You are on page 1of 2

Approx

Dash L P S
Weight
DWG PART Length IN(MM) IN(MM) IN(MM)
QTY DESCRIPTION MATERIAL LB(KG)**
REF NUMBER
59.15 47 23X1 56
SHELL -1
(1502) (1194) (584) (25)
Filament Wound Epoxy/Glass
1 1 99218 SHELL composites - Head locking grooves 99.15 87 56X1 69
-2
integrally wound in place. (2518) (2210) (1422) (31)
2 A/R A/R F/C Port CF3M * 139.15 127 80X1 81
-3
3 A/R A/R F/C Port Seal Ethylene Propylene . (3534) (3226) (2032) (37)
HEAD - NON CODED 179.15 167 64X2 94
-4
(4550) (4242) (1626) (43)
4 2 96243 Elliptical Head Assy. Engineering Thermoplastic.
219.15 207 78X2 106
-5
5 2 96000 Head Seal Ethylene Propylene - O - Ring (5566) (5258) (1981) (48)
HEAD INTERLOCK 259.15 247 92X2 119
-6
Quick Release Spiral (6582) (6274) (2337) (54)
6 2 47336 316 Stainless Steel.
Ring 299.15 287 106X2 130
-7
VESSEL SUPPORT (7598) (7290) (2692) (59)
7 2+
52169 Saddle Engineering Thermoplastic. 339.15 327 120X2 142
-8
+
(8614) (8306) (3048) (64)
8 2 45042 Strap Assy. 304 Stainless Steel-PVC Cushion.
5/16-18 UNC, 2.5'' L, 18-8 Stainless
9 4 46265 Strap screw.
Steel.
ELEMENT INTERFACE
10 2 A/R Adapter Engineering Thermoplastic.
11 2 52245 Adapter seal Ethylene Propylene - O - Ring

12 4 A/R PWT Seal Ethylene Propylene - O - Ring


13 1 97014 Thrust Cone Engineering Thermoplastic.
+ 3 each furnished with length code 4,5,6,7 & 8.
PRECAUTIONS:
RATING: DO…read, understand and follow all instructions; failure to ORDERING:
take every precaution will void warranty and may result in Using the chart below, please check the features you require
DESIGN PRESSURE………………………......300 PSIG vessel failure
(2.1MPa) DO…mount the shell on horizontal members at span “S” VESSEL LENGTH CODE – please check one
MAX OPERATING TEMP…………………….…..190°F using compliant vessel supports furnished; Shim saddles if
(88°C) required. Tighten hold down straps just snug MODEL 80S30 Non Coded -1 -2 -3 -4 -5 -6 -7 -8
MIN. OPERATING TEMP…………........……….…20°F DO…align and center side ports with the manifold header.
(-7°C) Correct, causes of misalignment in a row of vessels MEMBRANE BRAND AND MODEL
FACTORY TEST PRESSURE………………...450 PSIG connected to the same header
(3.1 MPa) DO…use flexible type IPS grooved-end pipe couplings, at Please supply adapters for the following membrane brand and specific model
side ports; allow full, 0.125 inch gap between port and Brand_________________________ Model_______________________
QUALIFICATION PRESSURE ………….....…1800 PSI piping, and position piping to maximize flexibility of
(12.4 MPa) connection.
CERTIFICATION REQUIRED
INTENDED USE: DO…provide flexibility in, and support for piping manifolds ADAPTER KITS
The CodeLine 80S30 Non Coded Fiberglass RO Pressure so that vessel can grow in length under pressure without
CE Marked Standard.
Vessel is designed for continuous, long term use as a undue restraint; provide additional flexible joints in large UP DOWN
housing for reverse osmosis membrane elements to desalt pipes leading to manifold header. Certified by Pentair. STREAM STREAM
typical brackish waters at pressures up to 300 psi. Any DO…provide overpressure protection for vessel set at not
make of eight-inch nominal diameter spiral-wound more than 105% of design pressure
element is easily accommodated; the appropriate DO…inspect end closures regularly; replace components that PERMEATE PORT CONFIGURATION:
interfacing hardware for the element specified is have deteriorated and correct causes of corrosion
furnished with the vessel. DO… Lubricate seals sparingly, using nonpetroleum Standard. 1” FNPT & 1.5” IPS GROOVED NORYL HEAD.
Based lubricants, i.e. Parker Super O-lube®, Optional .1” BSP F/JIS F Parallel Thread & 1.5” IPS GROOVED NORYL HEAD.
The Shell of CodeLine 80S30 Non Coded vessel is Glycerin or suitable silicone based lubricants.
designed in accordance with the engineering standards of
the Boiler and Pressure Vessel Code of the American DO NOT…work on any component until first verifying that STRAP ASSEMBLY
Society of Mechanical Engineers (ASME) as per Section pressure is relieved from vessel
X. ASME Edition 2015. DO NOT…make rigid piping connections to ports or clamp Standard SS304 Optional SS316 Optional SS316L
vessel in any way that resists growth of fiberglass shell
The CodeLine 80S30 Non Coded vessel must be installed under pressure;
operated and maintained in accordance with the listed *** DIA = 0.015 in. (0.4mm) and FEED/CONCENTRATE PORT SELECTION
precautions and good industrial practice to assure safe *** L = 0.2 in. (6mm) for a length code –8 vessel
operation over a long service life. DO NOT… hang piping manifolds from ports or use vessel in Material of Construction Standard CF3M Optional Duplex SS (CD3MN)
any way to support other components Optional Super Duplex SS (CD3MWCuN)
The high performance Filament wound FRP shell must be
DO NOT…tighten Permeate Port connection more than one
allowed to expand under pressure; undue restraint at Configuration Standard - CF3M 1D5D
turn past hand tight
support points or piping connections can cause leaks to
DO NOT… operate vessel without connecting both Permeate Optional – Multi ports :( Refer SPEC.SHEET/PM/1.5”-3”for Multi port selection)
develop in the shell. This side-ported vessel requires
Ports internally to complete set of elements or otherwise
special precautions in mounting and connection to piping
plug ports internally so that external piping connection is
so that the vessel will not be subjected to excessive stress
not subjected to feed pressure
due to bending moments acting at the side openings in the Serial number end
DO NOT…install Spacer on downstream end of vessel
fiberglass shell. The end closure, incorporating close
DO NOT…operate vessel without Thrust Cone installed
fitting, interlocking metal components, must be kept dry Opposite end
downstream
and free of corrosion; deterioration can lead to
DO NOT…pressurize vessel until double-checking to verify
catastrophic mechanical failure of the head.
that the Locking Ring is in place and fully seated.
PORT SIZE CODE
Pentair will assist the purchaser in determining the DO NOT…operate vessel at pressure and temperature in
suitability of this standard vessel for their specific excess of its rating. D 1½” GROOVED END
operating conditions. The final determination however, DO NOT…operate vessel with permeate pressure in excess of E 2” GROOVED END
including evaluation of the standard material of 125 psi at 190°F (0.86 Mpa at 880C).
construction for compatibility with the specific corrosive DO NOT…tolerate leaks or allow end closures to be routinely F 2½” GROOVED END
environment, shall be the responsibility of the purchaser. wetted in any way
Alternate materials with enhanced corrosion resistance are DO NOT…operate outside the pH range 3-11. For complete information on proper use of the vessel
Please refer to the 80S Series USER’S GUIDE 94182.
available on special order.

Specifications are subject to change without notice. CODELINE BODY LABELS ARE PLACED AT
90 TO SERIAL NUMBER END AND AT 270
ON THE OPPOSITE SIDE END

DWG. NO. 99172-Q, © Pentair PAGE 2 OF 2.