GENERAL CATALOGUE
2015
Treasures are always found off
the beaten path.
There’s no question in our mind who we are. We could name the
countless accolades and awards we’ve received over the years, but
it really doesn’t matter unless you know our name. In life, we are
naturally drawn to the familiar, and accordingly, follow in the
footsteps of those before us. However, there are those who dare to
step off the beaten path. Through reaching for the new, they
discover that there’s so much more out there. In this moment,
boundaries are tested and the world grows just a little bigger.
Allow us to introduce ourselves. Our name is Hisense. We’ve been
around for a long time, but perhaps not in your area. In a way, we’re
also searching for more. We’ve reached the pinnacle of success in
our own country and now we’re ready to see what else we can do.
We understand that you’re more familiar with the other guys,
because they’ve been around for many years. But rest assured,
when you choose us, you are walking through the door of a new era.
Because we’ve never met, you may not understand why we don’t
feel quite right about tackling the market with aggressive prices and
overwhelming promotions. It’s as simple as this: we don’t think we
need to prove ourselves through talk. We believe that the best things
in life exceed expectations and shatter doubts, and are not proven
through mere words. We simply want you to be so enticed by
affordable prices and unbeatable quality that you’ll veer away from
the familiar.
Let’s discover new frontiers together and make the world just a little
bigger today. We’ve already unlocked the door to a new era. Now,
it’s your choice to walk through it. Decide Hisense.
Hisense Introduction
Hisense is a large electronic information industry corporation of China
founded in 1969 and owns Hisense Appliance and Hisense Kelon Appliance
these two listed companies. Furthermore, Hisense is the only enterprise
group in China which has three well-known trademarks as Hisense, Kelon
and Ronshen at the same time.
Comprehensive Air Conditioning Solutions -13- High Intelligent Control System -35-
05
Product Line-up Optional Parts
06
Customer First,
Service Foremost
07
Focus on Today's Requirement
Why Choose Hisense VRF Solutions
Strict Quality Control
Comprehensive Air Conditioning Solutions
Overall Support for Customers
Benefit for End Users
08
Focus on
Today's Requirement
Focus on Energy Conservation
Customer First, Service Foremost
According to the statistics from authority, building energy consumption takes up 35% ~50% of the main energy consumption. And
air-conditioning is a big consumer of building energy consumption, taking up about 40% ~60%. So it is very important to effectively
reduce the air conditioning energy consumption.
0 0%
30% 40% 50% 60% 70% 80% 90% 100%
Central Air-conditioning Load Distribution of an Office Building During a Cooling Season
Hisense heat recovery Hi-FLEXi R series realizes simultaneous cooling and heating through perfect combination of DC inverter
technology and heat recovery technology, which realizes a 20% energy saving compared with traditional air conditioning, achieving
lower running cost.
RoHS Reaction
Actively respond to Europe RoHS directive, control the use of hazardous substance strictly. RoHS
stands for Restriction of Hazardous Substance Directive, which specifies six substances ( Lead
(Pb), Mercury (Hg), Cadmium (Cd), Hexavalent chromium (Cr), PBDE or PBB ) banned from using in
electrical and electronic equipment. Hisense actively reponded to RoHS directive and implement-
ed a series of programs and measures, which aims to preserve human health and ensure that the
recycling and treatment of wasted eletronic and electrical equipment meet the environmental
stardard.
09
Focus on
Today's Requirement
Focus on Healthy Indoor Environment
Noise Control
The creation and use of mechanical equipment has brought human prosperity and progress, but noise pollution has been increasingly
strong in recent years. As we all know noise pollution has lots of negetive effects on our relaxation, work, study, and even on our
health, so noise control is becoming more and more significant. Hisnese realizes excellent noise control through a series of improve-
ment on compressor, fan motor and fan structure. The noise level of outdoor units has been reduced dramatically, and the lowest
noise level of Hisense indoor units is down to 21dB.
10
Why Choose
Hisense VRF Solutions
High Technology and Outstanding Operation Performance
Customer First, Service Foremost
Based on high technology and manufacturing ability, Hisense has been developing rapidly these years. And Hisense has gained great
reputation in the commercial air conditioning field. Hisense adopts strict quality control standard during the manufacturing and test
process, ensuring best quality of products. Hisense VRF’s outstanding operation performance and system reliability ensures low running
cost over its entire service time.
11
Strict Quality Control
Hisense's production base is located in Hisense Information Industrial Park in Qingdao Economic Development Zone with a total area of
12
Comprehensive Air
Conditioning Solutions
Air Cooled Outdoor Systems
Customer First, Service Foremost
Heat Pump - for Either Heating or Cooling Operation From One System
G series
Latest Full DC inverter series with large capacity range, realizing significant improvement in
operation efficiency under partial load.
Reliable operation and intelligent control make Hi-FLEXi G series a perfect choice for your air
conditioning solution.
Compact structure and light weight, making it much easier for transportation and installation.
8~54HP
M series
Advanced multi-split technology improves the system performance and energy efficiency.
Flexible design and installation provides better air conditioning solution for workplace, leisure and
living space.
8~48HP
C series
Hi-FLEXi C series aim at improving the comfort of space; every detail is fully considered in the
process of design and installation, accordingly bring you completely new space experience.
Front flow structure greatly improves the flexibility in installation.
8/10/12HP
Heat Recovery - for Simultaneous Heating and Cooling Within One System
R series
Realizing simultaneous heating and cooling operation within one refrigerant system, which not only meets
various requirements of different customers, but also contributes to energy conservation.
Flexible design and installation provide better air conditioning solution for workplace, leisure and living
8~54HP space.
W series
Wide application ranges include surface water circuit, underground water circuit, seawater source, urban
sewage source, soil source.
Allows heat recovery within one system because of the storage of energy in the water circuit.
3~20HP Suitable for multi-story and large building due to the many possibilities of water piping.
13
Comprehensive Air
Conditioning Solutions
L series
Hi-Smart L Series, household central air conditioning system, is specially designed for medium and large
high-end real estate. The outstanding appearance and function design, the application of leading technology
and high quality components make it a perfect choice for users.
4/5/6HP
E series
Hi-Smart E Series, household central air conditioning system, of which the compact outdoor units bring
high flexibility of installation and maintenance, and with the light and slim indoor units creates an elegant
and high taste domestic environment.
3/4/5HP
Wired Controller
Expansion
Valve Box
AHU
The Hisense AHU-KIT can integrate external heat exchangers of air handling units (AHU) into a Hisense
Wired Controller
VRF system to be used for air conditioning, which can provide more flexible air conditioning solutions and
Wired Controller
save more renovation cost in the building air conditioning renovation.
4~20HP
14
Overall Support
for Customers
Echoing the service idea of "Customer First", Hisense is making efforts to provide overall support to our customers, including
Customer First, Service Foremost
product promotion, air conditioning solution design, installation and commissioning, maintenance, etc. Meanwhile, Hisense has
professional training team, related training facility and on-line training platform to conduct a comprehensive training on products, AC
solutions design, installation and commissioning to our customers.
15
Overall Support
for Customers
Selection Software
16
Overall Support
for Customers
Data Collector
Customer First, Service Foremost
Main Function
Hisense VRF test run
Recognize warning and error
Maintenance and monitoring
Central control test
Collector Software
.....
AC system
Power supply
cable USER
ble
Network Cable
..... USB Cable
AC system
Data Collector
Note: The data collector can be powered by the USB, but if it needs to use it for a long time, we recommend to use more stable external power supply.
17
%HQHßWIRU(QG8VHUV
Precise Temperature Control
Intelligent Controls
Hisense provides various controllers and control schemes, which helps end users enjoy the great convenience brought by the improve-
ment of technology while meets the common air conditioning demand.
18
Technological Hisense
19
High Technology Support Platform
Intelligent Operation, Great Reliability
20
High Technology
Support Platform
Advanced Technology is The Cornerstone of Hisense VRF
Technological Hisense
1 2
3
Compact structure
Efficient inner screwed copper pipe Efficient DC drive
Better dynamic balancing
Newly developed high efficiency fin Smooth operation and low noise
High efficient and low noise
21
High Technology
Support Platform
New Scroll Compressor
Technological Hisense
Comperssor Suction Line
Comperssor Discharge Line
Refrigeration Oil Flow Line
Asymmetric scroll
disc
DC variable speed
motor
Big silencing chamber,
lower noise
Asymmetric scroll: the time difference between the suction of outside Symmetric scroll: the outside chamber and inside chamber end gas
chamber and inside chamber is 180°; The pressure of outside chamber suction at the same time, the pressure of outside chamber and inside
and inside chamber are different. The pressure distribution in chamber are equal. The pressure distribution in compressing
compressing chambers are asymmetric. chamber are symmetric.
22
High Technology
Support Platform
DC Inverter-driven Compressor Motor
By the use of DC motor, the performance is improved at around 20 ~ 40Hz where the operation time of the inverter compressor is
Technological Hisense
longest. Meanwhile, the rotor of compressor's motor is divided into two parts to suppress electromagnetic interference (EMI) which
achieves low noise.
95 DC Motor
·High Efficient
·Eliminate Peculiar ·Low Height
Electromagnetic ·Low Copper Loss
·High Efficiency AC Motor
7200(rpm)
3600
DC Motor Rotor Centralized Winding Stator 2400
1200
0
Load% Load%
23
High Technology
Support Platform
Multiple Oil Circuit Protection
Oil balance between outdoor units is realized through two-stage oil separation technology, oil-return technology, and oil balancing between
Technological Hisense
modules, which ensures more secure and reliable operation of the system.
structure inside high-pressure chamber compressor, only a small the second-stage oil separation through large-capacity, high efficiency
amount of oil is brought out of the compressor. centrifugal oil separator, the separation efficiency can be over 99%.
the modules.
1
Accumulator
only 60 seconds, after the oil-return control, it will automatically return to the previous Time
operation state.
Z
Low :
In winter under heating mode, the oil return operation is implemented without changing to Z
24
High Technology
Support Platform
Oil Balancing Control Between Outdoor Units
Through adjusting the relationship between the amount of discharge oil and return oil in the compressor, accumulator and the
Technological Hisense
oil separator, it can realize automatic balance of lubricants between the various outdoor units without oil balance pipes, avoid
fluctuations of system pressure and temperature caused by oil balance pipe mode, and simplify the construction and improve
the operational stability and comfort of system.
Without oil
Liquid pipe balance pipe
Gas pipe
Gas phase
Gas phase
25
High Technology
Support Platform
Stepped Efficient Heat Transfer Fins
Adopt new type fins and copper pipes which can improve the heat transfer efficiency
Technological Hisense
Previous fins The latest developed fins Hierarchical diagram of
hydrophilic aluminum foil
Lubricating layer
Hydrophilic coating
Efficient inner screwed
Corrosion-resistant coating
copper tube
Ő Fin
Ő
Overlapping section Overlapping section
surface of fins surface of fins Not easy to frost in heating mode;
Slow down the corrosion of heat exchanger by corrosive gases;
Destroying the surface tension of water droplets accelerates the
Wind direction Wind direction down flow speed of defrost water or condensate water and
Thick Thin improves the air conditioning performance.
First stage of
super-cooling
Second stage of
super-cooling The increased cooling
Heat exchanger capacity in super-cooling
super-cooling section cycle
Sub-cooler
○ The two-stage super-cooling cycle improves cooling capacity;
○ The pressure loss of the refrigerant flowing in the pipe is reduced
○ The Increased super-cooling degree promotes the stable operation
of the electronic expansion valve; Cooling capacity
○ The increased super-cooling degree helps increase the total piping length.
26
High Technology
Support Platform
accurately grasp the defrosting opportunity, and significantly reduce the amount of frost, only 1/3 of that under ordinary defrosting mode.
Meanwhile together with unique bottom anti-frost design structure, “2 in 1” heat exchanger, it can ensure that there is no frost at the bottom
of outdoor heat exchanger during winter heating. When defrosting, the mixture of ice and water left along the fins is heated fully to liquid
and discharged through the bottom drain hole, so as to avoid accumulation of frost at the bottom leading to poor heating performance.
Little frost Still not much frost Little frost Still not much frost
Heating
Heating operation Heating operation Heating operation Heating operation
operation
Traditional multi-split AC defrosting mode only refers to Time and Temperature parameter , besides these, Hisense adopts the pressure
defrosting mode, which adopts the pressure sensor to get the pressure signal and completes the variable parameters defrosting
operation through the Pressure, Temperature and Time parameter.
HP
90 5 10 15 20 25 min
seconds
27
High Technology
Support Platform
Technological Hisense
Temperature Sensing Refrigerant Flow Control
There are multiple thermal probes in the system, which will make Indoor units adopt microcomputer electric expansion valve
real-time detection and feedback on the outdoor temperature, with 2000-stage automatic adjustment function, which can
indoor temperature and outlet air temperature etc, the system make precise flow adjustment automatically according to
output is adjusted by the master controller. the actual load of indoor units with more accurate
temperature regulation and better energy efficiency.
n an
Unique Design
outlet air temperature sensor
Conventional
Temperature Control
Too Hot
Most Comfortable
±0.5
Comfortable
28
Intelligent Operation
Great Reliability
25-step
Peak Temperature
29
Intelligent Operation
Great Reliability
Automatic Reset Function
The operating data can be recorded automatically as power failure occurs. When the power supply is restored, the system can fulfill
Technological Hisense
automatic start-up ( Manual operation is also allowed ), the previous operation mode can be renewed without being reset, which brings
more intelligent and considerate service to users.
The system operates normally After power off ( memory storage ) Restore to the previous state when
before power off system stops running the power supply is recovered.
01 02 03
Rotational Operation
OFF OFF ON
Next Time
30
Intelligent Operation
Great Reliability
Double Back-up Operation Function, Double Service Guarantee
The back-up operation function that prevents the system from coming to a complete stop can be fulfilled in two ways.
Technological Hisense
As one of outdoor units breaks down, the rest of outdoor units in the same refrigerant system can turn to operate urgently ( more
than 154KBtu/h system practicable ).
As one compressor is failed, the other compressor in the same outdoor unit can be set to emergency operation mode.
Central air conditioning system is working under partial load most of the time; Hi-FLEXI G series optimizes the software and system especially
for partial load, making the system more energy efficient under partial load condition.
Smart and Precise Unit Capacity Allocation ( For Full DC Inverter Series )
Tests show that multi-split air conditioning units are most efficient under 40% 70% partial load condition, and the power consumption is
lowest. Take 20HP units ( double module ) as an example, when the units operate under 12HP load, the load distribution of each module:
common product is 10HP ( full load ) +2HP ( ultra-low load ); Hisense Hi-FlEXI G series is 6HP+6 HP ( intermediate load ).
~
VS
Hisense Hi-FlEXI G Series: Traditional product:
d
The efficiency will be the highest and the power consumption will be In normal operation, the module combination is operated at full load + ultra-low
lowest when each module unit is working at 40% - 75% partial load. load, which influences the service life of units and consumes more power.
31
Intelligent Operation
Great Reliability
Technological Hisense
It achieves balance between the comfort and energy saving while meeting the power demand for daily work.
t
cos
ting
era
Op
Setting Power
Greater efficiency within the set range
Operati
Daily running time ng cost
Morning Night
For mode settings, please contact your local service engineer. The output capacity of the unit at this moment is less than the rated value
because operating power is limited.
External forces make the fan Instantaneous reverse rotation with sudden
counter-rotating increased torque may cause damage to the External forces make the fan counter-rotating Stop the fan before start Forward rotation with
blades the unit small starting torque,
protect fan blades
Anti-snow Function
Connector Outdoor Unit PCB SS3:Snow sensor
In the event of bad weather like snowstorm, even if outdoor unit
SS3
is not operating, the sensor for snow on outdoor PCB can still be
shorted because of natural snowflake, then the outdoor fan Power Supply
32
Easy Installation
Easy Maintenance
Compact Structure and Light Weight Design,Easy Installation
Easy and flexibility of installation are further enhanced by adopting the outdoor unit’s light weight and compact design.
Technological Hisense
The maximum size and weight of the basic module of each series. Model Outer Dimension
Temperature ℃
46.9443
45.4512
43.9582
42.4651
40.9721
39.4790
37.9859
36.4929
34.9998
Airflow Schematic Exhaust duct installation Layered installation effect picture
Automatic Addressing
System can assign indoor unit addresses without manual setting automatically, it is suitable for the use of multiple indoor units of large system.
ON ON
Realizing test run
through the controller
at the indoor unit side Realizing test run
1 2 3 4 5 6 1 2 3 4 5 through the DIP-switch
at the outdoor unit
Cooling mode test run Heating mode test run
6 side.
33
Easy Installation
Easy Maintenance
Intelligent Operation
Technological Hisense
Hisense VRF system is highly intelligentized and has no requirement for machine room and operators,realizing much more flexible and
convenient control and lower cost.
Data Collector
Data Collector is designed to quickly inspect the units operating
status. Problems can be found out as early as possible, then
solution can be taken accordingly.
Main Function
ON/OFF control, operation mode, temperature
setting, air flow setting, louver setting. Wireless router
HYJE-H01H
Adapter Specifications
Model name HYJE-H01H Isolation Voltage AC 3000V
* The standard parts of this system includes the converter HYJE-H01H and the client control software HRM-G01 ( it can be downloaded and installed in
the APP STORE ), The IPAD is the registered trademark of Apple Inc.
35
High Intelligent
Control System
Various Controllers
Wired Controller: HYXE-J01H
Technological Hisense
Features:
4 inch large LCD screen with a resolution of 320×185.
HYXE-J01H
Functions are displayed in iconic form, more intuitive. (Touch keys)
Operation navigation, more convenient.
It can be used in main-auxiliary control mode or in concert with wireless receiver.
Various displaying settings: backlit control, contrast ratio setting, backlit displaying time setting, keytone setting, indicator light brightness
setting, clock setting, language switch ( Between Chinsese and English ).
Main Functions
Cooling/Heating/Dry/Fan/Auto Fan Speed/Swing Louver Temperature Setting Timer
Error Code Display Error History Display Mode Lock Address Setting
8
Temp. 27
27
27 C
25
25 C
Specifications
Model Name HYXE-J01H
Power Supply DC 12 ~ 17 V
Outer Dimension 120X120X16mm
Max. Connectable IDU Number 16
36
High Intelligent
Control System
Wired Controller: HYXE-F01H
Feature:
Technological Hisense
Main Functions
Cooling/Heating/Dry/Fan/Auto Fan Speed/Swing Louver Temperature Setting Timer
One Touch Test Run Air Filter Cleaning Reminding Error Code Display Check
ON ON
Realizing test run Realizing test run
through the controller through the DIP-switch
at the outdoor unit
at the indoor unit side 6 side.
1 2 3 4 5 6 1 2 3 4 5
Cooling mode test run Heating mode test run
Specifications
Model Name HYXE-F01H
Power Supply DC 12~17 V
Outer Dimension 120X120X19mm
Max. Connectable IDU Number 16
Test Run Air Filter Cleaning Reminding Error Code Display Check
Specifications
Model Name HYXE-A01H
Power Supply DC 12~17 V
Outer Dimension 120X120X19mm
Max. Connectable IDU Number 16
37
High Intelligent
Control System
Wired Controller: HYXE-G01H
Technological Hisense
Features:
Compact structure with a size of 86×86mm.
Large LCD backlit screen, simple appearance. HYXE-G01H
Built-in wireless receiver under the panel, two kinds of control mode for selection.
Main Functions
Cooling/Heating/Dry/Fan/Auto Fan Speed/Swing Louver Temperature Setting Timer
Built-in Wireless Receiver Air Filter Cleaning Reminding Error Code Display Check
86mm
86mm
Specifications
Model Name HYXE-G01H
Power Supply DC 12~17 V
Outer Dimension 86X86X12.4mm
Max. Connectable IDU Number 1
38
High Intelligent
Control System
Wired Controller: HYE-Q01/ HYE-L01
Feature:
Technological Hisense
Main Functions
Cooling/Heating/Dry/Fan/Auto Fan Speed/Swing Louver Temperature Setting Timer
One Touch Test Run Air Filter Cleaning Reminding Error Code Display Check
QUIET
Press it to change to quiet mode. Repress it or “FAN” to exit.
SLEEP
Press it to change to sleep mode.
The default status is working in quiet mode for 8h. And in the first two hours, temperature will
increases 1℃/h in cooling mode, while decrease 1℃/h in heating mode. Also, we can reset the
sleep time and air flow in the sleep mode.
Time setting
60min.
Wide Control Angle 60min.
Cooling Operation 2C
Start temperature 1 C
Heating operation
Start temperature
1 C
2C
60min.
60min.
Time setting
Specifications
Model Name HYE-Q01 HYE-L01
Power Supply 2 AAA Batteries 2 AAA Batteries
Outer Dimension 125X55X16.5mm 148X60X17mm
Max. Connectable IDU Number 16 16
HYE-L01 can apply to all the indoor units, but it can only realize sleep and quiet function with the new wall mounted type.
39
High Intelligent
Control System
Receiver Kit for Wireless Control - Optional
Technological Hisense
Model Name Image Indoor unit Type Indoor unit Model
The "Room Card Control Function" of Hisense VRF indoor unit means control the on and off of the indoor unit through the room card.
When under function, the AC system is powered on. The room card can control whether the room lighting is powered on or off and also
can control the indoor unit on or off, which as a result can achieve switching off the lights and the AC and energy-saving by withdrawing
the room card when people leave.
40
High Intelligent
Control System
Features:
Error Reminder
Specifications
Model Name HYJ-J01H
Power Supply AC1Φ85~265V 50/60Hz
Outer Dimension 120X120X12.5mm
Max. Connectable IDU Number 128
Specifications
Model Name HYDE-E01H
Power Supply Central controller supply/ Indoor unit supply
Outer Dimension 120X120X20mm
Max. Connectable IDU Number ---
41
High Intelligent
Control System
Central Controller: HYJE-D02H
Technological Hisense
HYJE-D02H
Main Functions
Hotel
Lobby
Specifications
Model Name HYJE-D02H
Power Supply AC1Ф,220V,50/60Hz
Outer Dimension 120X120X20mm
Max. Connectable IDU Number 160
Max. Connectable Remote Control Groups 64
42
High Intelligent
Control System
Compatible to multiple communication protocol of BACnet, RS-485 etc. Connectible to BMS or Smart Home System via HC-A64BNP or
HLRSCON all of which can connect to Max. 64 indoor units.
BACnet HC-A64BNP
BACnet
(Ethernet(LAN))
Intranet
Intranet
Central Monitoring BMS
Air Conditioning
Hisense Supply
Air Conditioning
Air Conditioning
Central Station
Running-state Monitoring / On-off Setting Operating Mode Setting Temperature Setting and Monitoring
Airflow Setting and Monitoring Alarm Monitoring and Code Display Communication Failure Display
43
High Intelligent
Control System
RS-485 HLRSCON
Technological Hisense
Outdoor Units Indoor Units
RS-485(232)network
Hisense
BMS
HLRSCON
On-Off Setting Operating Mode Setting Airflow Setting and Monitoring Wind Setting and Monitoring
Temperature Setting Inlet Air Temp. Monitoring All Units On/Off Control Alarm Monitoring and Code Display
Converter Specifications
HC-A64BNP HLRSCON
Converter
Item
44
High Intelligent
Control System
Hi-Dom air conditioning management system adopts communication bus connection, air conditioning indoor units are connected to
the computer through network converter; the system is all controlled automatically by a computer with powerful functions and simple
operation. One single computer control system can manage 2,048 indoor units.
Main Functions
Running-state Monitoring Access Control
Determine the Temperature Limit Automatic Operation According to Settings
Running Records Display Multifunction Alarm
Controller Prohibition Function Service Monitoring
Adapter
Indoor unit
Outdoor
O td U
Unitit
Assistant remote
Wired controller Wireless remote Master remote
controller
controller controller
Indoor unit
Monitoring
Center
ications
Commun
network
Wired controller Wired controller
All the indoor units and outdoor units connected with one adapter comprise one communication BUS system .
Max.128 indoor units can be connected to a BUS system.
Max.16 adapters can be controlled by one computer.
Max.2048 indoor units are under control.
45
High Intelligent
Control System
Technological Hisense
Hisense electric charge allocation system consists of meter reading system and air conditioning management system. In accordance with
the operation time and capacity output of indoor and outdoor units, the opening degree of EEV, the electric charge allocation software
allocates the total power consumption to each indoor unit.
Note:Due to different laws and regulations in different regions, Hisense electrical charge calculation software need to customize
processing in project according to the users' requirement.
Electric meter
Adapter
AC system
Power supply
cable
Adapter
Adapter
Network connector
AC system
AC system
46
Product line-up
47
Hi-FLEXi Series
Hi-Smart Series
Indoor Unit
Total Heat Exchanger
AHU Solution
48
Hi-FLEXi G Series
Inverter Compressor
+
Inverter Compressor
Hi-FLEXi G series is the latest full DC inverter-driven multi-split central air conditioning product. It is the concentrated expression of
Hisense's R&D capacity and technical strength. Multiple advanced technology is adopted:
High efficiency high-pressure chamber scroll compressor
Latest DC inverter-driven control technique
Stepless fan speed regulation and fan production technology
Smart and precise unit capacity allocation technology
Intelligent Demand Mode control technology
-23℃ WB +19℃WB
-5℃ DB +50℃ DB
-25 -15 -5 5 15 25 35 45 55
49
Hi-FLEXi G Series
Product line-up
Streamlined air grille ◎Stepless frequency conversion adjustment of the fan
Fan speed
High 1050rpm
Stepless speed
regulation
Common speed
regulation
Low 0
VS
Hisense Hi-FlEXI G Series: Traditional product:
d
The efficiency will be the highest and the power consumption will be In normal operation, the module combination is operated at full load + ultra-low
lowest when each module unit is working at 40% - 75% partial load. load, which influences the service life of units and consumes more power.
50
Hi-FLEXi G Series
Max. 80Pa
The efficient axial fan is designed adopting CFD, finite element method, aviation dynamic fluid simulation analysis and other
advanced concepts; its air inlet angle and outlet angle are optimized; together with unique horn air vent design, the external static
pressure of outdoor unit is higher, which can better exhaust air and ensure smooth air flow.
For high-rise buildings, machine layer can be left to place outdoor units, or machine room can be set up on each floor. By using
exhaust duct to exhaust the air, short circuit of return air can be avoided with long exhaust distance, which ensures good
ventilation and heat exchange effects of outdoor units.
Temperature ℃
46.9443
45.4512
43.9582
42.4651
40.9721
39.4790
37.9859
36.4929
34.9998
Airflow Schematic Exhaust duct installation Layered installation effect picture
51
Hi-FLEXi G Series
Product line-up
Height difference between outdoor and indoor units: 70m ( when outdoor units are higher than indoor units )
Height difference between outdoor and indoor units: 90m ( when outdoor units are lower than indoor units )
Note:The recommended height difference between ODU and IDU: 50m when the ODU is higher than IDU; 40m when the ODU is lower than IDU
If the installation height difference is beyond the recommended value, please contact our technique engineer.
52
Hi-FLEXi G Series
8/10/12HP 14/16/18HP
Note:
1. Rated cooling capacity and rated heating capacity are tested in the following conditions:
Cooling conditions: indoor air inlet temperature: 27℃ DB 19℃ WB, Outdoor air inlet temperature: 35℃ DB, pipe length : 7.5m, pipe height difference: 0m
Heating conditions: indoor air inlet temperature: 20℃ DB, Outdoor air inlet temperature: 7℃ DB 6℃ WB, pipe length: 7.5m, pipe height difference : 0m
2.The above noise values are measured in the anechoic chamber without reflected echo, therefore the impact of the reflected echo must be included at the scene.
3.The final appearance of outdoor units is subject to the actual products.
53
Hi-FLEXi G Series
Product line-up
20HP 22/24/26HP
Note:
1. Rated cooling capacity and rated heating capacity are tested in the following conditions:
Cooling conditions: indoor air inlet temperature: 27℃ DB 19℃ WB, Outdoor air inlet temperature: 35℃ DB, pipe length : 7.5m, pipe height difference: 0m
Heating conditions: indoor air inlet temperature: 20℃ DB, Outdoor air inlet temperature: 7℃ DB 6℃ WB, pipe length: 7.5m, pipe height difference : 0m
2.The above noise values are measured in the anechoic chamber without reflected echo, therefore the impact of the reflected echo must be included at the scene.
3.The final appearance of outdoor units is subject to the actual products.
54
Hi-FLEXi G Series
28/30/32/34/36HP
Note:
1. Rated cooling capacity and rated heating capacity are tested in the following conditions:
Cooling conditions: indoor air inlet temperature: 27℃ DB 19℃ WB, Outdoor air inlet temperature: 35℃ DB, pipe length : 7.5m, pipe height difference: 0m
Heating conditions: indoor air inlet temperature: 20℃ DB, Outdoor air inlet temperature: 7℃ DB 6℃ WB, pipe length: 7.5m, pipe height difference : 0m
2.The above noise values are measured in the anechoic chamber without reflected echo, therefore the impact of the reflected echo must be included at the scene.
3.The final appearance of outdoor units is subject to the actual products.
55
Hi-FLEXi G Series
Product line-up
38/40/42HP
Note:
1. Rated cooling capacity and rated heating capacity are tested in the following conditions:
Cooling conditions: indoor air inlet temperature: 27℃ DB 19℃ WB, Outdoor air inlet temperature: 35℃ DB, pipe length : 7.5m, pipe height difference: 0m
Heating conditions: indoor air inlet temperature: 20℃ DB, Outdoor air inlet temperature: 7℃ DB 6℃ WB, pipe length: 7.5m, pipe height difference : 0m
2.The above noise values are measured in the anechoic chamber without reflected echo, therefore the impact of the reflected echo must be included at the scene.
3.The final appearance of outdoor units is subject to the actual products.
56
Hi-FLEXi G Series
44/46/48HP
Note:
1. Rated cooling capacity and rated heating capacity are tested in the following conditions:
Cooling conditions: indoor air inlet temperature: 27℃ DB 19℃ WB, Outdoor air inlet temperature: 35℃ DB, pipe length: 7.5m, pipe height difference: 0m
Heating conditions: indoor air inlet temperature: 20℃ DB, Outdoor air inlet temperature: 7℃ DB 6℃ WB, pipe length: 7.5m, pipe height difference : 0m
2.The above noise values are measured in the anechoic chamber without reflected echo, therefore the impact of the reflected echo must be included at the scene.
3.The final appearance of outdoor units is subject to the actual products.
57
Hi-FLEXi G Series
Product line-up
50/52/54HP
Note:
1. Rated cooling capacity and rated heating capacity are tested in the following conditions:
Cooling conditions: indoor air inlet temperature: 27℃ DB 19℃ WB, Outdoor air inlet temperature: 35℃ DB, pipe length : 7.5m, pipe height difference: 0m
Heating conditions: indoor air inlet temperature: 20℃ DB, Outdoor air inlet temperature: 7℃ DB 6℃ WB, pipe length: 7.5m, pipe height difference : 0m
2.The above noise values are measured in the anechoic chamber without reflected echo, therefore the impact of the reflected echo must be included at the scene.
3.The final appearance of outdoor units is subject to the actual products.
58
Hi-FLEXi G Series
(Ø26 x 4)
7 29
4-Holes
18
(38 x 15)
(235 x 113)
(Ø26 x 2)
213
Service Cover
Piping Connection
ØA Field-Supplied Pipe Size
1720
Q
185 Gas Line
Hole for
Power Supply Wiring
(Ø52 x 2)
60
Hole for
Refrigerant Piping and
Control Line Wiring
155 Gas Line
20
145
100
Viewed from Q
Hole for
Power Supply Wiring
(Ø52 x 2)
Hole for
Refrigerant Piping and
Control Line Wiring
NOTES:
AVWT-76UE(7)SRG
1. Drain water is discharged from the unit during the operation.
AVWT-96UE(7)SRG
a. Choose a place where well drainage is available. Provide a groove for drain.
AVWT-114UE(7)SRG
b. Do not provide an upward slope from the unit to avoid reverse flow of the drain.
Provide a second drain pan under the outdoor unit, to collect drain water securely.
c. Do not use the drain boss (optional) in a cold area. (Drain water in the drain pipe may be frozen and the drain pipe may crack.)
2. The dimensions marked with indicates the mounting pitch dimension for anchor bolts.
59
Hi-FLEXi G Series
Viewed from P
131 948 131
Product line-up
98 227 560 227 Hole for
105
18
Condensate Drain
(Ø26 x 4)
157
Power Supply Wiring
(Ø52)
Service Cover
213
Piping Connection
ØA Field-Supplied Pipe Size
1720
Q
325 Liquid Line
180 Gas Line
100
Hole for
P Power Supply Wiring
(Ø52 x 2)
60
Hole for
Refrigerant Piping and
Control Line Wiring
100
20
285 78 608
238 558 238 88 750
1210 765
Viewed from Q
Field Installation (Example)
Insulation
Accessory Pipe
Brazing
Anchor Bolt
(276)
(M12)
(Front Side)
(Rear Side)
Hole for
Power Supply Wiring (Standard)
less than 30
50
(Ø52 x 2)
70 Concrete
Foundation
Hole for
Refrigerant Piping and
Control Line Wiring
NOTES:
1. Drain water is discharged from the unit during the operation.
a. Choose a place where well drainage is available. Provide a groove for drain.
b. Do not provide an upward slope from the unit to avoid reverse flow of the drain.
AVWT-136UE(7)SSG 25.4 12.7
Provide a second drain pan under the outdoor unit, to collect drain water securely.
AVWT-154UE(7)SSG 28.6 12.7
c. Do not use the drain boss (optional) in a cold area. (Drain water in the drain pipe may be frozen and the drain pipe may crack.)
AVWT-170UE(7)SSG 28.6 15.88
2. The dimensions marked with indicates the mounting pitch dimension for anchor bolts.
60
Hi-FLEXi G Series
a
To Indoor Units
Refrigerant Piping
( ĭ mm)
a b b a
c c
To Indoor Units Manifold Pipe Manifold Pipe To Indoor Units
( ĭ mm)
AVWT- AVWT- AVWT- AVWT- AVWT- AVWT- AVWT- AVWT- AVWT-
Model
190UE(7)SZG 212UE(7)SZG 232UE(7)SZG 250UE(7)SZG 272UE(7)SZG 290UE(7)SZG 308UE(7)SZG 324UE(7)SZG 340UE(7)SZG
Outdoor AVWT- AVWT- AVWT- AVWT- AVWT- AVWT- AVWT- AVWT- AVWT-
Combination Unit A 76UE(7)SRG 76UE(7)SRG 96UE(7)SRG 114UE(7)SRG 136UE(7)SSG 136UE(7)SSG 154UE(7)SSG 154UE(7)SSG 170UE(7)SSG
Unit Outdoor AVWT- AVWT- AVWT- AVWT- AVWT- AVWT- AVWT- AVWT- AVWT-
Unit B 114UUE(7)SRG 136UE(7)SSG 136UE(7)SSG 136UE(7)SSG 136UE(7)SSG 154UE(7)SSG 154UE(7)SSG 170UE(7)SSG 170UE(7)SSG
Manifold Pipe HFQ-M22F HFQ-M32F
Gas 28.6 28.6 28.6 31.75 31.75 31.75 31.75 31.75 38.1
a
Liquid 15.88 15.88 15.88 19.05 19.05 19.05 19.05 19.05 19.05
Gas 25.4 25.4 25.4 25.4 25.4 28.6 28.6 28.6 28.6
Piping Size b
Liquid 12.7 12.7 12.7 12.7 12.7 12.7 12.7 15.88 15.88
Gas 19.05 19.05 22.2 25.4 25.4 25.4 28.6 28.6 28.6
c
Liquid 9.53 9.53 9.53 12.7 12.7 12.7 12.7 12.7 15.88
*
Refer to the table for the outdoor unit model, the manifold pipe model and the piping diameter.
61
Hi-FLEXi G Series
Product line-up
< Figure for AVWT-364UE(7)SZG >
Outdoor Unit A Outdoor Unit B Outdoor Unit C Outdoor Unit C Outdoor Unit B Outdoor Unit A
c d d c
a b d a
e e
( ĭ mm)
AVWT- AVWT- AVWT- AVWT- AVWT- AVWT- AVWT- AVWT- AVWT-
Model
364UE(7)SZG 382UE(7)SZG 398UE(7)SZG 420UE(7)SZG 438UE(7)SZG 454UE(7)SZG 476UE(7)SZG 494UE(7)SZG 510UE(7)SZG
Outdoor AVWT- AVWT- AVWT- AVWT- AVWT- AVWT- AVWT- AVWT- AVWT-
Unit A 114UE(7)SRG 114UE(7)SRG 114UE(7)SRG 114UE(7)SRG 114UE(7)SRG 114UE(7)SRG 136UE(7)SSG 154UE(7)SSG 170UE(7)SSG
Combination Outdoor AVWT- AVWT- AVWT- AVWT- AVWT- AVWT- AVWT- AVWT- AVWT-
Unit Unit B 114UE(7)SRG 114UE(7)SRG 114UE(7)SRG 136UE(7)SSG 154UE(7)SSG 170UE(7)SSG 170UE(7)SSG 170UE(7)SSG 170UE(7)SSG
Outdoor AVWT- AVWT- AVWT- AVWT- AVWT- AVWT- AVWT- AVWT- AVWT-
Unit C 136UE(7)SSG 154UE(7)SSG 170UE(7)SSG 170UE(7)SSG 170UE(7)SSG 170UE(7)SSG 170UE(7)SSG 170UE(7)SSG 170UE(7)SSG
Manifold Pipe HFQ-M32F+HFQ-M32F
Gas 38.1 38.1 38.1 38.1 38.1 38.1 38.1 38.1 38.1
a
Liquid 19.05 19.05 19.05 19.05 19.05 19.05 19.05 19.05 19.05
Gas 28.6 28.6 28.6 31.75 31.75 31.75 31.75 31.75 31.75
b
Liquid 15.88 15.88 15.88 19.05 19.05 19.05 19.05 19.05 19.05
Gas 25.4 28.6 28.6 28.6 28.6 28.6 28.6 28.6 28.6
Piping Size c
Liquid 12.7 12.7 15.88 15.88 15.88 15.88 15.88 15.88 15.88
Gas 25.4 25.4 25.4 25.4 28.6 28.6 28.6 28.6 28.6
d
Liquid 12.7 12.7 12.7 12.7 12.7 15.88 15.88 15.88 15.88
Gas 25.4 25.4 25.4 25.4 25.4 25.4 25.4 28.6 28.6
e
Liquid 12.7 12.7 12.7 12.7 12.7 12.7 12.7 12.7 15.88
*
Refer to the table for the outdoor unit model, the manifold pipe model and the piping diameter.
62
Hi-FLEXi M Series
Hisense VRF Hi-FLEXI M Series inverter air conditioning system adopt high efficiency scroll compressor and leading
frequency inverter control technology, realizing significant improvement in operation efficiency under partial load.
-20℃ WB +15.5℃WB
-5℃ DB +48℃ DB
-25 -15 -5 5 15 25 35 45 55
63
Hi-FLEXi M Series
Product line-up
Max. 60Pa
The efficient axial fan is designed adopting CFD, finite element method, aviation dynamic fluid simulation analysis and other
advanced concepts; its air inlet angle and outlet angle are optimized; together with unique horn air vent design, the external static
pressure of outdoor unit is higher, which can better exhaust air and ensure smooth air flow.
For high-rise buildings, machine layer can be left to place outdoor units, or machine room can be set up on each floor. By using
exhaust duct to exhaust the air, short circuit of return air can be avoided with long exhaust distance, which ensures good
ventilation and heat exchange effects of outdoor units.
Temperature ℃
46.9443
45.4512
43.9582
42.4651
40.9721
39.4790
37.9859
36.4929
34.9998
Airflow Schematic Exhaust duct installation Layered installation effect picture
64
Hi-FLEXi M Series
Height difference between outdoor and indoor units: 70m (when outdoor units are higher than indoor units)
Height difference between outdoor and indoor units: 90m (when outdoor units are lower than indoor units)
Note:The recommended height difference between ODU and IDU: 50m when the ODU is higher than IDU;40m when the ODU is lower than IDU
If the installation height difference is beyond the recommended value, please contact our technique engineer.
65
Hi-FLEXi M Series
Product line-up
8/10/12HP 14/16HP
NOTES:
1.The nominal cooling capacity and heating capacity are based on following conditions: 2. The sound pressure is based on the following conditions.1 Meter from the unit service
Cooling Operation Conditions cover surface, and 1.5 Meter from floor level. The above data is based on the cooling
Indoor Air Inlet Temperature: 27℃ DB(80°F DB), 19.0℃WB(66.2°F WB) mode. In case of heating mode, the sound pressure level increases by approximately 1
2dB. The above data was measured in an anechoic chamber so that reflected sound
Outdoor Air Inlet Temperature: 35℃ DB(95°F DB)
should be taken into consideration in the field.
Piping Length: 7.5 Meters Piping Lift: 0 Meter
Heating Operation Conditions 3. Except for the specified combination in the table, there is no other combination of the base unit.
Indoor Air Inlet Temperature: 20℃ DB(68°F DB), 4. The width of outer dimension, it is the value when each distance between the base
Outdoor Air Inlet Temperature: 7℃DB(45°F DB), 6℃WB(43°F WB) outdoor units is specified to 20mm.
66
Hi-FLEXi M Series
18/20HP 22/24/26HP
KW 53.2 56 61.5 68 73
Nominal Capacity
KBtu/h 181.5 191.1 209.8 232.0 249.1
Cooling Operation
Power Consumption KW 14.01 15.3 18.67 19.96 22.49
EER 3.80 3.66 3.29 3.41 3.25
KW 58.5 63 69 76.5 81.5
Nominal Capacity
KBtu/h 199.6 215.0 235.4 261.0 278.1
Heating Opeartion
Power Consumption KW 14.3 15.52 18.09 19.31 21.67
COP 4.09 4.06 3.98 3.96 3.81
Air Flow Rate m³/h 19,500 20,400 21,000 21,900 22,200
Outer Dimension mm 1,720×(950+950)×750 1,720×(950+1,210)×750
Packing Dimension mm --- --- --- --- ---
Net Weight Kg 223+225 225+225 223+295 225+295 225+295
Gross Weight Kg 235+237 237×2 235+310 237+310 255+310
Compressor Quantity 2 2 3 3 3
Condenser Fan Quantity 2 2 2 2 2
Cabinet Color Ivory White Ivory White
Gas Line mm φ28.6 φ28.6 φ28.6 φ28.6 φ31.75
Refrigerant Piping
Liquid Line mm φ15.88 φ15.88 φ15.88 φ15.88 φ19.05
Max. number of connectable IDU 26 33 36 40 43
Max. Piping Length m 165 165 165 165 165
Between ODU&IDU m 70(90) 70(90) 70(90) 70(90) 70(90)
Height Difference
Between IDUs m 15 15 15 15 15
Noise Level dB(A) 61 61 62 63 63
Cooling ℃ DB -5 ~48℃ -5 ~48℃ -5 ~48℃ -5 ~48℃ -5 ~48℃
Operation Range
Heating ℃ WB -20~ 15.5℃ -20~ 15.5℃ -20~ 15.5℃ -20~ 15.5℃ -20~ 15.5℃
NOTES:
1.The nominal cooling capacity and heating capacity are based on following conditions: 2. The sound pressure is based on the following conditions.1 Meter from the unit service
Cooling Operation Conditions cover surface, and 1.5 Meter from floor level. The above data is based on the cooling
Indoor Air Inlet Temperature: 27℃ DB(80°F DB), 19.0℃WB(66.2°F WB) mode. In case of heating mode, the sound pressure level increases by approximately 1
2dB. The above data was measured in an anechoic chamber so that reflected sound
Outdoor Air Inlet Temperature: 35℃ DB(95°F DB)
should be taken into consideration in the field.
Piping Length: 7.5 Meters Piping Lift: 0 Meter
Heating Operation Conditions 3. Except for the specified combination in the table, there is no other combination of the base unit.
Indoor Air Inlet Temperature: 20℃ DB(68°F DB), 4. The width of outer dimension, it is the value when each distance between the base
Outdoor Air Inlet Temperature: 7℃DB(45°F DB), 6℃WB(43°F WB) outdoor units is specified to 20mm.
67
Hi-FLEXi M Series
Product line-up
28/30/32HP
KW 78.5 85 90
Nominal Capacity
KBtu/h 267.8 290.0 307.1
Cooling Operation
Power Consumption KW 24.62 26.24 27.86
EER 3.17 3.24 3.23
KW 87.5 95 100
Nominal Capacity
KBtu/h 298.6 324.1 341.2
Heating Opeartion
Power Consumption KW 23.1 24.37 25.64
COP 3.90 3.90 3.90
Air Flow Rate m³/h 23,400 23,400 23,400
Outer Dimension mm 1,720×(1,210+1,210)×750
Packing Dimension mm --- --- ---
Net Weight Kg 295+295 295+310 310+310
Gross Weight Kg 310+310 310+325 325+325
Compressor Quantity 4 4 4
Condenser Fan Quantity 2 3 3
Cabinet Color Ivory White
Gas Line mm φ31.75 φ31.75 φ31.75
Refrigerant Piping
Liquid Line mm φ19.05 φ19.05 φ19.05
Max. number of connectable IDU 47 50 53
Max. Piping Length m 165 165 165
Between ODU&IDU m 70(90) 70(90) 70(90)
Height Difference
Between IDUs m 15 15 15
Noise Level dB(A) 63 63 63
Cooling ℃ DB -5 ~48℃ -5 ~48℃ -5 ~48℃
Operation Range
Heating ℃ WB -20~15.5℃ -20 ~15.5℃ -20~15.5℃
NOTES:
1.The nominal cooling capacity and heating capacity are based on following conditions: 2. The sound pressure is based on the following conditions.1 Meter from the unit service
Cooling Operation Conditions cover surface, and 1.5 Meter from floor level. The above data is based on the cooling
Indoor Air Inlet Temperature: 27℃ DB(80°F DB), 19.0℃WB(66.2°F WB) mode. In case of heating mode, the sound pressure level increases by approximately 1
2dB. The above data was measured in an anechoic chamber so that reflected sound
Outdoor Air Inlet Temperature: 35℃ DB(95°F DB)
should be taken into consideration in the field.
Piping Length: 7.5 Meters Piping Lift: 0 Meter
Heating Operation Conditions 3. Except for the specified combination in the table, there is no other combination of the base unit.
Indoor Air Inlet Temperature: 20℃ DB(68°F DB), 4. The width of outer dimension, it is the value when each distance between the base
Outdoor Air Inlet Temperature: 7℃DB(45°F DB), 6℃WB(43°F WB) outdoor units is specified to 20mm.
68
Hi-FLEXi M Series
34/36/38/40HP
NOTES:
1.The nominal cooling capacity and heating capacity are based on following conditions: 2. The sound pressure is based on the following conditions.1 Meter from the unit service
Cooling Operation Conditions cover surface, and 1.5 Meter from floor level. The above data is based on the cooling
Indoor Air Inlet Temperature: 27℃ DB(80°F DB), 19.0℃WB(66.2°F WB) mode. In case of heating mode, the sound pressure level increases by approximately 1
2dB. The above data was measured in an anechoic chamber so that reflected sound
Outdoor Air Inlet Temperature: 35℃ DB(95°F DB)
should be taken into consideration in the field.
Piping Length: 7.5 Meters Piping Lift: 0 Meter
Heating Operation Conditions 3. Except for the specified combination in the table, there is no other combination of the base unit.
Indoor Air Inlet Temperature: 20℃ DB(68°F DB), 4. The width of outer dimension, it is the value when each distance between the base
Outdoor Air Inlet Temperature: 7℃DB(45°F DB), 6℃WB(43°F WB) outdoor units is specified to 20mm.
69
Hi-FLEXi M Series
Product line-up
42/44HP 46/48HP
NOTES:
1.The nominal cooling capacity and heating capacity are based on following conditions: 2. The sound pressure is based on the following conditions.1 Meter from the unit service
Cooling Operation Conditions cover surface, and 1.5 Meter from floor level. The above data is based on the cooling
Indoor Air Inlet Temperature: 27℃ DB(80°F DB), 19.0℃WB(66.2°F WB) mode. In case of heating mode, the sound pressure level increases by approximately 1
2dB. The above data was measured in an anechoic chamber so that reflected sound
Outdoor Air Inlet Temperature: 35℃ DB(95°F DB)
should be taken into consideration in the field.
Piping Length: 7.5 Meters Piping Lift: 0 Meter
Heating Operation Conditions 3. Except for the specified combination in the table, there is no other combination of the base unit.
Indoor Air Inlet Temperature: 20℃ DB(68°F DB), 4. The width of outer dimension, it is the value when each distance between the base
Outdoor Air Inlet Temperature: 7℃DB(45°F DB), 6℃WB(43°F WB) outdoor units is specified to 20mm.
70
Hi-FLEXi M Series
Viewed from P
131 688 131
Product line-up
105
18
Condensate Drain
(Ø26 x 4)
Hole for
729
157
Power Supply Wiring
(Ø52)
4-Holes
18
Service Cover
Piping Connection
ØA Field-Supplied Pipe Size
1720
Q
185 Gas Line
Hole for
P Power Supply Wiring
(Ø52 x 2)
60
Hole for
Refrigerant Piping and
Control Line Wiring
155 Gas Line
20
145
100
Viewed from Q
Field Installation (Example)
Accessory Pipe
Insulation
Brazing
(295)
Anchor Bolt
(M12)
(Front Side) (Rear Side)
Hole for
(Standard)
50
(Ø52 x 2) Concrete
70
Foundation
Hole for
Refrigerant Piping and
Control Line Wiring
NOTES:
1. Drain water is discharged from the unit during the operation. Dimension
a. Choose a place where well drainage is available. Provide a groove for drain. A C
Model
b. Do not provide an upward slope from the unit to avoid reverse flow of the drain. AVWT-86U6(B)(7)SR
AVWT-86U6(7)SR 19.05 9.53
Provide a second drain pan under the outdoor unit, to collect drain water securely. AVWT-96U6(7)SR
AVWT-96U6(B)(7)SR 22.2 9.53
c. Do not use the drain boss (optional) in a cold area. (Drain water in the drain pipe may be frozen and the drain pipe may crack.) AVWT-114U6(B)(7)SR
AVWT-114U6(7)SR 25.4 12.7
2. The dimensions marked with indicates the mounting pitch dimension for anchor bolts.
71
Hi-FLEXi M Series
Viewed from P
131 948 131 98 227 560 227 Hole for
Product line-up
105
18
Condensate Drai
(Ø26 x 4)
Hole for
729
157
Power Supply Wiring
(Ø52)
Service Cover
213
Piping Connection
ØA Field-Supplied Pipe Size
1720
Q
325 Liquid Line
180 Gas Line
100
Hole for
P Power Supply Wiring
(Ø52 x 2)
60
Hole for
Refrigerant Piping and
Control Line Wiring
100
20
285 78 608
238 558 238 88 750
1210 765
Viewed from Q
Field Installation (Example)
Insulation
Accessory Pipe
Brazing
Anchor Bolt
(276)
(M12)
(Front Side)
(Rear Side)
Hole for
Power Supply Wiring (Standard)
less than 30
50
(Ø52 x 2)
70 Concrete
Foundation
Hole for
Refrigerant Piping and
Control Line Wiring
NOTES:
1. Drain water is discharged from the unit during the operation.
a. Choose a place where well drainage is available. Provide a groove for drain. Dimension
b. Do not provide an upward slope from the unit to avoid reverse flow of the drain. A C
Model
Provide a second drain pan under the outdoor unit, to collect drain water securely. AVWT-136U6(7)SS
U6(B)(7) 25.4 12.7
c. Do not use the drain boss (optional) in a cold area. (Drain water in the drain pipe may be frozen and the drain pipe may crack.) AVWT-154U6(7)SS
U6(B)(7) 28.6 12.7
2. The dimensions marked with indicates the mounting pitch dimension for anchor bolts.
72
Hi-FLEXi M Series
a
To Indoor Units
Refrigerant Piping
(ĭmm)
a b b a
c c
To Indoor Units Manifold Pipe Manifold Pipe To Indoor Units
(ĭmm)
*
Refer to the table for the outdoor unit model, the manifold pipe model and the piping diameter.
73
Hi-FLEXi M Series
Product line-up
(Indoor Unit on Left Side) (Indoor Unit on Right Side)
Outdoor Unit A Outdoor Unit B Outdoor Unit C Outdoor Unit C Outdoor Unit B Outdoor Unit A
c d d c
a b d a
e e
(ĭmm)
*
Refer to the table for the outdoor unit model, the manifold pipe model and the piping diameter.
74
Hi-FLEXi R Series
The latest heat recovery multi-split system achieves indoor units cooling and heating at the same time and being switched between
two modes individually,which flexibly satisfies personalized need of different users.
75
Hi-FLEXi R Series
Product line-up
instead of via switch box unit will stick to cooling only operation.
Switch Box
-20℃ WB +15.5℃WB
-5℃ DB +48℃ DB
-25 -15 -5 5 15 25 35 45 55
76
Hi-FLEXi R Series
Max. 60Pa
The efficient axial fan is designed adopting CFD, finite element method, aviation dynamic fluid simulation analysis and other
advanced concepts; its air inlet angle and outlet angle are optimized; together with unique horn air vent design, the external static
pressure of outdoor unit is higher, which can better exhaust air and ensure smooth air flow.
Temperature ℃
46.9443
45.4512
43.9582
42.4651
40.9721
39.4790
37.9859
36.4929
34.9998
Airflow Schematic Exhaust duct installation Layered installation effect picture
77
Hi-FLEXi R Series
Product line-up
Max. equivalent piping length: 190m
Height difference between the highest and lowest indoor units: 15m or less
Max.height difference between outdoor and indoor units: 70m (when outdoor units are higher than indoor units)
Max.height difference between outdoor and indoor units: 90m (when outdoor units are lower than indoor units)
Max.height
difference between
outdoor units Max.height difference between
and indoor Indoor units Switch Box: 15m
units: 70m Piping
Switch Box
Max.distance between
the 1st branch and Max.height between indoor units after
indoor unit: 90m
the same Switch Box: 3m
Note:The recommended height difference between ODU and IDU: 50m when the ODU is higher than IDU;40m when the ODU is lower than IDU
If the installation height difference is beyond the recommended value, please contact our technique engineer.
78
Hi-FLEXi R Series
8/10/12HP 14/16/18HP
Combination
NOTES:
1.The nominal cooling capacity and heating capacity are based on following conditions: 2. The sound pressure is based on the following conditions.1 Meter from the unit service
Cooling Operation Conditions cover surface, and 1.5 Meter from floor level. The above data is based on the cooling
Indoor Air Inlet Temperature: 27℃ DB(80°F DB), 19.0℃WB(66.2°F WB) mode. In case of heating mode, the sound pressure level increases by approximately 1
2dB. The above data was measured in an anechoic chamber so that reflected sound
Outdoor Air Inlet Temperature: 35℃ DB(95°F DB)
should be taken into consideration in the field.
Piping Length: 7.5 Meters Piping Lift: 0 Meter
Heating Operation Conditions 3. Except for the specified combination in the table, there is no other combination of the base unit.
Indoor Air Inlet Temperature: 20℃ DB(68°F DB), 4. The width of outer dimension, it is the value when each distance between the base
Outdoor Air Inlet Temperature: 7℃DB(45°F DB), 6℃WB(43°F WB) outdoor units is specified to 20mm.
79
Hi-FLEXi R Series
Product line-up
20HP 22/24/26HP
NOTES:
1.The nominal cooling capacity and heating capacity are based on following conditions: 2. The sound pressure is based on the following conditions.1 Meter from the unit service
Cooling Operation Conditions cover surface, and 1.5 Meter from floor level. The above data is based on the cooling
Indoor Air Inlet Temperature: 27℃ DB(80°F DB), 19.0℃WB(66.2°F WB) mode. In case of heating mode, the sound pressure level increases by approximately 1
2dB. The above data was measured in an anechoic chamber so that reflected sound
Outdoor Air Inlet Temperature: 35℃ DB(95°F DB)
should be taken into consideration in the field.
Piping Length: 7.5 Meters Piping Lift: 0 Meter
Heating Operation Conditions 3. Except for the specified combination in the table, there is no other combination of the base unit.
Indoor Air Inlet Temperature: 20℃ DB(68°F DB), 4. The width of outer dimension, it is the value when each distance between the base
Outdoor Air Inlet Temperature: 7℃DB(45°F DB), 6℃WB(43°F WB) outdoor units is specified to 20mm.
80
Hi-FLEXi R Series
28/30/32/34/36HP
NOTES:
1.The nominal cooling capacity and heating capacity are based on following conditions: 2. The sound pressure is based on the following conditions.1 Meter from the unit service
Cooling Operation Conditions cover surface, and 1.5 Meter from floor level. The above data is based on the cooling
Indoor Air Inlet Temperature: 27℃ DB(80°F DB), 19.0℃WB(66.2°F WB) mode. In case of heating mode, the sound pressure level increases by approximately 1
2dB. The above data was measured in an anechoic chamber so that reflected sound
Outdoor Air Inlet Temperature: 35℃ DB(95°F DB)
should be taken into consideration in the field.
Piping Length: 7.5 Meters Piping Lift: 0 Meter
Heating Operation Conditions 3. Except for the specified combination in the table, there is no other combination of the base unit.
Indoor Air Inlet Temperature: 20℃ DB(68°F DB), 4. The width of outer dimension, it is the value when each distance between the base
Outdoor Air Inlet Temperature: 7℃DB(45°F DB), 6℃WB(43°F WB) outdoor units is specified to 20mm.
81
Hi-FLEXi R Series
Product line-up
38/40/42HP
NOTES:
1.The nominal cooling capacity and heating capacity are based on following conditions: 2. The sound pressure is based on the following conditions.1 Meter from the unit service
Cooling Operation Conditions cover surface, and 1.5 Meter from floor level. The above data is based on the cooling
Indoor Air Inlet Temperature: 27℃ DB(80°F DB), 19.0℃WB(66.2°F WB) mode. In case of heating mode, the sound pressure level increases by approximately 1
2dB. The above data was measured in an anechoic chamber so that reflected sound
Outdoor Air Inlet Temperature: 35℃ DB(95°F DB)
should be taken into consideration in the field.
Piping Length: 7.5 Meters Piping Lift: 0 Meter
Heating Operation Conditions 3. Except for the specified combination in the table, there is no other combination of the base unit.
Indoor Air Inlet Temperature: 20℃ DB(68°F DB), 4. The width of outer dimension, it is the value when each distance between the base
Outdoor Air Inlet Temperature: 7℃DB(45°F DB), 6℃WB(43°F WB) outdoor units is specified to 20mm.
82
Hi-FLEXi R Series
44/46/48HP
NOTES:
1.The nominal cooling capacity and heating capacity are based on following conditions: 2. The sound pressure is based on the following conditions.1 Meter from the unit service
Cooling Operation Conditions cover surface, and 1.5 Meter from floor level. The above data is based on the cooling
Indoor Air Inlet Temperature: 27℃ DB(80°F DB), 19.0℃WB(66.2°F WB) mode. In case of heating mode, the sound pressure level increases by approximately 1
2dB. The above data was measured in an anechoic chamber so that reflected sound
Outdoor Air Inlet Temperature: 35℃ DB(95°F DB)
should be taken into consideration in the field.
Piping Length: 7.5 Meters Piping Lift: 0 Meter
Heating Operation Conditions 3. Except for the specified combination in the table, there is no other combination of the base unit.
Indoor Air Inlet Temperature: 20℃ DB(68°F DB), 4. The width of outer dimension, it is the value when each distance between the base
Outdoor Air Inlet Temperature: 7℃DB(45°F DB), 6℃WB(43°F WB) outdoor units is specified to 20mm.
83
Hi-FLEXi R Series
Product line-up
50/52/54HP
NOTES:
1.The nominal cooling capacity and heating capacity are based on following conditions: 2. The sound pressure is based on the following conditions.1 Meter from the unit service
Cooling Operation Conditions cover surface, and 1.5 Meter from floor level. The above data is based on the cooling
Indoor Air Inlet Temperature: 27℃ DB(80°F DB), 19.0℃WB(66.2°F WB) mode. In case of heating mode, the sound pressure level increases by approximately 1
2dB. The above data was measured in an anechoic chamber so that reflected sound
Outdoor Air Inlet Temperature: 35℃ DB(95°F DB)
should be taken into consideration in the field.
Piping Length: 7.5 Meters Piping Lift: 0 Meter
Heating Operation Conditions 3. Except for the specified combination in the table, there is no other combination of the base unit.
Indoor Air Inlet Temperature: 20℃ DB(68°F DB), 4. The width of outer dimension, it is the value when each distance between the base
Outdoor Air Inlet Temperature: 7℃DB(45°F DB), 6℃WB(43°F WB) outdoor units is specified to 20mm.
84
Hi-FLEXi R Series
Viewed from P
98 227 300 227 Hole for
105
131 688 131 Condensate Drain
Product line-up
(Ø26 x 4)
18
Hole for
157
Power Supply Wiring
729
(Ø52)
Service Cover
(High Pressure)
ØB Field-Supplied Pipe Size
345 Liquid Line
Q
185 Gas Line
100
Hole for
P Power Supply Wiring
(Ø52 x 2)
60
Hole for
Refrigerant Piping and
Control Line Wiring
20
145
100
Accessory Pipe
Insulation
Brazing
(295)
Anchor Bolt
(M12)
(Front Side) (Rear Side)
(Standard)
50
less than 30
Provide a second drain pan under the outdoor unit, to collect drain water securely. AVWT-76FESR 19.05 15.88 9.53
AVWT-96FESR 22.2 19.05 9.53
c. Do not use the drain boss (optional) in a cold area. (Drain water in the drain pipe may be frozen and the drain pipe may crack.)
AVWT-114FESR 25.4 22.2 12.7
2. The dimensions marked with indicates the mounting pitch dimension for anchor bolts.
85
Hi-FLEXi R Series
105
Condensate Drain
18
(Ø26 x 4)
Product line-up
Hole for
157
729
Power Supply Wiring
(Ø52)
Service Cover
213
(High Pressure)
ØB Field-Supplied Pipe Size Q
325 Liquid Line
180 Gas Line
100
Hole for
P Power Supply Wiring
(Ø52 x 2)
60
Hole for
Refrigerant Piping and
Control Line Wiring
100
20
285 78 608
238 558 238 88 750
1210 765
Viewed from Q
Field Installation (Example)
Insulation
Accessory Pipe
Brazing
Anchor Bolt
(276)
(M12)
(Front Side)
(Rear Side)
Hole for
Power Supply Wiring (Standard)
less than 30
50
(Ø52 x 2)
70 Concrete
Foundation
86
Hi-FLEXi R Series
a
To Indoor Units
Refrigerant Piping
(ĭ mm)
a b b a
c c
To Indoor Units Manifold Pipe Manifold Pipe To Indoor Units
(ĭmm)
Model AVWT-190FESZ AVWT-212FESZ AVWT-232FESZ AVWT-250FESZ AVWT-272FESZ AVWT-290FESZ AVWT-308FESZ AVWT-324FESZ AVWT-340FESZ
Outdoor
AVWT-114FESR AVWT-136FESS AVWT-136FESS AVWT-136FESS AVWT-136FESS AVWT-154FESS AVWT-154FESS AVWT-170FESS AVWT-170FESS
Combination Unit A
Unit Outdoor
AVWT-76FESR AVWT-76FESR AVWT-96FESR AVWT-114FESR AVWT-136FESS AVWT-136FESS AVWT-154FESS AVWT-154FESS AVWT-170FESS
Unit B
Manifold Pipe HFQ-M22F HFQ-M32F
Gas 28.6 28.6 28.6 31.75 31.75 31.75 31.75 31.75 38.1
a
Liquid 15.88 15.88 15.88 19.05 19.05 19.05 19.05 19.05 19.05
Gas 25.4 25.4 25.4 25.4 25.4 28.6 28.6 28.6 28.6
Piping Size b
Liquid 12.7 12.7 12.7 12.7 12.7 12.7 12.7 15.88 15.88
Gas 19.05 19.05 22.2 25.4 25.4 25.4 28.6 28.6 28.6
c
Liquid 9.53 9.53 9.53 12.7 12.7 12.7 12.7 12.7 15.88
*
Refer to the table for the outdoor unit model, the manifold pipe model and the piping diameter.
87
Hi-FLEXi R Series
Product line-up
(Indoor Unit on Left Side) (Indoor Unit on Right Side)
Outdoor Unit A Outdoor Unit B Outdoor Unit C Outdoor Unit C Outdoor Unit B Outdoor Unit A
c d d c
a b d a
e e
(ĭmm)
*
Refer to the table for the outdoor unit model, the manifold pipe model and the piping diameter.
88
Hi-FLEXi W Series
89
Hi-FLEXi W Series
Product line-up
High Efficiency, Superb Model COP 30%
90
Hi-FLEXi W Series
sections, easily satisfies the requirement of simultaneous cooling and heating in the same building, realizes heat recovery and
maximum energy-saving.
Heat Exhaust
Cooling
Cooling
Heat Exhaust
Heating
Heat Suction
Cooling
Heat Exhaust
Heat Recovery Among Different Floors Heat Recovery on the Same Floor
*Heat recovery is achieved by taking water as heat carrier among multiple units connected to the same water circulation system.
Stable Performance
By the use of water source and soil source, the performance of Hi-FLEXi W
series will not be affected by high temperature. Even if in hot summer, its Constant
Water Temp.
cooling capacity will not attenuate. Likewise, in heating operation,practically, the
heat source temperature is higher and relatively uniform, so that the frosting
and defrosting will not occur, which contributes to stable performance. No effect on System
3-6HP:H800XW800XD370mm 8-10HP:H1000XW780XD550mm
91
Hi-FLEXi W Series
Product line-up
3200mm
or more
The same module size helps realize modular combination, and
multiple units can be stacked
about 2,000mm
about 1,000mm
①
③ Model 3HP 4/5/6HP 8/10/16/18/20HP
Max.Height Difference
5 15 15
Between Indoor Units
92
Hi-FLEXi W Series
NOTES:
*1. Operation Condition:
Cooling:Indoor Temperature 27℃ DB/19℃ WB,Outdoor Temperature 27℃ DB,Water Inlet/Outlet 30/35℃.
Heating:Indoor Temperature 20℃ DB/15℃ WB,Outdoor Temperature 20℃ DB,Water Inlet 20℃.
*2. The above data was measured in an anechoic chamber so that reflected sound should be taken into consideration in the field.
*3. When unit is operating out of the allowable water temperature range, it won’t start normally and will alarm.
93
Hi-FLEXi W Series
Product line-up
AC3Ф, 380~ 415V/50Hz AVWW-76UESB AVWW-96UESB AVWW-154UCSB AVWW-170UCSB AVWW-190UCSB
Model Power Supply
AC3Ф, 380V/60Hz AVWW-76U7SB AVWW-96U7SB AVWW-154U7SB AVWW-170U7SB AVWW-190U7SB
KW 22.40 28.00 45.00 50.00 56.00
Nominal Capacity*1
KBtu/h 76.5 95.6 153.6 170.6 191.1
Cooling Operation KW
Rated Input 4.42 6.26 8.84 10.68 12.52
EER 5.07 4.77 5.07 4.68 4.47
KW 25.00 31.50 50.00 56.00 63.00
Nominal Capacity*1
KBtu/h 85.3 107.5 170.6 191.1 215.0
Heating Opeartion
Rated Input KW 4.2 5.81 8.4 10.01 11.62
COP 6.00 5.42 5.95 5.95 5.42
Height mm 1000 1000 1000 1000 1000
Width mm 780 780 780+780 780+780 780+780
Outer Dimensions
Depth mm 550 550 550 550 550
Aera m² 0.4 0.4 0.86 0.86 0.86
Packing Dimensions mm 850X600X1,120 850X600X1,120 -- -- --
Net Weight Kg 160 160 160+160 160+160 160+160
Gross Weight Kg 165 165 165+165 165+165 165+165
Water Temperature*3 ℃ 10 ~ 45 10 ~ 45 10 ~ 45 10 ~ 45 10 ~ 45
Water-Side Heat Exchanger Water Flow Rate l/min 76.8 96 153.6 172.8 192
Water Pressure Drop KPa 35 40 35 40 40
Sound Pressure Level *2 Cooling/Heating dB(A) 50 51 51 51 52
Refrigerant Liquid Pipe mm Ф12.7 Ф12.7 Ф15.88 Ф15.88 Ф15.88
Refrigerant Gas Pipe mm Ф19.05 Ф22.2 Ф28.6 Ф28.6 Ф28.6
Piping Connection Water Pipe DN32 DN32 DN32 DN32 DN32
Thread of Connector G1 1/4B G1 1/4B G1 1/4B G1 1/4B G1 1/4B
Drain Pipe mm Ф18 Ф18 Ф18 Ф18 Ф18
Water-Side Bearing Pressure Ability Kgf/cm 20 20 20 20 20
Max. Connectable Indoor Units 13 16 20 20 20
NOTES:
*1. Operation Condition:
Cooling:Indoor Temperature 27℃ DB/19℃ WB,Outdoor Temperature 27℃ DB,Water Inlet/Outlet 30/35℃.
Heating:Indoor Temperature 20℃ DB/15℃ WB,Outdoor Temperature 20℃ DB,Water Inlet 20℃.
*2. The above data was measured in an anechoic chamber so that reflected sound should be taken into consideration in the field.
*3. When unit is operating out of the allowable water temperature range, it won’t start normally and will alarm.
94
Hi-FLEXi W Series
95
Hi-FLEXi W Series
Product line-up
Viewed from A
4-Holes
Water Inlet
96
Hi-FLEXi C Series
Air Outlet
Hi-FLEXI C series
Heat Exchanger
Heat Exchanger
DC Fan Motor
The smooth rotating fan motor with low
vibration reduces the noise level. Super High-stream Fan DC Fan Motors
97
Hi-FLEXi C Series
Features
Provide in a compact body, but allows installation conditions comparable with those of a high-performance multi-split air condition-
ing system.
The compact and light body facilitates delivery and installation.
Product line-up
The adoption of a slim body improves flexibility in mounting, enabling installation in a small space or a formerly dead space.
98
Hi-FLEXi C Series
With its light and compact body, the Hi-FLEXi C Series can be
easily carried in the elevator even in a small urban site.
Light and compact body
No cranes required for delivery facilitates renewal
99
Hi-FLEXi C Series
The piping can be designed and constructed up to a total Piping length 100m (total piping length of 250m)
Product line-up
Piping length: 100 m(Equivalent length :125m)
Max. height difference between ODU and IDU Outdoor unit is higher: 50m Indoor unit is higher : 40m
4 5
3
1
100
Hi-FLEXi C Series
101
Hi-FLEXi C Series
Product line-up
AVW-76UE(7)SR
AVW-96UE(7)SR
AVW-114UE(7)SR
AVW-76UE(7)SR
102
Hi-Smart L Series
Free Combination
One outdoor unit of Hi-Smart L series can connect maximum 7 indoor units in different types. The free combination not only
Product line-up
meets the air condition needs of large space, but also helps match the indoor decoration. Flexible choice and better system
configuration start a tour of Luxury life.
Refrigerant Pipe
Drain Pipe
103
Hi-Smart L Series
Max. height difference between the highest and the lowest indoor units is 10m.
Product line-up
Max. height difference between outdoor and indoor units is 30m.
Max. piping length is 75m.
Total piping length can be 120m.
Max. 75m
30m
10m
1104
10
04
Hi-Smart L Series
Hi-Smart L series HP 4 5 6
AC1Φ, 220 ~240V/50Hz AVW-38UCSC AVW-48UCSC AVW-54UCSC
AC1Φ, 220V/60Hz AVW-38U2SC AVW-48U2SC AVW-54U2SC
Model Power Supply
AC3Φ, 380 ~415V/50Hz --- AVW-48UESC AVW-54UESC
AC3Φ, 380V/60Hz --- AVW-48U7SC AVW-54U7SC
Kw 11.2 14.0 15.5
Nominal Capacity
KBtu/h 38.2 47.8 52.9
Cooling Operation
Power Consumption KW 2.99 3.92 4.44
EER 3.75 3.57 3.49
KW 12.5 16.0 18.0
Nominal Capacity
KBtu/h 42.7 54.6 61.4
Heating Opeartion
Power Consumption KW 2.98 4.03 4.74
COP 4.19 3.97 3.80
Air Flow Rate m³/h 5,400 5,400 6,000
Outer Dimension mm 1,380×950×370
Packing Dimension mm 1,040×460×1,500
Net Weight Kg 93 95 97
Gross Weight Kg 106 108 110
Liquid Line mm Φ9.53 Φ9.53 Φ9.53
Refrigerant Piping
Gas Line mm Φ15.88 Φ15.88 Φ15.88
Max. number of connectable IDU 6 7 7
Noise Level Cooling/Heating dB(A) 52/54 52/55 54/56
Cooling Operation ℃ DB -5~46℃DB
Operation Range
Heating Operation ℃ WB -20~15.5℃WB
Branch Pipe HFQ-052F
NOTES:
2. The sound pressure lever is based on following
1.The nominal cooling capacity and heating capacity are based on following conditions:
Cooling Operation Conditions conditions.1.5m beneath the unit.
Indoor Air Inlet Temperature: 27℃ DB(80ºF DB) Heating Operation Conditions The above date was measured in an anechoic
19.0℃ WB(66.2ºF WB) Indoor Air Inlet Temperature: 20℃ DB(68ºF DB) chamber so that reflected sound should be taken
Outdoor Air Inlet Temperature: 35℃ DB(95ºF DB) Outdoor Air Inlet Temperature: 7℃ DB(45ºF DB) into consideration in the field.
Piping Length: 7.5Meters Piping Lift: 0 Meter 6℃ WB(43ºF WB)
105
Hi-Smart L Series
NOTES:
1.Stop valve is installed in the hood.
2.The interval dimension between fixed bolts for installation is 600×410.
106
Hi-Smart E Series
1
Intelligent and
5
Intelligent Defrosting
High Efficient Technology
2 4
DC Inverter-driven
Technology 3
Low Noise and
3D Temperature
Control Technology
Drain Pipe
107
Hi-Smart E Series
Product line-up
192mm
NOTES: 2.0m
Hi-Smart E Series has 3 types of indoor units for selection:
Low-height ceiling ducted type
Slim ceiling ducted type
Wall mounted type
108
Hi-Smart E Series
Hi-Smart E series HP 3 4 5
AC1Φ, 220 ~240V/50Hz AVW-28UCSB AVW-34UCSB AVW-43UCSB
NOTES:
1.The nominal cooling and heating capacities show the capacities when the outdoor with the 100% rating of indoor unit.
Cooling Operation Conditions
Indoor Air Inlet Temperature:27℃DB/19℃WB
Outdoor Air Inlet Temperature:35℃DB
Piping Length:7.5Meters Piping Lift:0 Meter
2.The sound pressure level is based on following conditions:
1.5 Meters from floor Level,and 1Meter from the unit service cover surface.
The above data was measured in an anechoic chamber so that reflected sounde shoudle be taken into consideration in the field.
109
Hi-Smart E Series
AVW-28~43UC(2)SB Unit: mm
Product line-up
Piping and Wiring Hole
Ground
Air Outlet
Note:
1. The unit is equipped with stop valve; field refrigerant pipes are connected to stop valve through flare opening.
2. Illustrated 110 dimension marked with ** is to avoid possible conflict with the foundation, etc. in piping from the bottom.
3. Dimension marked with * is the location dimension of anchor holes.
Service Space
110
Indoor Unit
Hisense Hi-Flexi & Hi-Smart series provide a wide selection of indoor units for indoor decoration and create a
personalized living space.
Product line-up
HP 0.8 1.0 1.3 1.5 1.8 2.0 2.3 2.5 3.0 3.3 4.0 5.0 6.0 8 10
kBtu/h 7 9 12 14 17 18 22 24 27 30 38 48 54 76 96
Ceiling Ducted
(Low Static Pressure)
Ceiling Ducted
(High Static Pressure)
Low-Height
Ceiling Ducted
4-Way Cassette
Compact 4-Way
Cassette
Wall Mounted
Floor Concealed
NOTES:
Hi-smart E has 3 types of indoor units for selection:
1.Low-height ceiling ducted type
2.Slim ceiling ducted type
3.Wall mounted type
111
Indoor Unit
Product line-up
according to the actual situation of building. There are 9 types of indoor
units for selection. Planner can choose appropriate type and capacity of
indoor units according to interior decoration and functions.
Ceiling Supply Ceiling Return Side Supply Ceiling Return Side Supply Side Return Side Supply Bottom Return
112
Indoor Unit
Less than 270mm in height can Minimum 5mm By introducing fresh outdoor air and being equipped with air
be easily fit into the limited 270mm
filter to keep indoor air clean.
space in the false ceiling
(7.5-24.2KBtu/h). 7.5-24.2KBtu/h False Ceiling
Excellent Air Flow Duct
ment.
Range Of Installation
Duct
Air Filter,Air Grid
Optional Parts
Canvas Duct(Field-supplied)
Air Inlet (Field-supplied)
Drain-up mechanism can be supplied as optional part.
NOTE:
When bottom air inlet is adopted, sound pressure will increase according to factors Maximum 900mm
Condensate Drain-up
NOTES:
1.The nominal cooling capacity and heating capacity are based on following 2. The sound pressure level is based on following conditions: 1.5m beneath the unit.
conditions: With discharge duct (2.0m) and return duct(1.0m)
Cooling Operation Conditions The above data was measured in an anechoic chamber so that reflected sound
Indoor Air Inlet Temperature: 27℃ DB(80°F DB), 19.0℃WB(66.2°F WB) should be taken into consideration in the field.
Outdoor Air Inlet Temperature: 35℃ DB(95°F DB) When bottom air inlet is adopted, sound pressure will increase according to factors
3.
Piping Length: 7.5 Meters Piping Lift: 0 Meter such as installation mode and the room structure.
Heating Operation Conditions *1: AC3Φ, 380V/50Hz, *2: AC3Φ, 380V/60Hz
Indoor Air Inlet Temperature: 20℃ DB(68°F DB)
Outdoor Air Inlet Temperature: 7℃DB(45°F DB), 6℃WB(43°F WB)
113
Indoor Unit
Product line-up
Less than 270mm in height can Minimum 5mm By introducing fresh outdoor air and being equipped with air
be easily fit into the limited 270mm
filter to keep indoor air clean.
space in the false ceiling
(7.5-24.2KBtu/h). 7.5-24.2KBtu/h False Ceiling
Excellent Air Flow Duct
ment.
Range of Installation
Duct
Air Filter,Air Grid
Optional Parts
Canvas Duct(Field-supplied)
Air Inlet (Field-supplied)
Drain-up mechanism can be supplied as optional part.
NOTE:
When bottom air inlet is adopted, sound pressure will increase according to factors Maximum 900mm
Condensate Drain-up
NOTES:
1.The nominal cooling capacity and heating capacity are based on following 2. The sound pressure level is based on following conditions: 1.5m beneath the unit.
conditions: With discharge duct (2.0m) and return duct(1.0m)
Cooling Operation Conditions The above data was measured in an anechoic chamber so that reflected sound
Indoor Air Inlet Temperature: 27℃ DB(80°F DB), 19.0℃WB(66.2°F WB) should be taken into consideration in the field.
Outdoor Air Inlet Temperature: 35℃ DB(95°F DB) 3. When bottom air inlet is adopted, sound pressure will increase according to factors
Piping Length: 7.5 Meters Piping Lift: 0 Meter such as installation mode and the room structure.
Heating Operation Conditions *1: AC3Φ, 380V/50Hz,
Indoor Air Inlet Temperature: 20℃ DB(68°F DB) *2: AC3Φ, 380V/60Hz: AVD- 76UX7SEH; AVD-96UX7SFH
Outdoor Air Inlet Temperature: 7℃DB(45°F DB), 6℃WB(43°F WB)
114
Indoor Unit
l - φ6
b (Around the Flange) Air Inlet
40 a
e c x 300 = d
300 4 - 40 x 12
20
x
g
33.5
22
m
n
Wired controller
22
Viewed from A
30
120
20
300 l - φ6
e (Around the Flange) Drain Pipe Connection Drain Pipe Connection
c x 300 = d
(Standard Position) (VP25) (Optional Drain-Up Mechanism)
2xv=w
(With ijh Flare Nut) u 45
a 75(Electrical Control Box)
2x90=180
220
A
90
v
r
q
p
97
23
35
s
t
Dimension
Model a b c d e f g h i j k l
07~14 650 730 1 300 215 553 583 6.35 12.7 70 92 10
17/18 900 980 2 600 190 803 833 6.35 15.88 77 92 12
22/24 900 980 2 600 190 803 833 9.53 15.88 77 95 12
27/30 900 980 2 600 190 803 833 9.53 15.88 78 95 12
38 900 980 2 600 190 803 833 9.53 15.88 81 95 12
48/54 1300 1380 3 900 240 1203 1233 9.53 15.88 81 95 14
Dimension
Model m n p q r s t u v w x
07~24 676 720 23 270 182 222 43 220 100 200 226
27~54 756 800 103 350 204 244 123 300 140 280 306
115
Indoor Unit
Product line-up
Models: AVD-76/96* Model Unit:mm
Viewed from A
(for Suspension Bolt)
916
Air Outlet
116
Indoor Unit
Low-height
Ceiling Ducted Type (Height 192mm)
Minimum 5mm
may be easily installed from the unit to indoor space through
inside narrow residential 192mm ducts, which creates a comfortable
ceiling. environment.
False Ceiling
Duct Duct
Drain-up Mechanism as Standard part
Drain-up length achieves
Elastic Hose Drain-up Length 900mm
900mm which enables
convenient drain piping and
When the required duct is short, When the required duct is long,
the static pressure can be set lower. the static pressure can be set higher; enlarges the flexibility of
installation.
NOTES:
1.The nominal cooling capacity and heating capacity are based on following conditions: 2. The sound pressure level is based on following conditions: 1.5m beneath the unit. With discharge duct
Cooling Operation Conditions (2.0m) and return duct(1.0m)
Indoor Air Inlet Temperature: 27℃ DB(80°F DB), 19.0℃WB(66.2°F WB) The above data was measured in an anechoic chamber so that reflected sound should be taken into
Outdoor Air Inlet Temperature: 35℃ DB(95°F DB) consideration in the field.
Piping Length: 7.5 Meters Piping Lift: 0 Meter When bottom air inlet is adopted, sound pressure will increase according to factors such as installation
Heating Operation Conditions mode and the room structure.
Indoor Air Inlet Temperature: 20℃ DB(68°F DB)
Outdoor Air Inlet Temperature: 7℃DB(45°F DB), 6℃WB(43°F WB)
117
Indoor Unit
54 630
759
Product line-up
Refrigerant Refrigerant Drain Pipe
Gas Pipe Liquid Pipe Connection
Electrical
Control Box φ12.7 φ 6.35 (Drain-up
477
456
421
Mechanism)
447
Air Inlet
20
9
Air Outlet
29 47
109
80
171
192
80
900
938
87
1018
1053
72 8
44 30 6
1029
477
456
421
1170
1208
1288
1323
54 940
192
Air Outlet
29 47
Dimension a b
Model
109
80
φ 15.88 φ 6.35
171
192
80
17/18
22/24 φ 15.88 φ 9.53
87
72 8
44 30 6
118
Indoor Unit
Minimum 5mm
and height of 192mm unit to indoor space through ducts, which
192mm
to the house structure and installation condition, ensure that the practical installation space. (Installation Diagram of Air Bottom Inlet)
NOTES:
1.The nominal cooling capacity and heating capacity are based on following conditions: 2. The sound pressure level is based on following conditions: 1.5m beneath the unit. With discharge duct
Cooling Operation Conditions (2.0m) and return duct(1.0m)
Indoor Air Inlet Temperature: 27℃ DB(80°F DB), 19.0℃WB(66.2°F WB) The above data was measured in an anechoic chamber so that reflected sound should be taken into
Outdoor Air Inlet Temperature: 35℃ DB(95°F DB) consideration in the field.
Piping Length: 7.5 Meters Piping Lift: 0 Meter When bottom air inlet is adopted, sound pressure will increase according to factors such as installation
Heating Operation Conditions mode and the room structure.
Indoor Air Inlet Temperature: 20℃ DB(68°F DB)
Outdoor Air Inlet Temperature: 7℃DB(45°F DB), 6℃WB(43°F WB)
119
Indoor Unit
Product line-up
Unit:mm
Liquid Pipe Gas Pipe Water Outlet Electrical Box Return Air Inlet
(Pump)
Air Outlet
120
Hi-FLEXi C Series
Air Outlet
Hi-FLEXI C series
Heat Exchanger
Heat Exchanger
DC Fan Motor
The smooth rotating fan motor with low
vibration reduces the noise level. Super High-stream Fan DC Fan Motors
97
Hi-FLEXi C Series
Features
Provide in a compact body, but allows installation conditions comparable with those of a high-performance multi-split air condition-
ing system.
The compact and light body facilitates delivery and installation.
Product line-up
The adoption of a slim body improves flexibility in mounting, enabling installation in a small space or a formerly dead space.
98
Hi-FLEXi C Series
With its light and compact body, the Hi-FLEXi C Series can be
easily carried in the elevator even in a small urban site.
Light and compact body
No cranes required for delivery facilitates renewal
99
Hi-FLEXi C Series
The piping can be designed and constructed up to a total Piping length 100m (total piping length of 250m)
Product line-up
Piping length: 100 m(Equivalent length :125m)
Max. height difference between ODU and IDU Outdoor unit is higher: 50m Indoor unit is higher : 40m
4 5
3
1
100
Hi-FLEXi C Series
101
Hi-FLEXi C Series
Product line-up
AVW-76UE(7)SR
AVW-96UE(7)SR
AVW-114UE(7)SR
AVW-76UE(7)SR
102
Hi-Smart L Series
Free Combination
One outdoor unit of Hi-Smart L series can connect maximum 7 indoor units in different types. The free combination not only
Product line-up
meets the air condition needs of large space, but also helps match the indoor decoration. Flexible choice and better system
configuration start a tour of Luxury life.
Refrigerant Pipe
Drain Pipe
103
Hi-Smart L Series
Max. height difference between the highest and the lowest indoor units is 10m.
Product line-up
Max. height difference between outdoor and indoor units is 30m.
Max. piping length is 75m.
Total piping length can be 120m.
Max. 75m
30m
10m
1104
10
04
Hi-Smart L Series
Hi-Smart L series HP 4 5 6
AC1Φ, 220 ~240V/50Hz AVW-38UCSC AVW-48UCSC AVW-54UCSC
AC1Φ, 220V/60Hz AVW-38U2SC AVW-48U2SC AVW-54U2SC
Model Power Supply
AC3Φ, 380 ~415V/50Hz --- AVW-48UESC AVW-54UESC
AC3Φ, 380V/60Hz --- AVW-48U7SC AVW-54U7SC
Kw 11.2 14.0 15.5
Nominal Capacity
KBtu/h 38.2 47.8 52.9
Cooling Operation
Power Consumption KW 2.99 3.92 4.44
EER 3.75 3.57 3.49
KW 12.5 16.0 18.0
Nominal Capacity
KBtu/h 42.7 54.6 61.4
Heating Opeartion
Power Consumption KW 2.98 4.03 4.74
COP 4.19 3.97 3.80
Air Flow Rate m³/h 5,400 5,400 6,000
Outer Dimension mm 1,380×950×370
Packing Dimension mm 1,040×460×1,500
Net Weight Kg 93 95 97
Gross Weight Kg 106 108 110
Liquid Line mm Φ9.53 Φ9.53 Φ9.53
Refrigerant Piping
Gas Line mm Φ15.88 Φ15.88 Φ15.88
Max. number of connectable IDU 6 7 7
Noise Level Cooling/Heating dB(A) 52/54 52/55 54/56
Cooling Operation ℃ DB -5~46℃DB
Operation Range
Heating Operation ℃ WB -20~15.5℃WB
Branch Pipe HFQ-052F
NOTES:
2. The sound pressure lever is based on following
1.The nominal cooling capacity and heating capacity are based on following conditions:
Cooling Operation Conditions conditions.1.5m beneath the unit.
Indoor Air Inlet Temperature: 27℃ DB(80ºF DB) Heating Operation Conditions The above date was measured in an anechoic
19.0℃ WB(66.2ºF WB) Indoor Air Inlet Temperature: 20℃ DB(68ºF DB) chamber so that reflected sound should be taken
Outdoor Air Inlet Temperature: 35℃ DB(95ºF DB) Outdoor Air Inlet Temperature: 7℃ DB(45ºF DB) into consideration in the field.
Piping Length: 7.5Meters Piping Lift: 0 Meter 6℃ WB(43ºF WB)
105
Hi-Smart L Series
NOTES:
1.Stop valve is installed in the hood.
2.The interval dimension between fixed bolts for installation is 600×410.
106
Hi-Smart E Series
1
Intelligent and
5
Intelligent Defrosting
High Efficient Technology
2 4
DC Inverter-driven
Technology 3
Low Noise and
3D Temperature
Control Technology
Drain Pipe
107
Hi-Smart E Series
Product line-up
192mm
NOTES: 2.0m
Hi-Smart E Series has 3 types of indoor units for selection:
Low-height ceiling ducted type
Slim ceiling ducted type
Wall mounted type
108
Hi-Smart E Series
Hi-Smart E series HP 3 4 5
AC1Φ, 220 ~240V/50Hz AVW-28UCSB AVW-34UCSB AVW-43UCSB
NOTES:
1.The nominal cooling and heating capacities show the capacities when the outdoor with the 100% rating of indoor unit.
Cooling Operation Conditions
Indoor Air Inlet Temperature:27℃DB/19℃WB
Outdoor Air Inlet Temperature:35℃DB
Piping Length:7.5Meters Piping Lift:0 Meter
2.The sound pressure level is based on following conditions:
1.5 Meters from floor Level,and 1Meter from the unit service cover surface.
The above data was measured in an anechoic chamber so that reflected sounde shoudle be taken into consideration in the field.
109
Hi-Smart E Series
AVW-28~43UC(2)SB Unit: mm
Product line-up
Piping and Wiring Hole
Ground
Air Outlet
Note:
1. The unit is equipped with stop valve; field refrigerant pipes are connected to stop valve through flare opening.
2. Illustrated 110 dimension marked with ** is to avoid possible conflict with the foundation, etc. in piping from the bottom.
3. Dimension marked with * is the location dimension of anchor holes.
Service Space
110
Indoor Unit
Hisense Hi-Flexi & Hi-Smart series provide a wide selection of indoor units for indoor decoration and create a
personalized living space.
Product line-up
HP 0.8 1.0 1.3 1.5 1.8 2.0 2.3 2.5 3.0 3.3 4.0 5.0 6.0 8 10
kBtu/h 7 9 12 14 17 18 22 24 27 30 38 48 54 76 96
Ceiling Ducted
(Low Static Pressure)
Ceiling Ducted
(High Static Pressure)
Low-Height
Ceiling Ducted
4-Way Cassette
Compact 4-Way
Cassette
Wall Mounted
Floor Concealed
NOTES:
Hi-smart E has 3 types of indoor units for selection:
1.Low-height ceiling ducted type
2.Slim ceiling ducted type
3.Wall mounted type
111
Indoor Unit
Product line-up
according to the actual situation of building. There are 9 types of indoor
units for selection. Planner can choose appropriate type and capacity of
indoor units according to interior decoration and functions.
Ceiling Supply Ceiling Return Side Supply Ceiling Return Side Supply Side Return Side Supply Bottom Return
112
Indoor Unit
Less than 270mm in height can Minimum 5mm By introducing fresh outdoor air and being equipped with air
be easily fit into the limited 270mm
filter to keep indoor air clean.
space in the false ceiling
(7.5-24.2KBtu/h). 7.5-24.2KBtu/h False Ceiling
Excellent Air Flow Duct
ment.
Range Of Installation
Duct
Air Filter,Air Grid
Optional Parts
Canvas Duct(Field-supplied)
Air Inlet (Field-supplied)
Drain-up mechanism can be supplied as optional part.
NOTE:
When bottom air inlet is adopted, sound pressure will increase according to factors Maximum 900mm
Condensate Drain-up
NOTES:
1.The nominal cooling capacity and heating capacity are based on following 2. The sound pressure level is based on following conditions: 1.5m beneath the unit.
conditions: With discharge duct (2.0m) and return duct(1.0m)
Cooling Operation Conditions The above data was measured in an anechoic chamber so that reflected sound
Indoor Air Inlet Temperature: 27℃ DB(80°F DB), 19.0℃WB(66.2°F WB) should be taken into consideration in the field.
Outdoor Air Inlet Temperature: 35℃ DB(95°F DB) When bottom air inlet is adopted, sound pressure will increase according to factors
3.
Piping Length: 7.5 Meters Piping Lift: 0 Meter such as installation mode and the room structure.
Heating Operation Conditions *1: AC3Φ, 380V/50Hz, *2: AC3Φ, 380V/60Hz
Indoor Air Inlet Temperature: 20℃ DB(68°F DB)
Outdoor Air Inlet Temperature: 7℃DB(45°F DB), 6℃WB(43°F WB)
113
Indoor Unit
Product line-up
Less than 270mm in height can Minimum 5mm By introducing fresh outdoor air and being equipped with air
be easily fit into the limited 270mm
filter to keep indoor air clean.
space in the false ceiling
(7.5-24.2KBtu/h). 7.5-24.2KBtu/h False Ceiling
Excellent Air Flow Duct
ment.
Range of Installation
Duct
Air Filter,Air Grid
Optional Parts
Canvas Duct(Field-supplied)
Air Inlet (Field-supplied)
Drain-up mechanism can be supplied as optional part.
NOTE:
When bottom air inlet is adopted, sound pressure will increase according to factors Maximum 900mm
Condensate Drain-up
NOTES:
1.The nominal cooling capacity and heating capacity are based on following 2. The sound pressure level is based on following conditions: 1.5m beneath the unit.
conditions: With discharge duct (2.0m) and return duct(1.0m)
Cooling Operation Conditions The above data was measured in an anechoic chamber so that reflected sound
Indoor Air Inlet Temperature: 27℃ DB(80°F DB), 19.0℃WB(66.2°F WB) should be taken into consideration in the field.
Outdoor Air Inlet Temperature: 35℃ DB(95°F DB) 3. When bottom air inlet is adopted, sound pressure will increase according to factors
Piping Length: 7.5 Meters Piping Lift: 0 Meter such as installation mode and the room structure.
Heating Operation Conditions *1: AC3Φ, 380V/50Hz,
Indoor Air Inlet Temperature: 20℃ DB(68°F DB) *2: AC3Φ, 380V/60Hz: AVD- 76UX7SEH; AVD-96UX7SFH
Outdoor Air Inlet Temperature: 7℃DB(45°F DB), 6℃WB(43°F WB)
114
Indoor Unit
l - φ6
b (Around the Flange) Air Inlet
40 a
e c x 300 = d
300 4 - 40 x 12
20
x
g
33.5
22
m
n
Wired controller
22
Viewed from A
30
120
20
300 l - φ6
e (Around the Flange) Drain Pipe Connection Drain Pipe Connection
c x 300 = d
(Standard Position) (VP25) (Optional Drain-Up Mechanism)
2xv=w
(With ijh Flare Nut) u 45
a 75(Electrical Control Box)
2x90=180
220
A
90
v
r
q
p
97
23
35
s
t
Dimension
Model a b c d e f g h i j k l
07~14 650 730 1 300 215 553 583 6.35 12.7 70 92 10
17/18 900 980 2 600 190 803 833 6.35 15.88 77 92 12
22/24 900 980 2 600 190 803 833 9.53 15.88 77 95 12
27/30 900 980 2 600 190 803 833 9.53 15.88 78 95 12
38 900 980 2 600 190 803 833 9.53 15.88 81 95 12
48/54 1300 1380 3 900 240 1203 1233 9.53 15.88 81 95 14
Dimension
Model m n p q r s t u v w x
07~24 676 720 23 270 182 222 43 220 100 200 226
27~54 756 800 103 350 204 244 123 300 140 280 306
115
Indoor Unit
Product line-up
Models: AVD-76/96* Model Unit:mm
Viewed from A
(for Suspension Bolt)
916
Air Outlet
116
Indoor Unit
Low-height
Ceiling Ducted Type (Height 192mm)
Minimum 5mm
may be easily installed from the unit to indoor space through
inside narrow residential 192mm ducts, which creates a comfortable
ceiling. environment.
False Ceiling
Duct Duct
Drain-up Mechanism as Standard part
Drain-up length achieves
Elastic Hose Drain-up Length 900mm
900mm which enables
convenient drain piping and
When the required duct is short, When the required duct is long,
the static pressure can be set lower. the static pressure can be set higher; enlarges the flexibility of
installation.
NOTES:
1.The nominal cooling capacity and heating capacity are based on following conditions: 2. The sound pressure level is based on following conditions: 1.5m beneath the unit. With discharge duct
Cooling Operation Conditions (2.0m) and return duct(1.0m)
Indoor Air Inlet Temperature: 27℃ DB(80°F DB), 19.0℃WB(66.2°F WB) The above data was measured in an anechoic chamber so that reflected sound should be taken into
Outdoor Air Inlet Temperature: 35℃ DB(95°F DB) consideration in the field.
Piping Length: 7.5 Meters Piping Lift: 0 Meter When bottom air inlet is adopted, sound pressure will increase according to factors such as installation
Heating Operation Conditions mode and the room structure.
Indoor Air Inlet Temperature: 20℃ DB(68°F DB)
Outdoor Air Inlet Temperature: 7℃DB(45°F DB), 6℃WB(43°F WB)
117
Indoor Unit
54 630
759
Product line-up
Refrigerant Refrigerant Drain Pipe
Gas Pipe Liquid Pipe Connection
Electrical
Control Box φ12.7 φ 6.35 (Drain-up
477
456
421
Mechanism)
447
Air Inlet
20
9
Air Outlet
29 47
109
80
171
192
80
900
938
87
1018
1053
72 8
44 30 6
1029
477
456
421
1170
1208
1288
1323
54 940
192
Air Outlet
29 47
Dimension a b
Model
109
80
φ 15.88 φ 6.35
171
192
80
17/18
22/24 φ 15.88 φ 9.53
87
72 8
44 30 6
118
Indoor Unit
Minimum 5mm
and height of 192mm unit to indoor space through ducts, which
192mm
to the house structure and installation condition, ensure that the practical installation space. (Installation Diagram of Air Bottom Inlet)
NOTES:
1.The nominal cooling capacity and heating capacity are based on following conditions: 2. The sound pressure level is based on following conditions: 1.5m beneath the unit. With discharge duct
Cooling Operation Conditions (2.0m) and return duct(1.0m)
Indoor Air Inlet Temperature: 27℃ DB(80°F DB), 19.0℃WB(66.2°F WB) The above data was measured in an anechoic chamber so that reflected sound should be taken into
Outdoor Air Inlet Temperature: 35℃ DB(95°F DB) consideration in the field.
Piping Length: 7.5 Meters Piping Lift: 0 Meter When bottom air inlet is adopted, sound pressure will increase according to factors such as installation
Heating Operation Conditions mode and the room structure.
Indoor Air Inlet Temperature: 20℃ DB(68°F DB)
Outdoor Air Inlet Temperature: 7℃DB(45°F DB), 6℃WB(43°F WB)
119
Indoor Unit
Product line-up
Unit:mm
Liquid Pipe Gas Pipe Water Outlet Electrical Box Return Air Inlet
(Pump)
Air Outlet
120
Hisense International Co., Ltd.
Add:17, Donghai Xi Road, Qingdao,China.
Tel:+86-532-83878888 Fax:+86-532-83866770 http://www.hisense.com E-mail: exportvrf@hisense.com
HCAC-CA2015G02
NOTICE:
When installing or relocating the air conditioners, use the specific refrigerant (R410A) only to charge the refrigerant lines. Any other refrigerant or air is not allowed to enter the lines.
If the refrigerant is mixed with air, then it may cause abnormal high pressure in the refrigerant lines, resulting in explosion or other hazards.
The use of any refrigerant other than the specific refrigerant for the system will cause mechanical failure, system malfunction or unit breakdown.
In worse case, this could lead to a serious impediment to securing the product safety.
Hisense's liability shall not cover the malfunctions or accidents resulting from the use of the wrong type of refrigerant.