01 / Nomenclature

02 / Product Lineup
03 / Features of outdoor unit
04 / Features of indoor unit
05 / Installation and Malfunction
06 / Control
01. Nomenclature
 Indoor unit
01. Nomenclature
 Outdoor unit
02. Product Lineup
2.1  T3 R410A 50Hz Top-discharge Series

Outdoor unit Indoor unit

2 compressors,
1 circuit
Floor standing
type
8HP/10HP/12HP
8HP/10HP/12HP

8HP/10HP
H.S.P duct type 2 compressors,
1 circuit 8HP/10HP
8HP/10HP

1st Generation
M.S.P duct type 8HP/10HP 12HP 16HP
8HP/10HP 12HP 16HP
Notes: 12HP Driven by two 8HP
▲Cooling Only; ▲Cooling and heating outdoor units
02. Product Lineup
2.1  T1 R410a 50Hz Top-discharge Series

Outdoor unit Indoor unit


2 compressors,
1 circuit
Floor standing
type
8HP/10HP
8HP/10HP

2nd Generation
M.S.P duct type
8HP/10HP 12HP
(H.S.P duct type
customized) 12HP
3 compressors,
1 circuit
16HP
H.S.P duct type 20HP

Notes: 16HP 20HP


▲Cooling Only; ▲Cooling and heating
03. Features of Outdoor Unit
 Wide operation ambient temp. range
Tropical to 52°C
cooling 17℃ 46℃

heating -7℃ 24℃


03. Features of Outdoor Unit
 High efficient scroll compressor

Direct-drive, Hermetic , Scroll compressor

Well know brand compressor

Low noise design , Thermal protectors

Compact size and light weight, simple design


03. Features of Outdoor Unit
 Long piping length

Max. height drop


Max. equivalent
between IDU and
piping length
ODU.

50M 30M
03. Features of Outdoor Unit
 Easy installation

Simple piping and cabling


Compact cabinet design, saving installation area, easy transport.
Completely assembled, internally wired, charged refrigerant at the factory.
03. Features of Outdoor Unit
High reliability

High/low pressure switch Temperature sensor Current detector

Compressor oil heater


Self-diagnosis function
Phase fault protection
System current protection
High and low pressure switch protection
Temperature sensor malfunction alarm
04. Features of indoor unit
H.S.P duct type unit

8HP/10HP 16/20HP

Max external static pressure up to 196Pa


Long supply distance
Compact design, convenient installation
Flexible air duct design, for different room styles
Reserved fresh air intake port
3 fan speeds can be chosen :high ,medium and low
Galvanized steel drain pan is standard
Water pump, filter, wired controller ,heater is optional
04. Features of indoor unit
H.S.P duct type unit
Induct some
fresh Air

Long supply distance

Outtake Return air intake


Height ≤ 6.5 m

Max external static pressure up to 196Pa


Long supply distance
Supply air height up to 6.5M
Reserved fresh air intake port
04. Features of indoor unit
H.S.P duct type unit

Flexible air duct design, for different room styles.


04. Features of indoor unit
H.S.P duct type unit

Compact design, convenient installation.


04. Features of indoor unit
M.S.P duct type unit

1st Generation
8HP/10HP 12HP 16HP

2nd Generation
8HP/10HP 12HP

Compact design, convenient installation


Flexible air duct design, for different room styles
Reserved fresh air intake port
3 fan speeds can be chosen :high ,medium and low
Galvanized steel drain pan is standard
Water pump and air filter is optional
Water pump , filter, wired controller ,heater is optional
04. Features of indoor unit
M.S.P duct type unit

Convenient replace fan motor design, easy maintenance


(2nd general only)
04. Features of indoor unit
Floor standing type unit

8HP/10HP/12HP

Noble and elegant , beautiful and generous appearance


Auto swing louver , strong wind, long distance delivery
Touch screen control, wireless remote controller
Easy maintenance, washable air filter
Galvanized steel drain pan is standard
Heater is optional
04. Features of indoor unit
Floor standing type unit

Auto swing louver,strong wind, long distance delivery


04. Features of indoor unit
Floor standing type unit

Touch screen control, wireless remote controller


04. Features of indoor unit
Floor standing type unit

Easy maintenance, washable air filter


05. Installation and malfunction

Refrigerant circuit design

One refrigerant circuit


05. Installation and malfunction

Refrigerant circuit design

Two refrigerant circuits


05. Installation and malfunction

Refrigerant circuit design

Two refrigerant circuits


05. Installation and malfunction

Field wiring for duct type unit

One ODU drive one IDU


05. Installation and malfunction

Field wiring for duct type unit

Two ODUs drive one IDU


05. Installation and malfunction

Field wiring for floor standing type unit


05. Installation and malfunction

Duct type unit error code display


Infrared signal receiver Manual Switch

Operation lamp Timer lamp Alarm lamp

PRE-DEF lamp(cooling and heating type)


or fan only lamp(cooling only type)
Note:
OPT. Light: operation light; TME. Light: timer light;
DEF. Light: defrosting light; ☆: the light flashing.
05. Installation and malfunction

Duct type unit error code display


OPT. TME. DEF. ALARM
Type Remarks
Light Light Light Light
Manual
Room temp. sensor error - ☆ - -
reset
Manual
Evaporator temp. sensor error ☆ - - -
reset
Manual
Condenser temp. sensor error - - ☆ -
reset
Manual
Water pump temp. sensor error ☆ - - ☆
reset
The PRO terminal on PCB of indoor
Manual
unit without connected to grounding ☆ ☆ ☆ ☆
reset
wire
Manual
EEPROM error ☆ ☆ - -
reset
Manual
Condensing water level full error - - - ☆
reset
05. Installation and malfunction

Floor standing type unit error code display


05. Installation and malfunction

Floor standing type unit error code display

Type Code Remarks

EEPROM error E0 Manual reset


T1,Room temp. sensor error E1 Manual reset
T2,Evaporator temp. sensor error E2 Manual reset

Under heating mode, high P1 Auto reset


temperature protection.
Under cooling mode, low P2 Auto reset
temperature protection.
05. Installation and malfunction

Outdoor unit error code display

Type LED1 LED2 Remarks


Standby ☆ ☆ -
Cooling mode ◆ ◇ -
Heating mode ◆ ◆ -
Defrosting mode ◇ ◆ -
Phase sequence protection ◆ ●★ Manual reset

Communication failure ◆ ●●★ Manual reset

Outdoor condenser temp. sensor error ◆ ●●●★ Manual reset


Note:
☆: Light for 1 second, extinguish for 1 second;
●: Light for 0.4 second, extinguish for 0.4 second;
★: Light for 2 second, extinguish for 2 second. ◆: Light;
◇: Extinguish;
05. Installation and malfunction

Outdoor unit error code display

Type LED1 LED2 Remarks


Outdoor ambient temp. sensor error ◆ ●●●●★ Manual reset

Protection of low pressure ◇ ●★ Auto reset


Protection of high pressure ◇ ●●★ Auto reset
Protection of over-current ◇ ●●●★ Auto reset

Protection of condenser hi-temp. ◇ ●●●●★ Auto reset


Note:
☆: Light for 1 second, extinguish for 1 second;
●: Light for 0.4 second, extinguish for 0.4 second;
★: Light for 2 second, extinguish for 2 second. ◆: Light;
◇: Extinguish;
06. Control

Accessories

Name Type Usage


Remote controller R51/CE Control the system
Wired controller (optional) KJR-10B Control the system

Centralized controller (Optional) CCM03 Control the system

Network control module (Optional) MD-NIM01 Used with CCM03 to network


control the system
06. Control

Accessories

R51/CE KJR-10B CCM03 MD-NIM01


06. Control

Controller wiring diagram

Wired controller wiring diagram


06. Control

Controller wiring diagram

MD-NIM01 with CCM03 wiring diagram


Climate Solutions for
Green Environments!