No Need to send the validator for calibration!
Only “Sensors Arrays” need to be calibrated
Step 1 Step 2
10 working days calibration time
Calibration cost is 50% less than others
No Risks in shipping – can be shipped by courier express
No Packing needed as arrays sent with small suite case
ellab.com Pharma & Medical Validation Solutions
1. EVP – Calibration
Can keep spare Array to use the validator when main arrays sent
for calibration
Or if you have 4 arrays, then you can send 2 only and keep 2 until
you receive the first 2 arrays.
Array accuracy is ±0.05°C: NO need to send them yearly
as its tiny accuracy leaves room for drifting over > 1 year
Smart USB plug for T/Cs.
It saves info of: T/C type, S.No. and calibration offsets automatic
‐ Huge time saving in creating qualification setup!
‐ All T/C info like T/C type, S.No. & calibration offsets are
recognized by the software automatically & linked to study.
‐ Sensors are interchangeable across channels – sensor S.No. is
linked to channel nr. automatically – reliable traceability
‐ Great time saving 6 points calibration for 20 sensors / time
‐ Can be used as 3 points at high temp + 3 points at low temp:
save time of repeating calibration.
‐ No need to define setup or select sensors for calibration.
Plug sensor ‐ S.No.& type defined automatically ‐ start calibrate.
‐ user can keep spare sensors calibrated ready to use as calibration
offset & S/Nr is saved on USB plug.
‐ Sensor are interchangeable: plugged in/out from channel to other.
‐ No need to create Study Setup.. Just plug sensors, start
qualification then create study… sensors S.No.& channel nr. will
be linked to mapping study automatically
‐ Or create Study setup, without defining sensors.. Any plugged
sensors are linked automatically by S.No to study mapping
positions, groups, places.
‐ Select study setup from library, any plugged T/Cs info will be
automatically recognized and linked by S.No. to mapping
positions, groups, places.
S.No. linked
Automatically
‐ If sensor is damage, then
replace and new sensor S.No.
will be re‐matched with setup
automatically
So 100% automatic traceable identification of measuring point.
No human error of numbering T/Cs wiring in setup‐ save time.
Calibration is separate from setup so any calibrated sensors can
be used in different studies
S.No. linked
Automatically
‐ IRTD not necessary to be connected during validation.
‐ 8 hours battery working in parallel so no risk in case of power
glitches or brown nuts
‐ Weight 3 KG with very small foot print 22cm x 27 cm.
‐ 2 sample rates recording & 2 print rates for reporting (min. 1sec)
‐ Each sensor plug has PT1000 for cold junction compensation
separately for each sensor….. High accuracy avoiding averaging
‐ Sensor input array accepts different types of sensors T, P or RH….
Fully interchangeable – full usage of channels.
ellab.com Pharma & Medical Validation Solutions
5- Reporting – accuracy
Sensors data displayed by Pos. label, position names and S.No.
Total system accuracy with calibrated Ellab type T smart TC is
±0.10°C (‐50 to 150°C) VS 0.56°C for competitor.
report configuration calculation (analysis) and acceptance limits
can be set before or after study completion
For autoclave report include the following:
‐ Equilibrium time calculated automatically.
‐ Definition of reference position for starting equilibrium time.
‐ Holding time automatic calculation by temp. & tolerance or by
time marker (event).
‐ Reporting of ΔT between ref. position &other positions @ holding
ellab.com Pharma & Medical Validation Solutions
5- Reporting
For autoclave report include the following:
‐ Holding time temp. fluctuations and max ΔT homogeneity are
calculated and compared to acceptance limits.
‐ Automatic Reporting of Hot & cold locations during holding time.
‐ Automatic reporting of Fastest 3 locations reached Sterilization T,
slowest 3 locations reached Sterilization T, slowest location cool to
85°C (Position name / Time).
For freeze dryer and depyro tunnel:
‐ automatic report analyse each stage exposure time within
accepted Temp. limits and check ΔT for each group against max ΔT
For incubator& freezers:
‐ Automatic check of stability exposure time and statistics