Everflow SELECTION

Submersible Deep Well


Line Shaft Turbine Pumps CHART

A division of Flow Control Pacific Pty Ltd A.B.N. 83 000 922 690
CHANGE EFFIC. NO. OF NO. OF PUMP MODEL 125LBH CURVE NO.
AS FOLLOWS POINTS STAGES
P05141
LOWER
LOWER
6
3
1
2
2910 R.P.M. DATE
VERTICAL
LOWER 1.5 4 BOWL DIA. 130 mm May-2001
TURBINE
LOWER 1 6 STANDARD CURVE ILLUSTRATES
PUMPS SINGLE STAGE PERFORMANCE ONLY K 2.1
LOWER 2 PTS FOR PLAIN BOWL

EFFICIENCIES SHOWN ARE PUMP EFFICIENCIES - COLUMN & DRIVEHEAD LOSSES ARE NOT INCLUDED
20

18

16

14 A 60% 70% 74%

B
12
74%
C
10 70%
80.4%
77%
79%
TOTAL
8 60%
HEAD
6
(metres)
4

2 1.5
INPUT
0 1
POWER
A
.5
(kW)
C
0 2 4 6 8 10 12 14 16
VOLUMETRIC FLOWRATE (litres/second)

DATA FOR CLEAN COLD WATER ONLY PUMP PERFORMANCE TO AS2417 Pt 2 Class C
IMPELLER BOWL
IMPELLER TRIM A = 103 mm PUMP LENGTH = 380 mm
IMPELLER TRIM B = 97.5 mm ADDITIONAL STAGES = 110 mm
IMPELLER TRIM C = 92 mm MAX. NO. OF STAGES = 25
EFFECTIVE EYE AREA = 30 cm² MAX. PRESS. HEAD = 340 m
NUMBER OF VANES = 8 LATERAL STD = 7.1 mm MAX 14 mm
WR² PER IMPELLER = .0012 kg.m² SUCTION SIZE = 100 mm
MAX. SPHERE SIZE = 3 mm DISCHARGE SIZE = 75/100 mm
WEIGHT = .9 kg DISCHARGE CASE DIA. = 135/135 mm
8618 Warrego Highway
WITHCOTT QLD 4352
A division of Flow Control Pacific Pty Ltd A.B.N. 83 000 922 690
CHANGE EFFIC. NO. OF NO. OF PUMP MODEL 125HXB CURVE NO.
AS FOLLOWS POINTS STAGES
P05211
LOWER
LOWER
5
3
1
2
2910 R.P.M. DATE
VERTICAL
LOWER 2 3 BOWL DIA. 134 mm May-2001
TURBINE
LOWER 1 5 STANDARD CURVE ILLUSTRATES
PUMPS SINGLE STAGE PERFORMANCE ONLY K 3
LOWER 2 PTS FOR PLAIN BOWL

EFFICIENCIES SHOWN ARE PUMP EFFICIENCIES - COLUMN & DRIVEHEAD LOSSES ARE NOT INCLUDED
14

12 A
B
C
60%
10 65%
70%
72%
8 73.5%
73.5%
TOTAL 74.6% 72%
70%
6
65%
HEAD 60%
4

(metres)
2

0 1.5

INPUT
1
A
POWER
C .5

(kW)

0 2 4 6 8 10 12 14 16 18 20 22 24
VOLUMETRIC FLOWRATE (litres/second)

DATA FOR CLEAN COLD WATER ONLY PUMP PERFORMANCE TO AS2417 Pt 2 Class C
IMPELLER BOWL
IMPELLER TRIM A = 103.2 mm PUMP LENGTH = 380 mm
IMPELLER TRIM B = 101.2 mm ADDITIONAL STAGES = 110 mm
IMPELLER TRIM C = 99.2 mm MAX. NO. OF STAGES = 20
EFFECTIVE EYE AREA = 30 cm² MAX. PRESS. HEAD = 340 m
NUMBER OF VANES = 6 LATERAL STD = 7.5 mm MAX 14 mm
WR² PER IMPELLER = .0012 kg.m² SUCTION SIZE = 100 mm
MAX. SPHERE SIZE = 4 mm DISCHARGE SIZE = 75/100 mm
WEIGHT = 1 kg DISCHARGE CASE DIA. = 135/135 mm
8618 Warrego Highway
WITHCOTT QLD 4352
A division of Flow Control Pacific Pty Ltd A.B.N. 83 000 922 690
CHANGE EFFIC. NO. OF NO. OF PUMP MODEL 150RXL CURVE NO.
AS FOLLOWS POINTS STAGES
E06211
LOWER
LOWER
5
2
1
2
2910 R.P.M. DATE
VERTICAL
RAISE 1 7 BOWL DIA. 139.7 mm May-2001
TURBINE
RAISE 1.5 12 STANDARD CURVE ILLUSTRATES
PUMPS SINGLE STAGE PERFORMANCE ONLY K 4.67
LOWER 2 PTS FOR PLAIN BOWL

EFFICIENCIES SHOWN ARE PUMP EFFICIENCIES - COLUMN & DRIVEHEAD LOSSES ARE NOT INCLUDED
16 8

A NPSHR
14 4
B
(metres)
12 60% 0
C
70%
73%
10 75%
77%
TOTAL 78%
8
78%
HEAD 79.1% 77%
6 75%
73%
(metres)
4

2 1.2
A
INPUT
0 C .8

POWER
.4

(kW)

0 2 4 6 8 10 12 14 16
VOLUMETRIC FLOWRATE (litres/second)

DATA FOR CLEAN COLD WATER ONLY PUMP PERFORMANCE TO AS2417 Pt 2 Class C
IMPELLER BOWL
IMPELLER TRIM A = 112.7 mm PUMP LENGTH = 435 mm
IMPELLER TRIM B = 108 mm ADDITIONAL STAGES = 130 mm
IMPELLER TRIM C = 101.6 mm MAX. NO. OF STAGES = 30
EFFECTIVE EYE AREA = 43.8 cm² MAX. PRESS. HEAD = 340 m
NUMBER OF VANES = 4 LATERAL STD = 11 mm MAX 12 mm
WR² PER IMPELLER = .002 kg.m² SUCTION SIZE = 100 mm
MAX. SPHERE SIZE = 8 mm DISCHARGE SIZE = 100/125 mm
WEIGHT = 1.5 kg DISCHARGE CASE DIA. = 140/162 mm
8618 Warrego Highway

A division of Flow Control Pacific Pty Ltd A.B.N. 83 000 922 690
WITHCOTT QLD 4352
CHANGE EFFIC. NO. OF NO. OF PUMP MODEL 150RL CURVE NO.
AS FOLLOWS POINTS STAGES
E06221
LOWER
LOWER
5
2
1
2
2920 R.P.M. DATE
VERTICAL
RAISE 1 7 BOWL DIA. 139.7 mm May-2001
TURBINE
RAISE 1.5 12 STANDARD CURVE ILLUSTRATES
PUMPS SINGLE STAGE PERFORMANCE ONLY K 4.67
LOWER 2 PTS FOR PLAIN BOWL

EFFICIENCIES SHOWN ARE PUMP EFFICIENCIES - COLUMN & DRIVEHEAD LOSSES ARE NOT INCLUDED
17.5 10

NPSHR
A
15 5
B (metres)
60%
12.5 0
70%
C
75%
78%
10
79.6%
TOTAL
7.5
75%
HEAD
70%
5
60%
(metres)
2.5

0 1.5
A
INPUT
1
C
POWER
.5

(kW)

0 2 4 6 8 10 12 14 16 18 20
VOLUMETRIC FLOWRATE (litres/second)

DATA FOR CLEAN COLD WATER ONLY PUMP PERFORMANCE TO AS2417 Pt 2 Class C
IMPELLER BOWL
IMPELLER TRIM A = 112.7 mm PUMP LENGTH = 435 mm
IMPELLER TRIM B = 108 mm ADDITIONAL STAGES = 130 mm
IMPELLER TRIM C = 101.6 mm MAX. NO. OF STAGES = 30
EFFECTIVE EYE AREA = 43.8 cm² MAX. PRESS. HEAD = 340 m
NUMBER OF VANES = 4 LATERAL STD = 10 mm MAX 12 mm
WR² PER IMPELLER = .00198 kg.m² SUCTION SIZE = 100 mm
MAX. SPHERE SIZE = 12 mm DISCHARGE SIZE = 100/125 mm
WEIGHT = 1.5 kg DISCHARGE CASE DIA. = 140/162 mm
8618 Warrego Highway

A division of Flow Control Pacific Pty Ltd A.B.N. 83 000 922 690
WITHCOTT QLD 4352
CHANGE EFFIC. NO. OF NO. OF PUMP MODEL 150RH CURVE NO.
AS FOLLOWS POINTS STAGES
E06241
LOWER
LOWER
5
2
1
2
2930 R.P.M. DATE
VERTICAL
RAISE 1 7 BOWL DIA. 139.7 mm May-2001
TURBINE
RAISE 1.5 12 STANDARD CURVE ILLUSTRATES
PUMPS SINGLE STAGE PERFORMANCE ONLY K 4.67
LOWER 2 PTS FOR PLAIN BOWL

EFFICIENCIES SHOWN ARE PUMP EFFICIENCIES - COLUMN & DRIVEHEAD LOSSES ARE NOT INCLUDED
18 8

NPSHR
16 4
A
(metres)
14 0
B 60%
70%
12 75%

TOTAL C
78%
10 78%

HEAD
81.2% 75%
8
70%
(metres)
6
60%

4 3

INPUT
2 2
A
POWER
0 1
C
(kW)

0 2.5 5 7.5 10 12.5 15 17.5 20 22.5 25


VOLUMETRIC FLOWRATE (litres/second)

DATA FOR CLEAN COLD WATER ONLY PUMP PERFORMANCE TO AS2417 Pt 2 Class C
IMPELLER BOWL
IMPELLER TRIM A = 112.7 mm PUMP LENGTH = 435 mm
IMPELLER TRIM B = 108 mm ADDITIONAL STAGES = 130 mm
IMPELLER TRIM C = 101.6 mm MAX. NO. OF STAGES = 30
EFFECTIVE EYE AREA = 43.8 cm² MAX. PRESS. HEAD = 340 m
NUMBER OF VANES = 7 LATERAL STD = 10 mm MAX 12 mm
WR² PER IMPELLER = .00198 kg.m² SUCTION SIZE = 100 mm
MAX. SPHERE SIZE = 12 mm DISCHARGE SIZE = 100/125 mm
WEIGHT = 1.6 kg DISCHARGE CASE DIA. = 140/162 mm
8618 Warrego Highway

A division of Flow Control Pacific Pty Ltd A.B.N. 83 000 922 690
WITHCOTT QLD 4352
CHANGE EFFIC. NO. OF NO. OF PUMP MODEL 150RM CURVE NO.
AS FOLLOWS POINTS STAGES
E06231
LOWER
LOWER
5
2
1
2
2920 R.P.M. DATE
VERTICAL
RAISE 1 7 BOWL DIA. 139.7 mm May-2001
TURBINE
RAISE 1.5 12 STANDARD CURVE ILLUSTRATES
PUMPS SINGLE STAGE PERFORMANCE ONLY K 4.67
LOWER 2 PTS FOR PLAIN BOWL

EFFICIENCIES SHOWN ARE PUMP EFFICIENCIES - COLUMN & DRIVEHEAD LOSSES ARE NOT INCLUDED
18 8

NPSHR
16 A 4

(metres)
14 B 0
60%
70%
12
C 75%
TOTAL 78%
10

HEAD
78%
8
80% 82.2% 75%
(metres)
70%
6

60%
4 3

INPUT
2 2
A
POWER
0 1
C
(kW)

0 2 4 6 8 10 12 14 16 18 20 22 24
VOLUMETRIC FLOWRATE (litres/second)

DATA FOR CLEAN COLD WATER ONLY PUMP PERFORMANCE TO AS2417 Pt 2 Class C
IMPELLER BOWL
IMPELLER TRIM A = 112.7 mm PUMP LENGTH = 435 mm
IMPELLER TRIM B = 108 mm ADDITIONAL STAGES = 130 mm
IMPELLER TRIM C = 101.6 mm MAX. NO. OF STAGES = 30
EFFECTIVE EYE AREA = 43.8 cm² MAX. PRESS. HEAD = 340 m
NUMBER OF VANES = 5 LATERAL STD = 10 mm MAX 12 mm
WR² PER IMPELLER = .00198 kg.m² SUCTION SIZE = 100 mm
MAX. SPHERE SIZE = 12 mm DISCHARGE SIZE = 100/125 mm
WEIGHT = 1.5 kg DISCHARGE CASE DIA. = 140/162 mm
8618 Warrego Highway

A division of Flow Control Pacific Pty Ltd A.B.N. 83 000 922 690
WITHCOTT QLD 4352
CHANGE EFFIC. NO. OF NO. OF PUMP MODEL 180RM CURVE NO.
AS FOLLOWS POINTS STAGES
E07131
LOWER
LOWER
4
2
1
2
2940 R.P.M. DATE
VERTICAL
LOWER 0 6 BOWL DIA. 174 mm Apr-2001
TURBINE
STANDARD CURVE ILLUSTRATES
PUMPS SINGLE STAGE PERFORMANCE ONLY K 7.9
LOWER 2 PTS FOR PLAIN BOWL

EFFICIENCIES SHOWN ARE PUMP EFFICIENCIES - COLUMN & DRIVEHEAD LOSSES ARE NOT INCLUDED
25 10
A
NPSHR
22.5 5
(metres)
20 60% 0
B
70%
17.5
75%
78%
15
TOTAL
78%
12.5
79.8% 75%
HEAD
10 70%
(metres)
7.5 60%

2.5 7.5
INPUT
0 A 5
POWER
B 2.5
(kW)

0 5 10 15 20 25 30 35 40
VOLUMETRIC FLOWRATE (litres/second)

DATA FOR CLEAN COLD WATER ONLY PUMP PERFORMANCE TO AS2417 Pt 2 Class C
IMPELLER BOWL
IMPELLER TRIM A = 139.7 mm PUMP LENGTH = 540 mm
IMPELLER TRIM B = 127 mm ADDITIONAL STAGES = 184 mm
MAX. NO. OF STAGES = 30
EFFECTIVE EYE AREA = 64.5 cm² MAX. PRESS. HEAD = 320 m
NUMBER OF VANES = 5 LATERAL STD = 12 mm MAX 15 mm
WR² PER IMPELLER = .00666 kg.m² SUCTION SIZE = 125 mm
MAX. SPHERE SIZE = 12 mm DISCHARGE SIZE = 125/150 mm
WEIGHT = 2.5 kg DISCHARGE CASE DIA. = 174/189 mm
8618 Warrego Highway

A division of Flow Control Pacific Pty Ltd A.B.N. 83 000 922 690
WITHCOTT QLD 4352
CHANGE EFFIC. NO. OF NO. OF PUMP MODEL 180RH CURVE NO.
AS FOLLOWS POINTS STAGES
E07141
LOWER
LOWER
4
2
1
2
2950 R.P.M. DATE
VERTICAL
LOWER 0 6 BOWL DIA. 174 mm Apr-2001
TURBINE
STANDARD CURVE ILLUSTRATES
PUMPS SINGLE STAGE PERFORMANCE ONLY K 7.9
LOWER 2 PTS FOR PLAIN BOWL

EFFICIENCIES SHOWN ARE PUMP EFFICIENCIES - COLUMN & DRIVEHEAD LOSSES ARE NOT INCLUDED
25 15

A NPSHR
22.5 10
(metres)
60%
20 5
70%
B
17.5 74%
76%

15 76%
TOTAL 74%
76.6%
12.5
70%
HEAD
10
60%
(metres)
7.5

2.5 7.5
INPUT
A
0 5
POWER
B
2.5
(kW)

0 5 10 15 20 25 30 35 40 45 50
VOLUMETRIC FLOWRATE (litres/second)

DATA FOR CLEAN COLD WATER ONLY PUMP PERFORMANCE TO AS2417 Pt 2 Class C
IMPELLER BOWL
IMPELLER TRIM A = 139.7 mm PUMP LENGTH = 540 mm
IMPELLER TRIM B = 127 mm ADDITIONAL STAGES = 184 mm
MAX. NO. OF STAGES = 30
EFFECTIVE EYE AREA = 64.5 cm² MAX. PRESS. HEAD = 320 m
NUMBER OF VANES = 7 LATERAL STD = 12 mm MAX 15 mm
WR² PER IMPELLER = .00666 kg.m² SUCTION SIZE = 125 mm
MAX. SPHERE SIZE = 12 mm DISCHARGE SIZE = 125/150 mm
WEIGHT = 2.5 kg DISCHARGE CASE DIA. = 174/189 mm
8618 Warrego Highway

A division of Flow Control Pacific Pty Ltd A.B.N. 83 000 922 690
WITHCOTT QLD 4352
CHANGE EFFIC. NO. OF NO. OF PUMP MODEL 200EDL CURVE NO.
AS FOLLOWS POINTS STAGES
E08221
LOWER
LOWER
3
1
1
2
2940 R.P.M. DATE
VERTICAL
LOWER 0 4 BOWL DIA. 190.5 mm May-2001
TURBINE
RAISE 1 8 STANDARD CURVE ILLUSTRATES
PUMPS SINGLE STAGE PERFORMANCE ONLY K 5.95
ENAMEL BOWL NOT AVAILABLE

EFFICIENCIES SHOWN ARE PUMP EFFICIENCIES - COLUMN & DRIVEHEAD LOSSES ARE NOT INCLUDED
27.5 10
NPSHR
25 5
A 60%
65% (metres)
70%
22.5 72% 0
73%
74%
20 B
74.6%

17.5 74%
73%
72%
15
70%
TOTAL
12.5
65%
HEAD
10 60%
(metres)
7.5

5 7.5
INPUT
2.5 5
POWER
0 2.5
A
(kW)
B
0 2 4 6 8 10 12 14 16 18 20 22 24
VOLUMETRIC FLOWRATE (litres/second)

DATA FOR CLEAN COLD WATER ONLY PUMP PERFORMANCE TO AS2417 Pt 2 Class C
IMPELLER BOWL
IMPELLER TRIM A = 144.5 mm PUMP LENGTH = 457 mm
IMPELLER TRIM B = 131.8 mm ADDITIONAL STAGES = 127 mm
MAX. NO. OF STAGES = 30
EFFECTIVE EYE AREA = 45.2 cm² MAX. PRESS. HEAD = 280 m
NUMBER OF VANES = 9 LATERAL STD = 13 mm MAX 16 mm
WR² PER IMPELLER = .0059 kg.m² SUCTION SIZE = 125 mm
MAX. SPHERE SIZE = 6 mm DISCHARGE SIZE = 100/125 mm
WEIGHT = 2.3 kg DISCHARGE CASE DIA. = 190/190 mm
8618 Warrego Highway

A division of Flow Control Pacific Pty Ltd A.B.N. 83 000 922 690
WITHCOTT QLD 4352
CHANGE EFFIC. NO. OF NO. OF PUMP MODEL 200EDM CURVE NO.
AS FOLLOWS POINTS STAGES
E08231
LOWER
LOWER
3
1
1
2
2940 R.P.M. DATE
VERTICAL
LOWER 0 4 BOWL DIA. 190.5 mm Apr-2001
TURBINE
RAISE 1 8 STANDARD CURVE ILLUSTRATES
PUMPS SINGLE STAGE PERFORMANCE ONLY K 5.95
ENAMEL BOWL NOT AVAILABLE

EFFICIENCIES SHOWN ARE PUMP EFFICIENCIES - COLUMN & DRIVEHEAD LOSSES ARE NOT INCLUDED
30 15
NPSHR
27.5 10
(metres)
25 A 60% 65% 5
70%
72%
22.5 74%

20 B
74%
TOTAL
17.5 75.7% 72%
HEAD 70%
15
(metres) 65%
12.5
60%

10

7.5 7.5
INPUT
5 5
POWER
2.5 A 2.5
(kW)
B
0 4 8 12 16 20 24 28 32
VOLUMETRIC FLOWRATE (litres/second)

DATA FOR CLEAN COLD WATER ONLY PUMP PERFORMANCE TO AS2417 Pt 2 Class C
IMPELLER BOWL
IMPELLER TRIM A = 144.5 mm PUMP LENGTH = 457 mm
IMPELLER TRIM B = 131.8 mm ADDITIONAL STAGES = 127 mm
MAX. NO. OF STAGES = 30
EFFECTIVE EYE AREA = 45.2 cm² MAX. PRESS. HEAD = 280 m
NUMBER OF VANES = 9 LATERAL STD = 10 mm MAX 13 mm
WR² PER IMPELLER = .0059 kg.m² SUCTION SIZE = 125 mm
MAX. SPHERE SIZE = 6 mm DISCHARGE SIZE = 100/125 mm
WEIGHT = 2.3 kg DISCHARGE CASE DIA. = 190/190 mm
8618 Warrego Highway

A division of Flow Control Pacific Pty Ltd A.B.N. 83 000 922 690
WITHCOTT QLD 4352
CHANGE EFFIC. NO. OF NO. OF PUMP MODEL 200EDH CURVE NO.
AS FOLLOWS POINTS STAGES
E08241
LOWER
LOWER
3
1
1
2
2950 R.P.M. DATE
VERTICAL
LOWER 0 4 BOWL DIA. 190.5 mm May-2001
TURBINE
RAISE 1 8 STANDARD CURVE ILLUSTRATES
PUMPS SINGLE STAGE PERFORMANCE ONLY K 5.95
ENAMEL BOWL NOT AVAILABLE

EFFICIENCIES SHOWN ARE PUMP EFFICIENCIES - COLUMN & DRIVEHEAD LOSSES ARE NOT INCLUDED
30

A 60% 65%
25 70%72%
74%
TOTAL 75.3%
B 74%
20
72%
HEAD 70%

15 65%
60%
(metres)
10

5 15

INPUT

0 10

POWER

5
A
(kW)
B
0 5 10 15 20 25 30 35 40
VOLUMETRIC FLOWRATE (litres/second)

DATA FOR CLEAN COLD WATER ONLY PUMP PERFORMANCE TO AS2417 Pt 2 Class C
IMPELLER BOWL
IMPELLER TRIM A = 144.5 mm PUMP LENGTH = 457 mm
IMPELLER TRIM B = 131.8 mm ADDITIONAL STAGES = 127 mm
MAX. NO. OF STAGES = 30
EFFECTIVE EYE AREA = 45.2 cm² MAX. PRESS. HEAD = 280 m
NUMBER OF VANES = 9 LATERAL STD = 10 mm MAX 13 mm
WR² PER IMPELLER = .0059 kg.m² SUCTION SIZE = 125 mm
MAX. SPHERE SIZE = 6 mm DISCHARGE SIZE = 100/125 mm
WEIGHT = 2.3 kg DISCHARGE CASE DIA. = 190/190 mm
8618 Warrego Highway

A division of Flow Control Pacific Pty Ltd A.B.N. 83 000 922 690
WITHCOTT QLD 4352
CHANGE EFFIC. NO. OF NO. OF PUMP MODEL 200CL CURVE NO.
AS FOLLOWS POINTS STAGES
E08321
LOWER
LOWER
2
1
1
2
2950 R.P.M. DATE
VERTICAL
RAISE 1 4 BOWL DIA. 190.5 mm Apr-2001
TURBINE
STANDARD CURVE ILLUSTRATES
PUMPS SINGLE STAGE PERFORMANCE ONLY K 11.31
LOWER 2 PTS FOR PLAIN BOWL

EFFICIENCIES SHOWN ARE PUMP EFFICIENCIES - COLUMN & DRIVEHEAD LOSSES ARE NOT INCLUDED
40 10

NPSHR
35 A 5

(metres)
30 0
60%
B
25 70%
74%
TOTAL 76%
20 76%

HEAD 74%
78.0%
15 70%

(metres)
60%
10

5 7.5
A
INPUT
0 5
B
POWER
2.5

(kW)

0 4 8 12 16 20 24 28 32 36 40 44 48
VOLUMETRIC FLOWRATE (litres/second)

DATA FOR CLEAN COLD WATER ONLY PUMP PERFORMANCE TO AS2417 Pt 2 Class C
IMPELLER BOWL
IMPELLER TRIM A = 160 mm PUMP LENGTH = 492 mm
IMPELLER TRIM B = 145 mm ADDITIONAL STAGES = 136.5 mm
MAX. NO. OF STAGES = 30
EFFECTIVE EYE AREA = 71 cm² MAX. PRESS. HEAD = 300 m
NUMBER OF VANES = 5 LATERAL STD = 11 mm MAX 15 mm
WR² PER IMPELLER = .0085 kg.m² SUCTION SIZE = 125 mm
MAX. SPHERE SIZE = 10 mm DISCHARGE SIZE = 125/150/200 mm
WEIGHT = 2.7 kg DISCHARGE CASE DIA. = 186/186/244 mm
8618 Warrego Highway

A division of Flow Control Pacific Pty Ltd A.B.N. 83 000 922 690
WITHCOTT QLD 4352
CHANGE EFFIC. NO. OF NO. OF PUMP MODEL 200CM CURVE NO.
AS FOLLOWS POINTS STAGES
E08331
LOWER
LOWER
2
1
1
2
2960 R.P.M. DATE
VERTICAL
RAISE 1 4 BOWL DIA. 190.5 mm May-2001
TURBINE
STANDARD CURVE ILLUSTRATES
PUMPS SINGLE STAGE PERFORMANCE ONLY K 11.31
LOWER 2 PTS FOR PLAIN BOWL

EFFICIENCIES SHOWN ARE PUMP EFFICIENCIES - COLUMN & DRIVEHEAD LOSSES ARE NOT INCLUDED
40 15

NPSHR
35 A 10

(metres)
30 5
60%
B 65%
70%
25 0

TOTAL
20
75% 78.7% 70%
HEAD 77%
65%
15
60%
(metres)
10

5 15

INPUT
0 10
A
POWER

B 5

(kW)

0 4 8 12 16 20 24 28 32 36 40 44 48
VOLUMETRIC FLOWRATE (litres/second)

DATA FOR CLEAN COLD WATER ONLY PUMP PERFORMANCE TO AS2417 Pt 2 Class C
IMPELLER BOWL
IMPELLER TRIM A = 160 mm PUMP LENGTH = 492 mm
IMPELLER TRIM B = 145 mm ADDITIONAL STAGES = 136.5 mm
MAX. NO. OF STAGES = 30
EFFECTIVE EYE AREA = 71 cm² MAX. PRESS. HEAD = 300 m
NUMBER OF VANES = 5 LATERAL STD = 11 mm MAX 15 mm
WR² PER IMPELLER = .0085 kg.m² SUCTION SIZE = 125 mm
MAX. SPHERE SIZE = 10 mm DISCHARGE SIZE = 125/150/200 mm
WEIGHT = 2.7 kg DISCHARGE CASE DIA. = 186/186/244 mm
8618 Warrego Highway

A division of Flow Control Pacific Pty Ltd A.B.N. 83 000 922 690
WITHCOTT QLD 4352
CHANGE EFFIC. NO. OF NO. OF PUMP MODEL 200CH CURVE NO.
AS FOLLOWS POINTS STAGES
E08341
LOWER
LOWER
2
1
1
2
2960 R.P.M. DATE
VERTICAL
RAISE 1 4 BOWL DIA. 190.5 mm Apr-2001
TURBINE
STANDARD CURVE ILLUSTRATES
PUMPS SINGLE STAGE PERFORMANCE ONLY K 11.31
LOWER 2 PTS FOR PLAIN BOWL

EFFICIENCIES SHOWN ARE PUMP EFFICIENCIES - COLUMN & DRIVEHEAD LOSSES ARE NOT INCLUDED
40 15

NPSHR
35 10
A
(metres)
30 5
60%
65%
B 70%
73%
25 75%
TOTAL 75%
20 73%
78.2% 70%
HEAD 76%

15 65%
60%
(metres)
10

5 15

INPUT
0 10
A
POWER
B 5

(kW)

0 5 10 15 20 25 30 35 40 45 50 55 60
VOLUMETRIC FLOWRATE (litres/second)

DATA FOR CLEAN COLD WATER ONLY PUMP PERFORMANCE TO AS2417 Pt 2 Class C
IMPELLER BOWL
IMPELLER TRIM A = 160 mm PUMP LENGTH = 492 mm
IMPELLER TRIM B = 145 mm ADDITIONAL STAGES = 136.5 mm
MAX. NO. OF STAGES = 30
EFFECTIVE EYE AREA = 71 cm² MAX. PRESS. HEAD = 300 m
NUMBER OF VANES = 7 LATERAL STD = 11 mm MAX 15 mm
WR² PER IMPELLER = .0085 kg.m² SUCTION SIZE = 125 mm
MAX. SPHERE SIZE = 10 mm DISCHARGE SIZE = 125/150/200 mm
WEIGHT = 2.8 kg DISCHARGE CASE DIA. = 186/186/244 mm
8618 Warrego Highway

A division of Flow Control Pacific Pty Ltd A.B.N. 83 000 922 690
WITHCOTT QLD 4352
CHANGE EFFIC. NO. OF NO. OF PUMP MODEL 200FHL CURVE NO.
AS FOLLOWS POINTS STAGES
E08421
LOWER
LOWER
3
1
1
2
2960 R.P.M. DATE
VERTICAL
LOWER 0 4 BOWL DIA. 192.5 mm May-2001
TURBINE
STANDARD CURVE ILLUSTRATES
PUMPS SINGLE STAGE PERFORMANCE ONLY K 11.83
LOWER 2 PTS FOR PLAIN BOWL

EFFICIENCIES SHOWN ARE PUMP EFFICIENCIES - COLUMN & DRIVEHEAD LOSSES ARE NOT INCLUDED
36 16

NPSHR
32 12
A
(metres)
28 B 8

24 60% 4
65%
TOTAL 70%
72%
20 74%
HEAD 74%
16 77.0% 72%
70%
(metres)
12 65%

8 12

INPUT
A
4 8
B
POWER
0 4

(kW)

0 10 20 30 40 50 60 70 80
VOLUMETRIC FLOWRATE (litres/second)

DATA FOR CLEAN COLD WATER ONLY PUMP PERFORMANCE TO AS2417 Pt 2 Class C
IMPELLER BOWL
IMPELLER TRIM A = 160.5 mm PUMP LENGTH = 584 mm
IMPELLER TRIM B = 152.4 mm ADDITIONAL STAGES = 190.5 mm
MAX. NO. OF STAGES = 30
EFFECTIVE EYE AREA = 78.7 cm² MAX. PRESS. HEAD = 300 m
NUMBER OF VANES = 5 LATERAL STD = 20 mm MAX 22 mm
WR² PER IMPELLER = .0102 kg.m² SUCTION SIZE = 150 mm
MAX. SPHERE SIZE = 12 mm DISCHARGE SIZE = 125/150/200 mm
WEIGHT = 2.6 kg DISCHARGE CASE DIA. = 186/186/244 mm
8618 Warrego Highway

A division of Flow Control Pacific Pty Ltd A.B.N. 83 000 922 690
WITHCOTT QLD 4352
CHANGE EFFIC. NO. OF NO. OF PUMP MODEL 200FHM CURVE NO.
AS FOLLOWS POINTS STAGES
E08431
LOWER
LOWER
3
1
1
2
2970 R.P.M. DATE
VERTICAL
LOWER 0 4 BOWL DIA. 192.5 mm Apr-2001
TURBINE
STANDARD CURVE ILLUSTRATES
PUMPS SINGLE STAGE PERFORMANCE ONLY K 11.83
LOWER 2 PTS FOR PLAIN BOWL

EFFICIENCIES SHOWN ARE PUMP EFFICIENCIES - COLUMN & DRIVEHEAD LOSSES ARE NOT INCLUDED
40 12
NPSHR
36 8
(metres)
32 4
A
28 0
B

24 60%
65%
20 70%
72%
TOTAL
16
74.1%
72%
HEAD 70%
12
65%
(metres) 60%
8

4 12
A
INPUT
0 B 8
POWER
4
(kW)

0 10 20 30 40 50 60 70 80
VOLUMETRIC FLOWRATE (litres/second)

DATA FOR CLEAN COLD WATER ONLY PUMP PERFORMANCE TO AS2417 Pt 2 Class C
IMPELLER BOWL
IMPELLER TRIM A = 160.5 mm PUMP LENGTH = 584 mm
IMPELLER TRIM B = 152.4 mm ADDITIONAL STAGES = 190.5 mm
MAX. NO. OF STAGES = 30
EFFECTIVE EYE AREA = 98.7 cm² MAX. PRESS. HEAD = 300 m
NUMBER OF VANES = 5 LATERAL STD = 16 mm MAX 19 mm
WR² PER IMPELLER = .0102 kg.m² SUCTION SIZE = 150 mm
MAX. SPHERE SIZE = 19 mm DISCHARGE SIZE = 125/150/200 mm
WEIGHT = 3 kg DISCHARGE CASE DIA. = 186/186/244 mm
8618 Warrego Highway

A division of Flow Control Pacific Pty Ltd A.B.N. 83 000 922 690
WITHCOTT QLD 4352
CHANGE EFFIC. NO. OF NO. OF PUMP MODEL 200FHH CURVE NO.
AS FOLLOWS POINTS STAGES
E08441
LOWER
LOWER
4
2
1
2
2970 R.P.M. DATE
VERTICAL
LOWER 0 4 BOWL DIA. 192.5 mm Apr-2001
TURBINE
STANDARD CURVE ILLUSTRATES
PUMPS SINGLE STAGE PERFORMANCE ONLY K 11.83
LOWER 2 PTS FOR PLAIN BOWL

EFFICIENCIES SHOWN ARE PUMP EFFICIENCIES - COLUMN & DRIVEHEAD LOSSES ARE NOT INCLUDED
32 16

NPSHR
A
28 12
B
(metres)
24 8
60%
65%
70%
74%
20 76% 4

TOTAL 76%
16 78.5% 74%
70%
HEAD
65%
12
60%
(metres)
8

A
4 12
B INPUT
0 8

POWER
4

(kW)

0 10 20 30 40 50 60 70 80 90 100
VOLUMETRIC FLOWRATE (litres/second)

DATA FOR CLEAN COLD WATER ONLY PUMP PERFORMANCE TO AS2417 Pt 2 Class C
IMPELLER BOWL
IMPELLER TRIM A = 160.5 mm PUMP LENGTH = 584 mm
IMPELLER TRIM B = 152.4 mm ADDITIONAL STAGES = 190.5 mm
MAX. NO. OF STAGES = 30
EFFECTIVE EYE AREA = 112.9 cm² MAX. PRESS. HEAD = 300 m
NUMBER OF VANES = 7 LATERAL STD = 15 mm MAX 18 mm
WR² PER IMPELLER = .0102 kg.m² SUCTION SIZE = 150 mm
MAX. SPHERE SIZE = 12 mm DISCHARGE SIZE = 125/150/200 mm
WEIGHT = 3 kg DISCHARGE CASE DIA. = 186/186/244 mm
8618 Warrego Highway

A division of Flow Control Pacific Pty Ltd A.B.N. 83 000 922 690
WITHCOTT QLD 4352
CHANGE EFFIC. NO. OF NO. OF PUMP MODEL 200GHM CURVE NO.
AS FOLLOWS POINTS STAGES
E08531
LOWER
LOWER
4
2
1
2
2950 R.P.M. DATE
VERTICAL
LOWER 0 4 BOWL DIA. 184.2 mm Apr-2001
TURBINE
RAISE 1 8 STANDARD CURVE ILLUSTRATES
PUMPS SINGLE STAGE PERFORMANCE ONLY K 11.9
LOWER 2 PTS FOR PLAIN BOWL

EFFICIENCIES SHOWN ARE PUMP EFFICIENCIES - COLUMN & DRIVEHEAD LOSSES ARE NOT INCLUDED
30 15

NPSHR
A
25 10

TOTAL (metres)

20 5

HEAD B 60%
65%
15 70% 0
73%
(metres) 74.8%

10 70%
65%
60%

5 15

INPUT
A
0 10

POWER
B
5

(kW)

0 10 20 30 40 50 60 70 80 90 100
VOLUMETRIC FLOWRATE (litres/second)

DATA FOR CLEAN COLD WATER ONLY PUMP PERFORMANCE TO AS2417 Pt 2 Class C
IMPELLER BOWL
IMPELLER TRIM A = 152.4 mm PUMP LENGTH = 540 mm
IMPELLER TRIM B = 139.7 mm ADDITIONAL STAGES = 171.5 mm
MAX. NO. OF STAGES = 30
EFFECTIVE EYE AREA = 104.8 cm² MAX. PRESS. HEAD = 300 m
NUMBER OF VANES = 5 LATERAL STD = 14 mm MAX 16 mm
WR² PER IMPELLER = .0068 kg.m² SUCTION SIZE = 150 mm
MAX. SPHERE SIZE = 6 mm DISCHARGE SIZE = 125/150/200 mm
WEIGHT = 2.5 kg DISCHARGE CASE DIA. = 186/186/244 mm
8618 Warrego Highway

A division of Flow Control Pacific Pty Ltd A.B.N. 83 000 922 690
WITHCOTT QLD 4352
CHANGE EFFIC. NO. OF NO. OF PUMP MODEL 200GHH CURVE NO.
AS FOLLOWS POINTS STAGES
E08541
LOWER
LOWER
4
2
1
2
2960 R.P.M. DATE
VERTICAL
LOWER 0 4 BOWL DIA. 184.2 mm Apr-2001
TURBINE
RAISE 1 8 STANDARD CURVE ILLUSTRATES
PUMPS SINGLE STAGE PERFORMANCE ONLY K 11.9
LOWER 2 PTS FOR PLAIN BOWL

EFFICIENCIES SHOWN ARE PUMP EFFICIENCIES - COLUMN & DRIVEHEAD LOSSES ARE NOT INCLUDED
30 20

NPSHR

25 15
A

TOTAL (metres)

20 10
B
HEAD
60%
65%
15 69% 5
71%
72.2%
(metres)
10 65%
60%

5 15

A INPUT

0 10

B
POWER

(kW)

0 10 20 30 40 50 60 70 80 90 100
VOLUMETRIC FLOWRATE (litres/second)

DATA FOR CLEAN COLD WATER ONLY PUMP PERFORMANCE TO AS2417 Pt 2 Class C
IMPELLER BOWL
IMPELLER TRIM A = 152.4 mm PUMP LENGTH = 540 mm
IMPELLER TRIM B = 139.7 mm ADDITIONAL STAGES = 171.5 mm
MAX. NO. OF STAGES = 30
EFFECTIVE EYE AREA = 104.8 cm² MAX. PRESS. HEAD = 300 m
NUMBER OF VANES = 5 LATERAL STD = 14 mm MAX 16 mm
WR² PER IMPELLER = .0068 kg.m² SUCTION SIZE = 150 mm
MAX. SPHERE SIZE = 6 mm DISCHARGE SIZE = 125/150/200 mm
WEIGHT = 2.5 kg DISCHARGE CASE DIA. = 186/186/244 mm
8618 Warrego Highway

A division of Flow Control Pacific Pty Ltd A.B.N. 83 000 922 690
WITHCOTT QLD 4352
CHANGE EFFIC. NO. OF NO. OF PUMP MODEL 250RL CURVE NO.
AS FOLLOWS POINTS STAGES
E10322
LOWER
RAISE
1
1
1
5
1460 R.P.M. DATE
VERTICAL
BOWL DIA. 245 mm May-2001
TURBINE
STANDARD CURVE ILLUSTRATES
PUMPS SINGLE STAGE PERFORMANCE ONLY K 12.4
LOWER 2 PTS FOR PLAIN BOWL

EFFICIENCIES SHOWN ARE PUMP EFFICIENCIES - COLUMN & DRIVEHEAD LOSSES ARE NOT INCLUDED
A
12 8

B NPSHR
60%
10 70% 4
C
75%
TOTAL (metres)
78%
8 79.2% 0

HEAD 78%

6 75%

70%
(metres)
4
60%

2 3

INPUT
A
0 2

POWER
C
1

(kW)

0 5 10 15 20 25 30 35 40
VOLUMETRIC FLOWRATE (litres/second)

DATA FOR CLEAN COLD WATER ONLY PUMP PERFORMANCE TO AS2417 Pt 2 Class C
IMPELLER BOWL
IMPELLER TRIM A = 196.8 mm PUMP LENGTH = 575 mm
IMPELLER TRIM B = 187.3 mm ADDITIONAL STAGES = 212 mm
IMPELLER TRIM C = 177.8 mm MAX. NO. OF STAGES = 20
EFFECTIVE EYE AREA = 116.8 cm² MAX. PRESS. HEAD = 280 m
NUMBER OF VANES = 6 LATERAL STD = 18 mm MAX 21 mm
WR² PER IMPELLER = .042 kg.m² SUCTION SIZE = 200 mm
MAX. SPHERE SIZE = 12 mm DISCHARGE SIZE = 150/200/250 mm
WEIGHT = 5 kg DISCHARGE CASE DIA. = 244/244/296 mm
8618 Warrego Highway

A division of Flow Control Pacific Pty Ltd A.B.N. 83 000 922 690
WITHCOTT QLD 4352
CHANGE EFFIC. NO. OF NO. OF PUMP MODEL 250RL CURVE NO.
AS FOLLOWS POINTS STAGES
E10321
LOWER
RAISE
1
1
1
5
2975 R.P.M. DATE
VERTICAL
BOWL DIA. 245 mm May-2001
TURBINE
STANDARD CURVE ILLUSTRATES
PUMPS SINGLE STAGE PERFORMANCE ONLY K 12.4
LOWER 2 PTS FOR PLAIN BOWL

EFFICIENCIES SHOWN ARE PUMP EFFICIENCIES - COLUMN & DRIVEHEAD LOSSES ARE NOT INCLUDED
55 20

A NPSHR
50 15
(metres)
B
45 10
60%
65%
70%
40 C 5
74%
77%
35
78.2%

30 77%
TOTAL
74%
25
70%
HEAD
20 65%

(metres) 60%
15

10 30
INPUT
5 A 20
POWER
0 C 10
(kW)

0 10 20 30 40 50 60 70 80 90 100
VOLUMETRIC FLOWRATE (litres/second)

DATA FOR CLEAN COLD WATER ONLY PUMP PERFORMANCE TO AS2417 Pt 2 Class C
IMPELLER BOWL
IMPELLER TRIM A = 196.8 mm PUMP LENGTH = 575 mm
IMPELLER TRIM B = 187.3 mm ADDITIONAL STAGES = 212 mm
IMPELLER TRIM C = 177.8 mm MAX. NO. OF STAGES = 20
EFFECTIVE EYE AREA = 116.8 cm² MAX. PRESS. HEAD = 280 m
NUMBER OF VANES = 6 LATERAL STD = 18 mm MAX 21 mm
WR² PER IMPELLER = .042 kg.m² SUCTION SIZE = 200 mm
MAX. SPHERE SIZE = 12 mm DISCHARGE SIZE = 150/200/250 mm
WEIGHT = 5 kg DISCHARGE CASE DIA. = 244/244/296 mm
8618 Warrego Highway

A division of Flow Control Pacific Pty Ltd A.B.N. 83 000 922 690
WITHCOTT QLD 4352
CHANGE EFFIC. NO. OF NO. OF PUMP MODEL 250RM CURVE NO.
AS FOLLOWS POINTS STAGES
E10332
LOWER
RAISE
1
1
1
5
1470 R.P.M. DATE
VERTICAL
BOWL DIA. 245 mm May-2001
TURBINE
STANDARD CURVE ILLUSTRATES
PUMPS SINGLE STAGE PERFORMANCE ONLY K 12.4
LOWER 2 PTS FOR PLAIN BOWL

EFFICIENCIES SHOWN ARE PUMP EFFICIENCIES - COLUMN & DRIVEHEAD LOSSES ARE NOT INCLUDED
16 8

NPSHR
14 4

(metres)
12 A 0
B
60%
70%
10 C 75%
78%
TOTAL 80%
81%
8
81%
HEAD 80%
81.3%
78%
6 75%
(metres) 70%

4 60%

2 3

INPUT
A
0 2

C POWER
1

(kW)

0 4 8 12 16 20 24 28 32 36 40 44 48
VOLUMETRIC FLOWRATE (litres/second)

DATA FOR CLEAN COLD WATER ONLY PUMP PERFORMANCE TO AS2417 Pt 2 Class C
IMPELLER BOWL
IMPELLER TRIM A = 196.8 mm PUMP LENGTH = 575 mm
IMPELLER TRIM B = 187.3 mm ADDITIONAL STAGES = 212 mm
IMPELLER TRIM C = 177.8 mm MAX. NO. OF STAGES = 20
EFFECTIVE EYE AREA = 116.8 cm² MAX. PRESS. HEAD = 280 m
NUMBER OF VANES = 6 LATERAL STD = 18 mm MAX 21 mm
WR² PER IMPELLER = .042 kg.m² SUCTION SIZE = 200 mm
MAX. SPHERE SIZE = 12 mm DISCHARGE SIZE = 150/200/250 mm
WEIGHT = 5 kg DISCHARGE CASE DIA. = 244/244/296 mm
8618 Warrego Highway

A division of Flow Control Pacific Pty Ltd A.B.N. 83 000 922 690
WITHCOTT QLD 4352
CHANGE EFFIC. NO. OF NO. OF PUMP MODEL 250RM CURVE NO.
AS FOLLOWS POINTS STAGES
E10331
LOWER
RAISE
1
1
1
5
2980 R.P.M. DATE
VERTICAL
BOWL DIA. 245 mm May-2001
TURBINE
STANDARD CURVE ILLUSTRATES
PUMPS SINGLE STAGE PERFORMANCE ONLY K 12.4
LOWER 2 PTS FOR PLAIN BOWL

EFFICIENCIES SHOWN ARE PUMP EFFICIENCIES - COLUMN & DRIVEHEAD LOSSES ARE NOT INCLUDED
55 20
NPSHR
50 A 15
(metres)
45 B 10
60%
C
40 70% 5
74%
77%
35
79%
79%
30
TOTAL 81.3% 77%
25 74%
HEAD 70%
20
(metres) 60%
15

10 30
INPUT
5 A 20
POWER
0 C 10
(kW)

0 10 20 30 40 50 60 70 80 90 100
VOLUMETRIC FLOWRATE (litres/second)

DATA FOR CLEAN COLD WATER ONLY PUMP PERFORMANCE TO AS2417 Pt 2 Class C
IMPELLER BOWL
IMPELLER TRIM A = 196.8 mm PUMP LENGTH = 575 mm
IMPELLER TRIM B = 187.3 mm ADDITIONAL STAGES = 212 mm
IMPELLER TRIM C = 177.8 mm MAX. NO. OF STAGES = 20
EFFECTIVE EYE AREA = 116.8 cm² MAX. PRESS. HEAD = 280 m
NUMBER OF VANES = 6 LATERAL STD = 18 mm MAX 21 mm
WR² PER IMPELLER = .042 kg.m² SUCTION SIZE = 200 mm
MAX. SPHERE SIZE = 12 mm DISCHARGE SIZE = 150/200/250 mm
WEIGHT = 5 kg DISCHARGE CASE DIA. = 244/244/296 mm
8618 Warrego Highway

A division of Flow Control Pacific Pty Ltd A.B.N. 83 000 922 690
WITHCOTT QLD 4352
CHANGE EFFIC. NO. OF NO. OF PUMP MODEL 250RH CURVE NO.
AS FOLLOWS POINTS STAGES
E10342
LOWER
RAISE
1
1
1
5
1470 R.P.M. DATE
VERTICAL
BOWL DIA. 245 mm May-2001
TURBINE
STANDARD CURVE ILLUSTRATES
PUMPS SINGLE STAGE PERFORMANCE ONLY K 12.4
LOWER 2 PTS FOR PLAIN BOWL

EFFICIENCIES SHOWN ARE PUMP EFFICIENCIES - COLUMN & DRIVEHEAD LOSSES ARE NOT INCLUDED
14 8

NPSHR
A
12 4
60%
65% (metres)
TOTAL B 70%
74%
10 77% 0
C
78.4%
HEAD
8

(metres)
70%
6
65%
60%

4 6

INPUT

2 4

A POWER

0 2
C
(kW)

0 5 10 15 20 25 30 35 40 45 50 55 60
VOLUMETRIC FLOWRATE (litres/second)

DATA FOR CLEAN COLD WATER ONLY PUMP PERFORMANCE TO AS2417 Pt 2 Class C
IMPELLER BOWL
IMPELLER TRIM A = 196.8 mm PUMP LENGTH = 575 mm
IMPELLER TRIM B = 187.3 mm ADDITIONAL STAGES = 212 mm
IMPELLER TRIM C = 177.8 mm MAX. NO. OF STAGES = 20
EFFECTIVE EYE AREA = 116.8 cm² MAX. PRESS. HEAD = 280 m
NUMBER OF VANES = 7 LATERAL STD = 18 mm MAX 21 mm
WR² PER IMPELLER = .042 kg.m² SUCTION SIZE = 200 mm
MAX. SPHERE SIZE = 12 mm DISCHARGE SIZE = 150/200/250 mm
WEIGHT = 5 kg DISCHARGE CASE DIA. = 244/244/296 mm
8618 Warrego Highway

A division of Flow Control Pacific Pty Ltd A.B.N. 83 000 922 690
WITHCOTT QLD 4352
CHANGE EFFIC. NO. OF NO. OF PUMP MODEL 250RH CURVE NO.
AS FOLLOWS POINTS STAGES
E10341
LOWER
RAISE
1
1
1
5
2980 R.P.M. DATE
VERTICAL
BOWL DIA. 245 mm May-2001
TURBINE
STANDARD CURVE ILLUSTRATES
PUMPS SINGLE STAGE PERFORMANCE ONLY K 12.4
LOWER 2 PTS FOR PLAIN BOWL

EFFICIENCIES SHOWN ARE PUMP EFFICIENCIES - COLUMN & DRIVEHEAD LOSSES ARE NOT INCLUDED
60 20
NPSHR
55 15
(metres)
50 10
A

45 5
B 60%
65%
70%
40 72%
C 74%
74.6%
35
74%
TOTAL
72%
30
70%
HEAD
25 65%

(metres) 60%
20

15 60
INPUT
10 40
POWER
A
5 20
C (kW)

0 10 20 30 40 50 60 70 80 90 100
VOLUMETRIC FLOWRATE (litres/second)

DATA FOR CLEAN COLD WATER ONLY PUMP PERFORMANCE TO AS2417 Pt 2 Class C
IMPELLER BOWL
IMPELLER TRIM A = 196.8 mm PUMP LENGTH = 575 mm
IMPELLER TRIM B = 187.3 mm ADDITIONAL STAGES = 212 mm
IMPELLER TRIM C = 177.8 mm MAX. NO. OF STAGES = 20
EFFECTIVE EYE AREA = 116.8 cm² MAX. PRESS. HEAD = 280 m
NUMBER OF VANES = 7 LATERAL STD = 18 mm MAX 21 mm
WR² PER IMPELLER = .042 kg.m² SUCTION SIZE = 200 mm
MAX. SPHERE SIZE = 12 mm DISCHARGE SIZE = 150/200/250 mm
WEIGHT = 5 kg DISCHARGE CASE DIA. = 244/244/296 mm
8618 Warrego Highway

A division of Flow Control Pacific Pty Ltd A.B.N. 83 000 922 690
WITHCOTT QLD 4352
CHANGE EFFIC. NO. OF NO. OF PUMP MODEL 250FHL CURVE NO.
AS FOLLOWS POINTS STAGES
E10422
LOWER
LOWER
2
1
1
2
1470 R.P.M. DATE
VERTICAL
LOWER 0 3 BOWL DIA. 245 mm May-2001
TURBINE
STANDARD CURVE ILLUSTRATES
PUMPS SINGLE STAGE PERFORMANCE ONLY K 20.7
LOWER 2 PTS FOR PLAIN BOWL

EFFICIENCIES SHOWN ARE PUMP EFFICIENCIES - COLUMN & DRIVEHEAD LOSSES ARE NOT INCLUDED
14 8

NPSHR
12 4
A
(metres)
10 0

8 60%
67%
TOTAL 72%
75%
77%
6 78.1%
HEAD
72%
4
67%
(metres) 60%

0 6

INPUT
A
4

POWER
B
2

(kW)

0 10 20 30 40 50 60 70 80
VOLUMETRIC FLOWRATE (litres/second)

DATA FOR CLEAN COLD WATER ONLY PUMP PERFORMANCE TO AS2417 Pt 2 Class C
IMPELLER BOWL
IMPELLER TRIM A = 203 mm PUMP LENGTH = 685 mm
IMPELLER TRIM B = 190 mm ADDITIONAL STAGES = 222 mm
MAX. NO. OF STAGES = 20
EFFECTIVE EYE AREA = 191.6 cm² MAX. PRESS. HEAD = 280 m
NUMBER OF VANES = 5 LATERAL STD = 18 mm MAX 21 mm
WR² PER IMPELLER = .0354 kg.m² SUCTION SIZE = 200 mm
MAX. SPHERE SIZE = 19 mm DISCHARGE SIZE = 150/200/250 mm
WEIGHT = 7 kg DISCHARGE CASE DIA. = 249/249/296 mm
8618 Warrego Highway

A division of Flow Control Pacific Pty Ltd A.B.N. 83 000 922 690
WITHCOTT QLD 4352
CHANGE EFFIC. NO. OF NO. OF PUMP MODEL 250FHL CURVE NO.
AS FOLLOWS POINTS STAGES
E10421
LOWER
LOWER
2
1
1
2
2975 R.P.M. DATE
VERTICAL
LOWER 0 3 BOWL DIA. 245 mm May-2001
TURBINE
STANDARD CURVE ILLUSTRATES
PUMPS SINGLE STAGE PERFORMANCE ONLY K 20.7
LOWER 2 PTS FOR PLAIN BOWL

EFFICIENCIES SHOWN ARE PUMP EFFICIENCIES - COLUMN & DRIVEHEAD LOSSES ARE NOT INCLUDED
50

45 A

40

B
35
60%
30 65%
70%
73%
25
74.8%
TOTAL
20
70%
HEAD
15 65%
60%
(metres)
10
A

5 30
INPUT
0 B 20
POWER
10
(kW)

0 20 40 60 80 100 120 140 160


VOLUMETRIC FLOWRATE (litres/second)

DATA FOR CLEAN COLD WATER ONLY PUMP PERFORMANCE TO AS2417 Pt 2 Class C
IMPELLER BOWL
IMPELLER TRIM A = 203 mm PUMP LENGTH = 685 mm
IMPELLER TRIM B = 190 mm ADDITIONAL STAGES = 222 mm
MAX. NO. OF STAGES = 20
EFFECTIVE EYE AREA = 191.6 cm² MAX. PRESS. HEAD = 280 m
NUMBER OF VANES = 5 LATERAL STD = 18 mm MAX 21 mm
WR² PER IMPELLER = .0354 kg.m² SUCTION SIZE = 200 mm
MAX. SPHERE SIZE = 19 mm DISCHARGE SIZE = 150/200/250 mm
WEIGHT = 7 kg DISCHARGE CASE DIA. = 249/249/296 mm
8618 Warrego Highway

A division of Flow Control Pacific Pty Ltd A.B.N. 83 000 922 690
WITHCOTT QLD 4352
CHANGE EFFIC. NO. OF NO. OF PUMP MODEL 250FHM CURVE NO.
AS FOLLOWS POINTS STAGES
E10432
LOWER
LOWER
2
1
1
2
1470 R.P.M. DATE
VERTICAL
LOWER 0 3 BOWL DIA. 245 mm May-2001
TURBINE
STANDARD CURVE ILLUSTRATES
PUMPS SINGLE STAGE PERFORMANCE ONLY K 20.7
LOWER 2 PTS FOR PLAIN BOWL

EFFICIENCIES SHOWN ARE PUMP EFFICIENCIES - COLUMN & DRIVEHEAD LOSSES ARE NOT INCLUDED
12 8
A
NPSHR

10 4

TOTAL B (metres)

8 60% 0
65%
HEAD 70%
75%
6 78%
78.9%
(metres)
4 70%
65%
60%

2 6
A
INPUT

0 4
B
POWER

(kW)

0 10 20 30 40 50 60 70 80 90 100
VOLUMETRIC FLOWRATE (litres/second)

DATA FOR CLEAN COLD WATER ONLY PUMP PERFORMANCE TO AS2417 Pt 2 Class C
IMPELLER BOWL
IMPELLER TRIM A = 203 mm PUMP LENGTH = 685 mm
IMPELLER TRIM B = 190 mm ADDITIONAL STAGES = 222 mm
MAX. NO. OF STAGES = 20
EFFECTIVE EYE AREA = 191.6 cm² MAX. PRESS. HEAD = 280 m
NUMBER OF VANES = 5 LATERAL STD = 13 mm MAX 16 mm
WR² PER IMPELLER = .0354 kg.m² SUCTION SIZE = 200 mm
MAX. SPHERE SIZE = 25 mm DISCHARGE SIZE = 150/200/250 mm
WEIGHT = 7 kg DISCHARGE CASE DIA. = 249/249/296 mm
8618 Warrego Highway

A division of Flow Control Pacific Pty Ltd A.B.N. 83 000 922 690
WITHCOTT QLD 4352
CHANGE EFFIC. NO. OF NO. OF PUMP MODEL 250FHM CURVE NO.
AS FOLLOWS POINTS STAGES
E10431
LOWER
LOWER
2
1
1
2
2975 R.P.M. DATE
VERTICAL
LOWER 0 3 BOWL DIA. 245 mm May-2001
TURBINE
STANDARD CURVE ILLUSTRATES
PUMPS SINGLE STAGE PERFORMANCE ONLY K 20.7
LOWER 2 PTS FOR PLAIN BOWL

EFFICIENCIES SHOWN ARE PUMP EFFICIENCIES - COLUMN & DRIVEHEAD LOSSES ARE NOT INCLUDED
50

45 A

40

B
35

60%
30
65%
68%
70%
25 72%
74%
TOTAL 74.6%
20
HEAD 68%
15 65%
60%
(metres)
10

5 60
A INPUT
0 40
B POWER
20
(kW)

0 20 40 60 80 100 120 140 160


VOLUMETRIC FLOWRATE (litres/second)

DATA FOR CLEAN COLD WATER ONLY PUMP PERFORMANCE TO AS2417 Pt 2 Class C
IMPELLER BOWL
IMPELLER TRIM A = 203 mm PUMP LENGTH = 685 mm
IMPELLER TRIM B = 190 mm ADDITIONAL STAGES = 222 mm
MAX. NO. OF STAGES = 20
EFFECTIVE EYE AREA = 191.6 cm² MAX. PRESS. HEAD = 280 m
NUMBER OF VANES = 5 LATERAL STD = 13 mm MAX 16 mm
WR² PER IMPELLER = .0354 kg.m² SUCTION SIZE = 200 mm
MAX. SPHERE SIZE = 25 mm DISCHARGE SIZE = 150/200/250 mm
WEIGHT = 7 kg DISCHARGE CASE DIA. = 249/249/296 mm
8618 Warrego Highway

A division of Flow Control Pacific Pty Ltd A.B.N. 83 000 922 690
WITHCOTT QLD 4352
CHANGE EFFIC. NO. OF NO. OF PUMP MODEL 250FHH CURVE NO.
AS FOLLOWS POINTS STAGES
E10442
LOWER
LOWER
2
1
1
2
1475 R.P.M. DATE
VERTICAL
LOWER 0 3 BOWL DIA. 245 mm May-2001
TURBINE
STANDARD CURVE ILLUSTRATES
PUMPS SINGLE STAGE PERFORMANCE ONLY K 20.7
LOWER 2 PTS FOR PLAIN BOWL

EFFICIENCIES SHOWN ARE PUMP EFFICIENCIES - COLUMN & DRIVEHEAD LOSSES ARE NOT INCLUDED
18

16

14
A
12

10
B
60%
8 65%
70%
73%
TOTAL 76%
77.6%
6
HEAD
4 65%
60%
(metres)
2
A

0 6
INPUT
B 4
POWER
2
(kW)

0 10 20 30 40 50 60 70 80 90 100
VOLUMETRIC FLOWRATE (litres/second)

DATA FOR CLEAN COLD WATER ONLY PUMP PERFORMANCE TO AS2417 Pt 2 Class C
IMPELLER BOWL
IMPELLER TRIM A = 203 mm PUMP LENGTH = 685 mm
IMPELLER TRIM B = 190 mm ADDITIONAL STAGES = 222 mm
MAX. NO. OF STAGES = 20
EFFECTIVE EYE AREA = 191.6 cm² MAX. PRESS. HEAD = 280 m
NUMBER OF VANES = 7 LATERAL STD = 13 mm MAX 16 mm
WR² PER IMPELLER = .0354 kg.m² SUCTION SIZE = 200 mm
MAX. SPHERE SIZE = 31 mm DISCHARGE SIZE = 150/200/250 mm
WEIGHT = 8 kg DISCHARGE CASE DIA. = 249/249/296 mm
8618 Warrego Highway

A division of Flow Control Pacific Pty Ltd A.B.N. 83 000 922 690
WITHCOTT QLD 4352
CHANGE EFFIC. NO. OF NO. OF PUMP MODEL 250FHH CURVE NO.
AS FOLLOWS POINTS STAGES
E10441
LOWER
LOWER
2
1
1
2
2980 R.P.M. DATE
VERTICAL
LOWER 0 3 BOWL DIA. 245 mm Apr-2001
TURBINE
LOWER 0 0 STANDARD CURVE ILLUSTRATES
PUMPS SINGLE STAGE PERFORMANCE ONLY K 20.7
LOWER 2 PTS FOR PLAIN BOWL

EFFICIENCIES SHOWN ARE PUMP EFFICIENCIES - COLUMN & DRIVEHEAD LOSSES ARE NOT INCLUDED
55

A
50

45

40

B
35
TOTAL 60%
30 65%
68%
HEAD 70%
72%
25
73.2%
(metres)
20
68%
65%
15 60%

10 A 60
INPUT
5 40
B POWER
0 20
(kW)

0 20 40 60 80 100 120 140 160 180 200


VOLUMETRIC FLOWRATE (litres/second)

DATA FOR CLEAN COLD WATER ONLY PUMP PERFORMANCE TO AS2417 Pt 2 Class C
IMPELLER BOWL
IMPELLER TRIM A = 203 mm PUMP LENGTH = 685 mm
IMPELLER TRIM B = 190 mm ADDITIONAL STAGES = 222 mm
MAX. NO. OF STAGES = 20
EFFECTIVE EYE AREA = 191.6 cm² MAX. PRESS. HEAD = 685 m
NUMBER OF VANES = 7 LATERAL STD = 9.5 mm MAX 15.2 mm
WR² PER IMPELLER = .0354 kg.m² SUCTION SIZE = 200 mm
MAX. SPHERE SIZE = 31 mm DISCHARGE SIZE = 150/200/250 mm
WEIGHT = 8 kg DISCHARGE CASE DIA. = 249/249/296 mm
8618 Warrego Highway

A division of Flow Control Pacific Pty Ltd A.B.N. 83 000 922 690
WITHCOTT QLD 4352
CHANGE EFFIC. NO. OF NO. OF PUMP MODEL 300RH CURVE NO.
AS FOLLOWS POINTS STAGES
E12141
LOWER
LOWER
3
1
1
2
1475 R.P.M. DATE
VERTICAL
LOWER 0 4 BOWL DIA. 286 mm May-2001
TURBINE
RAISE 1 6 STANDARD CURVE ILLUSTRATES
PUMPS SINGLE STAGE PERFORMANCE ONLY K 18
LOWER 2 PTS FOR PLAIN BOWL

EFFICIENCIES SHOWN ARE PUMP EFFICIENCIES - COLUMN & DRIVEHEAD LOSSES ARE NOT INCLUDED
22 6
NPSHR
20 4
(metres)
18 2
A

16 60% 0
B
70% 73%
76%
14 C 78%

78%
12 76%
TOTAL 81.0% 73%
79%
10 70%
HEAD
8
(metres)
6

4 12
INPUT
2 A 8
POWER
0 C 4
(kW)

0 10 20 30 40 50 60 70 80 90 100
VOLUMETRIC FLOWRATE (litres/second)

DATA FOR CLEAN COLD WATER ONLY PUMP PERFORMANCE TO AS2417 Pt 2 Class C
IMPELLER BOWL
IMPELLER TRIM A = 233 mm PUMP LENGTH = 775 mm
IMPELLER TRIM B = 224 mm ADDITIONAL STAGES = 254 mm
IMPELLER TRIM C = 214 mm MAX. NO. OF STAGES = 20
EFFECTIVE EYE AREA = 165 cm² MAX. PRESS. HEAD = 280 m
NUMBER OF VANES = 8 LATERAL STD = 16 mm MAX 20 mm
WR² PER IMPELLER = .055 kg.m² SUCTION SIZE = 200 mm
MAX. SPHERE SIZE = 19 mm DISCHARGE SIZE = 200 mm
WEIGHT = 10 kg DISCHARGE CASE DIA. = 286 mm
8618 Warrego Highway

A division of Flow Control Pacific Pty Ltd A.B.N. 83 000 922 690
WITHCOTT QLD 4352
CHANGE EFFIC. NO. OF NO. OF PUMP MODEL 300FHXM CURVE NO.
AS FOLLOWS POINTS STAGES
E12211
LOWER
LOWER
3
1
1
2
1475 R.P.M. DATE
VERTICAL
LOWER 0 3 BOWL DIA. 290 mm May-2001
TURBINE
RAISE 1 6 STANDARD CURVE ILLUSTRATES
PUMPS SINGLE STAGE PERFORMANCE ONLY K 24.5
LOWER 2 PTS FOR PLAIN BOWL

EFFICIENCIES SHOWN ARE PUMP EFFICIENCIES - COLUMN & DRIVEHEAD LOSSES ARE NOT INCLUDED
20 6
NPSHR
18 A 4
(metres)
16 2
B

14 0
60%
12 65%
70%
73%
76%
10
78.4%
TOTAL
8
HEAD
6 70%
(metres) 65%
4 60%

2 12
A INPUT
0 8
B
POWER
4
(kW)

0 10 20 30 40 50 60 70 80 90 100 110 120


VOLUMETRIC FLOWRATE (litres/second)

DATA FOR CLEAN COLD WATER ONLY PUMP PERFORMANCE TO AS2417 Pt 2 Class C
IMPELLER BOWL
IMPELLER TRIM A = 240.5 mm PUMP LENGTH = 775 mm
IMPELLER TRIM B = 231.8 mm ADDITIONAL STAGES = 280 mm
MAX. NO. OF STAGES = 15
EFFECTIVE EYE AREA = 233 cm² MAX. PRESS. HEAD = 280 m
NUMBER OF VANES = 5 LATERAL STD = 22 mm MAX 25 mm
WR² PER IMPELLER = .054 kg.m² SUCTION SIZE = 250 mm
MAX. SPHERE SIZE = 38 mm DISCHARGE SIZE = 200/250 mm
WEIGHT = 9 kg DISCHARGE CASE DIA. = 286/299 mm
8618 Warrego Highway

A division of Flow Control Pacific Pty Ltd A.B.N. 83 000 922 690
WITHCOTT QLD 4352
CHANGE EFFIC. NO. OF NO. OF PUMP MODEL 300FHM CURVE NO.
AS FOLLOWS POINTS STAGES
E12231
LOWER
LOWER
3
1
1
2
1480 R.P.M. DATE
VERTICAL
LOWER 0 3 BOWL DIA. 290 mm May-2001
TURBINE
RAISE 1 6 STANDARD CURVE ILLUSTRATES
PUMPS SINGLE STAGE PERFORMANCE ONLY K 24.5
LOWER 2 PTS FOR PLAIN BOWL

EFFICIENCIES SHOWN ARE PUMP EFFICIENCIES - COLUMN & DRIVEHEAD LOSSES ARE NOT INCLUDED
20 8
NPSHR
18 6
(metres)
A
16 4
B

14 2

60%
12 65%
70%
74%
77%
10
TOTAL 77%
78.3% 74%
8
70%
HEAD
65%
6
(metres)
4

A
2 12
B INPUT
0 8
POWER
4
(kW)

0 20 40 60 80 100 120 140 160


VOLUMETRIC FLOWRATE (litres/second)

DATA FOR CLEAN COLD WATER ONLY PUMP PERFORMANCE TO AS2417 Pt 2 Class C
IMPELLER BOWL
IMPELLER TRIM A = 240.5 mm PUMP LENGTH = 775 mm
IMPELLER TRIM B = 231.8 mm ADDITIONAL STAGES = 280 mm
MAX. NO. OF STAGES = 15
EFFECTIVE EYE AREA = 241.3 cm² MAX. PRESS. HEAD = 280 m
NUMBER OF VANES = 4 LATERAL STD = 16 mm MAX 19 mm
WR² PER IMPELLER = .0708 kg.m² SUCTION SIZE = 250 mm
MAX. SPHERE SIZE = 38 mm DISCHARGE SIZE = 200/250 mm
WEIGHT = 10 kg DISCHARGE CASE DIA. = 286/299 mm
8618 Warrego Highway

A division of Flow Control Pacific Pty Ltd A.B.N. 83 000 922 690
WITHCOTT QLD 4352
CHANGE EFFIC. NO. OF NO. OF PUMP MODEL 300FHH CURVE NO.
AS FOLLOWS POINTS STAGES
E12241
LOWER
LOWER
3
1
1
2
1480 R.P.M. DATE
VERTICAL
LOWER 0 3 BOWL DIA. 290 mm May-2001
TURBINE
RAISE 1 6 STANDARD CURVE ILLUSTRATES
PUMPS SINGLE STAGE PERFORMANCE ONLY K 24.5
LOWER 2 PTS FOR PLAIN BOWL

EFFICIENCIES SHOWN ARE PUMP EFFICIENCIES - COLUMN & DRIVEHEAD LOSSES ARE NOT INCLUDED
18 8
NPSHR
A
16 6
(metres)
B
14 4

60%
12 65% 68% 2
71% 73%
75.5%
10

68%
8 65%
TOTAL 60%
6
HEAD
4
(metres)
2

0 A 12

B INPUT
8
POWER
4
(kW)

0 20 40 60 80 100 120 140 160


VOLUMETRIC FLOWRATE (litres/second)

DATA FOR CLEAN COLD WATER ONLY PUMP PERFORMANCE TO AS2417 Pt 2 Class C
IMPELLER BOWL
IMPELLER TRIM A = 240.5 mm PUMP LENGTH = 775 mm
IMPELLER TRIM B = 231.8 mm ADDITIONAL STAGES = 280 mm
MAX. NO. OF STAGES = 15
EFFECTIVE EYE AREA = 241.3 cm² MAX. PRESS. HEAD = 280 m
NUMBER OF VANES = 8 LATERAL STD = 16 mm MAX 19 mm
WR² PER IMPELLER = .0708 kg.m² SUCTION SIZE = 250 mm
MAX. SPHERE SIZE = 19 mm DISCHARGE SIZE = 200/250 mm
WEIGHT = 11 kg DISCHARGE CASE DIA. = 286/299 mm
8618 Warrego Highway

A division of Flow Control Pacific Pty Ltd A.B.N. 83 000 922 690
WITHCOTT QLD 4352
CHANGE EFFIC. NO. OF NO. OF PUMP MODEL 350FHM CURVE NO.
AS FOLLOWS POINTS STAGES
E14131
LOWER
LOWER
2
1
1
2
1485 R.P.M. DATE
VERTICAL
LOWER 0 3 BOWL DIA. 346 mm May-2001
TURBINE
STANDARD CURVE ILLUSTRATES
PUMPS SINGLE STAGE PERFORMANCE ONLY K 43
LOWER 2 PTS FOR PLAIN BOWL

EFFICIENCIES SHOWN ARE PUMP EFFICIENCIES - COLUMN & DRIVEHEAD LOSSES ARE NOT INCLUDED
25 10
NPSHR
22.5 5
A
(metres)
20 0

B
17.5

15 60%
65%
70%
12.5 75%
78%
TOTAL 78%
10 78.5% 75%
HEAD
70%
7.5
65%
(metres) 60%
5

A
2.5 30
INPUT
B
0 20
POWER
10
(kW)

0 25 50 75 100 125 150 175 200 225 250 275 300


VOLUMETRIC FLOWRATE (litres/second)

DATA FOR CLEAN COLD WATER ONLY PUMP PERFORMANCE TO AS2417 Pt 2 Class C
IMPELLER BOWL
IMPELLER TRIM A = 285.8 mm PUMP LENGTH = 913 mm
IMPELLER TRIM B = 273.1 mm ADDITIONAL STAGES = 313 mm
MAX. NO. OF STAGES = 15
EFFECTIVE EYE AREA = 361.3 cm² MAX. PRESS. HEAD = 280 m
NUMBER OF VANES = 7 LATERAL STD = 19 mm MAX 22 mm
WR² PER IMPELLER = .122 kg.m² SUCTION SIZE = 300 mm
MAX. SPHERE SIZE = 32 mm DISCHARGE SIZE = 250/300 mm
WEIGHT = 12.7 kg DISCHARGE CASE DIA. = 356/356 mm
8618 Warrego Highway

A division of Flow Control Pacific Pty Ltd A.B.N. 83 000 922 690
WITHCOTT QLD 4352
CHANGE EFFIC. NO. OF NO. OF PUMP MODEL 350FHH CURVE NO.
AS FOLLOWS POINTS STAGES
E14141
LOWER
LOWER
3
1.5
1
2
1485 R.P.M. DATE
VERTICAL
LOWER 0 3 BOWL DIA. 346 mm May-2001
TURBINE
STANDARD CURVE ILLUSTRATES
PUMPS SINGLE STAGE PERFORMANCE ONLY K 43
LOWER 2 PTS FOR PLAIN BOWL

EFFICIENCIES SHOWN ARE PUMP EFFICIENCIES - COLUMN & DRIVEHEAD LOSSES ARE NOT INCLUDED
25 15
NPSHR
22.5 A 10
(metres)
20 B 5

17.5 0
60%
65%
15
70%
73%
75%
12.5 76.3%
TOTAL 75%
73%
10 70%
HEAD 65%
7.5 60%

(metres)
5

2.5 60
INPUT
0 A 40
POWER
B
20
(kW)

0 25 50 75 100 125 150 175 200 225 250 275 300


VOLUMETRIC FLOWRATE (litres/second)

DATA FOR CLEAN COLD WATER ONLY PUMP PERFORMANCE TO AS2417 Pt 2 Class C
IMPELLER BOWL
IMPELLER TRIM A = 285.8 mm PUMP LENGTH = 913 mm
IMPELLER TRIM B = 273.1 mm ADDITIONAL STAGES = 313 mm
MAX. NO. OF STAGES = 15
EFFECTIVE EYE AREA = 361.3 cm² MAX. PRESS. HEAD = 280 m
NUMBER OF VANES = 7 LATERAL STD = 19 mm MAX 22 mm
WR² PER IMPELLER = .122 kg.m² SUCTION SIZE = 300 mm
MAX. SPHERE SIZE = 32 mm DISCHARGE SIZE = 250/300 mm
WEIGHT = 12.7 kg DISCHARGE CASE DIA. = 356/356 mm
8618 Warrego Highway

A division of Flow Control Pacific Pty Ltd A.B.N. 83 000 922 690
WITHCOTT QLD 4352
CHANGE EFFIC. NO. OF NO. OF PUMP MODEL 400MCL CURVE NO.
AS FOLLOWS POINTS STAGES
P16121
LOWER
LOWER
2
1
1
2
1485 R.P.M. DATE
VERTICAL
BOWL DIA. 395 mm May-2001
TURBINE
STANDARD CURVE ILLUSTRATES
PUMPS SINGLE STAGE PERFORMANCE ONLY K 18.9
LOWER 2 PTS FOR PLAIN BOWL

EFFICIENCIES SHOWN ARE PUMP EFFICIENCIES - COLUMN & DRIVEHEAD LOSSES ARE NOT INCLUDED
44 12
NPSHR
40 8
(metres)
36 4

32 A 0

60%
28 B 70%
75%
78%
24 C
TOTAL 78%
20 75%
HEAD 70%
16 81.8%
80% 60%
(metres) 81%
12

8 60
INPUT
4 40

A POWER
0 20
C (kW)

0 20 40 60 80 100 120 140 160 180 200


VOLUMETRIC FLOWRATE (litres/second)

DATA FOR CLEAN COLD WATER ONLY PUMP PERFORMANCE TO AS2417 Pt 2 Class C
IMPELLER BOWL
IMPELLER TRIM A = 317.5 mm PUMP LENGTH = 867 mm
IMPELLER TRIM B = 299.2 mm ADDITIONAL STAGES = 394 mm
IMPELLER TRIM C = 279.4 mm MAX. NO. OF STAGES = 10
EFFECTIVE EYE AREA = 545.3 cm² MAX. PRESS. HEAD = 280 m
NUMBER OF VANES = 6 LATERAL STD = 15.9 mm MAX 27 mm
WR² PER IMPELLER = .217 kg.m² SUCTION SIZE = 300 mm
MAX. SPHERE SIZE = 30 mm DISCHARGE SIZE = 250/300 mm
WEIGHT = 23 kg DISCHARGE CASE DIA. = 356/356 mm
8618 Warrego Highway

A division of Flow Control Pacific Pty Ltd A.B.N. 83 000 922 690
WITHCOTT QLD 4352
CHANGE EFFIC. NO. OF NO. OF PUMP MODEL 400MCM CURVE NO.
AS FOLLOWS POINTS STAGES
P16131
LOWER
LOWER
2.5
1.5
1
2
1485 R.P.M. DATE
VERTICAL
BOWL DIA. 395 mm May-2001
TURBINE
STANDARD CURVE ILLUSTRATES
PUMPS SINGLE STAGE PERFORMANCE ONLY K 18.9
LOWER 2 PTS FOR PLAIN BOWL

EFFICIENCIES SHOWN ARE PUMP EFFICIENCIES - COLUMN & DRIVEHEAD LOSSES ARE NOT INCLUDED
50 20
NPSHR
45 15
(metres)
40 10

35 5
A

30 60%
B 70%
75%
78%
25 C
TOTAL 78%
20 75%
HEAD 70%
80.6%
15
80% 60%
(metres)
10

5 75
INPUT
0 50
POWER
A
25

C
(kW)

0 20 40 60 80 100 120 140 160 180 200 220 240


VOLUMETRIC FLOWRATE (litres/second)

DATA FOR CLEAN COLD WATER ONLY PUMP PERFORMANCE TO AS2417 Pt 2 Class C
IMPELLER BOWL
IMPELLER TRIM A = 317.5 mm PUMP LENGTH = 867 mm
IMPELLER TRIM B = 299.2 mm ADDITIONAL STAGES = 394 mm
IMPELLER TRIM C = 279.4 mm MAX. NO. OF STAGES = 10
EFFECTIVE EYE AREA = 616.4 cm² MAX. PRESS. HEAD = 280 m
NUMBER OF VANES = 6 LATERAL STD = 12.7 mm MAX 23.8 mm
WR² PER IMPELLER = .2 kg.m² SUCTION SIZE = 300 mm
MAX. SPHERE SIZE = 33 mm DISCHARGE SIZE = 250/300 mm
WEIGHT = 23 kg DISCHARGE CASE DIA. = 356/356 mm
8618 Warrego Highway

A division of Flow Control Pacific Pty Ltd A.B.N. 83 000 922 690
WITHCOTT QLD 4352
CHANGE EFFIC. NO. OF NO. OF PUMP MODEL 400KHL CURVE NO.
AS FOLLOWS POINTS STAGES
E16221
LOWER
LOWER
4
2
1
2
1485 R.P.M. DATE
VERTICAL
LOWER 0 3 BOWL DIA. 390.5 mm May-2001
TURBINE
RAISE 1 5 STANDARD CURVE ILLUSTRATES
PUMPS SINGLE STAGE PERFORMANCE ONLY K 38.4
LOWER 2 PTS FOR PLAIN BOWL

EFFICIENCIES SHOWN ARE PUMP EFFICIENCIES - COLUMN & DRIVEHEAD LOSSES ARE NOT INCLUDED
35 15

NPSHR
A
30 10

(metres)
B
25 60% 5
65%
70%
C 73%
75%
20 77% 0

TOTAL 78.1%

15
73%
HEAD 70%
10 65%
60%
(metres)
5

0 A 30

INPUT
20
C
POWER
10

(kW)

0 20 40 60 80 100 120 140 160 180 200 220 240


VOLUMETRIC FLOWRATE (litres/second)

DATA FOR CLEAN COLD WATER ONLY PUMP PERFORMANCE TO AS2417 Pt 2 Class C
IMPELLER BOWL
IMPELLER TRIM A = 309.6 mm PUMP LENGTH = 864 mm
IMPELLER TRIM B = 289.8 mm ADDITIONAL STAGES = 305 mm
IMPELLER TRIM C = 270 mm MAX. NO. OF STAGES = 10
EFFECTIVE EYE AREA = 298.7 cm² MAX. PRESS. HEAD = 280 m
NUMBER OF VANES = 8 LATERAL STD = 13 mm MAX 16 mm
WR² PER IMPELLER = .196 kg.m² SUCTION SIZE = 300 mm
MAX. SPHERE SIZE = 38 mm DISCHARGE SIZE = 250/300 mm
WEIGHT = 15.5 kg DISCHARGE CASE DIA. = 356/356 mm
8618 Warrego Highway

A division of Flow Control Pacific Pty Ltd A.B.N. 83 000 922 690
WITHCOTT QLD 4352
CHANGE EFFIC. NO. OF NO. OF PUMP MODEL 400KHH CURVE NO.
AS FOLLOWS POINTS STAGES
E16241
LOWER
LOWER
3
0
1
3
1485 R.P.M. DATE
VERTICAL
RAISE 1 6 BOWL DIA. 390.5 mm May-2001
TURBINE
STANDARD CURVE ILLUSTRATES
PUMPS SINGLE STAGE PERFORMANCE ONLY K 38.4
LOWER 2 PTS FOR PLAIN BOWL

EFFICIENCIES SHOWN ARE PUMP EFFICIENCIES - COLUMN & DRIVEHEAD LOSSES ARE NOT INCLUDED
32 16
A
NPSHR
28 12

(metres)
60%
24 B 8
70%
74%
77%
79%
20 80.8% 4

TOTAL
16 77%
74%
HEAD 70%
12
60%
(metres)
8

4 60

INPUT
0 40
A
POWER
B 20

(kW)

0 25 50 75 100 125 150 175 200 225 250 275 300


VOLUMETRIC FLOWRATE (litres/second)

DATA FOR CLEAN COLD WATER ONLY PUMP PERFORMANCE TO AS2417 Pt 2 Class C
IMPELLER BOWL
IMPELLER TRIM A = 309.6 mm PUMP LENGTH = 864 mm
IMPELLER TRIM B = 285.8 mm ADDITIONAL STAGES = 305 mm
MAX. NO. OF STAGES = 10
EFFECTIVE EYE AREA = 298.7 cm² MAX. PRESS. HEAD = 280 m
NUMBER OF VANES = 8 LATERAL STD = 13 mm MAX 16 mm
WR² PER IMPELLER = .196 kg.m² SUCTION SIZE = 300 mm
MAX. SPHERE SIZE = 38 mm DISCHARGE SIZE = 250/300 mm
WEIGHT = 15.5 kg DISCHARGE CASE DIA. = 356/356 mm
8618 Warrego Highway

A division of Flow Control Pacific Pty Ltd A.B.N. 83 000 922 690
WITHCOTT QLD 4352
CHANGE EFFIC. NO. OF NO. OF PUMP MODEL 400FHH CURVE NO.
AS FOLLOWS POINTS STAGES
E16341
LOWER
LOWER
2
1
1
2
1485 R.P.M. DATE
VERTICAL
LOWER 0 3 BOWL DIA. 397 mm May-2001
TURBINE
STANDARD CURVE ILLUSTRATES
PUMPS SINGLE STAGE PERFORMANCE ONLY K 58.6
LOWER 2 PTS FOR PLAIN BOWL

EFFICIENCIES SHOWN ARE PUMP EFFICIENCIES - COLUMN & DRIVEHEAD LOSSES ARE NOT INCLUDED
36 12
A
NPSHR
32 8
(metres)
28 B 4

60%
24 65% 0
70%
73%
20 76%
77.0%
16
73%
TOTAL 70%
12 65%
HEAD 60%
8
(metres)
4
A
0 60

B INPUT
40
POWER
20
(kW)

0 40 80 120 160 200 240 280 320 360 400


VOLUMETRIC FLOWRATE (litres/second)

DATA FOR CLEAN COLD WATER ONLY PUMP PERFORMANCE TO AS2417 Pt 2 Class C
IMPELLER BOWL
IMPELLER TRIM A = 336.6 mm PUMP LENGTH = 1003 mm
IMPELLER TRIM B = 312.8 mm ADDITIONAL STAGES = 368.3 mm
MAX. NO. OF STAGES = 10
EFFECTIVE EYE AREA = 503.3 cm² MAX. PRESS. HEAD = 280 m
NUMBER OF VANES = 5 LATERAL STD = 10 mm MAX 15 mm
WR² PER IMPELLER = .268 kg.m² SUCTION SIZE = 350 mm
MAX. SPHERE SIZE = 44 mm DISCHARGE SIZE = 300/350 mm
WEIGHT = 16.3 kg DISCHARGE CASE DIA. = 381/381 mm
8618 Warrego Highway

A division of Flow Control Pacific Pty Ltd A.B.N. 83 000 922 690
WITHCOTT QLD 4352
CHANGE EFFIC. NO. OF NO. OF PUMP MODEL 450HXB CURVE NO.
AS FOLLOWS POINTS STAGES
E18212
LOWER
RAISE
0
2
1
2
1485 R.P.M. DATE
VERTICAL
RAISE 3 3 BOWL DIA. 430 mm May-2001
TURBINE
STANDARD CURVE ILLUSTRATES
PUMPS SINGLE STAGE PERFORMANCE ONLY K 36.3
ENAMEL BOWL NOT AVAILABLE

EFFICIENCIES SHOWN ARE PUMP EFFICIENCIES - COLUMN & DRIVEHEAD LOSSES ARE NOT INCLUDED
50

45

40
A

35 60%
65%
B 70%
72%
30
C 72%
25 70%

TOTAL 65%
20
60%
HEAD 76.8%
74%
76%
15
(metres)
10

5 120
INPUT
0 80
A
POWER
40
C
(kW)

0 40 80 120 160 200 240 280 320


VOLUMETRIC FLOWRATE (litres/second)

DATA FOR CLEAN COLD WATER ONLY PUMP PERFORMANCE TO AS2417 Pt 2 Class C
IMPELLER BOWL
IMPELLER TRIM A = 339.7 mm PUMP LENGTH = 856 mm
IMPELLER TRIM B = 311.2 mm ADDITIONAL STAGES = 336 mm
IMPELLER TRIM C = 285.8 mm MAX. NO. OF STAGES = 8
EFFECTIVE EYE AREA = 417.5 cm² MAX. PRESS. HEAD = 250 m
NUMBER OF VANES = 0 LATERAL STD = 16 mm MAX 24 mm
WR² PER IMPELLER = .418 kg.m² SUCTION SIZE = 350 mm
MAX. SPHERE SIZE = 19 mm DISCHARGE SIZE = 300/350 mm
WEIGHT = 44 kg DISCHARGE CASE DIA. = 356/381 mm

8618 Warrego Highway

A division of Flow Control Pacific Pty Ltd A.B.N. 83 000 922 690
WITHCOTT QLD 4352