Pump
Product Catalog

Flowserve Corporation is one of the world’s leading providers of fluid


motion and control products and services. Operating in 56 countries,
the company produces engineered and industrial pumps, seals and
valves as well as a range of related flow management services.

Flowserve works closely with Heritage Names of Distinction


customers and partners to
deliver best-in-class solutions ACEC ™ Centrifugal Pumps
that leverage our considerable Aldrich ® Pumps
application experience, our
advanced technical services and Byron Jackson ® Pumps
our extensive product portfolio. Cameron ® Pumps
In this way, Flowserve provides
solutions that enable our Durco ® Pumps
customers to improve Flowserve ® Pumps
productivity, reliability
and profitability. IDP ® Pumps
Jeumont-Schneider ™ Pumps
Flowserve Pumps are comprised
of the brands listed at right. This Pacific® Pumps
is our heritage and the basis for
Pleuger ® Pumps
the respect and trust we enjoy in
the global marketplace. Scienco® Pumps
Sier-Bath ® Rotary Pumps
TKL™ Pumps
United ® Centrifugal Pumps
Western Land Roller ®
Irrigation Pumps
Wilson-Snyder ® Pumps
Worthington ® Pumps
Worthington Simpson ® Pumps

3
(FPD-100) Level 1.qxd 11/8/04 11:33 AM Page 4 Dan K. Snelson Clients:023-FLOWSERVE Pumps:023-Job Files:023-Open Jobs:0832-(FPD-100)

Table of Contents
Table of Contents

Section Page

Introduction 6-7

Flowserve Capabilities 8

A Guide to Flowserve Pumps 9


Overhung Pumps
Pump Selection Guide 10-16
Section Page

Introduction 17
Vertical Pumps
Chemical Process 18-23
Section Page
API Process 24-29
Introduction 51
Slurry & Solids Handling 30-34
Wet Pit - Radial,
Mixed and Axial Flow 52-53
General Industry 35-37
Double Case 54-55

Submersible Motor 56
Between Bearings Slurry and Solids Handling 57-59
Pumps
Sump 60-61
Section Page

Introduction 39

Single Case - Axially Split 40-42

Single Case - Radially Split 43-45

Double Case 46-48

4
(FPD-100) Level 1.qxd 11/8/04 11:33 AM Page 5 Dan K. Snelson Clients:023-FLOWSERVE Pumps:023-Job Files:023-Open Jobs:0832-(FPD-100)

Rotary Pumps

Table of Contents
Section Page

Introduction 63

Gear 64

Screw 65

Specialty Pumps Additional Information


Section Page Section Page

Introduction 71 Introduction 77

Nuclear 72-73 Reference Sources 78

Cryogenic 74 Global Engineered


Services and Support 79
Other 75
Training 80

Other Flowserve Products 81

Product Index 82
1K3x2V-7 35
Reciprocating Pumps 2K3x2V-10 35
2K4x3V-10 35
Section Page
2K3x2V-13 35
Introduction 67 2K4x3V-13/11* 35
2K6x4V-13 17
Reciprocating 68

5
(FPD-100) Level 1.qxd 11/8/04 11:33 AM Page 6 Dan K. Snelson Clients:023-FLOWSERVE Pumps:023-Job Files:023-Open Jobs:0832-(FPD-100)

Flowserve Pumps
Introduction
Introduction

Pump Supplier To The World

Flowserve is the driving force in the global industrial pump


marketplace. No other pump company in the world has the depth
or breadth of expertise in successful application of pre-engineered,
engineered and special purpose pumps and systems.

Tracing its history to 1790 and the earliest days of steam pumping
engines for municipal waterworks, Flowserve focuses on these
industrial sectors:

• Power generation
• Oil and gas production and transportation
• Hydrocarbon processing
• Chemical and petrochemical processing
• Water resources and desalination
• Mining and mineral processing
• Steel and primary metals
• Pulp and paper
• Nuclear
• General industry
• Specialty products
6
(FPD-100) Level 1.qxd 11/8/04 11:33 AM Page 7 Dan K. Snelson Clients:023-FLOWSERVE Pumps:023-Job Files:023-Open Jobs:0832-(FPD-100)

Pump Designs

Introduction
Flowserve pump product lines are extensive with more than 100
distinct models and thousands of optional configurations. These
are largely complementary pump types built to global standards
and customer specifications, including:

• Overhung process Optional configurations


• Between bearing axially split include:
• Between bearing radially split
• Sealed and sealless
• Vertical
• Volute and diffuser
• Submersible motor
• Close and long coupled
• Rotary
• Single and double casing
• Reciprocating
• Foot or frame mounted
• Nuclear
• Specialty

7
(FPD-100) Level 1.qxd 11/8/04 11:34 AM Page 8 Dan K. Snelson Clients:023-FLOWSERVE Pumps:023-Job Files:023-Open Jobs:0832-(FPD-100)

Flowserve
Capabilities
Flowserve Capabilities

Dynamic Technologies

Few, if any, pump companies can match the capabilities of Flowserve


in hydraulic and mechanical design or in materials engineering.
Among these capabilities are:

• Computational fluid dynamics


• Flow visualization
• Cavitation studies
• Efficiency optimization
• Finite element analysis
• Rapid prototyping
• Materials development,
processing and manufacturing

Market Focused Customer Support

Product and industry specialists develop effective proposals and


solutions directed toward market and customer preferences. They
offer technical advice and assistance throughout each stage of the
product life cycle, beginning with the inquiry. Benefits of a pumping
partnership with Flowserve include:

• Technology innovation
• Applications expertise
• Advanced engineering solutions
– Order engineering
– Hydraulic engineering
• Proven product reliability
• Worldwide service and support
• Competitive price and delivery

8
(FPD-100) Level 1.qxd 11/8/04 11:34 AM Page 9 Dan K. Snelson Clients:023-FLOWSERVE Pumps:023-Job Files:023-Open Jobs:0832-(FPD-100)

A Guide to
Flowserve Pumps

The purpose of this publication is to provide a brief summary of


the hundreds of pumps which comprise the Flowserve product line. Oil and Gas
Pump models are divided into six sections, beginning with
overhung pumps and continuing through specialty pumps.
(See Table of Contents, pp. 4-5 and Index pg. 82.)
Hydrocarbon Processing
Each pump is identified by its formal designation and accompanied
by a full-color cutaway illustration. Applicable engineering standards
are listed along with performance characteristics and key features.
The symbols shown at right are used to identify each pump’s Chemical

primary market applications.

For complete information about


Flowserve Pumps, visit: Power
www.flowserve.com

Nuclear

Water Resources

Mining

Pulp and Paper

Primary Metals

General Industry

9
(FPD-100) Level 1.qxd 11/8/04 11:34 AM Page 10 Dan K. Snelson Clients:023-FLOWSERVE Pumps:023-Job Files:023-Open Jobs:0832-(FPD-100)

Flowserve Pump
Selection Guide

10
(FPD-100) Level 1.qxd 11/8/04 11:37 AM Page 11 Dan K. Snelson Clients:023-FLOWSERVE Pumps:023-Job Files:023-Open Jobs:0832-(FPD-100)

11
(FPD-100) Level 1.qxd 11/8/04 11:37 AM Page 12 Dan K. Snelson Clients:023-FLOWSERVE Pumps:023-Job Files:023-Open Jobs:0832-(FPD-100)

Pump Selection
Guide

irc
Co ltur d A
Ag otiv try
m dus

n
ric e a

e
Au al In

u
r
ne

ns
to
Ge
Pump Selection Guide Pump Category Sub-Category Begins on page

Overhung Chemical Process 18 


API Process 24 
Slurry and Solids Handling 30 
General Industry 35 

Between Bearings Single Case - Axially Split 40 


Single Case - Radially Split 43 
Double Case 46

Vertical Wet Pit 52  


Double Case 54  
Submersible Motor 56  
Slurry and Solids Handling 57  
Sump 60  

Rotary Gear 64 


Screw 65 

Reciprocating 68  

Specialty Nuclear 72

Cryogenic 74 
Liquid Expander 74

Hydroturbine 75

Concrete Volute 75

12 Barge 75
Ge
ne
r








Au al In
to
m dus


Ag otiv try
ric e a
u n








Co ltur d A
ns e irc
ra


tru ft
Cr c
yo tion





ge
El nic
ec
tro
Fir nic
e s
Pr




o
(FPD-100) Level 1.qxd

Fo t
od ecti
Pr on
HV oc
AC ess



  
   
 

 
 


  

in
g
11/8/04

OE
M

W
at
11:37 AM

er






De Res
sa o
lin ur
Flo ati ces
od on


 


Gr Con
ou tro
n l





Se d W
wa ate
g r


Sn e C Dev
ow olle elo
m



 

ct
W a io pm
at king n a ent
er nd a












W Sup Tr nd I
at eat rrig
er ply
an m
Tr en atio
ea d t n
tm Di
en str
Ch t ib
ut
em io
n


ic
Ac al
id Pr
T oc


Ca rans ess
us fe in
ti r g


Ph c an
ar d
m Ch
Po ace lor
lym uti -Al
ca ka









Sl ers ls li
ur
ry
So Pro
lve ce
n ss
in
Vo ts
lat g
ile
W O
as rga
te n





 








   


Au Pro ic C
xil c o
iar ess mpo
y in
g un
ds
Page 13 Dan K. Snelson Clients:023-FLOWSERVE Pumps:023-Job Files:023-Open Jobs:0832-(FPD-100)
Hy
dr


oc
Bo arb
tto on
m



Ch s
ar
ge


(FPD-100) Level 1.qxd

De
co
k


Fir ing
e S
Pr yst








o t em
11/8/04

Of
fs ecti s
ite on


Po s an
we d
r W



 



Pr Re ast
oc co e
11:37 AM




es ve Pro
Sl s r y ce
ur Tra ss
ry ns in
g

 
a fe
Vo nd r
lat
ile Hea
Or vy
ga Oil
ni
Oi c
la Co
nd m





po
SA G un
GD s a ds
Pr


 Fir
e
Pr
od
uc
tio






LN te o n
G c t
Ex ion


NG pa
L nd
Ex er



Pi t a
pe ract nd C
lin ion ry



W ea a o
at nd nd gen
er B In ic





Cr and oos ject


ud te ion
e Brin r
e
In
jec
Po tio
we n




rG
Bo e
ile ne
r F ra






Bo ee tion
ile d
r


Co Fee
nd d B
e o





Co nsa ost
ol te e
in Ex r
Flu W rac g t
e a t
Ga ter ion


















Au s D
xil e
ia su






Nu ry S lfur
cle er iza
ar vic tion
Se es
rv
ice
Pr
im
a


Co ry M
ol
in etal
g








s
Page 14 Dan K. Snelson Clients:023-FLOWSERVE Pumps:023-Job Files:023-Open Jobs:0832-(FPD-100)
Nu
cle Ser riza
ar vic tion
Se es
rv
ice
Pr
im
a



Co ry M
ol
in eta




De g W ls
sc a





ali ter
Hy n g
dr
au



Pl lic
at
in Pre
g s







Sc , G s
(FPD-100) Level 1.qxd

ale alv
Re aniz
cy i
cle ng a
M nd
in Ot
11/8/04

in he
g







De rC
wa oa
tin





te gs
Le rin
ac g &
hi



11:37 AM

Pr ng Wat
im Ac e
ar id r S




Sl y P up
ro pl
ur
ry c y
Tr ess
an i
sf ng
er
Pu
lp
a
Bl nd
ea P
ch ape




Bo C h r
ile em
r ic

 
Ch Fee als
em d
i

 



Co cal
at and
in
 

Li
Di gs qu
ge or
st
e






Pa r
pe
r



Sh Sto
ow ck
er
Pu
m
ps

15
Pump Selection Guide
Page 15 Dan K. Snelson Clients:023-FLOWSERVE Pumps:023-Job Files:023-Open Jobs:0832-(FPD-100)
(FPD-100) Level 1.qxd 11/8/04 11:37 AM Page 16 Dan K. Snelson Clients:023-FLOWSERVE Pumps:023-Job Files:023-Open Jobs:0832-(FPD-100)
(FPD-100) Level 1.qxd 11/8/04 11:37 AM Page 17 Dan K. Snelson Clients:023-FLOWSERVE Pumps:023-Job Files:023-Open Jobs:0832-(FPD-100)

Overhung Pumps
Chemical Process
Mark 3 ANSI Standard 18
Mark 3 Lo-Flo 18
Mark 3 Unitized Self-Primer 18
Mark 3 Recessed Impeller 19
Mark 3 In-Line 19
Guardian Magnetic Drive 19

Overhung Pumps
CPX ISO Standard 20
CPXP Self-Primer 20
CPXR Recessed 20
CPXM Close Coupled 21
CPXV Chemical Sump 21
CPXS Magnetic Drive 21
PolyChem GRP Composite 22
PolyChem VGRP Composite
Sump 22
PolyChem S PFA Lined 22
PolyChem M Magnetic Drive 23
Polyshield Baseplate 23
Polybase Baseplate 23
API Process
HPX Centerline Mounted 24
HPXM Low Flow 24
PHL Centerline Mounted 24
PHL-Mag Magnetic Drive 25
ERPN Centerline Mounted 25
ERPN-Mag Magnetic Drive 25
HWX Vertical In-Line 26
HWM Low Flow In-Line 26
HWM2 Two Stage In-Line 26
WM Close Coupled In-Line 27
WM2 Two Stage In-Line 27
W Vertical In-Line 27
MSP Vertical In-Line 28
MSP2 Two Stage In-Line 28
DSVP Vertical In-Line 28
PVML Vertical In-Line 29
PVML-Mag Magnetic Drive 29
Power Monitor 29
Slurry and Solids Handling
M Hard Metal 30
MJ and MJC Sump 30
R Rubber Lined 30
RJ and RJC Rubber Lined 31
Titan Slurry Lined 31
Terra-Titan Sump 31
LC Chemical Slurry 32
MND Absorber Recirculation 32
MNR Absorber Recirculation 32
FRBH Paper Stock 33
FRBHJC Sump 33
Primo-Titan Self-Priming 33
MN Solids Handling 34
MF Solids Handling 34
MSX Submersible 34
General Industry
Drain-Titan Lined Sump 35
D800 Cast Iron 35
MEN and MEN-SP Water 35
F-Line Multistage 36
SMP Standard Motor 36
VSMP Vertical Std. Motor 36
SMX Non-Metallic Std. Mtr. 37
ECPJ Sump 37
ESP2 Sump 37 17
(FPD-100) Level 1.qxd 11/8/04 11:37 AM Page 18 Dan K. Snelson Clients:023-FLOWSERVE Pumps:023-Job Files:023-Open Jobs:0832-(FPD-100)

Mark 3 ANSI Standard Mark 3 Lo-Flo Mark 3 Unitized


Self-Primer
Overhung – Chemical Process

Standards Standards Standards


• ASME (ANSI) B73.1 • ASME (ANSI) B73.1 • Flowserve

Operating Parameters Operating Parameters Operating Parameters


• Flows to 1680 m3/h (7400 gpm) • Flows to 50 m3/h (220 gpm) • Flows to 320 m3/h (1400 gpm)
• Heads to 215 m (700 ft) • Heads to 300 m (1000 ft) • Heads to 120 m (400 ft)
• Pressures to 27 bar (400 psi) • Pressures to 30 bar (450 psi) • Pressures to 20 bar (285 psi)
• Temperatures from -75°C (-100°F) • Temperatures from -75°C (-100°F) • Temperatures to 370°C (700°F)
to 370°C (700°F) to 370°C (700°F) • Static suction lift to 6 m (20 ft)

Features Features Features


• Exclusive reverse vane impeller • Circular, concentric casing • Unitized casing with large priming
• Standard Mark 3A power end • Radial vane impeller chamber, air separator and volute
– External micrometer impeller • Mark 3A power end • Exclusive reverse vane impeller
adjustment – External micrometer impeller • Mark 3A power end
– Double row angular contact out- adjustment – External micrometer impeller
board bearings – Double row angular contact out- adjustment
– Single row, deep groove inboard board bearings – Double row angular contact out-
bearings – Single row, deep groove inboard board bearings
– Double lip oil seals bearings – Single row, deep groove inboard
– Constant level oiler – Double lip oil seals bearings
– Large, reflective sight glass – Constant level oiler – Double lip oil seals
• Choice of lubrication systems – Large, reflective sight glass – Constant level oiler
• Optional ANSI 3A power end with • Choice of lubrication systems – Large, reflective sight glass
lifetime warranty • Optional ANSI 3A power end with • Choice of lubrication systems
– Certified clean room assembly lifetime warranty • Optional ANSI 3A power end with
– Inpro/Seal’s VBXX isolators – Certified clean room assembly lifetime warranty
– Magnetic drain plug – Inpro/Seal’s VBXX isolators – Certified clean room assembly
• SealSentry™ seal chambers – Magnetic drain plug – Inpro/Seal’s VBXX isolators
• Largest shaft and bearing components • SealSentry seal chambers with – Magnetic drain plug
in standard ANSI pumps flow modifiers • Oversized shaft and bearing
• Oversized shaft and bearing components
Other Configurations components
• Mark 3 Lo-Flo Other Configurations
• Mark 3 unitized self-primer See Bulletin PS-10-13 • Mark 3 recessed impeller, self-primer
• Mark 3 recessed impeller
• Mark 3 Sealmatic dynamically sealed See Bulletin PS-10-13

18 See Bulletin PS-10-13


(FPD-100) Level 1.qxd 11/8/04 11:38 AM Page 19 Dan K. Snelson Clients:023-FLOWSERVE Pumps:023-Job Files:023-Open Jobs:0832-(FPD-100)

Mark 3 Recessed Mark 3 In-Line Guardian


Impeller Magnetic Drive

Overhung – Chemical Process


Standards Standards Standards
• Flowserve • ASME (ANSI) B73.2 • ASME (ANSI) B73.1 dimensions

Operating Parameters Operating Parameters Operating Parameters


• Flows to 455 m3/h (2000 gpm) • Flows to 370 m3/h (1630 gpm) • Flows to 375 m3/h (1650 gpm)
• Heads to 120 m (400 ft) • Heads to 230 m (760 ft) • Heads to 215 m (705 ft)
• Pressures to 20 bar (285 psi) • Pressures to 24 bar (350 psi) • Pressures to 24 bar (350 psi)
• Temperatures from -75°C (-100°F) • Temperatures from -75°C (-100°F) • Temperatures from -75°C (-100°F)
to 370°C (700°F) to 370°C (700°F) to 290°C (550°F)

Features Features Features


• Low shear vortex pumping action • Exclusive reverse vane impeller • Magnetic drive design
• Fractional media contact with • Mark 3A power end • Alloy C-276 containment shell
the impeller – External micrometer impeller • Rare earth magnets
• Thick-wall wet end components adjustment • Low NPSHR, reverse vane impeller
suitable for light slurries – Double row angular contact out- • Casings and impellers interchangeable
• Mark 3A power end board bearings with sealed configuration
– External micrometer impeller – Single row, deep groove inboard • Optimized internal lubrication path
adjustment bearings • Silicon carbide bushings and journals
– Double row angular contact out- – Double lip oil seals with double spiral grooves
board bearings • Optional ANSI 3A power end with • Standard and contained back pullout
– Single row, deep groove inboard lifetime warranty • Configurations
bearings – Certified clean room assembly – G-Series (-75°C [-100°F] to 120°C
– Double lip oil seals – Inpro/Seal’s VBXX isolators [250°F])
– Constant level oiler • SealSentry seal chambers – H-Series (-120°C [-250°F] to 290°C
– Large, reflective sight glass • Unique C-plus motor and pump shaft [550°F])
• Optional ANSI 3A power end with alignment system • Options
lifetime warranty • Choice of bearing lubrication – Fiber-optic leak detection
– Certified clean room assembly – Regreasable bearings – Containment shell temperature
– Inpro/Seal’s VBXX isolators – Oil mist probes
– Magnetic drain plug – Permanently lubricated bearings – Process temperature probes
• SealSentry seal chambers – External flush plans
• Oversized shaft and bearing Other Configurations
• Mark 3 in-line, recessed impeller See Bulletin P-10-14
Other Configurations
• Mark 3 ANSI standard See Bulletin PS-10-15
• Mark 3 Sealmatic recessed impeller

See Bulletin PS-10-13 19


(FPD-100) Level 1.qxd 11/8/04 11:38 AM Page 20 Dan K. Snelson Clients:023-FLOWSERVE Pumps:023-Job Files:023-Open Jobs:0832-(FPD-100)

CPX ISO Standard CPXP Self-Primer CPXR Recessed Impeller


Overhung – Chemical Process

Standards Standards Standards


• ISO 2858 • ISO 2858 • ISO 2858
• ISO 5199 • ISO 5199 • ISO 5199

Operating Parameters Operating Parameters Operating Parameters


• Flows to 1400 m3/h (6160 gpm) • Flows to 250 m3/h (1100 gpm) • Flows to 750 m3/h (3300 gpm)
• Heads to 250 m (820 ft) • Heads to 130 m (425 ft) • Heads to 100 m (330 ft)
• Pressures to 25 bar (365 psi) • Pressures to 25 bar (365 psi) • Pressures to 25 bar (365 psi)
• Temperatures from -80°C (-110°F) • Temperatures from -80°C (-110°F) • Temperatures from -80°C (-110°F)
to 350°C (660°F) to 350°C (660°F) to 350°C (660°F)

Features Features Features


• 45° conically shaped seal chamber • Reflux priming principle • Vortex action
with integral flow modifiers • One-piece casing with large priming • Semi-open recessed impeller with
• External impeller adjustment chamber, air separator and volute wide font clearance provides
• High efficiency, low NPSHR, precision • 45° conically shaped seal chamber low-shear pumping
cast semi-open impeller with integral flow modifiers • 45° conically shaped seal chamber
• Less than 0.05 mm (0.002 in) • External impeller adjustment with integral flow modifiers
deflection at the seal face • High efficiency, low NPSHR, precision • Standard non-contacting labyrinth
• Accepts multiple seal arrangements cast semi-open impeller seals
• Standard non-contacting labyrinth seal • Accepts multiple seals • Less than 0.05 mm (0.002 in)
• Back pull-out design • Suction run-dry capability deflection at the seal face
• Double row, angular contact thrust • Standard non-contacting labyrinth seal • External impeller adjustment
bearings standard • Back pull-out design • Back pull-out design
– Duplex, back-to-back angular • Double row, angular contact thrust • Double row, angular contact
contact thrust bearing optional bearings standard thrust bearings standard
• CE marked and compliant with – Duplex, back-to-back angular – Duplex, back-to-back angular
applicable European directives, contact thrust bearing optional contact thrust bearing optional
such as ATEX • CE marked and compliant with • CE marked and compliant with
applicable European directives, applicable European directives,
Other Configurations such as ATEX such as ATEX
• Low flow, high head design
• CPXM close coupled Other Configurations Other Configurations
• CPXP self-primer • CPXPM close coupled, self-primer • CPXVR recessed impeller sump
• CPXR recessed impeller • CPXPS magnetic drive, self-primer • CPXRM close coupled,
• CPXV chemical sump • CPXPSM close-coupled magnetic recessed impeller
• CPXN centerline mounted drive self-primer
See Bulletin PS-10-30
20 See Bulletin PS-10-30 See Bulletin PS-10-30
(FPD-100) Level 1.qxd 11/8/04 11:41 AM Page 21 Dan K. Snelson Clients:023-FLOWSERVE Pumps:023-Job Files:023-Open Jobs:0832-(FPD-100)

CPXM Close Coupled CPXV Chemical Sump CPXS Magnetic Drive

Overhung – Chemical Process


Standards Standards Standards
• ISO 2858 • API 610, 8th edition • ISO 2858
• ISO 5199 • ISO 5199 • ISO 5199

Operating Parameters Operating Parameters Operating Parameters


• Flows to 570 m3/h (2500 gpm) • Flows to 1400 m3/h (6160 gpm) • Flows to 420 m3/h (1850 gpm)
• Heads to 125 m (400 ft) • Heads to 250 m (820 ft) • Heads to 160 m (525 ft)
• Pressures to 25 bar (365 psi) • Pressures to 25 bar (365 psi) • Pressures to 25 bar (365 psi)
• Temperatures from -20°C (-5°F) • Temperatures from -40°C (-40°F) • Temperatures from -40°C (-40°F)
to 160°C (320°F) to 350°C (660°F) to 250°C (480°F)
• Speeds to 4700 rpm • Discharge sizes to 100 mm (4 in)
Features
• Compact, space-saving configuration Features Features
• 45° conically shaped seal chamber • Heavy-duty casing with multi-ribbed • Reinforced PEEK or Alloy C-276
with integral flow modifiers discharge flange primary containment shell
• External impeller adjustment • High efficiency, low NPSHR, precision • Secondary containment shell optional
• High efficiency, low NPSHR, precision cast semi-open impeller • High performance rare earth magnets
cast semi-open impeller • Column lengths to 10 m (33 ft) • Low NPSHR open impeller
• Less than 0.05 mm (0.002 in) • Heavy-duty, sealed for life, double • Advanced sintered silicon carbide
deflection at the seal face thrust bearings bushings and journal bearings
• Radiating surfaces • Options • Standard and contained back
• Accepts multiple seals – Spacer or flexible coupling pull-out design
• Optional secondary seal – Rectangular or circular soleplates • Non-contacting labyrinth seals
• Standard non-contacting labyrinth seal – Jacketed body • CE marked and compliant with
• Back pull-out design – Recessed impeller applicable European directives,
• CE marked and compliant with – Oil lubrication such as ATEX
applicable European directives – Non-spacer coupling
such as ATEX – Suction strainer Other Configurations
• CE marked and compliant with • CPXSM ISO close coupled,
Other Configurations applicable European directives, magnetic drive
• CPXPM close coupled, self-primer such as ATEX • CPXPSM ISO close coupled,
• CPXSM close coupled, magnetic drive magnetic drive, self-primer
• CPXRM close coupled, Other Configurations
recessed impeller • CPXVR recessed impeller sump See Bulletin PS-10-30

See Bulletin PS-10-30 See Bulletin PS-10-30

21
(FPD-100) Level 1.qxd 11/8/04 11:41 AM Page 22 Dan K. Snelson Clients:023-FLOWSERVE Pumps:023-Job Files:023-Open Jobs:0832-(FPD-100)

PolyChem GRP Engineered PolyChem VGRP Engineered PolyChem S-Series


Polymer Composite Polymer Composite Sump Fluoropolymer Lined
Overhung – Chemical Process

Standards Standards Standards


• ASME (ANSI) B73.5 • Flowserve • ASME (ANSI) B73.1
• ISO 2858
Operating Parameters Operating Parameters • JIS drilling
• Flows to 2050 m3/h (9000 gpm) • Flows to 565 m3/h (2500 gpm)
• Heads to 150 m (500 ft) • Heads to 110 m (350 ft) Operating Parameters
• Pressures to 17 bar (250 psi) • Pressures to 17 bar (250 psi) • Flows to 420 m3/h (1860 gpm)
• Temperatures from -45°C (-50°F) • Temperatures from -30°C (-20°F) • Heads to 145 m (480 ft)
to 120°C (250°F) to 90°C (200°F) • Pressures to 17 bar (250 psi)
• Temperatures from -30°C (-20°F)
Features Features to 150°C (300°F)
• Glass reinforced vinyl ester • Glass reinforced vinyl ester
• Unitized casing with integrally • Unitized casing with integrally Features
molded, fully gusseted suction and molded, fully gusseted suction and • PFA lined wet end
discharge flanges discharge flanges • Metal armor meets material
• Tapered polygon impeller drive • Externally adjustable, semi-open specifications of ASTM A395
• Stuffing box accommodates multiple impeller and GGG 40.3
seals, glands and flush arrangements • Shaft and bearing system operates • Standard Mark 3A power end
• Standard Mark 3A power end well below the first critical speed • SealSentry seal chamber
– External micrometer impeller • Self-lubricated or external flush • Accommodates multiple seal types
adjustment bearings • Shaft options
– Double row angular contact out- • Single-piece, lightweight, filament- – Standard silicon carbide shaft sleeve
board bearings wound, reinforced fiberglass – Alloy shaft sleeves
– Single row, deep groove inboard composite column – Solid shafts
bearings • Single and duplex configurations • Bearing housing options
– Double lip oil seals • Full basket strainer – Labyrinth oil seals
– Constant level oiler • NEMA in-line motor – Oil slinger
• Optional ANSI 3A power end with • Fiberglass mounting plate – Regreasable or double
lifetime warranty • Tapered polygon impeller drive shielded bearings
– Certified clean room assembly • Pull-out bearing retainers – Oil mist lubrication
– Inpro/Seal’s VBXX isolators • Level controls • Optional ANSI 3A power end with
– Magnetic drain plug • Choice of shaft metallurgy lifetime warranty
– Certified clean room assembly
Other Configurations Other Configurations – Inpro/Seal’s VBXX isolators
• VGRP engineered polymer • GRP engineered polymer composite – Magnetic drain plug
composite sump
• Self-primer See Bulletin PS-10-17 See Bulletin PS-10-17

22 See Bulletin PS-10-17


(FPD-100) Level 1.qxd 11/8/04 11:41 AM Page 23 Dan K. Snelson Clients:023-FLOWSERVE Pumps:023-Job Files:023-Open Jobs:0832-(FPD-100)

PolyChem M-Series Polyshield Baseplate and Polybase Polymer


Fluoropolymer Lined, Foundation System Concrete Baseplate
Magnetic Drive

Overhung – Chemical Process


Standards Standards Standards
• ASME (ANSI) B73.1 • Flowserve • ANSI and ISO standard designs
• ISO 2858
• JIS drilling Operating Parameters Features
• Temperatures to 260°C (500°F) • Solid polymer concrete construction
Operating Parameters • Low installed cost
• Flows to 135 m3/h (600 gpm) Features • Superior flatness
• Heads to 145 m (480 ft) • Combines non-metallic baseplate • Enhanced vibration dampening
• Pressures to 17 bar (250 psi) and formed concrete foundation for • Excellent corrosion resistance
• Temperatures from -30°C (-20°F) pump-driver in one complete unit • Outstanding resistance to twisting
to 150°C (300°F) • Excellent corrosion resistance or diaphragming
• Improved vibration dampening • 8-point™ adjuster alignment system
Features • Reduced installation costs and time • Options
• PFA lined wet end • Solid one-piece polymer motor – Polyboc™ motor mounting blocks
• Casing is ductile cast iron with mounting block with four 304 SS – Catch basins
3 mm (0.1 in) minimum PFA liner transverse motor block adjusters – Grout holes
thickness • Self-venting design with grout hole – Alternate equipment inserts
• PFA lined fiberglass containment shell and plug
• Enclosed PFA lined impeller • Standard 316 SS inserts See Bulletin PS-10-13
• Rare earth magnets in • Integral catch basin with NPT
synchronous drive connection
• Metal armor meets material • Uses 200 bar (3000 psi) concrete
specifications of ASTM A395 and • Suitable with ANSI, ISO, API and
GGG40.3 other foot-mounted and centerline
• Separate inner magnet and impeller mounted pumps
components • Outstanding flatness
• Rotating shaft design • Options
• Silicon carbide radial and axial – Choice of three polymer materials
thrust bearings – Alloy 20 and Alloy C-276
• Choice of bearing lubrication inserts available
• Options – CPVC drain connection
– Long and close coupled
– Open impeller See Bulletin PS-90-2
– ANSI 3A power end

See Bulletin PS-10-17

23
(FPD-100) Level 1.qxd 11/8/04 11:41 AM Page 24 Dan K. Snelson Clients:023-FLOWSERVE Pumps:023-Job Files:023-Open Jobs:0832-(FPD-100)

HPX (OH2) HPXM (OH2) PHL (OH2)


Centerline Mounted Centerline Mounted, Centerline Mounted
Low Flow
Overhung – API Process

Standards Standards Standards


• API 610 (OH2), latest edition • API 610 (OH2), latest edition • API 610 (OH2), latest edition

Operating Parameters Operating Parameters Operating Parameters


• Flows to 2000 m3/h (9000 gpm) • Flows to 30 m3/h (130 gpm) • Flows to 900 m3/h (4000 gpm)
• Heads to 350 m (1100 ft) • Heads to 215 m (700 ft) • Heads to 400 m (1300 ft)
• Pressures to 80 bar (1160 psi) • Pressures to 80 bar (1160 psi) • Pressures to 40 bar (600 psi)
• Temperatures from -160°C (-250°F) • Temperatures from -160°C (-250°F) • Temperatures to 450°C (840°F)
to 450°C (840°F) to 450°C (840°F) • Motor sizes to 110 kW (150 hp)

Features Features Features


• Centerline supported casing • Low flow, high head design • Centerline supported casing
• Nozzle loading capability beyond • Replaceable volute inserts • Custom-tuned hydraulics
API 610 design requirements • High efficiency patented design radial • State-of-the-art diffuser technology
• Dynamically balanced impeller blade impeller – Project-specific designs
• Rugged shaft design • Full interchangeability with HPX bearing • Low shaft deflection at any flow
• API 682 seal chamber accommodates assembly and mechanical seals • API 682 seal chamber accommodates
multiple seal types • Choice of bearings multiple seal types
• Choice of bearings – Standard single row, deep groove, • Bearing housing cooling options
– Standard single row, deep groove, radial bearing and duplex, single row – Air fan
radial bearing and duplex, single row 40° angular contact thrust bearings – Water jacket
40° angular contact thrust bearings – Special bearing arrangements for • Replaceable diffusers
– Special bearing arrangements for high suction pressures
high suction pressures • Bearing lubrication and cooling Other Configurations
• Bearing lubrication and cooling options • Top suction nozzle
options – Oil mist and oil purge • PHL-Mag centerline mounted,
– Oil mist and oil purge – Fan cooling magnetic drive
– Fan cooling – Finned cooling insert
– Finned cooling insert • Optional inducer See Bulletin PSS-10-5.2
• Options
– Top suction nozzle Other Configurations
– Inducer • HPX centerline mounted

Other Configurations See Bulletin PSS-10-5.1


• HPXM centerline mounted, low flow

See Bulletin PS-10-5

24
(FPD-100) Level 1.qxd 11/8/04 11:42 AM Page 25 Dan K. Snelson Clients:023-FLOWSERVE Pumps:023-Job Files:023-Open Jobs:0832-(FPD-100)

PHL-Mag ERPN ERPN-Mag


Centerline Mounted, Centerline Mounted Centerline Mounted,
Magnetic Drive Magnetic Drive

Overhung – API Process


Standards Standards Standards
• API 685, latest edition • Flowserve • Flowserve
• API 682 seal chamber • ASME (ANSI) B16.5 flanges
Operating Parameters
• Flows to 900 m3/h (4000 gpm) Operating Parameters Operating Parameters
• Heads to 400 m (1300 ft) • Flows to 1100 m3/h (4800 gpm) • Flows to 1100 m3/h (4800 gpm)
• Pressures to 40 bar (600 psi) • Heads to 230 m (750 ft) • Heads to 230 m (750 ft)
• Temperatures to 200°C (400°F) • Pressures to 60 bar (850 psi) • Working pressures to 60 bar (850 psi)
• Motor sizes to 130 kW (175 hp) • Temperatures to 350°C (660°F) • Suction pressures to 50 bar (750 psi)
• Temperatures to 350°C (660°F)
Features Features
• Magnetic drive design • Critical parameters meet API 610 Features
• 100% leak-free sealless design – Vibration limits • Magnetic drive design
• Custom-tuned hydraulics – Deflection limits at seal faces • Critical parameters meet API 685
• State-of-the-art diffuser technology – Nozzle loading capabilities – Vibration limits
– Project-specific designs – Balancing grades – Nozzle loading capabilities
• Alloy C-276 containment shell • API 682 seal chamber accommodates – Balancing grades
hydrotested to 60 bar (900 psi) multiple seal types • Dynamically balanced, high efficiency
• Product lubricated silicon carbide • Dynamically balanced, high semi-open impeller
bearings efficiency impeller • Casing and cover with metal-to-metal
• Replaceable diffusers • Centerline supported casing fit and fully confined, controlled
• Double volute design for discharge compression gasket
Other Configurations flanges 80 mm (3 in) and larger • Standard roller type radial bearing
• Top suction nozzle • Renewable wear rings for casing • Duplex, single row 40° angular contact
• PHL centerline mounted and cover back-to-back mounted thrust bearings
• Back pull-out design • Renewable wear rings
See Bulletin PSS-10-5.2 • Options • ASME B16.5 Class 300 RF standard;
– Non-clogging recessed impeller Class 600 RF flanges optional
– ERPN-O semi-open impeller • Standard temperature probe
– Inducer • Pressure switch
– Choice of API materials • Options
– Secondary containment
Other Configurations – Inducer
• ERPN-Mag centerline mounted, – Choice of API materials
magnetic drive
Other Configurations
See Bulletin PS-10-20 • ERPN centerline mounted

See Bulletin PS-10-20 25


(FPD-100) Level 1.qxd 11/8/04 11:42 AM Page 26 Dan K. Snelson Clients:023-FLOWSERVE Pumps:023-Job Files:023-Open Jobs:0832-(FPD-100)

HWX (OH3) HWM (OH3) HWM2 (OH3)


Vertical In-Line Vertical In-Line, Vertical In-Line, Low Flow,
Low Flow Two Stage
Overhung – API Process

Standards Standards Standards


• API 610 (OH3), latest edition • API 610 (OH3), latest edition • API 610 (OH3), latest edition

Operating Parameters Operating Parameters Operating Parameters


• Flows to 1500 m3/h (6600 gpm) • Flows to 30 m3/h (130 gpm) • Flows to 30 m3/h (130 gpm)
• Heads to 300 m (1000 ft) • Heads to 220 m (725 ft) • Heads to 440 m (1450 ft)
• Pressures to 80 bar (1160 psi) • Pressures to 50 bar (750 psi) • Pressures to 60 bar (850 psi)
• Temperatures from -160°C (-250°F) • Temperatures from -185°C (-300°F) • Temperatures from -185°C (-300°F)
to 400°C (750°F) to 400°C (750°F) to 400°C (750°F)

Features Features Features


• Space saving design • Low flow, high head design • Low flow, high head design
• API 682 seal chamber accommodates • Patented modular design • Patented modular design
multiple seal types • More than 100 BEP fits • More than 100 BEP fits
• Stiff shaft design in one pump size in one pump size
– Limits maximum deflection at • Replaceable volute inserts • Replaceable volute inserts
seal faces to 0.05 mm (0.002 in) • Patented radial blade impeller • Patented radial blade impeller
– Superior shaft stiffness • Space saving design • Space saving design
factors (L3/D4) • API 682 seal chamber accommodates • API 682 seal chamber accommodates
• Dynamically balanced impeller multiple seal types multiple seal types
• Motor support head accommodates • Dynamically balanced impeller • Dynamically balanced impeller
NEMA, IEC, C-face and P-base • Motor support head accommodates • Motor support head accommodates
field drivers NEMA, IEC, C-face and P-base NEMA, IEC, C-face and P-base
• Bearing lubrication options field drivers field drivers
– Oil cascade (patented) • Bearing lubrication options • Bearing lubrication options
– Oil mist – Oil cascade (patented) – Oil cascade (patented)
– Grease lube – Oil mist – Oil mist
• Options – Grease lube – Grease lube
– Inpro top bearing isolator • Options • Options
– Inducer – Inpro top bearing isolator – Inpro top bearing isolator
– Double suction impeller – Inducer – Inducer

Other Configurations Other Configurations Other Configurations


• HWM vertical in-line, low flow • HWM2 vertical in-line, low flow, • HWM vertical in-line, low flow
• HWM2 vertical in-line, low flow, two stage • HWX vertical in-line
two stage • HWX vertical in-line
See Bulletin PS-10-25
See Bulletin PS-10-27 See Bulletin PS-10-25
26
(FPD-100) Level 1.qxd 11/8/04 11:42 AM Page 27 Dan K. Snelson Clients:023-FLOWSERVE Pumps:023-Job Files:023-Open Jobs:0832-(FPD-100)

WM (OH5) WM2 (OH5) W (OH4)


Close Coupled, Vertical Close Coupled, Vertical In-Line
In-Line, Low Flow Vertical In-Line, Low Flow,
Two Stage

Overhung – API Process


Standards Standards Standards
• API 610 (OH5), latest edition • API 610 (OH5), latest edition • API 610 (OH4), latest edition

Operating Parameters Operating Parameters Operating Parameters


• Flows to 30 m3/h (130 gpm) • Flows to 30 m3/h (130 gpm) • Flows to 1500 m3/h (6600 gpm)
• Heads to 220 m (725 ft) • Heads to 440 m (1450 ft) • Heads to 300 m (1000 ft)
• Pressures to 50 bar (750 psi) • Pressures to 60 bar (850 psi) • Pressures to 80 bar (1160 psi)
• Temperatures from -45°C (-50°F) to • Temperatures from -45°C (-50°F) to • Temperatures from -160°C (-250°F)
260°C (500°F) 260°C (500°F) to 400°C (750°F)

Features Features Features


• Close coupled design • Close coupled design • Space saving design
• Low flow, high head design • Low flow, high head design • API 682 seal chamber
• Patented modular design • Patented modular design • Back pull-out design
• More than 100 BEP fits in one • More than 100 BEP fits in one • Stiff shaft design
pump size pump size – Limits maximum deflection at
• Less than 0.05 mm (0.002 in) • Less than 0.05 mm (0.002 in) seal faces to 0.05 mm (0.002 in)
maximum deflection at seal faces maximum deflection at seal faces – Superior shaft stiffness
• Replaceable volute inserts • Replaceable volute inserts factors (L3/D4)
• Patented radial blade impeller • Patented radial blade impeller • Dynamically balanced impeller
• Continuously rising performance • Continuously rising performance • Renewable casing and impeller rings
curve with low flow stability curve with low flow stability • Motor support head accommodates
• API 682 seal chamber accommodates • API 682 seal chamber accommodates NEMA, IEC, C-face and P-base
multiple seal types multiple seal types field drivers
• Motor support head accommodates • Motor support head accommodates • Rigid spacer-type coupling
NEMA, IEC, C-face and P-base NEMA, IEC, C-face and P-base • Steel coupling guard
field drivers field drivers
• Dynamically balanced impeller • Dynamically balanced impeller Other Configurations
• Options • Options • HWX vertical in-line
– Inpro top bearing isolator – Inpro top bearing isolator • HWM vertical in-line, low flow
– Inducer – Inducer • HWM2 vertical in-line, low flow,
two stage
Other Configurations Other Configurations
• WM2 close coupled, vertical in-line, • WM close coupled, vertical in-line, See Bulletin PS-10-27
low flow, two stage low flow
• HWM vertical in-line, low flow • HWM vertical in-line, low flow

See Bulletin PS-10-25 See Bulletin PS-10-25


27
(FPD-100) Level 1.qxd 11/8/04 11:42 AM Page 28 Dan K. Snelson Clients:023-FLOWSERVE Pumps:023-Job Files:023-Open Jobs:0832-(FPD-100)

MSP Vertical In-Line, MSP2 Vertical In-Line, DSVP (OH4)


Medium Speed Medium Speed, Vertical In-Line
Two Stage
Overhung – API Process

Standards Standards Standards


• Flowserve • Flowserve • API 610 (OH4), latest edition

Operating Parameters Operating Parameters Operating Parameters


• Flows to 27 m3/h (120 gpm) • Flows to 25 m3/h (110 gpm) • Flows to 3400 m3/h (15 000 gpm)
• Heads to 600 m (1970 ft) • Heads to 900 m (2955 ft) • Heads to 85 m (275 ft)
• Pressures to 100 bar (1450 psi) • Pressures to 100 bar (1450 psi) • Pressures to 40 bar (600 psi)
• Maximum suction pressure to • Maximum suction pressure to • Temperatures to 340°C (650°F)
40 bar (580 psi) 10 bar (150 psi) • Motor ratings to 895 kW (1200 hp)
• Temperatures from -40°C (-40°F) • Temperatures from -40°C (-40°F)
to 350°C (660°F) to 200°C (390°F) Features
• Speeds from 2000 rpm to 8000 rpm • Space-saving design
Features • API 682 seal chamber accommodates
Features • Closely following API 610, multiple seal types
• Closely following API 610, 8th edition • Double suction enclosed impeller
8th edition • Two stage opposed impeller • Double volute case design
• Modified concentric volute configuration • Standard case wear rings
• Open impeller with balance holes • Modified concentric volute • Optional impeller wear rings
and scallops • Open impeller with balance holes • Metal-to-metal case to cover
• Variable frequency drive and scallops sealing with confined gasket
• Rigid coupling • Variable frequency drive • Rigid spacer type coupling
• Single or dual cartridge mechanical • Rigid coupling • Impeller nut design, threaded
seals • Single or dual cartridge mechanical to tighten with rotation
• Options seals
– Inducer • Options
– Choice of materials – Inducer
– Choice of materials
Other Configurations
• Horizontal configuration Other Configurations
• MSP2 vertical in-line, medium • MSP vertical in-line, medium speed
speed, two stage
See Bulletin PS-10-1
See Bulletin PS-10-1

28
(FPD-100) Level 1.qxd 11/8/04 11:42 AM Page 29 Dan K. Snelson Clients:023-FLOWSERVE Pumps:023-Job Files:023-Open Jobs:0832-(FPD-100)

PVML (OH5) PVML-Mag Vertical Pump Power


Vertical In-Line In-Line, Magnetic Drive Monitor

Overhung – API Process


Standards Standards Standards
• API 610 (OH5), latest edition • API 685, latest edition • Flowserve
• BS 4082R
Operating Parameters Features
Operating Parameters • Flows to 500 m3/h (2200 gpm) • Monitors and displays power to
• Flows to 500 m3/h (2200 gpm) • Heads to 275 m (900 ft) the pump
• Heads to 275 m (900 ft) • Pressures to 40 bar (600 psi) • Protects pump from underload and
• Pressures to 40 bar (600 psi) • Temperatures to 200°C (400°F) overload operating conditions
• Temperatures to 250°C (480°F) • Eliminates costly downtime and
Features expensive pump repairs caused by:
Features • Permanent magnetic drive design – Dry running
• Space-saving, alignment-free design • 100% leak-free sealless operation – Pump overloads
• Custom-tuned hydraulics • Contamination-free pumpage – Cavitation
• State-of-the-art diffuser technology without use of external fluid – Blocked lines
– Project-specific designs • Custom tuned hydraulics – Closed suction or discharge valves
• API 682 seal chamber accommodates • State-of-the-art diffuser technology – Excessive wear or rubbing
multiple seal types – Project-specific designs • Works on all pumps having steady
• Dynamically balanced impeller • Dynamically balanced impeller (non-pulsating) loads
• Positively locked, anti-rotation • Product lubricated silicon carbide – Centrifugal, gear or turbine
impeller nut with threads unexposed radial and axial thrust slide bearings – ANSI, API or ISO
to pumped fluid • Patented venting of slide bearings – Sealed or sealless
area • Push button display of horsepower
Other Configurations • Positively locked, anti-rotation or kilowatts
• PVML-Mag vertical in-line, impeller nut with threads unexposed • Adjustable low power and high power
magnetic drive to pumped fluid set points
• Adjustable trip delay timers
See Bulletin PS-10-28 Other Configurations
• Adjustable start-up delay timer for self-
• PVML vertical in-line
priming applications
• 4 to 20 milliamp analog output facilitates
See Bulletin PS-10-28
remote displays, operator interface and
output to PLC or DCS
• Two form C relay outputs for low and
high power trips
• Automatic, manual and remote
reset options

See Bulletin PM-1

29
(FPD-100) Level 1.qxd 11/8/04 11:42 AM Page 30 Dan K. Snelson Clients:023-FLOWSERVE Pumps:023-Job Files:023-Open Jobs:0832-(FPD-100)

M Hard Metal, MJ and MJC Hard Metal R Horizontally Split,


Abrasive Slurry Slurry Sump Rubber Lined Slurry
Overhung – Slurry and Solids Handling

Standards Standards Standards


• Flowserve • Flowserve • Flowserve

Operating Parameters Operating Parameters Operating Parameters


• Flows to 10 000 m3/h (44 000 gpm) • Flows to 225 m3/h (1000 gpm) • Flows to 10 000 m3/h (44 000 gpm)
• Heads to 90 m (300 ft) • Heads to 30 m (100 ft) • Heads to 50 m (160 ft)
• Pressures to 10 bar (150 psi) • Pressures to 10 bar (150 psi) • Pressures to 10 bar (150 psi) stan-
• Temperatures to 120°C (250°F) • Temperatures to 110°C (225°F) dard; 35 bar (500 psi) optional
• Solids from 2% to 70% by weight • Solids from 2% to 70% by weight • Temperatures to 110°C (225°F)
• Speeds to 1780 rpm • Solids from 2% to 70% by weight
Features
• One-piece high chrome iron, Features Features
concentric casing with replaceable • MJ - Submerged bearing and lineshaft • Concentric, cast iron casing with
gland and suction side wear plates design for deep setting replaceable, abrasion resistant
• Closed impeller with pump-out vanes • MJC - Cantilever design with no rubber liner
on front and rear shroud submerged bearings • Rubber lined, closed impeller with
• Standard packing-type stuffing box • Abrasion and corrosion resistant high front and rear pump-out vanes
with replaceable wear plate chrome iron concentric casing • Standard packing type stuffing box
– Full and low flow flush connections • Integrally cast straightening vanes with replaceable wear plate
– Optional 316 SS, Alloy 20 or duplex in the suction nozzle – Full and low flow flush connections
stainless steel • Closed impeller with pump-out vanes – Optional 316 SS, Alloy 20, or Alloy
• Heavy-duty bearing frame on front and rear shrouds C-276 materials
designed for V-belt loads • MJ has fluted “Cutlass” rubber • Heavy-duty bearing frame
• Cartridge style bearings bearings • Three-point external end clearance
• Parts interchangeable with R pump • MJC has “Thordon” restriction adjustment
• Three-point external end bushing • Parts interchangeable with M pump
clearance adjustment • Directly coupled or V-belt driven • Directly coupled or V-belt driven
• Options • Options • Options
– Vortex semi-recessed impeller – Hard metal expeller – Acid-resistant stuffing box kits
– Hard metal expeller – Open and recessed impellers – Hard metal expeller
– Mechanical seal housing – Choice of materials – Mechanical seal housing
– Choice of liner materials
Other Configurations Other Configurations
• Severe-duty configuration • M horizontal hard metal, Other Configurations
• High pressure configuration abrasive slurry • RJ rubber lined slurry
• MJ slurry sump • RJC cantilever rubber lined
• MJC cantilever slurry sump See Bulletin PS-10-19 slurry sump

30 See Bulletin PS-10-19 See Bulletin PS-10-18


(FPD-100) Level 1.qxd 11/8/04 11:48 AM Page 31 Dan K. Snelson Clients:023-FLOWSERVE Pumps:023-Job Files:023-Open Jobs:0832-(FPD-100)

RJ and RJC Rubber Lined Titan Slurry Heavy-Duty, Terra-Titan


Slurry Sump Radially Split, Lined Vertical Cantilever Sump

Overhung – Slurry and Solids Handling


Standards Standards Standards
• Flowserve • Flowserve • Flowserve

Operating Parameters Operating Parameters Operating Parameters


• Flows to 225 m3/h (1000 gpm) • Flows to 3600 m3/h (16 000 gpm) • Flows to 250 m3/h (1100 gpm)
• Heads to 30 m (100 ft) • Heads to 90 m (300 ft) • Heads to 45 m (150 ft)
• Pressures to 10 bar (150 psi) • Sizes from 50 mm (2 in) • Pressures to 5 bar (70 psi)
• Temperatures to 110°C (225°F), to 350 mm (14 in) • Temperatures to 100°C (212°F)
depending on material • Sizes from 40 mm (1.5 in)
• Solids from 2% to 70% by weight Features to 125 mm (5.0 in)
• Speeds to 1780 rpm • Fully interchangeable elastomeric • Sump depths from 700 mm
or hard metal liners (28 in) to 1800 mm (72 in)
Features • Radially split casing
• RJ - Submerged bearing and lineshaft • High efficiency, closed impeller Features
design for deep setting • Ample seal chamber accommodates • One-piece suspended, oversized
• RJC - Cantilever design with no a variety of packing and seal types cantilever shaft construction
submerged bearings • Heavy-duty bearing frame sized • Interchangeable urethane or hard
• Radically split casing with anti- to handle belt loads metal wetted parts
prerotation vanes in suction nozzle • Bearing cartridge with back-to-back • Concentric casing design
• Casing liners pressure molded on angular contact thrust bearings • Double suction, hydraulically
steel backing plates • Roller type radial bearings balanced open impeller
– Multiple materials available • Contact lip seals • External impeller adjustment
• Pressure molded closed impeller with • Dimensionally compatible with the • Renewable Terraprene urethane
pump-out vanes on front and rear industry’s most widely used pumps shaft sleeve
shrouds • Optional expeller for dynamic sealing • Greased for life, heavy-duty,
• RJ has fluted “Cutlass” rubber self-aligning roller bearings
bearings See Bulletin PS-10-8 • Upper and lower strainers
• RJC has “Thordon” restriction • Run-dry capability
bushing • ANSI and ISO configurations
• Directly coupled or V-belt driven • Portable
• Options • Lifting lugs
– Hard metal expeller • Rigid motor mount pivot bar
– Choice of liner materials • Available bottom suction tailpipe
• Multiple drive options
Other Configurations
• R horizontally split rubber See Bulletin PS-10-7
lined slurry

See Bulletin PS-10-18 31


(FPD-100) Level 1.qxd 11/8/04 11:48 AM Page 32 Dan K. Snelson Clients:023-FLOWSERVE Pumps:023-Job Files:023-Open Jobs:0832-(FPD-100)

LC Chemical Slurry MND Hard Metal MNR Rubber Lined


Absorber Recirculation Absorber Recirculation
Overhung – Slurry and Solids Handling

Standards Standards Standards


• Flowserve • Flowserve • Flowserve

Operating Parameters Operating Parameters Operating Parameters


• Flows to 8000 m3/h (35 200 gpm) • Flows to 17 500 m3/h (77 000 gpm) • Flows to 17 500 m3/h (77 000 gpm)
• Heads to 100 m (325 ft) • Heads to 40 m (130 ft) • Heads to 40 m (130 ft)
• Pressures to 25 bar (365 psi) • Sizes from 600 mm (24 in) to • Sizes from 600 mm (24 in) to
• Temperatures to 140°C (285°F) 1000 mm (40 in) 1000 mm (40 in)
• Specific gravities to 1.7
Features Features
Features • One-piece, high efficiency impeller • One-piece, high efficiency impeller
• Concentric casing with tangential with mixed flow vane design with mixed flow vane design
discharge • Multiple materials of construction • Removable one-piece elastomeric
• Rigid, one-piece bearing frame • Replaceable casing wear ring casing liner
with two angular contact outboard • Opposed tapered roller bearings • Radially split casing
bearings and roller inboard bearings designed for a minimum B10 life • Multiple materials of construction
• Large diameter, heavy-duty shaft of 100 000 hours • Replaceable casing wear ring
• Choice of shaft sealing options • Product flush slurry seal • Opposed tapered roller bearings
– Wet gland packing • External end clearance adjustment designed for a minimum B10 life
– Single or double mechanical seal • Front and back pullout of 100 000 hours
– High pressure double • Product flush slurry seal
Other Configurations • External end clearance adjustment
mechanical seal
• Vertical configuration • Front and back pullout
– Special high solids seals
• MNR rubber lined absorber
– Alumina industry seal
recirculation Other Configurations
• Choice of materials of construction
• Multiple impeller designs • Vertical configuration
See Bulletin PS-10-32 • MND hard metal absorber
• Direct coupled or belt driven
• Choice of six drive arrangements recirculation
• Options
– Inducer See Bulletin PS-10-32
– Stuffing box cooling system

Other Configurations
• PL-C cantilever chemical
slurry sump
• LC-S lineshaft chemical
slurry sump

32 See Bulletin PS-10-11


(FPD-100) Level 1.qxd 11/8/04 11:48 AM Page 33 Dan K. Snelson Clients:023-FLOWSERVE Pumps:023-Job Files:023-Open Jobs:0832-(FPD-100)

FRBH Heavy-Duty Paper FRBHJC Cantilever Primo-Titan Self-Priming,


Stock and Process Sump Solids Handling

Overhung – Slurry and Solids Handling


Standards Standards Standards
• Flowserve • Flowserve • Flowserve

Operating Parameters Operating Parameters Operating Parameters


• Flows to 6500 m3/h (30 000 gpm) • Flows to 2700 m3/h (12 000 gpm) • Flows to 600 m3/h (2650 US gpm)
• Heads to 100 m (325 ft) • Heads to 100 m (325 ft) • Heads to 35 m (115 ft)
• Temperatures to 150°C (300°F) • Temperatures to 150°C (300°F) • Temperatures to 75°C (165°F)
• Speeds to 1780 rpm • Working pressures to 5 bar (72 psi)
Features • Sizes 50 to 200 mm (2 to 8 in)
• Self-venting, top centerline Features • Solids to 75 mm (3 in) diameter
discharge casing • True stiff shaft cantilever design,
• Semi-open, full vane impeller with without bottom bearing or Features
back pump-out vanes flushing water • Two-vane, semi-open, solids
• Large suction inlet • Steep head-capacity handling impeller
• Seal chamber accepts packing or • Semi-open, full vane impeller with • External impeller adjustment
mechanical seal back pump-out vanes • Abrasion-resistant double
• Three-point end clearance adjustment • Stuffing box accommodates multiple mechanical seal
• Back pull-out design seal types • Quick-disconnect cover plate
• Heavy-duty, oil-lubricated bearings • Direct coupled or V-belt driven • Heavy-duty, volute casing
• Fully split interlocking glands • Extra heavy-duty alloy steel shaft • Replaceable seal housing
• Extra heavy-duty alloy steel shaft • Replaceable and reversible
• Contoured wearplate match Other Configurations wear plate
machined with impeller • FRBH heavy-duty paper stock and • Solid one-piece flap valve
• Dry shaft construction with sealed process • Back pull-out design
impeller nut and stainless steel • FRBHJ vertical lineshaft sump • Trailer mounting capability
hook sleeve • Multiple drive options
• Rigid, one-piece bearing frame See Bulletin PS-10-16 • Extra large diameter shaft
• Options
– Large conical seal housing See Bulletin PS-10-9
– Inducer
– Expeller
– Recessed impeller

Other Configurations
• FRBHJC cantilever sump
• FRBHJ sump

See Bulletin PS-10-16


33
(FPD-100) Level 1.qxd 11/8/04 11:49 AM Page 34 Dan K. Snelson Clients:023-FLOWSERVE Pumps:023-Job Files:023-Open Jobs:0832-(FPD-100)

MN Large Capacity, MF Solids Handling MSX Solids Handling,


Solids Handling Submersible
Overhung – Slurry and Solids Handling

Standards Standards Standards


• Flowserve • Flowserve • Flowserve

Operating Parameters Operating Parameters Operating Parameters


• Flows to 45 500 m3/h (200 000 gpm) • Flows to 2275 m3/h (10 000 gpm) • Flows to 4550 m3/h (20 000 gpm)
• Heads to 90 m (300 ft) • Heads to 90 m (300 ft) • Heads to 90 m (300 ft)
• Sizes to 1800 mm (72 in) • Sizes to 400 mm (16 in) • Sizes to 500 mm (20 in)
• Motor to 300 kW (400 hp)
Features Features • Solids handling to 80 mm
• Variety of nozzle position options • Variety of nozzle position options (3 in) spherical
• Direct or independent motor mounting • Direct or independent motor mounting
• Minimal shaft deflection • Minimal shaft deflection Features
• Oversized shaft and reduced overhang • Oversized shaft and reduced overhang • High efficiency hydraulics
• Hardened chrome steel wear rings • Hardened chrome steel wear rings • EPACT rated motor
• Stuffing box accommodates packing • Stuffing box readily accommodates • Spike-resistant windings
or mechanical seals packing or mechanical seals • Class H rated insulation system
• Adjustable wear ring clearance • Shaft sleeve options • Dynamically balanced shaft
• Shaft sleeve options – 316 stainless steel and rotor
– 316 stainless steel – Hardened chrome steel • Available configurations
– Hardened chrome steel • Bearing housing features – MSX Series 1 – Sizes from
• Bearing housing features – Ball or tapered roller bearings 75 mm (3 in) to 150 mm (6 in)
– Tapered roller bearings – Integral jacking bolts for wear – MSX Series 2/3 – Sizes to
– Integral jacking bolts for wear ring ring adjustment 500 mm (20 in)
adjustment – Accessible lubrication points • Mounting options
– Accessible lubrication points – Wet pit
Other Configurations – Dry-pit
Other Configurations • MF horizontal, end-suction – Transportable
• MN horizontal, end-suction • MFV vertical with motor on
• MNF vertical, bottom suction, direct separate floor (shown above) See Bulletin PS-50-2
connected motor • MFC vertical with direct connected
• MNZ vertical, bottom suction, motor motor
on separate floor
• MNC vertical with base elbow, direct See Bulletin PS-10-3
connected motor
• MNV vertical with base elbow, motor
on separate floor (shown above)

See Bulletin PS-10-4


34
(FPD-100) Level 1.qxd 11/8/04 11:49 AM Page 35 Dan K. Snelson Clients:023-FLOWSERVE Pumps:023-Job Files:023-Open Jobs:0832-(FPD-100)

Drain-Titan D800 Series Cast Iron MEN and MEN-SP


Double Suction, End-Suction
Urethane Lined Sump

Overhung – General Industry


Standards Standards Standards
• Flowserve • Flowserve • DIN 24255
• EN 733
Operating Parameters Operating Parameters • Flowserve
• Flows to 160 m3/h (700 gpm) • Flows to 340 m3/h (1500 gpm)
• Heads to 40 m (130 ft) • Heads to 120 m (395 ft) Operating Parameters
• Pressures to 4 bar (55 psi) • Pressures to 15 bar (220 psi) • Flows to 700 m3/h (3080 gpm)
• Sizes from 40 mm (1.5 in) to • Temperatures to 120°C (250°F) • Heads to 100 m (330 ft)
100 mm (4 in) • Pressures to 16 bar (230 psi)
• Solids to 15 mm (0.5 in) Features • Temperatures to 120°C (250°F)
• High efficiency closed impeller
Features • Centerline discharge Features
• Double suction, urethane coated • Sealed-for-life pre-lubricated motor • Modular design concept
wet-end bearings with two-year minimum life • 33 sizes available
• Robust, integral unit construction • Renewable wear rings and shaft • Top discharge casing
• Large diameter, stiff cantilever sleeves • Fully machined, high efficiency,
drive shaft • Pre-set mechanical seal assembly shrouded impeller
• No submerged bearings or seals • Bell type mechanical seal cover • Impeller balance holes for
• Double sided impeller with • Standard NEMA C-face motor reduced thrust
pre-set clearance • Back pull-out design • Open seal chamber with integral
• Keyed and bored shaft coupling • Threaded and flanged connections vortex breaking ribs
• Standard single lip oil seal • Configuration options • Stainless steel shaft
• Urethane lined, slotted outlet – Type D-814 - Frame mounted • Oversized bearings
pipe flange – Type D-824 - Close-coupled • Standard case wear rings
• Grease lubricated, single row, – Type D-834 - Vertical in-line • Back pull-out design
deep groove ball bearings
• No priming required See Bulletin PS-10-6 Other Configurations
• Run-dry capability • MHP high-pressure water pump
• MENBLOC close coupled water pump
See Bulletin PS-10-7 • ME high capacity, vertical water pump
• MEV high capacity, vertical
water pump

See Bulletin PS-10-2

35
(FPD-100) Level 1.qxd 11/8/04 11:49 AM Page 36 Dan K. Snelson Clients:023-FLOWSERVE Pumps:023-Job Files:023-Open Jobs:0832-(FPD-100)

F-Line End-Suction, SMP Standard Motor VSMP Vertical,


Multistage Standard Motor
Overhung – General Industry

Standards Standards Standards


• Flowserve • Flowserve • Flowserve

Operating Parameters Operating Parameters Operating Parameters


• Flows to 500 m3/h (2200 gpm) • Flows to 135 m3/h (600 gpm) • Flows to 135 m3/h (600 gpm)
• Heads to 250 m (820 ft) • Heads to 70 m (220 ft) • Heads to 70 m (220 ft)
• Discharge pressures to 25 bar • Pressures to 12 bar (175 psi) • Pressures to 12 bar (175 psi)
(365 psi) • Temperatures from -40°C (-40°F) to • Temperatures from -40°C (-40°F)
• Temperatures to 105°C (220°F) 120°C (250°F) to 120°C (250°F)

Features Features Features


• Modular design • Glass reinforced polymer, high • Glass reinforced polymer, high
– 8 sizes efficiency, semi-open or closed efficiency, semi-open or closed
– 15 hydraulics impellers standard impellers standard
– 2 impeller types • Industry standard NEMA motors • Industry standard NEMA motors
• To 9 stages, depending on model • Stainless steel, self-aligned • Stainless steel, self-aligned
and operating speed mechanical seal mechanical seal
• Sleeved shaft under sealing system • Back pull-out design • Back pull-out design
• Cast iron EN-GJL 250 pressure • Clamp-type mounting plate • Clamp-type mounting plate
casings • Options • Options
• Cast iron EN-GJL 250 or NORYL® – Cast iron, bronze or 316 SS – Cast iron, bronze or 316 SS
impellers and diffusers, depending impellers impellers
upon model – Stub shaft design – Stub shaft design
• Steel grade C 35 E shaft
• 13% chromium steel sleeve Other Configurations Other Configurations
• SMX non-metallic standard motor • SMP standard motor pump
Configurations pump • SMX non-metallic standard
• FP horizontal, overhung impeller • VSMP vertical standard motor pump motor pump
• FM horizontal, close coupled
• FD and FS verticals See Bulletin PS-10-26 See Bulletin PS-10-26
• FAD and FMD vertical, close coupled

® NORYL is a registered trademark of


General Electric Company

36
(FPD-100) Level 1.qxd 11/8/04 11:49 AM Page 37 Dan K. Snelson Clients:023-FLOWSERVE Pumps:023-Job Files:023-Open Jobs:0832-(FPD-100)

SMX Non-Metallic ECPJ (VS4 and VS5) ESP2 Vertical Immersion


Standard Motor Sump Sump

Overhung – General Industry


Standards Standards Standards
• Flowserve • API 610 (VS4 and VS5), latest edition • Flowserve

Operating Parameters Operating Parameters Operating Parameters


• Flows to 25 m3/h (100 gpm) • Flows to 500 m3/h (2200 gpm) • Flows to 800 m3/h (3500 gpm)
• Heads to 20 m (60 ft) • Heads to 150 m (500 ft) • Heads to 90 m (300 ft)
• Pressures to 12 bar (175 psi) • Pressures to 16 bar (230 psi) • Pressures to 12 bar (175 psi)
• Temperatures to 80°C (180°F) • Temperatures to 350°C (660°F) • Temperatures to 180°C (350°F)
• 42 sizes available
Features Features
• Polyphenylene sulfide (PPS) casing, Features • Optimized lineshaft bearing design
adapter and impeller • Lineshaft (VS4) and cantilever (VS5) to API 610 spacing requirements
• Standard NEMA 56J frame C-faced configurations available • Double row external thrust bearings
motor • Four impeller designs to suit • Single and duplex configurations
• Stainless steel, self-aligned hydraulic requirements • Flanged discharge
mechanical seal – Closed multivane impeller with • Large basket strainer
• Back pull-out design front wear rings and back vanes • Industry standard TCV motors
• 40 mm (1.5 in) port size for hose – Closed multivane impeller with • Lubrication options
connection front and rear wear rings – Product lube design
– Open multivane impeller with for clear liquids
Other Configurations back vanes – Dual particle separator
• SMP standard motor pump – Free flow impeller with back vanes for light solids
• VSMP vertical standard motor pump • Multiple shaft sealing options – Grease lubrication
– V-ring • Mounting plate sealing options
See Bulletin PS-10-26 – Throttle bushing – Vapor tight
– Lip seal with grease-filled – Vapor proof
stuffing box – Pressurized design
– Soft packing • Options
• API 682 seal chamber accommodates – Upper stuffing box
multiple seal types – Sealing ring
• Column lengths to 6 m (22 ft) – Suction tailpipes
– Suction pipe available – Level controls
• Choice of API materials
• NACE MR0175 materials available See Bulletin PS-10-24
• Internal or external bearing flushing
• Bearing cooling
• Suction strainer

37
(FPD-100) Level 1.qxd 11/8/04 11:49 AM Page 38 Dan K. Snelson Clients:023-FLOWSERVE Pumps:023-Job Files:023-Open Jobs:0832-(FPD-100)
(FPD-100) Level 1.qxd 11/8/04 11:49 AM Page 39 Dan K. Snelson Clients:023-FLOWSERVE Pumps:023-Job Files:023-Open Jobs:0832-(FPD-100)

Between Bearings
Pumps

Single Case - Axially Split

Between Bearings Pumps


LNN Single Stage 40
LR Single Stage 40
LRV Vertical 40
LLR Two Stage 41
LNGT Single Stage 41
GT Two Stage 41
DVSH Single Stage 42
UZDL Two Stage 42
DMX Multistage 42

Single Case - Radially Split


HDX Double Suction 43
HED Two Stage 43
HED-DS Two Stage 43
WXH Multistage Ring
Section 44
WDX and WD Multistage
Ring Section 44
NM Multistage Ring
Section 44
CS Multistage Ring
Section 45

Double Case
WXB Diffuser Utility 46
WNC-HP Diffuser Utility 46
WNC Diffuser Utility 46
CSB Diffuser Utility 47
CHTA Diffuser Utility 47
HDB and HSB Volute
Utility 47
WIK Diffuser Process 48
WCC Diffuser Process 48
HDO and HSO Volute
Process 48

39
(FPD-100) Level 1.qxd 11/8/04 11:50 AM Page 40 Dan K. Snelson Clients:023-FLOWSERVE Pumps:023-Job Files:023-Open Jobs:0832-(FPD-100)

LNN Axially Split, LR Axially Split, LRV Vertical, Axially Split,


Single Stage Single Stage Single Stage
Between Bearings – Single Case - Axially Split

Standards Standards Standards


• Flowserve • Flowserve • Flowserve

Operating Parameters Operating Parameters Operating Parameters


• Flows to 51 000 m3/h (225 000 gpm) • Flows to 2000 m3/h (8800 gpm) • Flows to 2000 m3/h (8800 gpm)
• Heads to 300 m (980 ft) • Heads to 170 m (560 ft) • Heads to 137 m (450 ft)
• Pressures to 30 bar (435 psi) • Pressures to 21 bar (300 psi) • Pressures to 21 bar (300 psi)
• Temperatures to 150°C (300°F) • Temperatures from -30°C (-20°F) • Temperatures from -30°C (-20°F)
to 150°C (300°F) to 150°C (300°F)
Features
• Hydraulically balanced, double Features Features
suction impeller • Split case design with lifting lugs • Split case design with lifting lugs
• Dynamically balanced to ISO 1940 • Low NPSH enclosed double • Low NPSH enclosed double
tolerances suction impeller suction impeller
• Heavy-duty double volute casing with • Flat or raised face suction and • Small footprint reduces floor
suction and discharge flanges to discharge flanges to ANSI, DIN and space requirement
ANSI, DIN and ISO standards ISO standards • Flat or raised face suction and
• Optimum axial and radial thrust • Oil or grease lubricated radial and discharge flanges to ANSI, DIN and
balance thrust bearings ISO standards
• Seal chamber accommodates – Single row, deep groove ball bear- • Product-lubricated bottom bearing
packing and mechanical seals ings or duplex thrust ball bearings • Seal chamber accommodates
• Choice of bearings – 100 000 hours typical L10 multiple seal types
– Antifriction ball bearings standard bearing life • Standard case wear rings
– Double row, angular contact thrust • Seal chamber accommodates • Optional impeller wear rings
bearings option multiple seal types • Available high performance coatings
– Sleeve radial and hydrodynamic • Standard case wear rings
thrust bearings option – Optional serrated groove designs Other Configurations
• Choice of lubrication options • Optional impeller wear rings • LR axially split, single stage
• Available high performance coatings • LLR axially split, two stage
Other Configurations
• LNNV axially split, vertical in-line Other Configurations See Bulletin PS-20-3
• LNNC axially split, bottom suction, • LRV vertical, axially split,
side discharge single stage
• LLR axially split, two stage
See Bulletin PS-20-1
See Bulletin PS-20-3

40
(FPD-100) Level 1.qxd 11/8/04 11:58 AM Page 41 Dan K. Snelson Clients:023-FLOWSERVE Pumps:023-Job Files:023-Open Jobs:0832-(FPD-100)

LLR Axially Split, LNGT Axially Split, GT Axially Split,


Two Stage Single Stage Two Stage

Between Bearings – Single Case - Axially Split


Standards Standards Standards
• Flowserve • Flowserve • Flowserve

Operating Parameters Operating Parameters Operating Parameters


• Flows to 295 m3/h (1300 gpm) • Flows to 14 000 m3/h (61 600 gpm) • Flows to 840 m3/h (3700 gpm)
• Heads to 290 m (950 ft) • Heads to 260 m (850 ft) • Heads to 380 m (1250 ft)
• Pressures to 31 bar (450 psi) • Pressures to 150 bar (2175 psi) • Pressures to 34 bar (500 psi)
• Temperatures from -30°C (-20°F) • Temperatures to 105°C (220°F) • Temperatures from -30°C (-20°F)
to 150°C (300°F) • Speeds to 3600 rpm to 150°C (300°F)

Features Features Features


• Split case design with wear rings • Double suction radial impeller • Horizontally split case with
• Back-to-back mounted, single • Double volute configurations semi-centerline support
suction impellers • Special hydraulic design • Back-to-back mounted, single suction
• First and second stage volutes suction boxes impellers
spaced 180° apart • Modular design • Flange mounted bearing housings
• Crossover cast-in upper casing half • In-line suction and discharge nozzles • Ring-oil lubricated ball bearings
• Flat or raised face suction and • ANSI, DIN or ISO flanges • Carbon steel shaft
discharge flanges to ANSI, DIN and • Replaceable casing rings • Deep stuffing boxes
ISO standards • Optional impeller rings • Renewable stationary wear parts
• Oil or grease lubricated radial and • Ball bearings or double row • Formed steel baseplate
thrust bearings roller bearings • Standard flexible, on-spacer
– Single row, deep groove ball bear- • Oil or grease lubrication type coupling
ings or duplex thrust ball bearings • Choice of materials • Cast iron casing, bronze or
– 100 000 hours typical L10 – Cast iron cast iron fitted
bearing life – Ni-Resist
• Seal chamber accommodates – Gunmetal bronze
multiple seal types – Nickel-aluminum bronze
• Interstage bushing
• Optional impeller wear rings

Other Configurations
• LR axially split, single stage
• LRV vertical, axially split,
single stage

See Bulletin PS-20-3


41
(FPD-100) Level 1.qxd 11/8/04 11:59 AM Page 42 Dan K. Snelson Clients:023-FLOWSERVE Pumps:023-Job Files:023-Open Jobs:0832-(FPD-100)

DVSH (BB1) UZDL (BB1) DMX (BB3)


Axially Split, Single Stage Axially Split, Two Stage Axially Split, Multistage
Between Bearings – Single Case - Axially Split

Standards Standards Standards


• API 610 (BB1), latest edition • API 610 (BB1), latest edition • API 610 (BB3), latest edition

Operating Parameters Operating Parameters Operating Parameters


• Flows to 22 700 m3/h (100 000 gpm) • Flows to 2950 m3/h (13 000 gpm) • Flows to 2950 m3/h (13 000 gpm)
• Heads to 510 m (1500 ft) • Heads to 685 m (2250 ft) • Heads to 2130 m (7000 ft)
• Pressures to 150 bar (2175 psi) • Pressures to 64 bar (910 psi) • Pressures to 275 bar (4000 psi)
• Temperatures to 200°C (400°F) • Temperatures to 200°C (400°F) • Temperatures to 200°C (400°F)
• Speeds to 6000 rpm • Speeds to 8000 rpm
Features
Features • Double volute hydraulic passages Features
• Double volute casing • API 682 seal chambers • Double volute hydraulic passages
• Hydraulically balanced double • Shaft options • API 682 seal chambers
suction impeller – Double extension for connection • Shaft options
• API 682 seal chambers to auxiliary pumps or hydraulic – Double extension for connection
• Stiff shaft design turbines to auxiliary pumps or hydraulic
• Baseplates designs and pump – Special shaft end machining for turbines
packages engineered to contract hydraulic fitted couplings – Special shaft end machining
requirements • Baseplate designs and pump for hydraulic fitted couplings
• Choice of bearings packages engineered to contract • Baseplate designs and pump
– Ball radial and thrust requirements packages engineered to contract
– Sleeve radial and ball thrust • Dynamic balancing and TIR requirements
– Sleeve radial and tilting pad thrust verifications on assembled rotors • Dynamic balancing and TIR
– Tilting pad radial and tilting • Choice of bearings verifications on assembled rotors
pad thrust – Ball radial and thrust • Choice of bearings
• Choice of materials – Sleeve radial and ball thrust – Ball radial and thrust
– Carbon steel – Sleeve radial and tilting pad thrust – Sleeve radial and ball thrust
– 12% chrome – Tilting pad radial and tilting – Sleeve radial and tilting pad thrust
– Austenitic and duplex pad thrust – Tilting pad radial and tilting
stainless steels • Choice of materials pad thrust
– Monel® – Carbon steel • Choice of materials
– 12% chrome
See Bulletin PS-20-2 – Austenitic and duplex See Bulletin PS-30-3
stainless steels
® Monel is a registered trademark of
International Nickel Co – Monel

42
(FPD-100) Level 1.qxd 11/8/04 11:59 AM Page 43 Dan K. Snelson Clients:023-FLOWSERVE Pumps:023-Job Files:023-Open Jobs:0832-(FPD-100)

HDX (BB2) Radially Split, HED (BB2) HED-DS (BB2)


Double Suction Radially Split, Two Stage Radially Split, Double
Suction, Two Stage

Between Bearings – Single Case - Radially Split


Standards Standards Standards
• API 610 (BB2), latest edition • API 610 (BB2), latest edition • API 610 (BB2), latest edition

Operating Parameters Operating Parameters Operating Parameters


• Flows to 4100 m3/h (18 000 gpm) • Flows to 1000 m3/h (4400 gpm) • Flows to 2000 m3/h (8500 gpm)
• Heads to 450 m (1500 ft) • Heads to 650 m (2100 ft) • Heads to 750 m (2500 ft)
• Pressures to 100 bar (1500 psi) • Pressures to 80 bar (1160 psi) • Pressures to 80 bar (1160 psi)
• Temperatures to 450°C (850°F) • Temperatures to 450°C (850°F) • Temperatures to 450°C (850°F)

Features Features Features


• Double-volute, centerline supported, • Heavy-duty double-volute, casing • Double suction first stage impeller
self-venting casing with 180° staggered volutes • Heavy-duty double-volute casing
• Minimum ANSI B16.5 • Suction and discharge nozzles with 180° staggered volutes
Class 300 suction and discharge available in top-top, in-line side • Suction and discharge nozzles
flanges or same side configurations available in top-top, in-line side or
– Optional Class 600 and 900 flanges • First and second stage volutes same side configurations
• Dynamically balanced, double spaced 180° apart • First and second stage volutes
suction impeller • API 682 seal chambers spaced 180° apart
• Stiff shaft design • Dynamic balancing and TIR verifications • API 682 seal chambers
• API 682 seal chambers on assembled rotating element • Dynamic balancing and TIR verifications
• Standard dual, single-row, back-to- • Baseplate designs and pump packages on assembled rotating element
back mounted, angular contact type engineered to contract requirements • Baseplate designs and pump packages
thrust bearing • Choice of bearings engineered to contract requirements
• Bearing options – Ball radial and thrust • Choice of bearings
– Sleeve radial and ball thrust – Sleeve radial and ball thrust – Ball radial and thrust
– Sleeve radial and tilting pad thrust – Sleeve radial and tilting pad thrust – Sleeve radial and ball thrust
– Lubrication systems available • Choice of materials – Sleeve radial and tilting pad thrust
• 360° supported bearing housing – Carbon steel • Choice of materials
• Double casing covers – 12% chrome – Carbon steel
– Austenitic and duplex – 12% chrome
Other Configurations stainless steels – Austenitic and duplex
• In-line side nozzles – Monel lining stainless steels
• Side-side nozzles – Monel lining
Other Configurations
See Bulletin PS-20-4 • HED-DS radially split, double suction, Other Configurations
two stage • HED radially split, two stage

43
(FPD-100) Level 1.qxd 11/8/04 11:59 AM Page 44 Dan K. Snelson Clients:023-FLOWSERVE Pumps:023-Job Files:023-Open Jobs:0832-(FPD-100)

WXH Radially Split, WDX and WD Radially NM Radially Split,


Multistage, High Pressure, Split, Multistage, Multistage, Ring Section
Ring Section Ring Section
Between Bearings – Single Case - Radially Split

Standards Standards Standards


• Flowserve • Flowserve • Flowserve

Operating Parameters Operating Parameters Operating Parameters


• Flows to 1160 m3/h (5100 gpm) • Flows to 190 m3/h (800 gpm) • 850 m3/h (3740 gpm)
• Heads to 2750 m (9000 ft) • Heads to 700 m (2300 ft) • 700 m (2300 ft)
• Pressures to 310 bar (4500 psi) • Pressures to 75 bar (1090 psi) • Discharge pressures to 60 bar
• Temperatures to 200°C (400°F) • Temperatures to 210°C (410°F) (870 psi)
• Temperatures to 140°C (285°F)
Features Features
• Cast suction and discharge heads • Multivane diffusers Features
with integral nozzles • Identical radially-split ring • Modular design
• Single or double suction first stage section sets – 10 sizes
impeller designs • O-ring interstage sealing – 12 hydraulics
• Investment cast diffusers and return arrangement • Radial thrust balanced by diffusers
channel hydraulic passages • Deep-groove ball bearing design • Two to 12 stages, depending on
• Compression type interstage O-ring • Angular contact, double row model and operating speed
• Separate, high strength sub-base thrust bearing • Cast iron EN-GJL 250 pressure
• Replaceable stationary wear parts • 360° machine registered bearing casings, with EN-GJS 400-15 optional
mounted in the diffusers housing fits • Cast iron EN-GJL 250 impellers
• Standard flanged balance drum with • Dynamically balanced, precision and diffusers
serrated running clearances machined enclosed impellers • Steel grade C 35 E or stainless steel
– Optional straight balance drum • Packing or mechanical sealing X30Cr13 shaft, depending on size
• Seal chamber accepts single, double • Options and model
and tandem mechanical seals – Multiple flange orientations • Stainless steel X30Cr13 sleeves
• Large diameter shaft with staggered – End suction design with product • Packing gland or mechanical sealing
impeller and balancing device keyways lubricated sleeve bearing
• No pre-warming required – Radial suction design with product Other Configurations
• Chrome steel nozzles lubricated sleeve bearing • NM-V vertical model with supported
• Choice of bearings – Inducer motor stand
• NM-Y vertical model with Cardan
Other Configurations transmission and upper level motor
• WXL heavy-duty, radially split, high mounting
pressure, ring section pump • NM-S vertical wet pit suspended shaft
• WXM heavy-duty, radially split, high
pressure, ring section pump

See Bulletin PS-30-1


44
(FPD-100) Level 1.qxd 11/8/04 11:59 AM Page 45 Dan K. Snelson Clients:023-FLOWSERVE Pumps:023-Job Files:023-Open Jobs:0832-(FPD-100)

CS Radially Split,
Multistage, Ring Section

Between Bearings – Single Case - Radially Split


Standards
• Flowserve

Operating Parameters
• Flows to 615 m3/h (2700 gpm)
• Heads to 1465 m (4800 ft)
• Pressures to 125 bar (1800 psi)
• Temperatures from -30°C (-20°F)
to 165°C (330°F)

Features
• Separate cast diffusers and
channel rings
• Secondary O-ring seals
• Complete radial balance
• Press fit stationary wear parts
• Balance disc wear indicator
• Flanged or straight balance drum
available to suit the application
• Centerline mounted casing
• Optional nozzle orientation
• Choice of bearings
– Ball radial and thrust
– Sleeve radial and ball thrust
– Sleeve radial and tilting
pad thrust

45
(FPD-100) Level 1.qxd 11/8/04 12:00 PM Page 46 Dan K. Snelson Clients:023-FLOWSERVE Pumps:023-Job Files:023-Open Jobs:0832-(FPD-100)

WXB WNC-HP High Pressure WNC


Multistage, Diffuser Multistage, Diffuser Multistage, Diffuser
Casing, Utility Barrel Casing, Utility Barrel Casing, Utility Barrel
Between Bearings – Double Case

Standards Standards Standards


• ASME Section VIII • ASME Section VIII • ASME Section VIII

Operating Parameters Operating Parameters Operating Parameters


• Flows to 300 m3/h (1320 gpm) • Flows to 2500 m3/h (11 000 gpm) • Flows to 1400 m3/h (6200 gpm)
• Pressures to 150 bar (2175 psi) • Pressures to 400 bar (5850 psi) • Pressures to 250 bar (3600 psi)
• Temperatures to 200°C (390°F) • Temperatures to 250°C (480°F) • Temperatures to 200°C (390°F)
• Speeds to 8000 rpm
Features Features
• Diffuser case construction Features • Diffuser case construction
• Removeable cartridge type • Internal casing with segmented • Shear ring design
inner case sub-assembly stage elements • High strength forged steel barrel,
• Large eye first stage impeller • Diffuser guide vane construction – Alloy barrels available
• Patented balancing device • Removable cartridge type • Removable cartridge type
• Sleeve mounted deep groove radial inner case sub-assembly inner case sub-assembly
and back-to-back mounted angular • Precision cast chrome steel • Shear ring barrel closing system
contact bearings in-line impellers • Single or double suction first
• Bearing lubrication system • Single or double suction stage impeller
– Oil bath first stage impeller • Standard antifriction or sleeve type
– Constant level oiler • Heavy duty barrel with radial bearings
– Oil sight glass discharge cover • High capacity antifriction type thrust
• High capacity antifriction type – Forged steel bearing
thrust bearing • Fully enclosed or shrouded – Tilting pad thrust bearing available
• Renewable casing and impeller rings precision cast diffusers on high • Renewable casing rings
• High shaft diameter to bearing energy applications • Straight balance drum forged from
span ratio • Tilt pad thrust and Tri-Land hardened stainless steel
• Options radial bearings • Chrome plated shafting under
– Hydrodynamic sleeve type • Serrated running fits journal bearings
radial bearings • Renewable casing rings • Ground forged steel shafting
– Air fan thrust bearing • Straight balance drum design
cooling system • Chrome plated shafting under Other Configurations
– Labyrinth type end seals journal bearings • WNC-HP high pressure multistage
• Ground forged steel shafting utility
See Bulletin PS-30-12
Other Configurations See Bulletin PS-30-12
• WNC multistage utility

See Bulletin PS-30-12


46
(FPD-100) Level 1.qxd 11/8/04 12:00 PM Page 47 Dan K. Snelson Clients:023-FLOWSERVE Pumps:023-Job Files:023-Open Jobs:0832-(FPD-100)

CSB CHTA HDB and HSB


Multistage, Diffuser Multistage, Diffuser Multistage, Volute
Casing, Utility Barrel Casing, Utility Barrel Casing, Utility Barrel

Between Bearings – Double Case


Standards Standards Standards
• ASME Section VIII • ASME Section VIII • ASME Section VIII

Operating Parameters Operating Parameters Operating Parameters


• Flows to 1500 m3/h (6600 gpm) • Flows to 5250 m3/h (23 000 gpm) • Flows to 4000 m3/h (17 600 gpm)
• Discharge pressures to 300 bar • Discharge pressures to 450 bar • Discharge pressures to 350 bar
(4400 psi) (6500 psi) (5100 psi)
• Temperatures to 250°C (480°F) • Temperatures to 250°C (480°F) • Temperatures to 250°C (480°F)
• Speeds to 8000 rpm • Speeds to 6000 rpm • Speeds to 8000 rpm

Features Features Features


• Internal casing with segmented • Internal casing with segmented • Double volute design
stage elements stage elements • Axially split inner casing
• Diffuser-guide vane construction • Diffuser-guide vane construction • Opposed impellers
• Precision cast in-line impellers of • Precision cast in-line impellers • Heavy-duty forged steel barrel
high quality chrome steel of high quality chrome steel and discharge cover
• Heavy-duty barrel with forged steel • Heavy-duty barrel with forged steel • Symmetrical upper and lower
discharge cover discharge cover half inner volutes
• Fully enclosed or shrouded precision • Fully enclosed or shrouded • Individually mounted and secured
cast diffusers on high energy precision cast diffusers on high impellers
applications energy applications • Dynamic balancing and TIR
• Tilt pad thrust and Tri-Land • Balance drum and sleeve, made verifications on assembled rotor
radial bearings from hardened stainless forgings • One full pressure sealing to
• Renewable casing rings and sleeves • Tilt pad thrust and Tri-Land atmosphere and one full pressure
• Flanged balance drum forged from radial bearings sealing to suction
hardened stainless steel • Serrated running fits • Minimal pressure breakdowns
– Straight drum optional • Renewable casing rings and sleeves across running clearances
• Chrome plated shafting under • Flanged balance drum design • Sleeve radial and tilting pad
journal bearings • Chrome plated shafting under thrust bearings
• Ground forged steel shafting journal bearings • Baseplate designs and pump
• Ground forged steel shafting packages engineered to contract
See Bulletin PS-30-12 requirements
See Bulletin PS-30-12
See Bulletin PS-30-12

47
(FPD-100) Level 1.qxd 11/8/04 12:00 PM Page 48 Dan K. Snelson Clients:023-FLOWSERVE Pumps:023-Job Files:023-Open Jobs:0832-(FPD-100)

WIK (BB5) WCC (BB5) HDO and HSO (BB5)


Multistage, Diffuser Multistage, Diffuser Multistage, Volute Casing,
Casing, Process Barrel Casing, Process Barrel Process Barrel
Between Bearings – Double Case

Standards Standards Standards


• API 610 (BB5), latest edition • API 610 (BB5), latest edition • API 610 (BB5), latest edition

Operating Parameters Operating Parameters Operating Parameters


• Flows to 4000 m3/h (17 600 gpm) • Flows to 1020 m3/h (4500 gpm) • Flows to 4000 m3/h (17 600 gpm)
• Discharge pressures to 450 bar • Heads to 3050 m (10 000 ft) • Discharge pressures to 400 bar
(6550 psi) • Discharge pressures to 270 bar (5800 psi)
• Temperatures to 450°C (840°F) (4000 psi) • Temperatures to 400°C (750°F)
• Speeds to 7600 rpm • Temperatures from -30°C (-20°F) • Speeds to 9000 rpm
to 425°C (800°F)
Features • Speeds to 7000 rpm Features
• Tandem impeller, diffuser-guide • Volute design axially split inner
vane style, radially split inner casing Features casing with opposed grouped
• Inner casing normally provided • Internal casing with segmented impellers
with a bolted head at one end stage elements • Heavy-duty barrel with forged steel
– Optional cartridge element design • Diffuser-guide vane construction discharge cover
– Optional shear ring design • Multi-vane diffuser-channel • Symmetrical upper and lower
• Heavy-duty barrel with forged steel ring collectors half inner volutes
discharge cover • Precision cast chrome steel in-line • Individually mounted and secured
• Radially split inner casings impellers impellers
• Multi-vane diffuser and channel • Single or double suction first • Dynamic balancing and TIR
ring design stage impeller verifications on assembled rotor
• Precision cast and milled diffusers • Heavy-duty barrel with • Double volute
• Straight style balance drum discharge cover • One full pressure sealing
• Tilt pad thrust and sleeve • Removeable cartridge type to atmosphere and one full
radial bearings inner case sub-assembly pressure sealing to suction
• Forged shafts, stepped at each • Straight or flanged balance drum • Sleeve radial and tilting pad
impeller and balance drum with serrated running surfaces thrust bearings
• NEMA taper shaft extension • Tilt pad thrust and heavy-duty • Baseplate designs and pump
• Large diameter shaft journal bearings packages engineered to contract
• Precision cast keyed impellers • Force feed lubricated bearings requirements
• Shrink fit impellers • Precision ground forged
• Coke crusher option for most sizes steel shafting See Bulletin PS-30-11

See Bulletin PS-30-11 See Bulletin PS-30-11

48
(FPD-100) Level 1.qxd 11/8/04 12:00 PM Page 49 Dan K. Snelson Clients:023-FLOWSERVE Pumps:023-Job Files:023-Open Jobs:0832-(FPD-100)

49
(FPD-100) Level 1.qxd 11/8/04 12:00 PM Page 50 Dan K. Snelson Clients:023-FLOWSERVE Pumps:023-Job Files:023-Open Jobs:0832-(FPD-100)

50
(FPD-100) Level 1.qxd 11/8/04 12:31 PM Page 51 Dan K. Snelson Clients:023-FLOWSERVE Pumps:023-Job Files:023-Open Jobs:0832-(FPD-100)

Vertical Pumps

Wet Pit - Radial, Mixed

Vertical Pumps
and Axial Flow
WUJ Wet Pit 52
VTP Vertical Turbine 52
QL and QLQ Wet Pit 52
VOP and VOA 53
VCT Mixed Flow 53
AFV Axial Flow 53

Double Case
VPC Vertical Turbine 54
WUC Multistage 54
QLC and QLQC Wet Pit 54
VPC Cryogenic 55
WUC-LNG Cryogenic 55
VKW and TKW Liquid
Expander 55

Submersible Motor
Pleuger SUBM
Water-Filled 56
Byron Jackson SUBM
Oil-Filled 56

Slurry and Solids Handling


QMN Wet Pit 57
MFV Solids Handling 57
MNV Solids Handling 57
FRBHJC Sump 58
MJ and MJC Slurry Sump 58
RJ and RJC Lined Sump 58
Terra-Titan Sump 59
MSX Submersible 59

Sump
CPXV Chemical Sump 60
ESP2 Sump 60
PolyChem VGRP Polymer
Composite 60
Drain-Titan Urethane
Lined 61
VSMP Standard Motor 61
ECPJ Sump 61

51
(FPD-100) Level 1.qxd 11/8/04 12:31 PM Page 52 Dan K. Snelson Clients:023-FLOWSERVE Pumps:023-Job Files:023-Open Jobs:0832-(FPD-100)

WUJ (VS1) Wet Pit VTP Vertical Turbine QL and QLQ Double Suction,
Twin Volute
Vertical – Wet Pit - Radial, Mixed and Axial Flow

Standards Standards Standards


• API 610 (VS1), latest edition • Flowserve • Flowserve
• ASME Sections VIII and IX
• Directive 94/9/EC (ATEX 100) Operating Parameters Operating Parameters
• Flows to 13 600 m3/h (60 000 gpm) • Flows to 20 000 m3/h (90 000 gpm)
Operating Parameters • Heads to 700 m (2300 ft) • Heads to 610 m (2000 ft)
• Flows to 3000 m3/h (13 000 gpm) • Pressures to 150 bar (2175 psi) • Pressures to 70 bar (1000 psi)
• Heads to 2000 m (6500 ft) • Temperatures from -200°C (-330°F) • Temperatures from -45°C (-50°F)
• Pressures to 200 bar (3000 psi) to 300°C (570°F) to 200°C (400°F)
• Temperatures from -200°C (-325°F) • Sizes from 150 mm (6 in) • Column sizes to 1200 mm (48 in)
to 350°C (660°F) to 1375 mm (55 in)
• Settings to 365 m (1200 ft) Features
Features • QL - Single stage
• Choice of radial or mixed flow Features • QLQ - Multistage
hydraulics • Above- or below-grade discharge • Enclosed lineshaft construction
• Optional axial thrust tilting pad • Enclosed, open or semi-open • Heavy-wall twin-volute casing
bearing configuration impellers • Double suction impeller
• Stiff shaft design • Open or enclosed lineshaft • Enclosed lubrication stuffing box
• API 682 seal chamber accommodates construction • Heavy-duty discharge head
multiple seal types • Product or oil bearing lubrication • Options
• Flanged spacer type coupling • Flanged or threaded column pipe – Vertical solid motors or hollow
• Screen-type, non-sparking • High pressure stuffing box shaft motors with thrust bearing
coupling guard • Rigid, adjustable coupling – Oiler and solenoid switch for
• Casing and impeller wear rings • Drive options pump bearing lubrication
• Reinforced motor stand – Vertical hollow shaft or solid shaft – Water, grease or oil low
• Optional inducer motor design pressure lubricant
– Dry or submersible electric motors – Open lineshaft for clean liquids
Other Configurations – Variable speed drives – Lubrication lines for bottom bearing
• WUC (VS6) double casing, – Engine with right angle gear – Rigid, adjustable spacer coupling
multistage – Steam turbine
• Options Other Configurations
See Bulletin PS-40-8 – Thrust balanced impeller • QLC double casing, double suction,
– O-ring bowl twin volute, single stage wet pit
– Adjustable flanged coupling • QLQC double casing, double suction,
twin volute, multistage wet pit
Other Configurations
• VPC vertical turbine, double casing See Bulletin PS-40-4

52 See Bulletin PS-40-7


(FPD-100) Level 1.qxd 11/8/04 12:31 PM Page 53 Dan K. Snelson Clients:023-FLOWSERVE Pumps:023-Job Files:023-Open Jobs:0832-(FPD-100)

VOP (VS3) Axial Flow and VCT Mixed Flow AFV Axial Flow
VOA (VS2) Mixed Flow

Vertical – Wet Pit - Radial, Mixed and Axial Flow


Standards Standards Standards
• API 610 (VS3 and VS2), latest edition • Flowserve • Flowserve
• Flowserve
Operating Parameters Operating Parameters
Operating Parameters • Flows to 113 550 m3/h (500 000 gpm) • Flows to 180 000 m3/h
VOA: • Heads to 110 m (350 ft) (800 000 gpm)
• Flows to 32 000 m3/h (140 000 gpm) • Sizes from 500 mm (20 in) to • Heads to 11 m (35 ft)
• Heads to 100 m (325 ft) 3000 mm (120 in) • Speeds to 1770 rpm
• Speeds to 1800 rpm • Sizes from 200 mm (8 in)
• Impeller sizes from 300 mm (12 in) Features to 3.1 m (123 in)
to 1625 mm (65 in) • Above- or below-grade discharge • Settings to 8 m (25 ft)
VOP: available
• Flows to 50 000 m3/h (220 000 gpm) • Non pull-out design or space-saving, Features
• Heads to 14 m (45 ft) pull-out construction • Above- or below-grade discharge
• Speeds to 1000 rpm • Open, semi-open and closed available
• Impeller sizes from 350 mm (14 in) impellers available • Discharge head cast for sizes
to 2000 mm (80 in) • Oil, fresh water or self-lubricating to 500 mm (20 in)
column construction – Larger sizes are fabricated
Features • Integral bearing retainer • Bowl assembly cast for sizes
• Above- or below-grade discharge • Packed stuffing box or 200 mm (8 in) to 685 mm (27 in)
available mechanical seal – Larger sizes fabricated
• Cast or fabricated discharge head • Rigid, adjustable coupling • Mechanically and hydraulically
depending on pump size • Shaft sleeves under the bearings and balanced axial flow design impeller
• Cast bowl assembly stuffing box • Drive options
• Impeller wear rings standard on VOP • Options – Vertical hollow shaft motor
and optional on VOA – Thrust collar – Vertical solid shaft motor. Rigid
• Mechanically and hydraulically – Sand cap coupling provided between motor
balanced design – Thrust bearing in the motor or and pump for shaft diameters
• Independent pump axial bearing pump support head greater than 75 mm (3 in)
• Tooth or flexible coupling • Engineered to customer specifications – Engine or steam turbine drive options
• Engine or steam turbine drive options • Options
• Options – Pull-out design
– Pullout design available on – Casing and impeller wear rings
VOA model
– Case wear rings See Bulletin PS-40-3
– Packed gland or mechanical seal

53
(FPD-100) Level 1.qxd 11/8/04 12:32 PM Page 54 Dan K. Snelson Clients:023-FLOWSERVE Pumps:023-Job Files:023-Open Jobs:0832-(FPD-100)

VPC (VS6) Vertical Turbine, WUC (VS6) QLC and QLQC Double
Double Casing Double Casing, Multistage Casing, Double Suction,
Twin Volute
Vertical – Double Case

Standards Standards Standards


• API 610 (VS6), latest edition • API 610 (VS6), latest edition • Flowserve
• ASME Sections VIII and IX • ASME Sections VIII and IX
• German Pressure Vessel Operating Parameters
Operating Parameters Association (AD) • Flows to 20 000 m3/h (90 000 gpm)
• Flows to 13 600 m3/h (60 000 gpm) • British Standard BS 5500 • Heads to 610 m (2000 ft)
• Heads to 1070 m (3500 ft) • Compliance with Pressure • Pressures to 70 bar (1000 psi)
• Pressures to 150 bar (2175 psi) Equipment Directive 97/23/EC • Temperatures from -45°C (-50°F)
• Temperatures from -45°C (-50°F) to 200°C (400°F)
to 232°C (450°F) Operating Parameters
• Flows to 3000 m3/h (13 000 gpm) Features
Features • Heads to 2000 m (6500 ft) • QLC - Single stage
• Diffuser design • Pressures to 200 bar (3000 psi) • QLQC - Multistage
• Above- or below-grade discharge • Temperatures from -200°C (-325°F) • Enclosed lineshaft construction
available to 350°C (660°F) • Double case construction
• Single or multistage designs • Heavy-wall twin-volute casing
• Large eye first stage impeller Features • Double suction impeller
• Product or oil bearing lubrication • Radial or mixed flow hydraulics • Enclosed lubrication stuffing box
• Flanged column pipe • Low suction-velocity can design • Heavy-duty discharge head
• High pressure stuffing box • Optional axial thrust tilting pad • Options
• Rigid, adjustable flanged spacer bearing configuration – Vertical solid motors or hollow shaft
type coupling • Stiff shaft design motors with thrust bearing
• Drive options • API 682 seal chamber accommodates – Oiler and solenoid switch for pump
– Standard solid shaft motor design; multiple seal types bearing lubrication
hollow shaft available • Flanged spacer type coupling – Water, grease, or oil low
– Variable speed drives • Screen-type, non-sparking pressure lubricant
– Engine with right angle gear coupling guard – Open lineshaft for clean liquids
– Steam turbine • Inside drain line – Lubrication lines for bottom bearing
• Other options • Casing and impeller wear rings – Rigid, adjustable spacer coupling
– Thrust balanced impeller • Reinforced motor stand
– O-ring bowl • Optional inducer Other Configurations
– Key and thrust ring construction • QL double suction, twin volute,
for impellers Other Configurations single stage, wet pit
• WUJ (VS1) wet pit • QLQ double suction, twin volute,
Other Configurations • WUC-LNG cryogenic (VS6) double multistage, wet pit
• VTP vertical turbine casing, multistage
See Bulletin PS-40-4
See Bulletin PS-40-7 See Bulletin PS-40-9
54
(FPD-100) Level 1.qxd 11/8/04 12:32 PM Page 55 Dan K. Snelson Clients:023-FLOWSERVE Pumps:023-Job Files:023-Open Jobs:0832-(FPD-100)

VPC Cryogenic (VS6) WUC-LNG Cryogenic (VS6) VKW and TKW Cryogenic
Double Casing, Multistage Double Casing, Multistage Liquid Expander (VS6)
Double Casing, Multistage,
Electric Generator

Vertical – Double Case


Standards Standards Standards
• API 610 (VS6), latest edition • API 610 (VS6), latest edition • API 610 (VS6), latest edition
• ASME Sections VIII and IX • ASME Sections VIII and IX • ASME Sections VIII and IX
• German Pressure Vessel • Shell DEP
Operating Parameters Association (AD) • NEMA MG1, latest edition
• Flows to suit site requirements • British Standard BS 5500 • Hazardous area classification (EExe)
• Heads to suit site requirements • Compliance with Pressure Equipment to the site country
• Discharge pressures to 148 bar Directive 97/23/EC
(2160 psi) Operating Parameters
• Temperatures from -200°C (-325°F) Operating Parameters • Expander flows to 1800 m3/h
to -46°C (-50°F) • Flows to 3000 m3/h (13 000 gpm) (7900 gpm)
• Heads to 2000 m (6500 ft) • Inlet pressures to 65 bar (940 psi)
Features • Pressures to 200 bar (3000 psi) • Temperatures to -170°C (-275°F)
• Designed for use in a cold box • Temperatures from -200°C (-325°F) • Power to 1750 kW (2350 hp)
• Nozzle head with integral • Runaway speed to 8300 rpm
warming chamber Features
• Metal backed PTFE coated bearings • Coffer dam system Features
• Close clearance for high efficiency • Radial or mixed flow hydraulics • Variable (TKW) or fixed (VKW)
• LOX and LIN compatible materials • Low suction velocity can design geometry
conforming to industry standards • Optional axial thrust tilting pad • Externally driven remote and local
• High pressure breakdown bushing bearing configuration controlled variable wickets
• Stand pipe bellows • Stiff shaft design • Optimal isentropic efficiency
• Optional below grade suction flange • API 682 compliant mechanical • Overall improvement of compressor
• Sealing options seal chamber power efficiency
– Dual wet seals • Flanged spacer type coupling • Air cooled generator
– Dry gas seals • Screen-type, non-sparking • Temperature reduction through
– Gas injection labyrinth seal coupling guard liquid expansion
• Reinforced motor stand • Inside drain line • Additional electric generation
• Casing and impeller wear rings • Low vibration
• Reinforced motor stand • Low noise level
• Optional inducer • State-of-the-art gas seal
• Optimum specific speed selection
Other Configurations
• WUC (VS6) double casing multistage

55
(FPD-100) Level 1.qxd 11/8/04 12:32 PM Page 56 Dan K. Snelson Clients:023-FLOWSERVE Pumps:023-Job Files:023-Open Jobs:0832-(FPD-100)

Pleuger SUBM Byron Jackson SUBM


Deep-Well Submersible Deep-Well Submersible
(Water-Filled Design) (Oil-Filled Design)
Vertical – Submersible Motor

Standards Standards
• Flowserve • Flowserve
• CSA, WIMES 3.03, EMV, KTV, CE, • NSF Standard 61 Certification
VDE and other certifications • Certification program accredited by
RvA, Dutch Council for Accreditation
Operating Parameters
• Flows to 4500 m3/h (19 800 gpm) Operating Parameters
• Heads to 800 m (2600 ft) • Flows to 4500 m3/h (19 800 gpm)
• Motor sizes to 5000 kW (6700 hp) • Heads to 800 m (2600 ft)
• Speeds from 200 to 3600 rpm • Motor sizes to 1500 kW (2000 hp)
• Speeds from 1000 to 3600 rpm
Features
• Wet type motors with water tight Features
insulated windings • Oil-filled motors with self-contained
• Dynamically balanced impellers force feed, filtered, cooled oil
• Prefilled motors with food grade circulation system
additives • Vacuum pressure impregnated (VPI)
• Heavy-duty, adjustable, self-aligning epoxy, class F insulation system
thrust bearings • Double-acting thrust bearing system
• Friction welded shafts • Dynamically balanced heavy-duty,
• Non-toxic Class Y winding insulation high efficiency impellers
for potable water services • Variable frequency drive and high
• Variable frequency drive and high temperature options
temperature options • Accredited for water handling services
• Choice of materials • Choice of materials
– Cast iron – Cast iron
– Bronze – Bronze
– Stainless and duplex – Stainless and duplex stainless steels
stainless steels – Reinforced composite
– Reinforced composite • Choice of seals
– Mercury seal
Other Configurations – Double mechanical seal
• Byron Jackson SUBM deep-well – Single, pressurized mechanical seal
submersible (oil-filled design)
Other Configurations
See Bulletin PS-50-3 • Pleuger SUBM deep-well
submersible (water-filled design)

56 See Bulletin PS-50-3


(FPD-100) Level 1.qxd 11/8/04 12:32 PM Page 57 Dan K. Snelson Clients:023-FLOWSERVE Pumps:023-Job Files:023-Open Jobs:0832-(FPD-100)

QMN Solids Handling, MFV Solids Handling MNV Large Capacity,


Wet Pit Solids Handling

Vertical – Slurry and Solids Handling


Standards Standards Standards
• Flowserve • Flowserve • Flowserve

Operating Parameters Operating Parameters Operating Parameters


• Flows to 17 000 m3/h (75 000 gpm) • Flows to 2275 m3/h (10 000 gpm) • Flows to 45 500 m3/h (200 000 gpm)
• Heads to 40 m (130 ft) • Heads to 90 m (300 ft) • Heads to 90 m (300 ft)
• Sizes 250 mm (10 in) to 1200 mm • Sizes to 400 mm (16 in) • Sizes to 1800 mm (72 in)
(48 in)
• Drivers to 950 kW (1250 hp) Features Features
• Solids up to 150 mm (6 in) • Variety of nozzle position options • Variety of nozzle position options
• Direct or independent motor mounting • Direct or independent motor mounting
Features • Minimal shaft deflection • Minimal shaft deflection
• Heavy-duty fabricated discharge head • Oversized shaft and reduced overhang • Oversized shaft and reduced overhang
designed with fabricated flange and • Hardened chrome steel wear rings • Hardened chrome steel wear rings
splitter vane • Stuffing box readily accommodates • Stuffing box accommodates packing
• Symmetrical bowl with twin volute packing or mechanical seals or mechanical seals
• Hydraulically balanced design • Shaft sleeve options • Adjustable wear ring clearance
• Enclosed non-clog impeller – 316 stainless steel • Shaft sleeve options
• Enclosed lineshaft – Hardened chrome steel – 316 stainless steel
• Splitter vanes in the column and • Bearing housing features – Hardened chrome steel
discharge head – Ball or tapered roller bearings • Bearing housing features
• Mechanical seal or soft packing shaft – Integral jacking bolts for wear ring – Tapered roller bearings
sealing options adjustment – Integral jacking bolts for wear
• Hollow or solid shaft motor style – Accessible lubrication points ring adjustment
• 416 SS lineshafts – Accessible lubrication points
• Separate steel soleplate Other Configurations
• Bronze lineshaft bearings • MF horizontal, end-suction Other Configurations
• Suction bell guide vanes • MFV vertical with motor on • MN horizontal, end-suction
• Standard suction bell wear rings separate floor (shown above) • MNF vertical, bottom suction,
• Optional impeller wear rings • MFC vertical with direct connected direct connected motor
motor • MNZ vertical, bottom suction,
See Bulletin PS-40-5 motor on separate floor
See Bulletin PS-10-3 • MNC vertical with base elbow,
direct connected motor
• MNV vertical with base elbow,
motor on separate floor
(shown above)

See Bulletin PS-10-4 57


(FPD-100) Level 1.qxd 11/8/04 12:32 PM Page 58 Dan K. Snelson Clients:023-FLOWSERVE Pumps:023-Job Files:023-Open Jobs:0832-(FPD-100)

FRBHJC MJ and MJC Hard Metal RJ and RJC Rubber Lined


Cantilever Sump Slurry Sump Slurry Sump
Vertical – Slurry and Solids Handling

Standards Standards Standards


• Flowserve • Flowserve • Flowserve

Operating Parameters Operating Parameters Operating Parameters


• Flows to 2700 m3/h (12000 gpm) • Flows to 225 m3/h (1000 gpm) • Flows to 225 m3/h (1000 gpm)
• Heads to 100 m (325 ft) • Heads to 30 m (100 ft) • Heads to 30 m (100 ft)
• Temperatures to 150°C (300°F) • Pressures to 10 bar (150 psi) • Pressures to 10 bar (150 psi)
• Speeds to 1780 rpm • Temperatures to 110°C (225°F) • Temperatures to 110°C (225°F),
• Solids from 2% to 70% by weight depending on material
Features • Speeds to 1780 rpm • Solids from 2% to 70% by weight
• True stiff shaft cantilever design, • Speeds to 1780 rpm
without bottom bearing or Features
flushing water • MJ - Submerged bearing and Features
• Steep head capacity lineshaft design for deep setting • RJ - Submerged bearing and lineshaft
• Semi-open, full vane impeller with • MJC - Cantilever design with no design for deep setting
back pump-out vanes submerged bearings • RJC - Cantilever design with no
• Stuffing box accommodates multiple • Abrasion and corrosion-resistant high submerged bearings
seal types chrome iron concentric casing • Radially split casing with anti-
• Direct coupled or V-belt driven • Integrally cast straightening vanes prerotation vanes in suction nozzle
• Extra heavy-duty alloy steel shaft in the suction nozzle • Casing liners pressure molded
• Closed impeller with pump-out vanes on steel backing plates
Other Configurations on front and rear shrouds – Multiple materials available
• FRBH heavy-duty paper stock • MJ has fluted “Cutlass” rubber • Pressure molded rubber closed
and process bearings impeller with pump-out vanes on front
• FRBHJ vertical lineshaft sump • MJC has “Thordon” restriction and rear shrouds
bushing • RJ has fluted “Cutlass” rubber
See Bulletin PS-10-16 • Directly coupled or V-belt driven bearings
• Options • RJC has “Thordon” restriction
– Hard metal expeller bushing
– Open and recessed impellers • Directly coupled or V-belt driven
– Choice of materials • Options
– Hard metal expeller
Other Configurations – Choice of liner materials
• M horizontal hard metal
abrasive slurry Other Configurations
• R horizontally split rubber
See Bulletin PS-10-19 lined slurry

58 See Bulletin PS-10-18


(FPD-100) Level 1.qxd 11/8/04 12:32 PM Page 59 Dan K. Snelson Clients:023-FLOWSERVE Pumps:023-Job Files:023-Open Jobs:0832-(FPD-100)

Terra-Titan MSX Solids Handling,


Cantilever Sump Submersible

Vertical – Slurry and Solids Handling


Standards Standards
• Flowserve • Flowserve

Operating Parameters Operating Parameters


• Flows to 250 m3/h (1100 gpm) • Flows to 4550 m3/h (20 000 gpm)
• Heads to 45 m (150 ft) • Heads to 90 m (300 ft)
• Pressures to 5 bar (70 psi) • Sizes to 500 mm (20 in)
• Temperatures to 100°C (212°F) • Motor to 300 kW (400 hp)
• Sizes from 40 mm (1.5 in) • Solids handling to 80 mm
to 125 mm (5.0 in) (3 in) spherical
• Sump depths from 700 mm
(28 in) to 1800 mm (72 in) Features
• High efficiency hydraulics
Features • EPACT rated motor
• One-piece suspended, oversized • Spike-resistant windings
cantilever shaft construction • Class H rated insulation system
• Interchangeable urethane or hard • Dynamically balanced shaft
metal wetted parts and rotor
• Concentric casing design • Available configurations
• Double suction, hydraulically – MSX Series 1 – Sizes to
balanced open impeller 150 mm (6 in)
• External impeller adjustment – MSX Series 2/3 – Sizes to
• Renewable Terraprene urethane 500 mm (20 in)
shaft sleeve • Mounting options
• Greased for life, heavy-duty, – Wet pit
self-aligning roller bearings – Dry pit
• Upper and lower strainers – Transportable
• Run-dry capability
• ANSI and ISO configurations See Bulletin PS-50-2
• Portable
• Lifting lugs
• Rigid motor mount pivot bar
• Available bottom suction tailpipe
• Multiple drive options

See Bulletin PS-10-7

59
(FPD-100) Level 1.qxd 11/8/04 12:33 PM Page 60 Dan K. Snelson Clients:023-FLOWSERVE Pumps:023-Job Files:023-Open Jobs:0832-(FPD-100)

CPXV (VS4) Chemical ESP2 Vertical Immersion PolyChem VGRP Vertical,


Sump Sump Engineered Polymer
Composite Sump
Vertical – Sump

Standards Standards Standards


• API 610 (VS4), 8th edition • Flowserve • Flowserve
• ISO 5199
Operating Parameters Operating Parameters
Operating Parameters • Flows to 800 m3/h (3500 gpm) • Flows to 565 m3/h (2500 gpm)
• Flows to 1400 m3/h (6160 gpm) • Heads to 90 m (300 ft) • Heads to 110 m (350 ft)
• Heads to 250 m (820 ft) • Pressures to 12 bar (175 psi) • Pressures to 17 bar (250 psi)
• Pressures to 25 bar (365 psi) • Temperatures to 180°C (350°F) • Temperatures from -30°C (-20°F)
• Temperatures from -40°C (-40°F) to 90°C (200°F)
to 350°C (660°F) Features
• Speeds to 4700 rpm • Optimized lineshaft bearing design Features
to API 610 spacing requirements • Glass reinforced vinyl ester
Features • Double row external thrust bearings • Unitized casing with integrally
• Heavy-duty casing with multi-ribbed • Single and duplex configurations molded, fully gusseted suction and
discharge flange • Flanged discharge discharge flanges
• High efficiency, low NPSHR, • Large basket strainer • Externally adjustable,
precision cast open impeller • Industry standard “TCV” motors semi-open impeller
• Column lengths to 10 m (33 ft) • Lubrication options • Shaft and bearing system operates
• Heavy-duty, sealed for life, double – Product lube design for well below the first critical speed
thrust bearings clear liquids • Self-lubricated or external
• Options – Dual particle separator for flush bearings
– Spacer or flexible coupling light solids • Single-piece, lightweight, filament-
– Rectangular or circular soleplates – Grease lubrication wound, reinforced fiberglass
– Jacketed body • Mounting plate sealing options composite column
– Recessed impeller – Vapor tight • Single and duplex configurations
– Oil lubrication – Vapor proof • Full basket strainer
– Non-spacer coupling – Pressurized design • NEMA in-line motor
– Suction strainer • Options • Fiberglass mounting plate
• CE marked and compliant with – Upper stuffing box • Tapered polygon impeller drive
applicable European directives, – Sealing ring • Pull-out bearing retainers
such as ATEX – Suction tailpipes • Level controls
– Level controls • Choice of shaft metallurgy
Other Configurations
• CPX ISO standard See Bulletin PS-10-24 Other Configurations
• CPXVR recessed impeller sump • GRP engineered polymer composite

See Bulletin PS-10-30 See Bulletin PS-10-17

60
(FPD-100) Level 1.qxd 11/8/04 12:49 PM Page 61 Dan K. Snelson Clients:023-FLOWSERVE Pumps:023-Job Files:023-Open Jobs:0832-(FPD-100)

Drain-Titan VSMP Standard Motor ECPJ (VS4 and VS5)


Double Suction, Sump
Urethane Lined Sump

Vertical – Sump
Standards Standards Standards
• Flowserve • Flowserve • API 610 (VS4 and VS5), latest edition

Operating Parameters Operating Parameters Operating Parameters


• Flows to 160 m3/h (700 gpm) • Flows to 135 m3/h (600 gpm) • Flows to 500 m3/h (2200 gpm)
• Heads to 40 m (130 ft) • Heads to 70 m (220 ft) • Heads to 150 m (500 ft)
• Pressures to 4 bar (55 psi) • Pressures to 12 bar (175 psi) • Pressures to 16 bar (230 psi)
• Sizes from 40 mm (1.5 in) • Temperatures from -40°C (-40°F) • Temperatures to 350°C (660°F)
to 100 mm (4 in) to 120°C (250°F) • 42 sizes available
• Solids to 15 mm (0.5 in)
Features Features
Features • Glass reinforced polymer, high • Lineshaft (VS4) and cantilever (VS5)
• Double suction, urethane coated efficiency, semi-open or closed configurations available
wet-end impellers standard • Four impeller designs to suit
• Robust, integral unit construction • Industry standard NEMA motors hydraulic requirements
• Large diameter, stiff cantilever • Stainless steel, self-aligned – Closed multivane impeller with
drive shaft mechanical seal front wear rings and back vanes
• No submerged bearings or seals • Back pull-out design – Closed multivane impeller with
• Double sided impeller with • Clamp-type mounting plate front and rear wear rings
pre-set clearance • Options – Open multivane impeller with
• Keyed and bored shaft coupling – Cast iron, bronze or 316 SS back vanes
• Standard single lip oil seal impellers – Free flow impeller with back vanes
• Urethane lined, slotted outlet – Stub shaft design • Multiple shaft sealing options
pipe flange – V-ring
• Grease lubricated, single row, Other Configurations – Throttle bushing
deep groove ball bearings • SMP standard motor pump – Lip seal with grease-filled
• No priming required • SMX non-metallic standard stuffing box
• Run-dry capability motor pump – Soft packing
• API 682 seal chamber accommodates
See Bulletin PS-10-7 See Bulletin PS-10-26 multiple seal types
• Column lengths to 6 m (22 ft)
– Suction pipe available
• Choice of API materials
• NACE MR0175 materials available
• Internal or external bearing flushing
• Bearing cooling
• Suction strainer

61
(FPD-100) Level 1.qxd 11/8/04 12:49 PM Page 62 Dan K. Snelson Clients:023-FLOWSERVE Pumps:023-Job Files:023-Open Jobs:0832-(FPD-100)
(FPD-100) Level 1.qxd 11/8/04 12:49 PM Page 63 Dan K. Snelson Clients:023-FLOWSERVE Pumps:023-Job Files:023-Open Jobs:0832-(FPD-100)

Rotary Pumps

Rotary Pumps
Gear
GR Double Helical 64
GAX Double Helical 64
Gearex Double Helical 64

Screw
MPP Multiphase 65
Sier-Bath Two-Screw 65

63
(FPD-100) Level 1.qxd 11/8/04 12:49 PM Page 64 Dan K. Snelson Clients:023-FLOWSERVE Pumps:023-Job Files:023-Open Jobs:0832-(FPD-100)

GR Double Helical, GAX Series Cast Iron, Gearex Double Helical,


Gear Double Helical, Gear Timed Gear
Rotary – Gear

Standards Standards Standards


• Flowserve • Flowserve • Flowserve

Operating Parameters Operating Parameters Operating Parameters


• Flows to 275 m3/h (1200 gpm) • Flows to 30 m3/h (120 gpm) • Flows to 180 m3/h (800 gpm)
• Pressures to 35 bar (500 psi) • Pressures to 17 bar (250 psi) • Pressures to 24 bar (350 psi)
• Temperatures to 350°C (650°F) • Temperatures to 175°C (350°F) • Temperatures from -50°C (-60°F)
• Speeds to 1800 rpm • Speeds to 1800 rpm to 450°C (850°F)
• Viscosities to 100 000 ssu • Viscosities to 25 000 ssu • Viscosities to 1 million ssu

Features Features Features


• Double helical, herringbone gears • Double helical, herringbone gears • Double helical, herringbone gears
• Quiet, pulse-free flow • Quiet, pulse-free flow • Quiet, pulse-free flow
• High speed pump capability • High speed pump capability • Timing gears
• Between bearing design – Off-the-shelf motors • Between bearing design
• Hydraulically balanced design • Between bearing design • Heavy-duty, double row roller
• Stuffing box accommodates packing • Self-lubricated babbitted carbon bearings
or mechanical seals sleeve bearings standard • Direct coupled
• High-capacity, double row – Bronze bearings optional • Options
roller bearing • Hydraulically balanced design – Water cooled bearings
• Self-priming – No thrust bearings – Steam or water jacketed bodies
• Run dry capability • Convertible stuffing box accommo- – Vertical mounting configuration
• Low NPSHR dates packing or mechanical seals – Mechanical seals
• Back pull-out design • Threaded ports – Lantern rings
• Options • Back pull-out design – Shaft slingers
– Mechanical seal • Available integral safety relief valve – Split bearing brackets
– Direct V-belt drive • Multiple mounting configurations – Flange mounting brackets
– Extra deep jacketed stuffing box – Foot mounting (GAS) - standard – Jackshafts for V-belt drives
– Jacketed body – Flange mounting (GAF)
– Babbitted carbon sleeve bushing – Close coupled (GAC)
– INSUROCK wearplates
– Integral safety relief valve Other Configurations
• GSX series stainless steel, double
See Bulletin PS-60-3 helical, rotary gear pumps

64
(FPD-100) Level 1.qxd 11/8/04 12:49 PM Page 65 Dan K. Snelson Clients:023-FLOWSERVE Pumps:023-Job Files:023-Open Jobs:0832-(FPD-100)

MPP Multiphase Screw Sier-Bath Two-Screw

Rotary – Screw
Standards Standards
• Flowserve • Flowserve
• API 682 seal chamber • API 682 seal chamber

Operating Parameters Operating Parameters


• Flows to 1520 m3/h (6700 gpm) • Flows to 3400 m3/h (15 000 gpm)
• Pressures to 100 bar (1450 psi) • Pressures to 240 bar (3500 psi)
• Temperatures from -50°C (-60°F) • Temperatures from -50°C (-60°F)
to 150°C (300°F) to 450°C (850°F)
• Viscosities to 5 million ssu • Speeds to 1800 rpm
• Multiphase pumping to 100% GVF • Viscosities to 200 million ssu
(gas void fractions) • Slurry concentrations to 70%
by weight
Features • Multiphase pumping to 100% GVF
• Non-contacting design with (gas void fractions)
one-piece pump shafts
• Three pumping locks for varying Features
gas-to-liquid ratios • Positive displacement
• Through bolt bracket design timed two-screw
• API 682 seal chamber with split • Double suction design
brackets accommodates single • Versatile API 682 compliant
and double cartridge seals stuffing box design
• Smooth, pulse-free flow • Integral or pinned screw elements
• Slow speed operation • Spur-tooth timing gears
• Double suction design with low • Chrome-plated pump bores
NPSH capability • Options
• AGMA 11 spur timing gears – Fully external bearings and
• Wide range of pitch choices for timing gears
operation without speed reducers – Internal bearings and timing gears
• Optional hard coating for body – Temperature control packages
bores and screws – Hopper-top construction
– Vertical barge configuration
– Choice of materials

65
(FPD-100) Level 1.qxd 11/8/04 12:49 PM Page 66 Dan K. Snelson Clients:023-FLOWSERVE Pumps:023-Job Files:023-Open Jobs:0832-(FPD-100)
(FPD-100) Level 1.qxd 11/8/04 12:49 PM Page 67 Dan K. Snelson Clients:023-FLOWSERVE Pumps:023-Job Files:023-Open Jobs:0832-(FPD-100)

Reciprocating
Pumps

YHT and HS 68

Reciprocating Pumps
VTE, VQE and V 68

67
(FPD-100) Level 1.qxd 11/8/04 12:49 PM Page 68 Dan K. Snelson Clients:023-FLOWSERVE Pumps:023-Job Files:023-Open Jobs:0832-(FPD-100)

YHT and HS Multiplunger, VTE, VQE and V


Horizontal Reciprocating Vertical Reciprocating
Reciprocating

Standards Standards
• Flowserve • Flowserve

Performance Performance
• 75 mm (3 in) to 250 mm • 140 mm (5.5 in) to
(10 in) stroke 225 mm (9 in) stroke
• Flows to 775 m3/h (3400 gpm) • Flows to 1140 m3/h (5000 gpm)
• Power to 2560 kW (3430 hp) • Power to 3450 kW (4625 hp)
• Standard pressures to 554 bar • Standard pressures to 619 bar
(8030 psi) (8975 psi)
• Custom pressures to 2070 bar • Custom pressures to 2070 bar
(30 000 psi) (30 000 psi)
• Temperatures from -40°C (-40°F) • Temperatures from -40°C (-40°F)
to 350°C (650°F) to 350°C (650°F)
• Speeds to 530 rpm • Speeds to 360 rpm

Features Features
• Self-aligning plungers • Outboard packed inverted design
• Sectionalized fluid end components • Easily accessible stuffing box
• Fully enclosed power end with • Integrated suction and discharge
generous oil reservoir manifold
• Independent crosshead • Complete separation of liquid end
extension rod from power end
• Integrally cast and precision machined • Cartridge type plate valve
cylindrical crosshead guides • Spherical feature for
• Triple lip seal at the crosshead plunger alignment
extensions • Power-end maintenance
• Fully reversible crankshaft for V-belt inspection covers
drive or direct coupling • Forced feed lubrication
• Stuffing box assemblies individually
bolted to fluid cylinder
• Four precision-type main bearings
• Splash-type or full pressure
lubrication system
• Threaded primary drain
• Options
– Overhead motor mounting
– Spring loaded stuffing box
68 – Discharge pulsation dampeners
(FPD-100) Level 1.qxd 11/8/04 12:49 PM Page 69 Dan K. Snelson Clients:023-FLOWSERVE Pumps:023-Job Files:023-Open Jobs:0832-(FPD-100)

69
(FPD-100) Level 1.qxd 11/8/04 12:49 PM Page 70 Dan K. Snelson Clients:023-FLOWSERVE Pumps:023-Job Files:023-Open Jobs:0832-(FPD-100)
(FPD-100) Level 1.qxd 11/8/04 1:13 PM Page 71 Dan K. Snelson Clients:023-FLOWSERVE Pumps:023-Job Files:023-Open Jobs:0832-(FPD-100)

Specialty Pumps

Nuclear

Specialty Pumps
DFSS and DVSS
Single Stage 72
CAM Multistage 72
WDF Vertical 72
CN Diffuser Casing 73
DVSR Volute Case 73

Cryogenic
VPC Cryogenic 74
WUC-LNG Cryogenic 74
VKW and TKW
Liquid Expander 74

Other
TKW Hydroturbine 75
BSV and BCV
Concrete Volute 75
Barge 75

71
(FPD-100) Level 1.qxd 11/8/04 1:14 PM Page 72 Dan K. Snelson Clients:023-FLOWSERVE Pumps:023-Job Files:023-Open Jobs:0832-(FPD-100)

DFSS and DVSS Nuclear CAM Nuclear WDF Nuclear


Radially Split, Between Bearings, Vertical Single Stage
Single Stage Radially Split, Multistage
Specialty – Nuclear

Standards Standards Standards


ASME Section III, Class 1 Nuclear • ASME Section III, Class 2 Nuclear • ASME Section III, Class 2 and 3
Nuclear
Operating Parameters Operating Parameters
• Flows to 24 500 m3/h (108 000 gpm) • Flows to 45 m3/h (200 gpm) Operating Parameters
• Heads to 250 m (815 ft) • Heads to 1920 m (6300 ft) • Flows to 900 m3/h (4000 gpm)
• Pressures to 170 bar (2500 psi) • Pressures to 200 bar (3000 psi) • Heads to 245 m (800 ft)
• Temperatures to 300°C (580°F) • Temperatures to 120°C (250°F)
• Speeds to 1800 rpm Services
• Power rating to 9400 kW (12 600 hp) Services • Containment spray
• CVCS charge • Low pressure safety injection
Services • Safety injection • Residual heat removal
• Primary coolant • Control rod drive • Pressurized and boiling water reactors
• Reactor coolant for N-stamp safety applications
• Primary heat transport Features
• Multistage, double casing design Features
Features • Unique, compact design patented • Vertical, single stage design
• Fourth generation design modular impellers • Bottom suction, horizontal discharge
• One-piece cast pump casing – Low-flow stability and reliability • Forged diffuser casing design
• Double volute design case for BWR over a wide range of flows • Optimized hydraulic performance
and PHWR – No surging or pulsations • Unique spacer coupling design
• Diffuser with torus-type design • Ball-ball construction • Mechanical seal replacement without
casing for PWR • Dry disk spacer coupling motor or casing cover removal
• Upgraded rotating element • Flanged axial thrust-balancing device • Upgraded rotor design
– One-piece welded shaft-impeller- • Modularized assembly and – Radial bearing located between
journal assembly disassembly may be conducted coupling and seal
– Fully machined and balanced without the use of a torch – Reduced shaft deflection
as single rotating unit • Forged barrel with no – Improved pump and mechanical
• Hydrostatic-pressurized radial bearing attachment welds seal life and reliability
– Operates submerged in radioactive • Cartridge mechanical seals with • Cartridge mechanical seal
system water at loop temperature no attachment welds • Reduced assembly time
of approximately 300°C (580°F)
See Bulletin FPD-2 See Bulletin FPD-2
See Bulletin FPD-2

72
(FPD-100) Level 1.qxd 11/8/04 1:14 PM Page 73 Dan K. Snelson Clients:023-FLOWSERVE Pumps:023-Job Files:023-Open Jobs:0832-(FPD-100)

CN Nuclear DVSR Nuclear


Radially Split, Diffuser Radially Split, Volute
Casing, Single Stage Casing, Single Stage

Specialty – Nuclear
Standards Standards
• ASME Section III, Class 3 Nuclear • ASME Section III, Class 3 Nuclear

Operating Parameters Operating Parameters


• Flows to 5065 m3/h (22 300 gpm) • Flows to 5065 m3/h (22 300 gpm)
• Heads to 800 m (2630 ft) • Heads to 800 m (2630 ft)
• Pressures to 87 bar (1265 psi) • Pressures to 87 bar (1265 psi)
• Temperatures to 200°C (400°F) • Temperatures to 200°C (400°F)
• Power to 11 200 kW (15 000 hp) • Power to 11 200 kW (15 000 hp)
• Speeds to 6000 rpm • Speeds to 6000 rpm

Services Services
• Reactor and steam feedwater • Reactor and steam feedwater

Features Features
• Diffuser casing configuration • Cast volute casing configuration
• Forged barrel • High speed pump design
• High speed pump design • Double suction impeller
• Double suction impeller • Centerline mounted
• Centerline mounted • Pressure breakdown bushing or
• Pressure breakdown bushing or conventional mechanical service
conventional mechanical service
See Bulletin FPD-2
See Bulletin FPD-2

73
(FPD-100) Level 1.qxd 11/8/04 1:14 PM Page 74 Dan K. Snelson Clients:023-FLOWSERVE Pumps:023-Job Files:023-Open Jobs:0832-(FPD-100)

VPC Cryogenic (VS6) WUC-LNG Cryogenic (VS6) VKW and TKW Cryogenic
Vertical, Double Casing, Vertical, Double Casing, Liquid Expander (VS6)
Multistage Multistage Double Casing, Multistage,
Electric Generator
Specialty – Cryogenic

Standards Standards Standards


• API 610 (VS6), latest edition • API 610 (VS6), latest edition • API 610 (VS6), latest edition
• ASME Sections VIII and IX • ASME Sections VIII and IX • ASME Sections VIII and IX
• German Pressure Vessel • Shell DEP
Operating Parameters Association (AD) • NEMA MG1, latest edition
• Flows to suit site requirements • British Standard BS 5500 • Hazardous area classification (EExe)
• Heads to suit site requirements • Compliance with Pressure Equipment to the site country
• Discharge pressures to 148 bar Directive 97/23/EC
(2160 psi) Operating Parameters
• Temperatures from -200°C (-325°F) Operating Parameters • Expander flows to 1800 m3/h
to -45°C (-50°F) • Flows to 3000 m3/h (13 000 gpm) (7900 gpm)
• Heads to 2000 m (6500 ft) • Inlet pressures to 65 bar (940 psi)
Features • Pressures to 200 bar (3000 psi) • Temperatures to -170°C (-275°F)
• Designed for use in a cold box • Temperatures from -200°C (-325°F) • Power to 1750 kW (2350 hp)
• Nozzle head with integral to -45°C (-50°F) • Runaway speed to 8300 rpm
warming chamber
• Metal backed PTFE coated bearings Features Features
• Close clearance for high efficiency • Coffer dam system • Variable (TKW) or fixed (VKW)
• LOX and LIN compatible materials • Radial or mixed flow hydraulics geometry
conforming to industry standards • Low suction velocity can design • Externally driven remote and local
• High pressure breakdown bushing • Optional axial thrust tilting pad controlled variable wickets
• Stand pipe bellows bearing configuration • Optimal isentropic efficiency
• Optional below grade suction flange • Stiff shaft design • Overall improvement of compressor
• Sealing options • API 682 compliant mechanical power efficiency
– Dual wet seals seal chamber • Air cooled generator
– Dry gas seals • Flanged spacer type coupling • Temperature reduction through
– Gas injection labyrinth seal • Screen-type, non-sparking liquid expansion
• Reinforced motor stand coupling guard • Additional electric generation
• Inside drain line • Low vibration
• Casing and impeller wear rings • Low noise level
• Reinforced motor stand • State-of-the-art gas seal
• Optional inducer • Optimum specific speed selection

Other Configurations
• WUC (VS6) double casing, multistage

74
(FPD-100) Level 1.qxd 11/8/04 1:14 PM Page 75 Dan K. Snelson Clients:023-FLOWSERVE Pumps:023-Job Files:023-Open Jobs:0832-(FPD-100)

TKW Vertical BSV and BCV Vertical Barge Unloading


Hydroturbine Concrete Volute

Specialty – Other
Standards Standards Standards
• Flowserve • Flowserve • Flowserve

Operating Parameters Operating Parameters Operating Parameters


• For sites of 50 kW (65 hp) • Flows to 115 000 m3/h (500 000 gpm) • Flows to 1320 m3/h (5800 gpm)
to 3000 kW (4000 hp) • Heads to 22 m (72 ft) • Heads to 185 m (600 ft)
• 50 kW (65 hp) to 1000 kW (1350 hp) • Temperatures from -30°C (-20°F)
per unit Features to 230°C (450°F)
• 12 m (40 ft) to 45 m (150 ft) • Removable metallic pump pull-out
per stage unit within a concrete volute Features
• Suction bell connected to preformed • Pollution prevention design
Features intake suction box • Discharge head with access ports
• Semi-axial flow runner • Open mixed flow (BSV) and closed • Rabbeted fit motor shaft
• Adjustable rotor clearance mixed flow (BCV) impeller options to headshaft
• Wicket gates, adjustable • Bearings and sealing systems • 1.5 m (5 ft) column pieces with
during operation easily accessible integrally fabricated bearing support
• Optimized draft tube design • Prefabricated concrete segments • Automatic stuffing box bleed-off
• Bearing options • Highly corrosion and erosion resistant and valved drain line
– Self-lube, open shaft • Liquidyne shaft seal • Special low NPSH priming
– Oil-lube, enclosed shaft • Inflatable static seal stage impeller
• Control options • Semi-open series stage impeller
– Manual See Bulletin PS-40-1 • Automatic air separation chamber
– Automatic with continuous seal
– Alternative mechanisms
• Materials
– Stainless steel shaft
– Nickel-aluminum bronze wicket
gates
– Nickel-aluminum bronze runner
and runner case

See Bulletin PS-90-1

75
(FPD-100) Level 1.qxd 11/8/04 1:14 PM Page 76 Dan K. Snelson Clients:023-FLOWSERVE Pumps:023-Job Files:023-Open Jobs:0832-(FPD-100)

76
(FPD-100) Level 1.qxd 11/8/04 1:14 PM Page 77 Dan K. Snelson Clients:023-FLOWSERVE Pumps:023-Job Files:023-Open Jobs:0832-(FPD-100)

Additional
Information

(% of BE

Technical Information
Reference Sources 78
1K3x2V-7 3500 25 Global Engineered
2K3x2V-10 3500 30 Services and Support 79
2K4x3V-10 3500 33 Training 80
2K3x2V-13 3500 50 Other Flowserve
K4x3V-13/11* 3500 50 Products 81
2K6 4V 13 1780 50 Product Index 82

77
77
(FPD-100) Level 1.qxd 11/8/04 1:14 PM Page 78 Dan K. Snelson Clients:023-FLOWSERVE Pumps:023-Job Files:023-Open Jobs:0832-(FPD-100)

Reference Sources
Reference Sources

Pump Industry Standards Pump Engineering Manual


To learn about industry standards This publication is devoted to explaining
pertaining to the design and centrifugal pump principles. It covers
performance of pumps contact the the basics from application analysis
following organizations: and affinity laws through hydraulics
and mechanical phenomena to
• American Petroleum Institute (API) troubleshooting.
www.api.org
• American Society of Mechanical To obtain a copy of the Pump
Engineers (ASME – ANSI) Engineering manual visit:
www.asme.org www.flowserve.com.
• American Society of Testing and
Materials (ASTM)
www.astm.org
• European Sealing Association (ESA)
www.europeansealing.com PROS+
• Europump PROS+ proposal and order system is
www.europump.org the most comprehensive and user
• Deutsches Institut für Normung (DIN) friendly pump selection program in the
www.2.din.de/ industry. This software ensures correct
• Fluid Sealing Association (FSA) sizing and selection of Flowserve
www.fluidsealing.com pumps to best suit your process
• Hydraulic Institute (HI) application needs.
www.pumps.org
• International Standards Organization PROS+ is available from your local
(ISO) sales representative or on-line at
www.flowserve.com.
www.iso.ch/iso/en/ISOonline.openpage

Cameron Hydraulic Data


First published in 1926 and now in its
19th edition, the Cameron Hydraulic
Data book is an indispensable aid to
engineers involved with the specification,
selection and application of pumping
equipment. This comprehensive
reference tool includes:
• hydraulic principles
• formulae
• friction
• liquids
• steam and electrical data
• pipe flanges and fittings
• metric conversions

To obtain a copy of the Cameron


Hydraulic Data book visit:
www.cameronbook.com.

78
(FPD-100) Level 1.qxd 11/8/04 1:14 PM Page 79 Dan K. Snelson Clients:023-FLOWSERVE Pumps:023-Job Files:023-Open Jobs:0832-(FPD-100)

Global
Engineered Services
and Support

Total Cost Reduction Service Dedication Business Partner

Global Engineered Services and Support


Flowserve Engineered Services is Flowserve partners with customers to
Asset Management focused on providing customers with respond to the dynamic business condi-
Product Life Cycle uncompromising service and support, tions that affect them. Flowserve will
Performance Re-rates where and when needed. Dedicated to work with customers to drive efficiency,
delivering the highest quality support, maximize throughput and control
Site Diagnostics Engineered Services integrates its process quality. Whether user needs
Repair Services extensive pump and materials involve on-site technical assistance or
engineering knowledge with creative broader project planning with full turnkey
Energy Management service solutions. Engineered Services responsibility, Flowserve Engineered
Spare Parts fully understands the business chal- Services will deliver professional,
lenges facing customers and is prepared reliable results.
Maintenance Contracts
to manage solutions to succeed as
Materials Upgrades a team.
Turnkey Services
A worldwide network of service and
Field Repairs repair centers staffed by highly skilled
Installation engineers and technicians is available
around the clock, seven days a week
Project Supervision to respond to customer queries, to
Commissioning evaluate and troubleshoot problems
Equipment Upgrades and to provide reliable solutions.

Condition Monitoring
Systems Analysis
Field Machining

79
79
(FPD-100) Level 1.qxd 11/8/04 1:15 PM Page 80 Dan K. Snelson Clients:023-FLOWSERVE Pumps:023-Job Files:023-Open Jobs:0832-(FPD-100)

Training
Training

Flowserve Educational Services (FES)


The mission of FES is to provide
companies around the world with
innovative and comprehensive training
focused on effective solutions. A wide
range of technical and maintenance
training courses is available to deepen
participants’ understanding of fluid
management systems and critical
equipment. The objective is to teach
best practices to maximize reliability
and minimize total life cycle cost.

Learning Resource Center (LRC)


Located in Irving, Texas, the LRC
contains state-of-the-art classrooms
and hydraulics labs for both theoretical
and practical instruction.

On-Site Training
On-site training programs are tailored
to the people, equipment and process
at the plant level. This is a convenient,
time-efficient way of training employees
on the equipment they use day
in and day out.

For more information about


Flowserve Educational Services visit
www.flowserve.com.

80
80
(FPD-100) Level 1.qxd 11/8/04 1:15 PM Page 81 Dan K. Snelson Clients:023-FLOWSERVE Pumps:023-Job Files:023-Open Jobs:0832-(FPD-100)

Providing Complete
Fluid Motion
Control Equipment
and Services

Flowserve Seals Flowserve Valves

Other Flowserve Divisions


Flowserve manufactures and markets Flowserve has the systems, products
highly engineered mechanical shaft and experience to help processes run
seals for containing corrosive, volatile, smarter, safer and more efficiently.
abrasive, precious or flammable fluid. With the industry’s most complete
They are used on pumps and other range of valves, actuators, positioners
rotating equipment. controls, switches and steam systems,
Flowserve provides customers a one-
The complete seal line includes stop solution for their flow control
cartridge, dry-running, metal or needs.
elastomer bellows, split and zero
emission gas barrier seals. Offering With comprehensive research and
innovative seal design and service on development, engineering and global
demand, Flowserve is committed to support, Flowserve Valves can offer
the development of new technologies applications solutions from simple
to further reduce maintenance and isolation service to intelligent process
operating costs for its customers. control.

To learn more about Flowserve Valves


and Seals, visit www.flowserve.com.

81
81
(FPD-100) Level 1.qxd 11/8/04 1:15 PM Page 82 Dan K. Snelson Clients:023-FLOWSERVE Pumps:023-Job Files:023-Open Jobs:0832-(FPD-100)

Product Index
Product Index

A HPXM. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 24 QLQC . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 54
AFV . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 53 HS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 68 QMN. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 57
HSB . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 47
B HSO . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 48 R
Barge . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 75 HWM . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 26 R . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 30
BCV . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 75 HWM2 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 26 RJ . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 31, 58
BSV . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 75 HWX. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 26 RJC. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 31, 58
Byron Jackson SUBM (Oil-Filled Design) . . . . 56
L S
C LC . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 32 Sier-Bath Two-Screw . . . . . . . . . . . . . . . . . . . 65
CAM . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 72 LLR . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 41 SMP . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 36
CHTA . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 47 LNGT . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 41 SMX . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 37
CN . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 73 LNN . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 40 SUBM (see Bryon Jackson SUBM or Pleuger SUBM)
CPX . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 20 LR . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 40
CPXM . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 21 LRV . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 40 T
CPXP . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 20 Terra-Titan . . . . . . . . . . . . . . . . . . . . . . . . 31, 59
CPXR . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 20 M Titan Slurry . . . . . . . . . . . . . . . . . . . . . . . . . . 31
CPXS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 21 M . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 30 TKW Cryogenic Liquid Expander. . . . . . . . 55, 74
CPXV . . . . . . . . . . . . . . . . . . . . . . . . . . . . 21, 60 Mark 3 ANSI Standard . . . . . . . . . . . . . . . . . . 18 TKW Vertical Hydroturbine . . . . . . . . . . . . . . 75
CS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 45 Mark 3 In-Line . . . . . . . . . . . . . . . . . . . . . . . . 19
CSB . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 47 Mark 3 Lo-Flo. . . . . . . . . . . . . . . . . . . . . . . . . 18 U
Mark 3 Recessed Impeller . . . . . . . . . . . . . . . 19 UZDL . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 42
D Mark 3 Unitized Self-Primer . . . . . . . . . . . . . . 18
D800 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 35 MEN . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 35 V
DFSS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 72 MF . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 34 V . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 68
DMX . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 42 MFV . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 57 VCT . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 53
Drain-Titan . . . . . . . . . . . . . . . . . . . . . . . . 35, 61 MJ . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 30, 58 VKW . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 55, 74
DSVP . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 28 MJC . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 30, 58 VOA . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 53
DVSH . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 42 MN . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 34 VOP . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 53
DVSR . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 73 MNV . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 57 VPC . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 54
DVSS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 72 MND. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 32 VPC Cryogenic . . . . . . . . . . . . . . . . . . . . . 55, 74
MNR. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 32 VQE . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 68
E MPP . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 65 VSMP . . . . . . . . . . . . . . . . . . . . . . . . . . . . 36, 61
ECPJ. . . . . . . . . . . . . . . . . . . . . . . . . . . . . 37, 61 MSP . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 28 VTE. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 68
ERPN . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 25 MSP2 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 28 VTP . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 52
ERPN-Mag . . . . . . . . . . . . . . . . . . . . . . . . . . . 25 MSX . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 34, 59
ESP2. . . . . . . . . . . . . . . . . . . . . . . . . . . . . 37, 60 W
N W . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 27
F NM . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 44 WCC . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 48
F-Line. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 36 WD. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 44
FRBH . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 33 P WDF . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 72
FRBHJC . . . . . . . . . . . . . . . . . . . . . . . . . . 33, 58 PHL . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 24 WDX. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 44
PHL-MAG . . . . . . . . . . . . . . . . . . . . . . . . . . . . 25 WIK . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 48
G Pleuger SUBM (Water Filled Design) . . . . . . 56 WM . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 27
GAX . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 64 Polybase . . . . . . . . . . . . . . . . . . . . . . . . . . . . 23 WM2 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 27
Gearex . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 64 PolyChem GRP . . . . . . . . . . . . . . . . . . . . . . . 22 WNC-HP . . . . . . . . . . . . . . . . . . . . . . . . . . . . 46
GR . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 64 PolyChem M-Series . . . . . . . . . . . . . . . . . . . . 23 WNC. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 46
GT . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 41 PolyChem S-Series . . . . . . . . . . . . . . . . . . . . 22 WUC. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 54
Guardian . . . . . . . . . . . . . . . . . . . . . . . . . . . . 19 PolyChem VGRP . . . . . . . . . . . . . . . . . . . 22, 60 WUC-LNG . . . . . . . . . . . . . . . . . . . . . . . . . 55, 74
Polyshield . . . . . . . . . . . . . . . . . . . . . . . . . . . 23 WUJ . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 52
H Primo-Titan . . . . . . . . . . . . . . . . . . . . . . . . . . 33 WXB . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 46
Pump Power Monitor . . . . . . . . . . . . . . . . . . . 29 WXH. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 44
HDB . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 47
PVML . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 29
HDO . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 48
HDX . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 43
PVML-MAG. . . . . . . . . . . . . . . . . . . . . . . . . . . 29 Y
HED . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 43 YHT . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 68
HED-DS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 43
Q
HPX . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 24 QL . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 52
QLC . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 54
QLQ . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 52
82
82
(FPD-100) Level 1.qxd 11/8/04 1:15 PM Page 83 Dan K. Snelson Clients:023-FLOWSERVE Pumps:023-Job Files:023-Open Jobs:0832-(FPD-100)

83
(FPD-100) Level 1.qxd 11/8/04 1:15 PM Page 84 Dan K. Snelson Clients:023-FLOWSERVE Pumps:023-Job Files:023-Open Jobs:0832-(FPD-100)

USA and Canada


Flowserve Corporation
Pump Division
5215 North O’Connor Blvd.
Suite 2300
Irving, Texas 75039-5421 USA
Telephone: 1 972 443 6500
Telefax: 1 972 443 6800

Europe, Middle East, Africa


Flowserve Corporation
Pump Division
Via Rossini 90/92
20033 Desio (Milan), Italy
Telephone: 39 0362 6121
Telefax: 39 0362 303396

Latin America and Caribbean


Flowserve Corporation
Pump Division
6840 Wynnwood Lane
Houston, Texas 77008 USA
Telephone: 1 713 803 4434
Telefax: 1 713 803 4497

Asia Pacific
Flowserve Pte. Ltd.
Pump Division
200 Pandan Loop #06-03/04
Pantech 21
Singapore 128388
Telephone: 65 6775 3003
Telefax: 65 6779 4607

Bulletin FPD-100 (E/A4) Printed in USA. November 2004. © Flowserve Corporation

To find your local Flowserve representative:

For more information about Flowserve Corporation,


visit www.flowserve.com or call USA 1 800 728 PUMP