You are on page 1of 2

No guarantee can be given in respect of this translation August 2008

Stud anchor SN 854


In all cases the latest German-language version
of this standard shall be taken as authoritative

ICS 21.060 Dimensions in mm Supersedes


SN 854: 2006-12

1 Field of application
Stud anchors (HST) are permitted for use in concrete for all load directions both in the pressure zone and the tension zone.
These anchors are mainly used for the fastening of supports, brackets, pump base frames, tanks etc. on concrete.

2 Dimensions and designation

Designation of a stud anchor (HST) according to SN 854 of 10 mm diameter


with thread (d) M10 and fastening height (t) of 50 mm:

Stud anchor SN 854 - HST M10/50

Table 1 Dimensions and designations


Weight
Drill hole Ordering designation
d ta l lG kg/unit
Dia. Depth Steel Stainless steel
M 8 10 75 25 8 65 HST M 8x 75/ 10 HST-R M 8x 75/ 10 0,031
M 8 30 95 25 8 65 HST M 8x 95/ 30 HST-R M 8x 95/ 30 0,038
M 8 50 115 25 8 65 HST M 8x115/ 50 HST-R M 8x115/ 50 0,044
M10 10 90 30 10 80 HST M10x 90/ 10 HST-R M10x 90/ 10 0,061
M10 30 110 30 10 80 HST M10x110/ 30 HST-R M10x110/ 30 0,068
M10 50 130 30 10 80 HST M10x130/ 50 HST-R M10x130/ 50 0,080
M12 20 115 35 12 95 HST M12x115/ 20 HST-R M12x115/ 20 0,106
M12 50 145 35 12 95 HST M12x145/ 50 HST-R M12x145/ 50 0,138
M12 90 185 35 12 95 HST M12x185/ 90 HST-R M12x185/ 90 0,156
M12 120 215 35 12 95 HST M12x215/120 HST-R M12x215/120 0,191
M12 140 235 35 12 95 HST M12x235/140 - 0,210
M12 160 255 35 12 95 HST M12x255/ 160 - 0,230
M16 25 140 40 16 115 HST M16x140/ 25 HST-R M16x140/ 25 0,230
M16 50 165 40 16 115 HST M16x165/ 50 HST-R M16x165/ 50 0,270
M16 100 215 40 16 115 HST M16x215/100 HST-R M16x215/100 0,331
M16 140 255 40 16 115 HST M16x255/140 HST-R M16x255/140 0,412
M16 180 295 40 16 115 HST M16x295/180 HST-R M16x295/180 0,470
M20 30 170 45 20 140 HST M20x170/ 30 HST-R M20x170/ 30 0,440
M20 60 200 45 20 140 HST M20x200/ 60 HST-R M20x200/ 60 0,499
M20 130 270 60 20 140 HST M20x270/130 - 0,670
M24 30 200 55 24 170 HST M24x200/ 30 HST-R M24x200/ 30 0,768
M24 60 230 55 24 170 HST M24x230/ 60 HST-R M24x230/ 60 0,868
a
t = max. fastening height

Total number of pages: 2


Herausgeber: © SMS Demag AG 2008
The reproduction, distribution and utilization of this document as well as the communication of its contents to
others without express authorization is prohibited. Offenders will be held liable for the payment of damages.
Normenstelle All rights reserved in the event of the grant of a patent, utility model or design. 14.03
Page 2
SN 854: 2008-08

3 Technical data of stud anchors HST, HST-R


Table 2 Technical data
Extract from the application conditions of HST ETA-98/0001 and HST-R ETA-98/0002 according to (ETAG Annex C). Please
take the characteristic load values from the approval document.
Approval number HST ETA-98/0001 HST-R ETA-98/0002
of 25 July 2006 of 29 March 2006
HST / HST-R M8 M10 M12 M16 M20 M24 M8 M10 M12 M16 M20 M24
Anchor base Cracked concrete ≥ C20/25 (B25)
ab
permissible tension load "perm. N“ per
[kN] 2,0 4,3 5,7 9,5 14,3 19,0 2,4 4,3 5,7 11,9 14,3 19,0
dowel
a
permissible transverse load "perm. V“
[kN] 8,0 13,4 20,0 31,4 43,5 44,8 7,4 11,4 17,1 25,5 34,8 47,9
per dowel
c
spacing scr [cm] 14,1 18,0 21,0 24,6 30,3 37,5 14,1 18,0 21,0 24,6 30,3 37,5
c
edge distance ccr [cm] 7,1 9,0 10,5 12,3 15,2 18,8 7,1 9,0 10,5 12,3 15,2 18,8
d
minimum edge distance cmin [cm] 4,5 5,5 5,0 7,0 10,0 12,5 4,5 5,0 5,5 6,0 10,0 12,5
necessary spacing s ≥ [cm] 5,0 9,0 12,0 15,0 22,5 24,0 5,0 9,0 11,0 16,0 16,0 14,0
d
minimum spacing smin [cm] 4,0 5,5 6,0 7,0 10,0 12,5 4,0 5,5 6,0 7,0 10,0 12,5
necessary edge distance c ≥ [cm] 5,0 7,0 7,5 10,0 16,0 18,0 5,0 6,5 7,5 10,0 13,0 13,0
Min. thickness of concrete member hmin [cm] 10 12 14 16 20 25 10 12 14 16 20 25
Torque used in anchoring [Nm] 20 45 60 110 240 300 20 40 60 110 240 300
a
Loads apply in case of single fastening without dense reinforcement at long edge distance, partial safety factor y1 = 1,0 for concrete failure (ETAG 001,
Progress File).
b
Increasing factors for concrete: C30/37 = 1,22, B35 = 1,18 ; C40/50 = 1,41, B45 = 1,34 ; C50/60 = 1,55, B55 = 1,48
c
When spacing s ≥ scr and edge distance c ≥ ccr , the perm. N (group) = perm. N x number of dowels of the group
d
When smin ≤ s ≤ scr and/or cmin ≤ c ≤ ccr , the permissible load shall be reduced in accordance with design method A (ETAG Annex C).

4 Material
Steel, electrogalvanised (standard);
stainless steel A4 (1.4401)

Supplier: Hilti Deutschland GmbH


Hiltistraße 2
86916 Kaufering / Germany

Referenced technical standards, codes and regulations


European Technical Approval ETA-98/0001

Exclusion from use in SAP


This standard shall not be applied when drawings and bills of materials are prepared in SAP. In SAP, the above-mentioned
parts are available as catalogue-part master data and are additionally made available in PartSolutions.

Revision of August 2008


Adaptation of technical data.
Editorial revision.