RC TWO-WAY SLAB DESIGN (ACI318-08)

TEDDS calculation version 1.3.00

lx x

½ Column strip
Middle strip
ly

½ Column strip
½ Column strip Middle strip ½ Column strip

TWO-WAY SLAB PANEL

8 in Section at middle strip along X axis

Concrete type; Normal weight

Concrete modification factor;  = 1.00

Slab definition
Slab thickness; h = 5.00 in;

Span along x - dir; lx = 15.000 ft; Span along y - dir; ly = 15.000 ft

Clear cover to positive steel; cc = 0.75 in; Clear cover to negative steel; c’c = 0.75 in

Effective flanged beam section

Flange width; bf = 9.000 in; Beam depth; hb = 12.000

in

Beam width; bw = 9.000 in;

Materials
Comp. strength of concrete; f’c = 2500 psi; Yield strength of steel; fy = 40000

psi

Loads
Total factored ultimate load on slab; wu = 124.000 psf
Check for the depth of slab provided
Minimum depth required; hmin = 5.000 in
PASS - Slab thickness provided is sufficient for deflection

DESIGN SLAB IN THE X-DIRECTION


Support moment – Column strip
Area of steel required; 0.120 in2/ft; Steel provided(A'sx_col), No. 3 @ 8.0 in
centers (0.166 in2/ft )
PASS - Area of steel provided is OK
Midspan moment – Column strip
Area of steel required; 0.120 in2/ft; Steel provided(Asx_col), No. 3 @ 8.0 in
centers (0.166 in2/ft )
PASS - Area of steel provided is OK
Support moment – Middle strip
Area of steel required; 0.120 in2/ft; Steel provided(A'sx_mid), No. 3 @ 8.0 in
centers (0.166 in2/ft )
PASS - Area of steel provided is OK
Midspan moment – Middle strip
Area of steel required; 0.120 in2/ft; Steel provided(Asx_mid), No. 3 @ 8.0 in
centers (0.166 in2/ft )
PASS - Area of steel provided is OK

DESIGN SLAB IN THE Y-DIRECTION


Support moment – Column strip
Area of steel required; 0.131 in2/ft; Steel provided(A'sy_col), No. 3 @ 8.0 in
centers (0.166 in2/ft )
PASS - Area of steel provided is OK
Midspan moment – Column strip
Area of steel required; 0.120 in2/ft; Steel provided(Asy_col), No. 3 @ 8.0 in
centers (0.166 in2/ft )
PASS - Area of steel provided is OK
Support moment – Middle strip
Area of steel required; 0.120 in2/ft; Steel provided(A'sy_mid), No. 3 @ 8.0 in
centers (0.166 in2/ft )
PASS - Area of steel provided is OK
Midspan moment – Middle strip
Area of steel required; 0.120 in2/ft; Steel provided(Asy_mid), No. 3 @ 8.0 in
centers (0.166 in2/ft )
PASS - Area of steel provided is OK
Distribution reinforcement - (for shrinkage and temperature)
Min distribution steel required; At_req = 0.120 in2/ft; Steel provided , No. 0 @ 8.0 in centers -
(0.166 in2/ft )
PASS - Area of steel provided (Distribution) OK
Check for shear
Required shear capacity; Vu = 0.842 kips; Design shear strength ; Vc = 3.656

kips

PASS ‐ Shear capacity  
Check for clear cover (ACI 7.7.1)
Permissible min nominal cover to all reinforcement; cmin = 0.75 in

Clear cover to tension reinforcement (negative); cc_neg =0.750 in


PASS - Cover to steel resisting hogging exceeds allowable minimum cover
Clear cover to tension reinforcement (positive); cc_pos = 0.750 in
PASS - Cover to steel resisting sagging exceeds allowable minimum cover
Schematic reinforcement distribution.
y

lx x

½ Column strip
A'sy_col
Asx_col A'sx_col

Asy_mid

Middle strip
ly

Asx_mid A'sx_mid
Asy_col

½ Column strip

A'sy_mid

½ Column strip Middle strip ½ Column strip

TWO-WAY SLAB PANEL Legend -


Top reinf.
(Reinforcement layout)
Bottom reinf.