Structure group 71
04/08
MEASURING TECHNIQUE
PRESSURE GAUGE
P.O. Box 260 D-32632 Lemgo Grevenmarsch 38 D-32657 Lemgo Tel. 0049 (0) 5261 / 9377-0 Fax -51
Certified to DIN EN ISO 9001 e-mail: info@armatherm.de Internet: www.armatherm.de
Dear customer, Structure group 71
in our new data sheets, we have created the possibility to state
the correct execution of each instruments by means of code numbers.
Please use this probability.
Content
Class 1,6 2
Requested code-no. results: 7 1 : 0 3 2
All usual connections also available, for example: NPT, BSPT and so on.
2 2
Measuring ranges with double scale like bar/psi, lb/in or kg/cm are available.
Starting from NG 63, manometers with adjustable red pointer, triangular front ring with clamp strap mounting
or front / back fixing flange available.
Please indicate this data clearly.
Range Code-no.:
0- 1,0 bar 21
0- 1,6 bar 22
0- 2,5 bar 23
0- 4 bar 24
0- 6 bar 25
0 - 10 bar 26
0- 16 bar 27
0- 25 bar 28
0- 40 bar 29
Other ranges in accordance with EN
in „bar“ possible.
Class 1,6 2
Requested code-no. results: 7 1 : 9 2
All usual connections also available, for example: NPT, BSPT and so on.
2 2
Measuring ranges with double scale like bar/psi, lb/in or kg/cm are available.
Please indicate this data clearly.
All usual connections also available, for example: ¼“NPT, BSP, BSPT, M12x1,5 and so on.
Measuring ranges with double scale like bar/psi are available.
Clamp strap mounting, Max.- indicator (ab 2,5 bar), available.
Please indicate this data clearly.
Range Code-no.:
0- 1,0 bar 21
0- 1,6 bar 22
0- 2,5 bar 23
0- 4 bar 24
0- 6 bar 25
0- 10 bar 26
0- 16 bar 27
0- 25 bar 28
0- 40 bar 29
Other ranges in accordance with EN
in „bar“ possible.
Class 1,6 2
Requested code-no. results: 7 5 3 5 : 0 3 P 2
2 2
Measuring ranges with double scale like bar/psi, lb/in or kg/cm are available,
as well as with rear fixing flange.
Please indicate this data clearly.
Range -1 -0 00 0+ 6 25
bar
-0,6 -0 01 0 + 10 26
-1-0 +0,6 02 0 + 16 27
-1-0 +1,5 03 0 + 25 28
-1-0 +3 04 0 + 40 29
-1-0 +5 05 0 + 60 30
-1-0 +9 06 0 + 100 31
-1-0+15 07 0 + 160 32
0+0,6 20 0 + 250 33
0+1 21 0 + 400 34
0+1,6 22 0 + 600 35
0+2,5 23
0+4 24
Option Retaining ring
stainless steel Ü1
Rear fixing flange
steel, black H2
no Option 00
Class 1 1
All usual connections also available, for example: M20x1,5, BSP, BSPT, material stainless steel and so on.
Case and ring, stainless steel
Measuring ranges with double scale like bar/psi and so forth, are available.
Please indicate this data clearly.
Limit value signal generator for manometers see data sheet of our group 551
All usual connections also available, for example: M20x1,5, BSP, BSPT and so on. Range Mounting
Measuring ranges with double scale like bar/psi etc. are available. 0 - 0,6 to 0 - 1000 bar = Ms (3)
Please indicate this data clearly. 0 - 1600 bar = St (2)
0 - 0,6 to 0 - 1600 bar = Va (8)
Range Code-no.:
mbar
-2,5-0 -1-0+1,5 0-2,5 AA BA CA
-4-0 -1-0+2,5 0+4 AB BB CB
-6-0 -2-0+4 0+6 AC BC CC
-10-0 -4-0+6 0+10 AD BD CD
-16-0 -6-0+16 0+16 AE BE CE
-25-0 -10-0+15 0+25 AF BF CF
-40-0 -15-0+25 0+40 AG BG CG
-60-0 -20-0+40 0+60 AH BH CH
-100-0 -40-0+60 0+100 AI BI CI
-160-0 -60-0+100 0+160 AK BK CK
-250-0 -100-0+150 0+250 AL BL CL
-400-0 -150-0+250 0+400 AM BM CM
-600-0 -200-0+400 0+600 AN BN CN
Class 1,6 2
Requested code-no. results: 7 2 : 0 3 2
Manometer also available with triangular front ring with clamp strap mounting or front / back fixing flange.
Please indicate this data clearly.
Case Execution
Protection type: IP 54
NG 100 Stainless steel, bayonet ring case
Window instrument glass 7 2 3 5 2 : 3 P
Vertical mounting G ½“
Connection Ms 3 VA 8
Range Code-no.:
mbar
-2,5-0 -1-0+1,5 0-2,5 AA BA CA
-4-0 -1-0+2,5 0+4 AB BB CB
-6-0 -2-0+4 0+6 AC BC CC
-10-0 -4-0+6 0+10 AD BD CD
-16-0 -6-0+16 0+16 AE BE CE
-25-0 -10-0+15 0+25 AF BF CF
-40-0 -15-0+25 0+40 AG BG CG
-60-0 -20-0+40 0+60 AH BH CH
-100-0 -40-0+60 0+100 AI BI CI
-160-0 -60-0+100 0+160 AK BK CK
-250-0 -100-0+150 0+250 AL BL CL
-400-0 -150-0+250 0+400 AM BM CM
-600-0 -200-0+400 0+600 AN BN CN
Class 1,6 2
Requested code-no. results: 7 2 : P 2
Manometer also available with triangular front ring with clamp strap mounting or front / rear fixing flange.
Please indicate this data clearly.
Range Code-no.:
0- 1,6 bar 22
0- 2,5 bar 23
0- 4 bar 24
0- 6 bar 25
0- 10 bar 26
0- 16 bar 27
0- 25 bar 28
0- 40 bar 29
Class 1,6 2
Requested code-no. results: 7 4 3 9 : 0 3 P 2
2 2
Measuring ranges with double scale like bar/psi, lb/in or kg/cm are available,
as well as rear fixing flange.
Please indicate this data clearly.
Differential pressure gauges are also available in stainless steel execution and with or without oil filling.
Thread G ½“ P ½ NPT U
Range 0-0,6 20 -1-0+3 04
bar
mbar 0-1 21 -1-0+5 05
0-1,6 22 -1-0+9 06
0-2,5 23 -1-0+15 07
0-4 24 mbar
0-6 25 0-10 70
0-10 26 0-16 71
0-16 27 0-25 72
0-25 28 0-40 73
-0,6-0 01 0-60 74
-1-0 00 0-100 75
1-0+0,6 02 0-160 76
1-0+1,5 03 0-250 77
Option
Adjustable red
marking pointer RM
no option 00
Class 1,6 2
no Option 00
Class 1,6 2
Requested code-no. results: 7 3 3 2 : 2
Class 2,5 by executions with protective foil.
Measuring flange ∅ indicating range < 250 mbar = 160 mm, >400 mbar = 100 mm
Limit value signal generator see data sheet of our group 551
All usual connections also available, for example: M20x1,5. and so on.
Max.- indicator and other flange executions ( open flange ) are available.
Please indicate this data clearly.
Operating ranges: during resting load scales final value
during changing load 90 % from scales final value
low pressure security: up to 5-fold, max. 40 bar and/or max. 2,5 bar by measuring flange of ∅160 mm
Subject to alteration, even of technical kind. 02/05