Dr.

Fixit Pidicrete CF 151 M3


High Range Water reducing and retarding admixture
for concrete

Dr. Fixit Pidicrete CF 151 M3 is a superplasticising DOSAGE:

CONCRETE ADMIXTURES
admixture to produce pumpable or flowable concrete, Dosage range of Dr. Fixit Pidicrete CF 151 M3
free from bleeding and segregation when added to will be 250 ml to 750 ml per bag of cement.
the concrete mix having slump atleast 25 mm without
• Optimum dosage should be determined by doing
admixture.
site trial mixes. Dosage may go above maximum
It also imparts the cohesiveness to concrete mix for easy limit for High Performance Concrete and shall be
placing and pumping. determined by site trial mix.

SPECIFICATION : IS: 9103-1999 and ASTM-C-494- COMPATIBILITY:


86, Type G Dr. Fixit Pidicrete CF 151 M3 is compatible with
all types of cement e.g. OPC, PPC, PSC etc.
AREA OF APPLICATION: and Bridge bearing pad Dr. Fixit Pidicrete CF 151 M3 is compatible with all
equipment foundations air entraining agent which complies wiith IS 9103-
Ready Mix Concrete 2003 and Integral water proofing compound which
Piling Concrete complies with IS 2645- 1978. If other admixtures
are to be used in concrete containing Dr. Fixit
• Structural Concrete Pidicrete CF 151 M3 they must be dispensed
separately.
FEATURES & BENEFITS:
Water reduction upto 25% without effecting the SAFETY PRECAUTIONS :
workability Dr. Fixit Pidicrete CF 151 M3 is a non-toxic and
Helps in reducing cement content for a required inflammable. When in contact with the skin, it should
strength by reducing w/c ratio. be washed with cold water.
Increases workability at a given w/c ratio, resulting
easy placing, and eliminates honeycombing. TECHNICAL INFORMATION :

Dr. Fixit Pidicrete CF 151 M2


High workability for longer periods to allow long Appearance : Dark Brown Liquid
distance transport of concrete. Sp.Gravity : 1.200 +/- 0.02 at 30 °C
Reduction in shrinkage cracks Chloride content : Nil
Less permeable and hence more durable concrete. pH Value : 7.0 ± 1

METHOD OF APPLICATION: STORAGE :


Concrete shall be mixed with 50-70% of the mixing • Keep the liquid above freezing temperature.
water(based on mix design by weight). • If the product has frozen, thaw it at room
The correct quantity of Dr. Fixit Pidicrete CF 151 M3 temperature(25°C) and agitate to completely
should be measured with recommended dispenser reconstitute it in the original form.
and should be added to the concrete with remaining • Store under cover; protect from direct sunlight.
CC-DF-CF201RMC-FLR-ENG-04/07

30% mixing water and allow to mix it for recommended


mixing time. • Failure to comply with recommended storage
condition may result in premature deterioration of
Dr. Fixit Pidicrete CF 151 M3 should not be added the product and packaging.
in dry mixes under any circumstances

PACKING: Tanker load supply in litres/kgs, 265 kgs

Pidilite Industries Limited Disclaimer: The product information & application details given by the company & its agents
has been provided in good faith & meant to serve only as a general guideline during usage.
Construction Chemicals Division Users are advised to carry out tests & take trials to ensure on the suitability of products meeting
Ramkrishna Mandir Road Post Box No. 17411 their requirement prior to full scale usage of our products. Since the correct identification of
Andheri (E) Mumbai 400059 INDIA the problems, quality of other materials used and on-site workmanship are factors beyond
our control, there are no expressed or implied guarantee / warranty as to the results obtained.
Tel +91-22-2835 7000 Fax +91-22-2835 7008 The Company does not assume any liability or any consequential damage for unsatisfactory
website www.doctor-fixit.com E-mail drfixit@pidilite.com results, arising from the use of our products.