Installation Manual
IMONEX Model EM10, EM12, EM20, EM21 Coin Multiplier Board
• General Description was no voltage to the coin switch, but there is voltage at the acceptor
when a coin is accepted use Option B. If there is no voltage in either
The coin multiplier board is capable of multiplying currency values for the case, use Option C.
IMONEX R,V,Z-Series acceptors. It may be used in combination with 5. Turn on the machine that the acceptor is installed in.
mechanical switches, or the IMONEX optical coin sensing assembly. 6. Verify that there is power to the multiplier board by checking that the
Multiplier values are factory or field set by DIP switches at 1 or 2 pulses green LED on the multiplier board is glowing.
for the lower currency coin and 2, 3, 4, 5, 6, 7, 8, or 10 pulses for the 7. Insert a coin into the acceptor and verify correct operation by
higher currency coin. Consult factory for other multiplier combinations. checking the credits on the machine, and by counting how many
The pulse length can be field set by DIP switches for either 50mS or times the LED flashes off on the multiplier unit. The LED should
150mS duration. flash off for every credit issued.

Wiring Diagram for Coin Sense


• Specifications
Option A - Positive True Connection (Normally Open Dry Contact)
Supply Voltage: 12-24 VDC or VAC +10%, -15%, 50/60 Hz
Current Draw: 20 mAmps 100 mAmps Peak COIN
Blue
COIN
Switching Voltage: 2.5-30 VDC @1.5Ma Maximum Sink +V
Pulse Timing: 50mSec or 150mSec Field Adjustable Red
Operating Temperature Range: -30 to 70°C 3.3k
Operating Humidity: 0-95% Non-Condensing +5V

• Installation Preparation
Option B - Positive True Connection (Sourcing, +5V pulse)
1. Turn on the machine that the acceptor is to be installed into.
Blue COIN
2. Using a voltmeter set to DC volts, measure the voltage across the COIN COIN
coin switch terminal. Record the voltage.
Red
3. Switch the voltmeter to AC volts, measure the voltage across the coin
3.3k Orange
switch terminal. Record the voltage. +5V
4. If the meter read AC voltage greater than 2 volts, this multiplier board
is not designed for use with your machine. Contact the factory for a Brown
recommendation of a different multiplier board. Do not install the
multiplier as it may damage the unit. Option C - Negative True Connection (Sinking)
5. If the unit read between 2.5 and 30 DC volts across the coin switch COIN
terminals, use the voltmeter set to DC volts to determine which wire COIN
is positive. Blue
COIN
6. If there was no voltage across the coin switch, verify that the unit is
Red
turned on and crediting coins. If the unit is working and there still is
no voltage, then disconnect the acceptor from the coin switch wires. 3.3k Orange
+5V
Using a voltmeter set to DC volts, measure the voltage across the
coin sense wires on the acceptor as a coin is dropped into the Brown
acceptor. If there is a short change in voltage as the coin is accepted
then wiring diagram Option B should be used, else you will use
wiring diagram Option C. • Multiplier Value Modification
7. The multiplier board requires power to operate. The next step is to
find a suitable source of power for the board. The board is shipped from the factory with a multiplier
8. Using a voltmeter, find a 12-24VDC, or VAC source of power, and
run wires to the acceptor as required. ! value that matches the value ratio of the two coins
that the acceptor was designed for. Do not set the
DIP Switches unless other values are required!
• Installing The New Acceptor

1. Turn off the power. Note: It is imperative that these operations be performed in the
2. Remove the old coin acceptor and replace with the IMONEX following order. If unit is inadvertently powered down and back
Acceptor. up with the switches in the wrong locations, then the process
3. Wire the power found in step 8 above to the multiplier board as must be restarted at Step 1.
follows:
Yellow Wire – (+)12-24 Volts AC or DC Step 1 - Change the Multiplier Value
Black Wire – (-)12-24 Volts AC or DC Multiplier mode is typically used to update a Quarter only machine to a
Green Wire – Chassis Ground Quarter / Dollar combination. For this combination, the controller DIP
4. There are three ways to wire the coin switch pulse. If there was switches would be set at 1 pulse for the smaller currency coin (Quarter),
voltage on the coin switch wires Option A should be used. If there and 4 pulses for the larger currency coin (Dollar).

ED00003, REV C, 1/01


Example Switch Settings for $2.00 Vend Amount

ON
Example Switch Settings for Dollar / Quarter Combination

1 2 3 4 5 6
Toggle to Vend Setting Mode
Multiplier Setting Mode

ON
8 X $0.25 = $2.00 Vend Amount for Quarter
1 2 3 4 5 6

50 ms Timing on Switch Pulse


- Denotes Off Position
High Currency Coin = 4 Pulses
- Denotes On Position
Low Currency Coin = 1 Pulse
Vend Amount DIP Switch Settings Chart
- Denotes Off Position
Vend Quarter Sw1 Sw2 Sw3 Sw4 Sw5 Sw6
- Denotes On Position Amount Amount
N/A N/A Off Off Off Off Off Off
2X $0.50 Off Off Off Off Off On
1. Power down unit. 3X $0.75 Off Off Off Off On Off
2. Set switch 1 to the on position 4X $1.00 Off Off Off Off On On
3. Set switch 2 to Off position for 50ms pulse length or to the 5X $1.25 Off Off Off On Off Off
On position for 150ms pulse length. 6X $1.50 Off Off Off On Off On
4. Set switches 3,4,5 and 6 per DIP Switch Settings Chart. 7X $1.75 Off Off Off On On Off
5. Power up unit. The new settings should now be stored in 8X $2.00 Off Off Off On On On
the memory. 9X $2.25 Off Off On Off Off Off
10 X $2.50 Off Off On Off Off On
Pulse Length DIP Switch Settings 11 X $2.75 Off Off On Off On Off
12 X $3.00 Off Off On Off On On
Switch 2, Pulse Length
13 X $3.25 Off Off On On Off Off
ON

14 X $3.50 Off Off On On Off On


15 X $3.75 Off Off On On On Off
2

50mS Timing on Switch Pulse


16 X $4.00 Off Off On On On On
150mS Timing on Switch Pulse 17 X $4.25 Off On Off Off Off Off
2

18 X $4.50 Off On Off Off Off On


- Denotes Off Position 19 X $4.75 Off On Off Off On Off
- Denotes On Position
20 X $5.00 Off On Off Off On On
21 X $5.25 Off On Off On Off Off
Multiplier DIP Switch Settings Chart 22 X $5.50 Off On Off On Off On
23 X $5.75 Off On Off On On Off
Low High Sw1 Sw2 Sw3 Sw4 Sw5 Sw6 24 X $6.00 Off On Off On On On
Currency Currency 25 X $6.25 Off On On Off Off Off
Pulses Pulses 26 X $6.50 Off On On Off Off On
1 2 On Off Off Off Off 27 X $6.75 Off On On Off On Off
1 3 On Off Off On Off 28 X $7.00 Off On On Off On On
1 4 On Off On Off Off 29 X $7.25 Off On On On Off Off
1 5 On Off On On Off 30 X $7.50 Off On On On Off On
See Pulse Length Setting

1 6 On On Off Off Off 31 X $7.75 Off On On On On Off


1 7 On On Off On Off 32 X $8.00 Off On On On On On
1 8 On On On Off Off
1 10 On On On On Off • Trouble-Shooting Instructions
2 2 On Off Off Off On • No power to multiplier board.
2 3 On Off Off On On 1. Verify that there is power to the machine, and that it is turned
2 4 On Off On Off On on.
2 5 On Off On On On 2. Verify that the connectors are well seated on the multiplier
2 6 On On Off Off On board.
2 7 On On Off On On 3. Check with a voltmeter for 12-24 VDC/VAC between the
2 8 On On On Off On yellow and black wires on the multiplier board.
2 10 On On On On On • No credits issued to the machine.
1. Verify that there is power to the multiplier by checking for a
Step 2 - Change the Vend Amount Value (If needed) glowing LED on the board when the unit is turned on.
2. Check that the multiplier LED flashes off once for every credit
Vend mode is used to send a signal after the vend amount has been when a coin is inserted into the acceptor.
accumulated. For example, if we assume that a Quarter is the smallest 3. Be sure in Option A that the positive voltage signal is connected
currency of the two coins, and we want a $2.00 vend, then the vend setting to the blue wire.
would be 8. 4. If the voltages seem to be correct, and the LED is flashing when
1. Power down unit a coin is inserted into the acceptor, set the pulse length at 150ms
2. Set switch 1 to the Off position. timing per multiplier setup.
3. Set switches 2,3,4,5 and 6 per Vend DIP Switch Settings Chart. • Wrong credits issued to the machine.
4. Power up unit. The new settings should now be stored in the 1. Check that the LED is pulsing off once for every credit when a
memory. coin is inserted into the acceptor. If not pulsing the proper
amount of times, check that the multiplier and vend amount
settings are correct. If the LED is pulsing correctly set the pulse
length to 150ms timing per multiplier setup.
ED00003, REV C, 1/01