Upgradation of Basic Electrical Laboratory.

S.No. Particulars of the Equipment Quantity Price per item Tentative Cost GeM
(In Rs) (in Lakhs) Yes/No

1. Regulated Dc Supply.

Maximum Power (Watt) 120 watts


DC Current Output Rating (Ampere) 0 to 4
DC Voltage Output Rating (Volt) 0 to 30
Load Regulation (Voltage) ± (% of output + offset)
less than 0.01 +2 (milli volt)
Load Regulation (Current) ± (% of output + offset)
less than 0.05 + 1.5 mA
Line Regulation (Voltage) ± (% of output + offset)
less than 0.01 + 1 mV
Line Regulation (Current) ± (% of output + offset) 6 55,000. Yes
less than 0.05 + 0.1 mA
Over Voltage Protection Accuracy +- 0.5 + 0.5 V
Over Voltage Protection Response Time (milli sec)
less than 10 milli second
Ripple and Noise Voltage (20 Hz to 20 MHz)
less than 1 mVrms less than 4 mVpp
Ripple and Noise Current (20 Hz to 20 MHz)
less than 4 milli amps rms
Readback Voltage Accuracy 0.05 + 10 mV
Readback Current Accuracy 0.15 + 5 mA
Read back Voltage Resolution (mV) 1
Readback Current Resolution (mA) 0.1

2. Digital Multimeters – Handheld Battery


Operated
DC Voltage Range 600 Volt
DC Voltage Accuracy 0.5 percent
DC Voltage resolution 1 milliVolt
AC Voltage Range 600 Volt
AC Voltage Accuracy 1 percent
AC Voltage resolution 1 milliVolt
DC Current Range 10 Ampère
DC Current Accuracy 1.5 percent 10 3500. Yes
DC Current resolution 1 milliAmpère
AC Current Range 10 Ampère
AC Current Accuracy 1.5 percent
AC Current resolution 1 milliAmpère
Resistance Range 40 megaOhm
Resistance Accuracy 1.5 percent
Resistance resolution 0.1 Ohm
Capacitance Range ( Micro farad ) .01 to 1000
Capacitance Accuracy ( % ) 5
Capacitance resolution ( nF ) 0.01
Frequency Range ( KHz ) 100
Frequency Accuracy ( % ) 0.1
Frequency resolution ( Hz ) 0.01
Temperature Range ( Degree C ) NA
Temperature Accuracy ( % ) NA
Temperature resolution ( Degree C ) NA
3. Electrodynamometer Wattmeter
1. a) 1 phase: Current range 2.5/5A (Low Pf) 05 3000.
150/300/600V
b) 1Phase: Current range 5/10 A (High pf) No
150/30/600V. 05 3000.
2. 3 phase: Current Range
5A/10A, 10A/20A, Voltage 05 4000.
Range 250/500V, 300/600V.

4. Rheostats
1. 0 to 10 ohms,10A 10
2. 0 to 25 ohms, 5A 10 1000. No
3. 0 to 45 ohms, 2A 10
4. 0 to 100 ohms,5A 10

5. 1 phase Inductive load 230V,30A. 05 35,000. No

6. 1 phase resistive loads 230V, 30A. 05 25,000. No

7. 1 phase capacitive loads 230V, 30A 05 30,000. No

8. RLC Load bank 02 50,000. No

9. Analog Ammeter (0 to 2 A) 10 1500. No

10. Alligator connectors. 30 500. No

TOTAL