You are on page 1of 2

BENZOIC ACID STIMULATION

SERVICES
PRODUCTS
Product Information

AND

Applications

Benzoic Acid is a temporary diverting agent used in acidizing stimulation treatments in sandstone and carbonate
reservoirs. Although soluble in both hydrocarbon and water-based fluids, the rate of solubility is sufficiently low to
allow mixing and pumping with both fluids. Benzoic acid is effective in diverting treatments in both open hole and
cased wells and is stable at temperatures to 350°F (177°C).

Features

Proven T rack Record


Track
Very effective for diverting acid treatments and fracture stimulations for many years. Equally effective in cased
hole, open hole or horizontal wells.

Non-Damaging Diversion
Diverts treatments evenly across the entire zone of interest with no permanent permeability damage.

High T emperature Stability


Temperature
Stable to 300°F (149°C). Cooldown effects allow usage in wells with bottomhole temperatures over 400°F (204°C).

Superior Solubility Properties


The only diverter 100 % soluble in both hydrocarbons and water.

Slow Rate of Solubility


Rate of solubility slow, yet rapid enough to allow well clean-up and return to full production in short period of to
time.

Efficient
Effective at concentrations from 0.25 to 2.0 ppg (29.95 to 239.6 kg/m3).

Benefits

Excellent, dependable diversion.


Improves zonal coverage for more successful acid treatments.
Non damaging due to its solubility in water and hydrocarbons.
Economical to use.
Broad range of applications.

Technical Data

Specific Gravity: 1.26


Melting Point: 251 °F (122°C)
Solubility: Water 0.037 ppg (4.43 kg/m3) @ 85°F (29°C)
0.221 ppg (26.48 kg/m3) @ 175°F (79°C)
Kerosene 0.224 ppg (26.84 kg/m3) @ 85°F (29°C)
0.573 ppg (68.65 kg/m3) @ 175°F (79°C)

BJ SERVICES COMPANY
COMPANY
BENZOIC ACID
Product Information

Technical Data (cont'd.)

Solubility of Benzoic Acid


Half Life vs Temperature

7
Half Life: The amount of time required to
6 dissolve half the amount of Benzoic Acid
Half Life Time, Hours

at a given temperature.
5

0
100 120 140 160 180 200 220 240 260 280
(38) (49) (60) (71) (82) (93) (104) (116) (127) (138)
Temperature, °F (°C)

Open Hole,
Open Hole, Cased Hole,
Unfractured or
Fractured Perforations
Static Bottom- Slotted Liner
Hole Temperature
Temperature
ppg ppg ppg
lbs/ft lbs/ft lbs/ft
(kg/m3) (kg/m3) (kg/m3)

Below 200°F 1/2 1 1 1 1/4 1


(93°C) (119.8) (119.8) (119.8)
200° to 250°F 1 1 2 1.5 1/2 1.5
(93° to 121°C) (119.8) (179.7) (179.7)
250° to 350°F 2 1.5 3 2 1 2
(121° to 177°C) (179.7) (239.6) (239.6)

References

Confidential Mixing Instructions


MSDS

The above features and/or data are supplied solely for informational purposes and BJ Services Company makes no guarantees or warranties, either expressed or implied, with respect to their accuracy or use. All product warranties and
guarantees shall be governed by the BJ Services Company standard at the time of sale or delivery of service. Actual product performance or availability depends on the timing and location of the job, the type of job and the particular
characteristics of each job. This document is controlled by the reference date. To ensure that this is the current version, please reference the Services section of the BJ Services Website (www.bjservices.com) or ask your BJ representative.

BJ SERVICES COMPANY
COMPANY
10/10/00