You are on page 1of 2

Datasheet for digitalYEWFLO YOKOGAWA

FlowConfigurator-Version: 1.9.0.2197 Date of creation: 10/3/2017


Page: 1/2

Shop Order No. Item No. 1


Order No. Tag No.
Job Name PIL FIT1002
Agency PLANCK S.R.L.
End User Ing. Ronald Tardio Rgst. No.
Plant Name PIL COCHABAMBA Quantity 1
Ms-Code Sensor DY150-JBLBA1-2D/FF1/MV
Reduced bore type not selected
Detector Inner dia. :E10 150mm 6in
Kind of Fluid :C20,F10 Gas
Fluid Name Saturated steam
Maximum Flow Rate :C45,B10,F40 7500 kg/h
Minimum Flow Rate 1000 kg/h
Scale Condi. :C32,C35,F19,F22 Operating temperature and pressure
Operating Temperature :C31,D21 175.4 degC
Maximum Temperature 195 degC
Operating Pressure (gauge) 8 bar
Operating Pressure (abs) :C34,F21 9.014 bar
Minimum Operating Pressure 0 bar
Deviation Factor :C36,F23 1
Density at Scale Condition 4.661 kg/m3
Density at Oper. Condition :C26,D26,F27 4.661 kg/m3
Viscosity 0.01487 mPa.s(cP)
Total Rate :B45
Pulse Rate :B21
Low Cut Value :D10 761.7 kg/h
Nominal Size Selection Turn down Pres. drop
50mm 2in 30.9 2390 mbar
80mm 3in 30.9 640 mbar
100mm 4in 30.9 210 mbar
150mm 6in 26.7 43.8 mbar
200mm 8in 25.7 13.7 mbar
0 20 40 60 80 100 % Max.= 7500 kg/h
Measurable range Optimal range Suitable range
Minimum flow rate Accuracy dividing point (35 m/s)
High velocity range (non-measurable range)
Selected
Nominal Size 50mm 2in 80mm 3in 100mm 4in 150mm 6in 200mm 8in
Result No Good Good Good Good No Good
Reason of NG OVER FLOW OVER SIZE
Reynolds Number at Max. Flow 3491000 2513000 1902000 1285000 961200
Maximum Measurable Flowrate (kg/h) 2750 5310 9280 20300 36300
Minimum Measurable Flowrate (kg/h) 89.2 172 300 762 1410
Flow Velocity at Maximum Flowrate (m/s) 218 113 64.7 29.5 16.5
Minimum Measurable Flow Velocity (m/s) 2.59 2.59 2.59 3 3.11
Min. Flow for Specified Accuracy (1%) (kg/h) 89.2 172 300 762 1410
Predicted Error at Low Reynolds Number (of +0.00% +0.00% +0.00% +0.00% +0.00%
reading)

CHECKED.BY

RE n REMARKS DATE REV.BY


Datasheet for digitalYEWFLO YOKOGAWA
FlowConfigurator-Version: 1.9.0.2197 Date of creation: 10/3/2017
Page: 2/2

Customized converter parameter


Basic Settings
B20 CONTACT OUT: OFF
B30 UPPER DISP: FLOW RATE
B31 LOWER DISP: BLANK
B40 TOTAL START: STOP
B50 A/OUT SELECT: FLOW

Detector Setup
E20 BODY TYPE: Standard
E30 SENSOR TYPE: Standard
E50 DETECTOR No:

Multi-Variable Type
F10 THERMOMETER FUNCTION: Monitor only

Basic Software Data

Hart Protocol
HART® tag:

You might also like