gms/liter (≤ 3.5 lbs/gal) ≤ 420 gms/liter (≤ 3.5 lbs/gal)

Comments Shake new tinting bases for 15 minutes using a mechanical paint shaker before placing
on a mixing machine.
Tinting bases on a mixing machine need to be agitated for 15 minutes at the start of
the work day and every 4 hours during the day to ensure good color matching.

Materials described are for application by professional trained personnel only using proper equipment. Products may be hazardous & should be used according to label directions & technical data information. Appropriate respiratory protection should be worn at
all times while products are in use—read product label and Material Safety Data Sheet (MSDS) for specific details. Statements & methods described are based upon the latest standard of technology known to the manufacturer. Application procedures cited are
suggestions only & are not to be interpreted as warranty for events resulting from their use. Dilution ratios are intended to provide maximum performance within the typical Volatile Organic Compound (VOC) restriction for product use. Specific VOC limits need to
be referenced to verify local compliance. Altering the solvent or dilution ratio may impact VOC compliance. User is solely responsible to ensure product use and application is in accordance with all applicable regulatory, legislative, and municipal requirements.
Click on logo to return to Table of Contents

T O P C O AT S

Supreme PLUS
Low VOC Urethane Single Stage
340 gms/liter (2.8 lbs/gal) VOC with LA2899
420 gms/liter (3.5 lbs/gal) VOC with LA2899

Description: Limco Supreme PLUS Low VOC Topcoat is a specially formulated 2K Urethane Single Stage system
designed to meet the rigorous demands of Refinish, Commercial Vehicle, Agricultural and Fleet
markets. Limco Supreme PLUS Low VOC Urethane Single Stage Topcoat dries quickly to a dust-free
surface with excellent flow and leveling, good hiding and mirror-like gloss. The Supreme PLUS Low
VOC Urethane Single Stage Topcoat film is also chemically resistant and has superior hardness.

Materials: Supreme Bases: LA & LIB Bases


Supreme Grab & Go Colors: G Bases
Low VOC Urethane Single Stage
Mixing Clear: LA2899
Hardeners: LH601
LH604
LH606
Reducers: LR10
LR11
LR12
LR13
LR15
LR21
LR25
Flex Agent: 892

Substrates prepared
for topcoating: Finish Sanding
Well cured old paint work P500 grit
Primer Surfacer H1000 P320 - P500 grit (dry sand only)
Primer Surfacer LP20 P320 - P500 grit
Primer Surfacer LP610 P320 - P500 grit
Primer Surfacer LP620 P320 - P500 grit
Primer Sealer LP20 Sanding not required
Primer Sealer LP610 Sanding not required
Primer Sealer LP620 Sanding not required

Remarks: Always check local VOC laws to ensure that the use of these Limco products is compliant in your
area.
To retrieve color information from BASF color retrieval software, use paint line SUSV.
For custom Supreme PLUS Low VOC Urethane Single Stage colors, the color (LA, LIB, G bases) must
be mixed 1 part to 2 parts of LA2899 by volume prior to addition of hardener and reducer.

US Rev. 11/1/16
T E C H N I C A L D A T A

Supreme PLUS
Low VOC Urethane Single Stage
340 gms/liter (2.8 lbs/gal) VOC with LA2899
420 gms/liter (3.5 lbs/gal) VOC with LA2899
340 gms/liter VOC 420 gms/liter VOC
Flexed for either Low VOC
(2.8 lbs/gal) (3.5 lbs/gal)
Mixing ratio: 8:2:2 8:2:1 8:3:2:2
Color 8 parts Color 8 parts Color 8 parts Color
Hardener 2 parts LH601, LH604 or 2 parts LH601, LH604 or 3 parts LH601, LH604 or
LH606 LH606 LH606
Flex Agent — — 2 parts 892
Reducer 2 parts LR21 or LR25 1 part LR10, LR11, LR12, 340 gms/liter VOC:
LR13 or LR15 2 parts LR21 or LR25
or
420 gms/liter VOC:
2 parts LR10, LR11, LR12,
LR13 or LR15

Potlife at 68°F/20°C 1 - 1.5 hours 1 - 1.5 hours 1 - 1.5 hours

Spray viscosity Ford #4


S 16 - 18 seconds 16 - 18 seconds 16 - 18 seconds
@ 68°F/20°C

Gravity gun nozzle HVLP 1.3 - 1.5 mm 1.3 - 1.5 mm 1.3 - 1.5 mm

Spray pressure HVLP at the cap 6 - 10 psi 6 - 10 psi 6 - 10 psi

Application 2 - 3 wet coats 2 - 3 wet coats 2 - 3 wet coats

Flash-off time @ 68°F/20°C 5 minutes between coats 5 minutes between coats 5 minutes between coats

Film build 2.0 - 3.0 mils 2.0 - 3.0 mils 2.0 - 3.0 mils

600 - 650 sq. ft./gal 600 - 650 sq. ft./gal 690 - 730 sq. ft./gal
Coverage
@ 1.0 mils @ 1.0 mils @ 1.0 mils

Drying:
68°F/20°C 1 hour 1 hour 1 hour
140°F/60°C 30 minutes 30 minutes 30 minutes
Infra red short wave N/A N/A N/A
Infra red medium wave N/A N/A N/A

Sanding:
Wet by Hand N/A N/A N/A

Dry by Hand N/A N/A N/A

Dry by Machine N/A N/A N/A

≤ 340 gms/liter
(≤ 2.8 lbs/gal)
≤ 340 gms/liter ≤ 420 gms/liter
VOC as applied or
(≤ 2.8 lbs/gal) (≤ 3.5 lbs/gal)
≤ 420 gms/liter
(≤ 3.5 lbs/gal)

Comments Shake new tinting bases for 15 minutes using a mechanical paint shaker before placing
on a mixing machine.
Tinting bases on a mixing machine need to be agitated for 15 minutes at the start of
the work day and every 4 hours during the day to ensure good color matching.

Materials described are for application by professional trained personnel only using proper equipment. Products may be hazardous & should be used according to label directions & technical data information. Appropriate respiratory protection should be worn at
all times while products are in use—read product label and Material Safety Data Sheet (MSDS) for specific details. Statements & methods described are based upon the latest standard of technology known to the manufacturer. Application procedures cited are
suggestions only & are not to be interpreted as warranty for events resulting from their use. Dilution ratios are intended to provide maximum performance within the typical Volatile Organic Compound (VOC) restriction for product use. Specific VOC limits need to
be referenced to verify local compliance. Altering the solvent or dilution ratio may impact VOC compliance. User is solely responsible to ensure product use and application is in accordance with all applicable regulatory, legislative, and municipal requirements.
Click on logo to return to Table of Contents

T O P C O AT S

Supreme PLUS
Basecoat
U.S. National Rule VOC

Description: Limco Supreme PLUS U.S. National Rule Basecoat is a Basecoat/Clearcoat system that features high
strength, fast hiding basecoat colors and a very durable clearcoat. This system can be used for the
repair of original basecoat/clearcoat finishes or for a complete paint job.

Materials: Supreme Bases: LA & LIB Bases


Supreme Grab & Go Colors: G Bases
Basecoat Mixing Clear: LA1399
Reducers: LR10
LR11
LR12
LR13
LR15

Substrates prepared
for topcoating: Finish Sanding
Well cured old paint work P500 grit
Primer Surfacer 800K P320 - P500 grit
Primer Surfacer 846 P320 - P500 grit
Primer Surfacer LP20 P320 - P500 grit
Primer Surfacer LP620 P320 - P500 grit
Primer Sealer LP20 Sanding not required
Primer Sealer LP620 Sanding not required
Primer Sealer LS56 Sanding not required
Primer Sealer LS800 Sanding not required
Primer Sealer PS21NR Sanding not required

Clearcoats: LC4000 (High Solids version only)


LC4100
LC4500

Remarks: Always check local VOC laws to ensure that the use of these Limco products is compliant in your
area.
To retrieve color information from BASF color retrieval software, use paint line SPBT.
For custom Supreme PLUS Basecoat (U.S. National Rule) colors, the color (LA, LIB, G bases) must be
mixed 2 parts to 1 part of LA1399 by volume prior to addition of reducer.

US Rev. 11/1/16
T E C H N I C A L D A T A

Supreme PLUS
Basecoat
U.S. National Rule VOC
Mixing ratio: 2:1
Color 2 parts Color
Reducer 1 part LR10, LR11, LR12, LR13 or LR15

Potlife at 68°F/20°C N/A

Spray viscosity Ford #4


S 14 - 16 seconds
@ 68°F/20°C

Gravity gun nozzle HVLP 1.3 - 1.5 mm

Spray pressure HVLP at the cap 6 - 10 psi

Application 2 - 3 wet coats

Flash-off time @ 68°F/20°C 5 - 10 minutes between coats

Film build 0.5 - 1.5 mils

Coverage 275 - 410 sq. ft./gal @ 1.0 mils

Drying:
68°F/20°C 15 - 30 minutes before clearcoating
140°F/60°C 10 minutes
Infra red short wave N/A
Infra red medium wave N/A

Sanding:
Wet by Hand N/A

Dry by Hand N/A

Dry by Machine N/A

VOC as applied ≤ 680 gms/liter (≤ 5.7 lbs/gal)

Comments Shake new tinting bases for 15 minutes using a mechanical paint shaker before placing
on a mixing machine.
Tinting bases on a mixing machine need to be agitated for 15 minutes at the start of
the work day and every 4 hours during the day to ensure good color matching.

Materials described are for application by professional trained personnel only using proper equipment. Products may be hazardous & should be used according to label directions & technical data information. Appropriate respiratory protection should be worn at
all times while products are in use—read product label and Material Safety Data Sheet (MSDS) for specific details. Statements & methods described are based upon the latest standard of technology known to the manufacturer. Application procedures cited are
suggestions only & are not to be interpreted as warranty for events resulting from their use. Dilution ratios are intended to provide maximum performance within the typical Volatile Organic Compound (VOC) restriction for product use. Specific VOC limits need to
be referenced to verify local compliance. Altering the solvent or dilution ratio may impact VOC compliance. User is solely responsible to ensure product use and application is in accordance with all applicable regulatory, legislative, and municipal requirements.
Click on logo to return to Table of Contents

T O P C O AT S

Supreme PLUS
Low VOC Basecoat
420 gms/liter (3.5 lbs/gal) VOC

Description: Limco Supreme PLUS Low VOC Basecoat is a Basecoat/Clearcoat system that features high strength,
fast hiding basecoat colors and a very durable clearcoat. This system can be used for the repair of
original basecoat/clearcoat finishes or for a complete paint job.

Materials: Supreme Bases: LA & LIB Bases


Supreme Grab & Go Colors: G Bases
Low VOC
Basecoat Mixing Clear: LA1299
Hardeners: LH601
LH604
LH606
Reducers: LR21
LR25

Substrates prepared
for topcoating: Finish Sanding
Well cured old paint work P500 grit
Primer Surfacer H1000 P320 - P500 grit (dry sand only)
Primer Surfacer LP20 P320 - P500 grit
Primer Surfacer LP610 P320 - P500 grit
Primer Surfacer LP620 P320 - P500 grit
Primer Sealer LP20 Sanding not required
Primer Sealer LP610 Sanding not required
Primer Sealer LP620 Sanding not required

Clearcoats: LC4200
LC4800

Remarks: Always check local VOC laws to ensure that the use of these Limco products is compliant in your
area.
To retrieve color information from BASF color retrieval software, use paint line SPBV.
For custom Supreme PLUS Low VOC Basecoat (420 gms/liter) colors, the color (LA, LIB, G bases)
must be mixed 1 part to 2 parts of LA1299 by volume prior to addition of hardener and reducer.

US Rev. 11/1/16
T E C H N I C A L D A T A

Supreme PLUS
Low VOC Basecoat
420 gms/liter (3.5 lbs/gal) VOC
Mixing ratio: 3:1 + 3%
Color 3 parts Color
Reducer 1 - 2 parts LR21 or LR25
Hardener 3% LH601, LH604 or LH606

Potlife at 68°F/20°C N/A

Spray viscosity Ford #4


S 14 - 16 seconds
@ 68°F/20°C

Gravity gun nozzle HVLP 1.3 - 1.5 mm

Spray pressure HVLP at the cap 6 - 10 psi

Application 2 - 3 wet coats

Flash-off time @ 68°F/20°C 5 - 10 minutes between coats

Film build 0.8 - 1.5 mils

Coverage 275 - 430 sq. ft./gal @ 1.0 mils

Drying:
68°F/20°C 15 - 30 minutes before clearcoating
140°F/60°C 10 minutes
Infra red short wave N/A
Infra red medium wave N/A

Sanding:
Wet by Hand N/A

Dry by Hand N/A

Dry by Machine N/A

VOC as applied ≤ 420 gms/liter (≤ 3.5 lbs/gal)

Comments Shake new tinting bases for 15 minutes using a mechanical paint shaker before placing
on a mixing machine.
Tinting bases on a mixing machine need to be agitated for 15 minutes at the start of
the work day and every 4 hours during the day to ensure good color matching.

Materials described are for application by professional trained personnel only using proper equipment. Products may be hazardous & should be used according to label directions & technical data information. Appropriate respiratory protection should be worn at
all times while products are in use—read product label and Material Safety Data Sheet (MSDS) for specific details. Statements & methods described are based upon the latest standard of technology known to the manufacturer. Application procedures cited are
suggestions only & are not to be interpreted as warranty for events resulting from their use. Dilution ratios are intended to provide maximum performance within the typical Volatile Organic Compound (VOC) restriction for product use. Specific VOC limits need to
be referenced to verify local compliance. Altering the solvent or dilution ratio may impact VOC compliance. User is solely responsible to ensure product use and application is in accordance with all applicable regulatory, legislative, and municipal requirements.
Click on logo to return to Table of Contents

T O P C O AT S

Supreme PLUS
2K Direct-to-metal
U.S. National Rule VOC

Description: Limco Supreme PLUS U.S. National Rule 2K Direct-to-metal Topcoat is a two component, high build,
acrylic urethane for topcoating properly prepared bare steel, aluminum and galvanized substrates.
Limco Supreme PLUS 2K Direct-to-metal topcoat is a very glossy, durable and chemically resistant
topcoat finish. It has excellent flow, leveling properties and good sag resistance.

Materials: Supreme Bases: LA & LIB Bases


Supreme Grab & Go Colors: G Bases
DTM Mixing Clear: LA5999
Hardener: LH710
Reducers: LR10
LR11
LR12
LR13
LR15

Substrates prepared
for topcoating: Cleaning Finish Sanding Second Cleaning
Steel 203 Wax and Grease Remover P80 - P180 grit 139 Final Wash Cleaner
Aluminum 203 Wax and Grease Remover P120 - P180 grit 139 Final Wash Cleaner
Zinc or Galvanized 203 Wax and Grease Remover Coarse scuff pad 139 Final Wash Cleaner

NOTES: Make sure sanding is not so vigorous that it removes the galvanized or zinc coating.
With the second cleaning, make sure all residue is removed.

Remarks: Always check local VOC laws to ensure that the use of these Limco products is compliant in your
area.
To retrieve color information from BASF color retrieval software, use paint line SDTM.
Surface cleaning and preparation is critical for Limco Supreme PLUS 2K Direct-to-metal Topcoat's
success. All grease, dirt and rust must be removed from substrate.
Agitate thoroughly on a mixing machine before each use.
For custom Supreme PLUS 2K Direct-to-metal (U.S. National Rule) colors, the color (LA, LIB, G bases)
must be mixed 1 part to 2 parts of LA5999 by volume prior to addition of hardener and reducer.

US. Rev. 11/1/16


T E C H N I C A L D A T A

Supreme PLUS
2K Direct-to-metal
U.S. National Rule VOC
Mixing ratio: 4:1:1
Color 4 parts Color
Hardener 1 part LH710
Reducer 1 part LR10, LR11, LR12, LR13 or LR15

Potlife at 68°F/20°C 4 hours

Spray viscosity Ford #4


S 14 - 18 seconds
@ 68°F/20°C

Gravity gun nozzle HVLP 1.3 - 1.7 mm

Spray pressure HVLP at the cap 6 - 10 psi

Application 2 - 3 wet coats

Flash-off time @ 68°F/20°C 5 minutes between coats

Film build 2.0 - 3.0 mils

Coverage 500 - 590 sq. ft./gal @ 1.0 mils

Drying:
68°F/20°C 25 - 30 minutes dust free; 2 hours tack free (depending on reducer)
140°F/60°C 30 minutes
Infra red short wave N/A
Infra red medium wave N/A

Sanding:
Wet by Hand N/A

Dry by Hand N/A

Dry by Machine N/A

VOC as applied ≤ 600 gms/liter (≤ 5.0 lbs/gal)

Comments Shake new tinting bases for 15 minutes using a mechanical paint shaker before placing
on a mixing machine.
Tinting bases on a mixing machine need to be agitated for 15 minutes at the start of
the work day and every 4 hours during the day to ensure good color matching.

Materials described are for application by professional trained personnel only using proper equipment. Products may be hazardous & should be used according to label directions & technical data information. Appropriate respiratory protection should be worn at
all times while products are in use—read product label and Material Safety Data Sheet (MSDS) for specific details. Statements & methods described are based upon the latest standard of technology known to the manufacturer. Application procedures cited are
suggestions only & are not to be interpreted as warranty for events resulting from their use. Dilution ratios are intended to provide maximum performance within the typical Volatile Organic Compound (VOC) restriction for product use. Specific VOC limits need to
be referenced to verify local compliance. Altering the solvent or dilution ratio may impact VOC compliance. User is solely responsible to ensure product use and application is in accordance with all applicable regulatory, legislative, and municipal requirements.
Click on logo to return to Table of Contents

T O P C O AT S

Supreme PLUS
2K Direct-to-metal
420 gms/liter (3.5 lbs/gal) VOC

Description: Limco Supreme PLUS 2K Direct-to-metal Topcoat 420 gms/liter (3.5 lbs/gal) VOC is a two component,
high build, acrylic urethane for topcoating properly prepared bare steel, aluminum and galvanized
substrates. Limco Supreme PLUS 2K Direct-to-metal Topcoat 420 gms/liter (3.5 lbs/gal) VOC is a very
glossy, durable and chemically resistant topcoat finish. It has excellent flow, leveling properties
and good sag resistance.

Materials: Supreme Bases: LA & LIB Bases


Supreme Grab & Go Colors: G Bases
DTM Mixing Clear: LA5999
Hardener: LH710
Reducers: LR21
LR25

Substrates prepared
for topcoating: Cleaning Finish Sanding Second Cleaning
Steel R-M 909 Final Wipe P80 - P180 grit R-M 909 Final Wipe
Aluminum R-M 909 Final Wipe P120 - P180 grit R-M 909 Final Wipe
Zinc or Galvanized R-M 909 Final Wipe Coarse scuff pad R-M 909 Final Wipe

NOTES: Make sure sanding is not so vigorous that it removes the galvanized or zinc coating.
With the second cleaning, make sure all residue is removed.

Remarks: Always check local VOC laws to ensure that the use of these Limco products is compliant in your
area.
To retrieve color information from BASF color retrieval software, use paint line SDTV.
Surface cleaning and preparation is critical for Limco Supreme PLUS 2K Direct-to-metal Topcoat's
success. All grease, dirt and rust must be removed from substrate.
Agitate thoroughly on a mixing machine before each use.
For custom Supreme PLUS 2K Direct-to-metal (420 gms/liter) colors, the color (LA, LIB, G bases)
must be mixed 1 part to 2 parts of LA5999 by volume prior to addition of hardener and reducer.

US. Rev. 11/1/16


T E C H N I C A L D A T A

Supreme PLUS
2K Direct-to-metal
420 gms/liter (3.5 lbs/gal) VOC
Mixing ratio: 4:1:1
Color 4 parts Color
Hardener 1 part LH710
Reducer 1 part LR21 or LR25

Potlife at 68°F/20°C 4 hours

Spray viscosity Ford #4


S 14 - 18 seconds
@ 68°F/20°C

Gravity gun nozzle HVLP 1.3 - 1.7 mm

Spray pressure HVLP at the cap 6 - 10 psi

Application 2 - 3 wet coats

Flash-off time @ 68°F/20°C 5 minutes between coats

Film build 2.0 - 3.0 mils

Coverage 500 - 590 sq. ft./gal @ 1.0 mils

Drying:
68°F/20°C 25 - 30 minutes dust free; 2 hours tack free (depending on reducer)
140°F/60°C 30 minutes
Infra red short wave N/A
Infra red medium wave N/A

Sanding:
Wet by Hand N/A

Dry by Hand N/A

Dry by Machine N/A

VOC as applied ≤ 420 gms/liter (≤ 3.5 lbs/gal)

Comments Shake new tinting bases for 15 minutes using a mechanical paint shaker before placing
on a mixing machine.
Tinting bases on a mixing machine need to be agitated for 15 minutes at the start of
the work day and every 4 hours during the day to ensure good color matching.

Materials described are for application by professional trained personnel only using proper equipment. Products may be hazardous & should be used according to label directions & technical data information. Appropriate respiratory protection should be worn at
all times while products are in use—read product label and Material Safety Data Sheet (MSDS) for specific details. Statements & methods described are based upon the latest standard of technology known to the manufacturer. Application procedures cited are
suggestions only & are not to be interpreted as warranty for events resulting from their use. Dilution ratios are intended to provide maximum performance within the typical Volatile Organic Compound (VOC) restriction for product use. Specific VOC limits need to
be referenced to verify local compliance. Altering the solvent or dilution ratio may impact VOC compliance. User is solely responsible to ensure product use and application is in accordance with all applicable regulatory, legislative, and municipal requirements.
Click on logo to return to Table of Contents

C L E A R C O AT S

LC4000 Clearcoat (High Solids Version)


U.S. National Rule VOC

Description: Limco LC4000 Clearcoat (High Solids version) is an acrylic urethane clear for use over Limco Supreme
PLUS Basecoat colors. It is designed to increase the profitability and productivity of the repair
facility. It is U.S. National Rule compliant, easy to apply and has excellent gloss and leveling.

Materials: Clearcoat: LC4000


Hardeners: LHF
LHM
LHS
Flex Agent: 892

Basecoats: Supreme PLUS Basecoat

Remarks: Always check local VOC laws to ensure that the use of these Limco products is compliant in your
area.
ONLY the "High Solids Version" of LC4000 may be used. Indicated on product labels with a
"starburst".
LC4000 is not covered by a warranty and should not be used with warrantable systems.

US Rev. 11/1/16
T E C H N I C A L D A T A

LC4000 Clearcoat (High Solids Version)


U.S. National Rule VOC
Flexed
Mixing ratio: 4:1 4:2:1
Clear 4 parts LC4000 4 parts LC4000
Hardener 1 part LHF, LHM or LHS 2 parts LHF, LHM or LHS
Flex Agent — 1 part 892

Potlife at 68°F/20°C 6 hours 4 hours

Spray viscosity Ford #4


S 14 - 16 seconds 15 - 17 seconds
@ 68°F/20°C

Gravity gun nozzle HVLP 1.1 - 1.3 mm 1.1 - 1.3 mm

Spray pressure HVLP at the cap 9 - 10 psi 9 - 10 psi

Application 2 - 3 coats 2 - 3 coats

Flash-off time @ 68°F/20°C 5 minutes between coats 5 minutes between coats

Film build 2.0 - 2.4 mils 2.0 - 2.4 mils

Coverage 601 sq. ft./gal @ 1.0 mils 729 sq. ft./gal @ 1.0 mils

Drying:
68°F/20°C 30 minutes dust free; 30 minutes dust free;
8 hours to handle 8 hours to handle
140°F/60°C 30 minutes; must allow 5 minutes 30 minutes; must allow 5 minutes
flash before force dry flash before force dry
Infra red short wave 6 - 8 minutes 6 - 8 minutes
Infra red medium wave N/A N/A

Sanding:
Wet by Hand 1200 or Finer 1200 or Finer

Dry by Hand P1200 or Finer P1200 or Finer

Dry by Machine P1200 or Finer P1200 or Finer

VOC as applied 550 gms/liter (4.6 lbs/gal) 460 gms/liter (4.0 lbs/gal)

Comments Wait 24 hours before sanding, compounding or recoating.

Materials described are for application by professional trained personnel only using proper equipment. Products may be hazardous & should be used according to label directions & technical data information. Appropriate respiratory protection should be worn at
all times while products are in use—read product label and Material Safety Data Sheet (MSDS) for specific details. Statements & methods described are based upon the latest standard of technology known to the manufacturer. Application procedures cited are
suggestions only & are not to be interpreted as warranty for events resulting from their use. Dilution ratios are intended to provide maximum performance within the typical Volatile Organic Compound (VOC) restriction for product use. Specific VOC limits need to
be referenced to verify local compliance. Altering the solvent or dilution ratio may impact VOC compliance. User is solely responsible to ensure product use and application is in accordance with all applicable regulatory, legislative, and municipal requirements.
Click on logo to return to Table of Contents

C L E A R C O AT S

LC4100 High Solids Clearcoat


U.S. National Rule VOC

Description: Limco LC4100 High Solids Clearcoat is a U.S. National Rule Compliant acrylic urethane clear for use
over Limco Supreme PLUS Basecoat colors. It is designed to increase the profitability and productivity
of the repair facility. LC4100 is an easy to apply two coat clear that has excellent gloss and leveling.
LC4100 offers a range of reducers to meet your temperature needs.

Materials: Clearcoat: LC4100


Hardeners: LHF
LHM
LHS
Reducers: LR10
LR11
LR12
LR13
LR15
LR21
LR25
Flex Agent: 892

Basecoats: Supreme PLUS Basecoat

Remarks: Always check local VOC laws to ensure that the use of these Limco products is compliant in your
area.
LC4100 is not covered by a warranty and should not be used with warrantable systems.

US Rev. 11/1/16
T E C H N I C A L D A T A

LC4100 High Solids Clearcoat


U.S. National Rule VOC
Flexed *

Mixing ratio: 8:2:1 4:1:1 4:2:1:1


Clear 8 parts LC4100 4 parts LC4100 4 parts LC4100
Hardener 2 part LHF, LHM or LHS 1 part LHF, LHM or LHS 2 parts LHF, LHM or LHS
Reducer 1 part LR10, LR11, LR12, 1 part LR21 or LR25 1 part LR10, LR11, LR12,
LR13 or LR15 LR13 or LR15
Flex Agent — — 1 part 892

Potlife at 68°F/20°C 4 hours 5 hours 3 hours

Spray viscosity Ford #4


S 14 - 16 seconds 14 - 16 seconds 15 - 17 seconds
@ 68°F/20°C

Gravity gun nozzle HVLP 1.1 - 1.3 mm 1.1 - 1.3 mm 1.1 - 1.3 mm

Spray pressure HVLP at the cap 9 - 10 psi 9 - 10 psi 9 - 10 psi

Application 2 coats 2 coats 2 coats

5 - 10 minutes 5 - 10 minutes 5 - 10 minutes


Flash-off time @ 68°F/20°C
between coats between coats between coats

Film build 2.0 - 3.0 mils 2.0 - 2.4 mils 2.0 - 3.0 mils

Coverage 617 sq. ft./gal @ 1.0 mils 574 sq. ft./gal @ 1.0 mils 693 sq. ft./gal @ 1.0 mils

Drying:
68°F/20°C 30 minutes dust free; 30 minutes dust free; 45 minutes dust free;
8 hours to handle 8 hours to handle 8 hours to handle
140°F/60°C 30 minutes; must allow 30 minutes; must allow 30 minutes; must allow
5 minutes flash before 5 minutes flash before 5 minutes flash before
force dry force dry force dry
Infra red short wave 6 - 10 minutes 6 - 10 minutes 6 - 10 minutes
Infra red medium wave N/A N/A N/A

Sanding:
Wet by Hand 1200 or Finer 1200 or Finer 1200 or Finer

Dry by Hand P1200 or Finer P1200 or Finer P1200 or Finer

Dry by Machine P1200 or Finer P1200 or Finer P1200 or Finer

VOC as applied 538 gms/liter (4.5 lbs/gal) 501 gms/liter (4.2 lbs/gal) 495 gms/liter (4.1 lbs/gal)

Comments Wait 24 hours before sanding, compounding or recoating.


* Mixing with flex agent will alter dry times and viscosity.

Materials described are for application by professional trained personnel only using proper equipment. Products may be hazardous & should be used according to label directions & technical data information. Appropriate respiratory protection should be worn at
all times while products are in use—read product label and Material Safety Data Sheet (MSDS) for specific details. Statements & methods described are based upon the latest standard of technology known to the manufacturer. Application procedures cited are
suggestions only & are not to be interpreted as warranty for events resulting from their use. Dilution ratios are intended to provide maximum performance within the typical Volatile Organic Compound (VOC) restriction for product use. Specific VOC limits need to
be referenced to verify local compliance. Altering the solvent or dilution ratio may impact VOC compliance. User is solely responsible to ensure product use and application is in accordance with all applicable regulatory, legislative, and municipal requirements.
Click on logo to return to Table of Contents

C L E A R C O AT S

LC4200 Low VOC Clearcoat


250 gms/liter (2.1 lbs/gal) VOC

Description: Limco LC4200 Clearcoat is a low 250 gms/liter (2.1 lbs/gal) VOC acrylic urethane clearcoat for use
over Supreme PLUS Low VOC Basecoat colors. LC4200 is easy to apply and has excellent gloss and
leveling.

Materials: Clearcoat: LC4200


Hardeners: LH601
LH604
LH606
Flex Agent: 892

Basecoat: Supreme PLUS Low VOC Basecoat 420 gms/liter (3.5 lbs/gal) VOC

Remarks: Always check local VOC laws to ensure that the use of these Limco products is compliant in your
area.
LC4200 is not covered by a warranty and should not be used with warrantable systems.

US Rev. 8/21/17
T E C H N I C A L D A T A

LC4200 Low VOC Clearcoat


250 gms/liter (2.1 lbs/gal) VOC
Flexed
Mixing ratio: 4:1 8:2:1
Clear 4 parts LC4200 8 parts LC4200
Hardener 1 part LH601, LH604 or LH606 2 parts LH601, LH604 or LH606
Flex Agent — 1 part 892

Potlife at 68°F/20°C 1.5 hours 1.5 hours

Spray viscosity Ford #4


S 15 - 17 seconds 15 - 17 seconds
@ 68°F/20°C

Gravity gun nozzle HVLP 1.1 - 1.3 mm 1.1 - 1.3 mm

Spray pressure HVLP at the cap 9 - 10 psi 9 - 10 psi

Application 2 - 3 coats 2 - 3 coats

Flash-off time @ 68°F/20°C 5 minutes between coats 5 minutes between coats

Film build 2.0 - 2.4 mils 2.0 - 2.4 mils

Coverage 659 sq. ft./gal @ 1.0 mils 693 sq. ft./gal @ 1.0 mils

Drying:
68°F/20°C 45 minutes dust free; 45 minutes dust free;
8 hours to handle 8 hours to handle
140°F/60°C 30 minutes; must allow 5 minutes 30 minutes; must allow 5 minutes
flash before force dry flash before force dry
Infra red short wave 6 - 10 minutes 6 - 10 minutes
Infra red medium wave N/A N/A

Sanding:
Wet by Hand 1200 or Finer 1200 or Finer

Dry by Hand P1200 or Finer P1200 or Finer

Dry by Machine P1200 or Finer P1200 or Finer

VOC as applied 139 gms/liter (1.2 lbs/gal) 151 gms/liter (1.3 lbs/gal)

Comments Wait 24 hours before sanding, compounding or recoating.

Materials described are for application by professional trained personnel only using proper equipment. Products may be hazardous & should be used according to label directions & technical data information. Appropriate respiratory protection should be worn at
all times while products are in use—read product label and Material Safety Data Sheet (MSDS) for specific details. Statements & methods described are based upon the latest standard of technology known to the manufacturer. Application procedures cited are
suggestions only & are not to be interpreted as warranty for events resulting from their use. Dilution ratios are intended to provide maximum performance within the typical Volatile Organic Compound (VOC) restriction for product use. Specific VOC limits need to
be referenced to verify local compliance. Altering the solvent or dilution ratio may impact VOC compliance. User is solely responsible to ensure product use and application is in accordance with all applicable regulatory, legislative, and municipal requirements.
Click on logo to return to Table of Contents

C L E A R C O AT S

LC4300 European Style Clear


U.S. National Rule VOC

Description: Limco LC4300 Clearcoat is an acrylic urethane clear for use over Limco Supreme PLUS Basecoat
colors. It is designed to increase the profitability and productivity of the repair facility. It is U.S.
National Rule compliant, easy to apply and has excellent gloss and leveling.

Materials: Clearcoat: LC4300


Hardeners: LH501
LH505
Flex Agent: 892

Basecoat: Supreme PLUS Basecoat

Remarks: Always check local VOC laws to ensure that the use of these Limco products is compliant in your
area.
LC4300 is not covered by a warranty and should not be used with warrantable systems.

US Rev. 11/1/16
T E C H N I C A L D A T A

LC4300 European Style Clear


U.S. National Rule VOC
Flexed
Mixing ratio: 2:1 4:1
Clear 2 parts LC4300 4 parts LC4300
Flex Agent — 1 part 892, then 4:3
— — 4 parts above mixture
Hardener 1 part LH501 or LH505 3 parts LH501 or LH505

Potlife at 68°F/20°C 2+ hours 4 hours

Spray viscosity Ford #4


S 16 seconds 16 seconds
@ 68°F/20°C

Gravity gun nozzle HVLP 1.3 - 1.5 mm 1.3 - 1.5 mm

Spray pressure HVLP at the cap 9 - 10 psi 9 - 10 psi

Application 2 medium wet coats 2 medium wet coats

Flash-off time @ 68°F/20°C 5 minutes between coats 5 minutes between coats

Film build 2.0 - 2.4 mils 2.0 - 2.4 mils

Coverage 548 sq. ft./gal @ 1.0 mils 603 sq. ft./gal @ 1.0 mils

Drying:
68°F/20°C 30 minutes dust free; 30 minutes dust free;
8 hours to handle 8 hours to handle
140°F/60°C 30 minutes; must allow 5 minutes 30 minutes; must allow 5 minutes
flash before force dry flash before force dry
Infra red short wave 10 - 20 minutes 10 - 20 minutes
Infra red medium wave N/A N/A

Sanding:
Wet by Hand 1500 or Finer 1500 or Finer

Dry by Hand P1500 or Finer P1500 or Finer

Dry by Machine P1500 or Finer P1500 or Finer

VOC VOC compliant in National Rule areas

Comments Wait 24 hours before sanding, compounding or recoating.

Materials described are for application by professional trained personnel only using proper equipment. Products may be hazardous & should be used according to label directions & technical data information. Appropriate respiratory protection should be worn at
all times while products are in use—read product label and Material Safety Data Sheet (MSDS) for specific details. Statements & methods described are based upon the latest standard of technology known to the manufacturer. Application procedures cited are
suggestions only & are not to be interpreted as warranty for events resulting from their use. Dilution ratios are intended to provide maximum performance within the typical Volatile Organic Compound (VOC) restriction for product use. Specific VOC limits need to
be referenced to verify local compliance. Altering the solvent or dilution ratio may impact VOC compliance. User is solely responsible to ensure product use and application is in accordance with all applicable regulatory, legislative, and municipal requirements.
Click on logo to return to Table of Contents

C L E A R C O AT S

LC4400 Low VOC


European Style Clear
250 gms/liter (2.1 lbs/gal) VOC

Description: Limco LC4400 Clearcoat is a low 250 gms/liter (2.1 lbs/gal) VOC acrylic urethane clearcoat for use
over Supreme PLUS Low VOC Basecoat colors. LC4400 is easy to apply and has excellent gloss and
leveling.

Materials: Clearcoat: LC4400


Hardeners: LH501
LH505
Flex Agent: 892

Basecoat: Supreme PLUS Low VOC Basecoat 420 gms/liter (3.5 lbs/gal) VOC

Remarks: Always check local VOC laws to ensure that the use of these Limco products is compliant in your
area.
LC4400 is not covered by a warranty and should not be used with warrantable systems.

US Rev. 11/1/16
T E C H N I C A L D A T A

LC4400 Low VOC European Style Clear


250 gms/liter (2.1 lbs/gal) VOC
Flexed
Mixing ratio: 2:1 4:1
Clear 2 parts LC4400 4 parts LC4400
Flex Agent — 1 part 892, then 4:3
— — 4 parts above mixture
Hardener 1 part LH501 or LH505 3 parts LH501 or LH505

Potlife at 68°F/20°C 3+ hours 3+ hours

Spray viscosity Ford #4


S 12 seconds 12 seconds
@ 68°F/20°C

Gravity gun nozzle HVLP 1.3 - 1.5 mm 1.3 - 1.5 mm

Spray pressure HVLP at the cap 9 - 10 psi 9 - 10 psi

Application 2 medium wet coats 2 medium wet coats

Flash-off time @ 68°F/20°C 5 minutes between coats 5 minutes between coats

Film build 2.0 - 2.4 mils 2.0 - 2.4 mils

Coverage 492 sq. ft./gal @ 1.0 mils 563 sq. ft./gal @ 1.0 mils

Drying:
68°F/20°C 30 minutes dust free; 30 minutes dust free;
8 hours to handle 8 hours to handle
140°F/60°C 30 minutes; must allow 5 minutes 30 minutes; must allow 5 minutes
flash before force dry flash before force dry
Infra red short wave 10 - 20 minutes 10 - 20 minutes
Infra red medium wave N/A N/A

Sanding:
Wet by Hand 1200 or Finer 1200 or Finer

Dry by Hand P1200 or Finer P1200 or Finer

Dry by Machine P1200 or Finer P1200 or Finer

VOC Compliant in areas requiring VOCs of 250 gms/liter (2.1 lbs/gal)

Comments Wait 24 hours before sanding, compounding or recoating.

Materials described are for application by professional trained personnel only using proper equipment. Products may be hazardous & should be used according to label directions & technical data information. Appropriate respiratory protection should be worn at
all times while products are in use—read product label and Material Safety Data Sheet (MSDS) for specific details. Statements & methods described are based upon the latest standard of technology known to the manufacturer. Application procedures cited are
suggestions only & are not to be interpreted as warranty for events resulting from their use. Dilution ratios are intended to provide maximum performance within the typical Volatile Organic Compound (VOC) restriction for product use. Specific VOC limits need to
be referenced to verify local compliance. Altering the solvent or dilution ratio may impact VOC compliance. User is solely responsible to ensure product use and application is in accordance with all applicable regulatory, legislative, and municipal requirements.
Click on logo to return to Table of Contents

C L E A R C O AT S

LC4500 Express Clear


U.S. National Rule VOC

Description: Limco LC4500 Express Clear is a U.S. National Rule Compliant acrylic urethane clear for use over
Limco Supreme PLUS Basecoat colors. It is designed to increase the profitability and productivity of
the repair facility. LC4500 is an easy to apply two coat clear that has excellent gloss and leveling.
LC4500 offers a range of reducers to meet your temperature needs.

Materials: Clearcoat: LC4500


Hardeners: LHF
LHM
LHS
Reducers: LR10
LR11
LR12
LR13
LR15
Flex Agent: 892

Basecoats: Supreme PLUS Basecoat

Remarks: Always check local VOC laws to ensure that the use of these Limco products is compliant in your
area.
LC4500 is not covered by a warranty and should not be used with warrantable systems

US Rev. 11/1/16
T E C H N I C A L D A T A

LC4500 Express Clear


U.S. National Rule VOC
Flexed
Mixing ratio: 8:2:1 4:2:1:1
Clear 8 parts LC4500 4 parts LC4500
Hardener 2 parts LHF, LHM or LHS 2 parts LHF, LHM or LHS
Reducer 1 part LR10, LR11, LR12, LR13 or LR15 1 part LR10, LR11, LR12, LR13 or LR15
Flex Agent — 1 part 892

Potlife at 68°F/20°C 2 - 3 hours 2 hours

Spray viscosity Ford #4


S 13 - 15 seconds 12 - 14 seconds
@ 68°F/20°C

Gravity gun nozzle HVLP 1.1 - 1.3 mm 1.1 - 1.3 mm

Spray pressure HVLP at the cap 9 - 10 psi 9 - 10 psi

Application 2 - 3 coats 2 - 3 coats

Flash-off time @ 68°F/20°C 5 minutes between coats 5 minutes between coats

Film build 2.0 - 3.0 mils 2.0 - 3.0 mils

Coverage 582 sq. ft./gal @ 1.0 mils 662 sq. ft./gal @ 1.0 mils

Drying:
68°F/20°C 15 minutes dust free; 15 minutes dust free;
3 - 4 hours to handle 3 - 4 hours to handle
140°F/60°C 30 minutes; may be handled or 30 minutes; may be handled or
polished after cool down polished after cool down
Infra red short wave 6 - 10 minutes 6 - 10 minutes
Infra red medium wave N/A N/A

Sanding:
Wet by Hand 1200 or Finer 1200 or Finer

Dry by Hand P1200 or Finer P1200 or Finer

Dry by Machine P1200 or Finer P1200 or Finer

VOC as applied 532 gms/liter (4.4 lbs/gal) 490 gms/liter (4.1 lbs/gal)

Comments Wait 8 hours before sanding, compounding or recoating.

Materials described are for application by professional trained personnel only using proper equipment. Products may be hazardous & should be used according to label directions & technical data information. Appropriate respiratory protection should be worn at
all times while products are in use—read product label and Material Safety Data Sheet (MSDS) for specific details. Statements & methods described are based upon the latest standard of technology known to the manufacturer. Application procedures cited are
suggestions only & are not to be interpreted as warranty for events resulting from their use. Dilution ratios are intended to provide maximum performance within the typical Volatile Organic Compound (VOC) restriction for product use. Specific VOC limits need to
be referenced to verify local compliance. Altering the solvent or dilution ratio may impact VOC compliance. User is solely responsible to ensure product use and application is in accordance with all applicable regulatory, legislative, and municipal requirements.
Click on logo to return to Table of Contents

C L E A R C O AT S

LC4800 Low 2.0 VOC Express Clear


250 gms/liter (2.1 lbs/gal) VOC

Description: Limco LC4800 Low 2.0 VOC Express Clear is a two component, 250 gms/liter (2.1 lbs/gal) VOC
compliant fast acrylic urethane clear for use over Supreme PLUS Low VOC Basecoat colors. It is
designed to accommodate fast air-dry and quick bake conditions, increasing the productivity and
profitability for the repair facility. It is ideal for spot and panel repairs with easy application and
good appearance.

Materials: Clearcoat: LC4800


Hardeners: LH601
LH604
LH606
Flex Agent 892

Basecoat: Supreme PLUS Low VOC Basecoat 420 gms/liter (3.5 lbs/gal) VOC

Remarks: Always check local VOC laws to ensure that the use of these Limco products is compliant in your
area.
LC4800 is not covered by a warranty and should not be used with warrantable systems

US Rev. 11/1/16
T E C H N I C A L D A T A

LC4800 Low 2.0 VOC Express Clear


250 gms/liter (2.1 lbs/gal) VOC
Flexed
Mixing ratio: 4:1 8:2:1
Clear 4 parts LC4800 8 parts LC4800
Hardener 1 part LH601, LH604 or LH606 2 parts LH601, LH604 or LH606
Flex Agent — 1 part 892

Potlife at 68°F/20°C 2 - 3 hours 2 - 3 hours

Spray viscosity Ford #4


S 13 - 15 seconds 13 - 15 seconds
@ 68°F/20°C

Gravity gun nozzle HVLP 1.1 - 1.3 mm 1.1 - 1.3 mm

Spray pressure HVLP at the cap 9 - 10 psi 9 - 10 psi

Application 2 wet coats 2 wet coats

Flash-off time @ 68°F/20°C 5 minutes between coats 5 minutes between coats

Film build 2.0 - 2.5 mils 2.0 - 2.5 mils

Coverage 632 sq. ft./gal @ 1.0 mils 668 sq. ft./gal @ 1.0 mils

Drying:
68°F/20°C 15 minutes dust free; 20 - 25 minutes dust free
4 hours to handle
140°F/60°C 30 minutes; may be handled or 30 minutes; may be handled or
polished after cool down polished after cool down
Infra red short wave 8 - 10 minutes 8 - 10 minutes
Infra red medium wave N/A N/A

Sanding:
Wet by Hand 1500 or Finer 1500 or Finer

Dry by Hand P1500 or Finer P1500 or Finer

Dry by Machine P1500 or Finer P1500 or Finer

VOC as applied 159 gms/liter (1.4 lbs/gal) 169 gms/liter (1.5 lbs/gal)

Comments Wait 8 hours before sanding, compounding or recoating.

Materials described are for application by professional trained personnel only using proper equipment. Products may be hazardous & should be used according to label directions & technical data information. Appropriate respiratory protection should be worn at
all times while products are in use—read product label and Material Safety Data Sheet (MSDS) for specific details. Statements & methods described are based upon the latest standard of technology known to the manufacturer. Application procedures cited are
suggestions only & are not to be interpreted as warranty for events resulting from their use. Dilution ratios are intended to provide maximum performance within the typical Volatile Organic Compound (VOC) restriction for product use. Specific VOC limits need to
be referenced to verify local compliance. Altering the solvent or dilution ratio may impact VOC compliance. User is solely responsible to ensure product use and application is in accordance with all applicable regulatory, legislative, and municipal requirements.
Click on logo to return to Table of Contents

MISCELLANEOUS

892 Flex Agent

Description: Limco 892 Flex Agent is a urethane additive that gives flexibility to Limco Undercoats, Topcoats and
Clearcoats. Limco 892 is formulated to resist fading, stone chipping and chemical staining while
increasing the durability and flexibility of most interior and exterior parts.

Mixing: When finishing flexible parts, refer to the appropriate technical data sheets for detailed mixing
ratios and processing information.
Undercoat:
• 800K
• 800K tinted wet-on-wet sealer
• LP610 primer surfacer
• LP610 sealer
• LP620 sealer (National Rule and Low VOC)
• LS800
Topcoat:
• Supreme PLUS Urethane Single Stage National Rule (with LA2799 or LA2999)
• Supreme PLUS Low VOC Urethane Single Stage (with LA2799 or LA2899) for both
340 gms/liter (2.8 lbs/gal) VOC and 420 gms/liter (3.5 lbs/gal) VOC
Clearcoat:
• LC4000
• LC4100
• LC4200
• LC4500
• LC4800

Remarks: Always check local VOC laws to ensure that the use of these Limco products is compliant in your
area.
For information on preparing plastic parts, refer to “Standard Preparation for Plastic Parts” in the
APPLICATION PROCEDURES section of the Limco Technical Manual.

Materials described are for application by professional trained personnel only using proper equipment. Products may be hazardous & should be used according to label directions & technical data information. Appropriate respiratory protection should be worn at
all times while products are in use—read product label and Material Safety Data Sheet (MSDS) for specific details. Statements & methods described are based upon the latest standard of technology known to the manufacturer. Application procedures cited are
suggestions only & are not to be interpreted as warranty for events resulting from their use. Dilution ratios are intended to provide maximum performance within the typical Volatile Organic Compound (VOC) restriction for product use. Specific VOC limits need to
be referenced to verify local compliance. Altering the solvent or dilution ratio may impact VOC compliance. User is solely responsible to ensure product use and application is in accordance with all applicable regulatory, legislative, and municipal requirements.

US Rev. 11/1/16
Click on logo to return to Table of Contents

MISCELLANEOUS

LE800 Fisheye Eliminator

Description: Limco LE800 Fisheye Eliminator is specially developed for use in Limco Supreme PLUS Single Stage
Topcoats and Limco Clearcoats.

Mixing: Add up to 1 ounce (approximately 28 grams) of Limco LE800 Fisheye Eliminator per ready for use
gallon of topcoats and clearcoats.

Remarks: Always check local VOC laws to ensure that the use of these Limco products is compliant in your
area.
Only use if fisheyes or craters are encountered.
DO NOT use in any undercoats or basecoats.

Materials described are for application by professional trained personnel only using proper equipment. Products may be hazardous & should be used according to label directions & technical data information. Appropriate respiratory protection should be worn at
all times while products are in use—read product label and Material Safety Data Sheet (MSDS) for specific details. Statements & methods described are based upon the latest standard of technology known to the manufacturer. Application procedures cited are
suggestions only & are not to be interpreted as warranty for events resulting from their use. Dilution ratios are intended to provide maximum performance within the typical Volatile Organic Compound (VOC) restriction for product use. Specific VOC limits need to
be referenced to verify local compliance. Altering the solvent or dilution ratio may impact VOC compliance. User is solely responsible to ensure product use and application is in accordance with all applicable regulatory, legislative, and municipal requirements.

US Rev. 11/1/16
Click on logo to return to Table of Contents

MISCELLANEOUS

LF01 Low VOC Flattener

Description: Limco LF01 is a flattening agent that may be added to all Limco Low VOC Supreme PLUS Single
Stage Topcoats and Limco Clearcoats for gloss reduction. Limco LF01 mixes easily and allows
flattening to the extent desired.

Mixing: Stir product thoroughly for 5 - 10 minutes before using.


Add up to 100% of LF01 to Ready For Use product (paint and hardener, reducer) Limco mixture.
Additional reduction is optional.
Ensure proper flash-off periods are observed when spraying flattened products to prevent
additional gloss.
Polishing finishes containing LF01 will cause gloss levels to increase.

Remarks: Always check local VOC laws to ensure that the use of these Limco products is compliant in your
area.
DO NOT use LF01 in any Basecoat color.
Can be mixed with any Low VOC Limco product and still be VOC compliant.
RFU formulas for Limco Clearcoats are available.

Materials described are for application by professional trained personnel only using proper equipment. Products may be hazardous & should be used according to label directions & technical data information. Appropriate respiratory protection should be worn at
all times while products are in use—read product label and Material Safety Data Sheet (MSDS) for specific details. Statements & methods described are based upon the latest standard of technology known to the manufacturer. Application procedures cited are
suggestions only & are not to be interpreted as warranty for events resulting from their use. Dilution ratios are intended to provide maximum performance within the typical Volatile Organic Compound (VOC) restriction for product use. Specific VOC limits need to
be referenced to verify local compliance. Altering the solvent or dilution ratio may impact VOC compliance. User is solely responsible to ensure product use and application is in accordance with all applicable regulatory, legislative, and municipal requirements.

US Rev. 11/1/16
Click on logo to return to Table of Contents

MISCELLANEOUS

LF10 Flattening Agent

Description: Limco LF10 is a flattening agent that may be added to all Limco Supreme PLUS Single Stage
Topcoats and Limco Clearcoats for gloss reduction. Limco LF10 mixes easily and allows flattening
to the extent desired.

Mixing: Stir product thoroughly for 5 - 10 minutes before using.


Add 25% - 50% of LF10 to the catalyzed (paint and hardener, no reducer) Limco mixture. Additional
reduction is optional.
Ensure proper flash-off periods are observed when spraying flattened products to prevent additional
gloss.
Polishing finishes containing LF10 will cause gloss levels to increase.

Remarks: Always check local VOC laws to ensure that the use of these Limco products is compliant in your
area.
DO NOT use LF10 in any Basecoat color.
Cannot be mixed with any Low VOC Limco product and still be VOC compliant.
RFU formulas for Limco Clearcoats are available.

Materials described are for application by professional trained personnel only using proper equipment. Products may be hazardous & should be used according to label directions & technical data information. Appropriate respiratory protection should be worn at
all times while products are in use—read product label and Material Safety Data Sheet (MSDS) for specific details. Statements & methods described are based upon the latest standard of technology known to the manufacturer. Application procedures cited are
suggestions only & are not to be interpreted as warranty for events resulting from their use. Dilution ratios are intended to provide maximum performance within the typical Volatile Organic Compound (VOC) restriction for product use. Specific VOC limits need to
be referenced to verify local compliance. Altering the solvent or dilution ratio may impact VOC compliance. User is solely responsible to ensure product use and application is in accordance with all applicable regulatory, legislative, and municipal requirements.

US Rev. 11/1/16