You are on page 1of 2

VIBRATION ANALYSIS RUSH REPORT DATE: 19.01.

18
Plant: ROCK GRINDING
Equipment: VENT FAN-NEW (GB631)
Monitored On: 19.01.18
EQUIPMENT DETAILS:

MOTOR DETAILS:
FAN
RPM: 1500 , HP: , KW:
BEARING DETAILS:
BEARING DETAILS:
NA
NA

EQUIPMENT DETAILS:

Velocity in mm/sec, ACC in gE

ACCEPTABLE
LIMIT: DIR 23.11.17 02.01.18 18.01.18
7.1/2.0
H 9.4 9.3 9.5
MOTOR NDE V 2.9 3.0 4.6
A 4.3 4.5 6.2
H 7.0 9.9 10.1
GROUP II
MOTOR DE V 4.9 3.3 2.0
7.1 A 4.8 5.5 5.7
H 6.4 9.0 9.5
FAN DE V 1.0 1.2 1.2
A 2.7 6.4 4.9
H 7.8 10.9 10.8
FAN NDE V 3.0 4.3 3.8
A 2.8 3.5 6.5

IRM- INTEGRATED RELIABILITY MAINTENANCE


OBSERVATIONS & ANALYSIS:
The health condition of equipment vibrations is in Critical zone.
Spectrum analysis indicating Dominant 1X RPM at equipment bearings.
FFT Spectrum is also indicating misalignment symptoms at equipment bearings.

SUGGESTED ACTION PLANS:


Check and clean the fan impeller for any dust accumulation.
Also check the coupling for any inaccuracies in the next available opportunity.
Achieve precision alignment between motor & fan after above correction.
Reassess the health condition of equipment after above correction; perform insitu dynamic balancing if necessary.
Spectrum
FAN NDE-HORIZONTAL
v rms [mm/s] BAG FILTER VENT FAN (NEW) - GB631\ FAN\ FAN NDE H\ 1004 Mach.spectr. > 600 18-Jan-18 2:31:50 PM
12.0
11.5 (25.00 / 10.13)
11.0 RPM: 1475 (24.58Hz)

10.5
10.0

9.5
9.0
8.5

8.0
7.5
7.0

6.5
6.0

5.5
5.0
4.5

4.0

3.5
3.0

2.5
2.0
1.5

1.0

0.5
0.0
0 50 100 150 200 250 300 350 400 450 500 550 600 650 700 750 800
f [Hz]

IRM- INTEGRATED RELIABILITY MAINTENANCE

You might also like