You are on page 1of 4

Project No. : 506111-1923 Rev.

: 0

Document No. : DSCZ5-CI-ADB-000-001 Sheet : 1 of 4

Document title:

ADDENDUM TO CIVIL, STRUCTURAL & ARCHITECTURAL


DESIGN BASIS

Shoney
0 22-Mar-18 - IMPLEMENTATION Navaj Mulla Raju Malagi
Thomas
Rev. Issue Date PEM Status Issued for Prepared by Checked by Approved by

Project : Dariba Zinc Smelter Expansion Phase IV - 100 KTPA Expansion (234 to 334 KTPA)

Client : Hindustan Zinc Limited

PC1923003_R0
Aker Powergas Pvt. Ltd www.akersolutions.com

© 2017 Aker Solutions. No part of this document or the information it contains may be reproduced or
transmitted in any form or by any means without the permission of Aker Solutions .
Project No. : 506110-1923 Rev. : 0

Document No. : DSCZ5-CI-ADB-000-001 Sheet : 2 of 4

Document Title : ADDENDUM TO CIVIL, STRUCTURAL & ARCHITECTURAL DESIGN BASIS

Amendments to Civil, Structural & Architectural Design basis (Doc no. 1564-CI-ADB-X004_R2)
Following highlighted standards and codes having latest revision.
5. STANDARDS AND CODES
5.1 Design shall be in accordance with of the Standards and Codes of Practice including the
amendments as described below :
5.1.1 Loading

IS: 875-P1-1987 Code of practice for Design Loads (Other than Earthquake) for
AMD. 1 buildings and structures: Part-1 Dead Loads - Unit weights of
Building materials and stored material.
IS: 875-P2-1987 Code of practice for Design Loads (Other than Earthquake) for
AMD.1 buildings and structures: Part-2 Imposed Loads.

IS: 875-P3-2015 Code of practice for Design Loads (Other than Earthquake) for
AMD.1 buildings and structures:Part-3 Wind Loads

IS: 875-P5-1987 Code of practice for Design Loads (Other than Earthquake) for
AMD.1 buildings and structures: Part-5 Special Loads and Load
combinations.
IS:1893-P1-2016 Criteria for Earthquake Resistant Design of Structures: Part 1
General Provision and Buildings.
AMD.1
IS:1893-P4-2015 Criteria for Earthquake Resistant Design of Structures: Part 4
Industrial Structures including Stack-Like structures.
IS:6922-1998 Criteria for Safety and Design of Structures subject to Underground
Blasts.
5.1.2 Concrete
Code of Practice for Plain and Reinforced Concrete.
IS: 456-2000
AMD. 1 TO 4
SP16 Design Aids for Reinforced Concrete to IS:456
IS:1904-1986 Code of Practice for design and construction of foundation in soils -
General Requirements.
IS: 2974-P1-1982 Code of practice for Design and Construction for Machine
AMD. 1 Foundations: Foundation for Reciprocating Type Machines.

IS: 2974-P2-1980 Code of practice for Design and Construction for Machine
AMD. 1 Foundations: Foundation for Impact type machines (Hammer
foundations)
IS: 2974-P3-1992 Code of practice for Design and Construction for Machine
Foundations: For rotary type machines (medium and high frequency)
IS: 2974-P4-1979 Code of practice for Design and Construction for Machine
AMD. 1 Foundations: Foundation for rotary type machines of low frequency.

IS: 3370-P1-2009 Code of Practice for Concrete Structures for Storage of Liquids -
General Requirements.

PC1923003_R0
Aker Powergas Pvt. Ltd www.akersolutions.com

© 2017 Aker Solutions. No part of this document or the information it contains may be reproduced or
transmitted in any form or by any means without the permission of Aker Solutions.
Project No. : 506110-1923 Rev. : 0

Document No. : DSCZ5-CI-ADB-000-001 Sheet : 3 of 4

Document Title : ADDENDUM TO CIVIL, STRUCTURAL & ARCHITECTURAL DESIGN BASIS

IS: 3370-P2-2009 Code of Practice for Concrete Structures for Storage of Liquids -
Reinforced Concrete Structure.
IS: 3370-P4-1967 Code of Practice for Concrete Structures for Storage of Liquids -
AMD.1, 2 Design Tables.

IS:13920- 2016 Ductile Detailing of Reinforced Concrete Structures subjected to


Seismic Forces
AMD.1
IS:2502-1963 Code of Practice for Bending and Fixing of Bars for Concrete
Reinforcement.
IS: 2950-P1-1981 Code of Practice for Design and Construction of Raft Foundation-
AMD. 1 Part-1 Design.
5.1.3 Steel

IS: 800-2007 Code of Practice for General Construction in Steel


AMD. 1
IS: 808-1989 Dimensions for Hot Rolled Steel Beams, Columns, Channel and
AMD. 1 angle sections.
IS: 816-1969 Code of Practice for Use of Metal Arc Welding for General
AMD. 1, 2 Construction in Mild Steel.
Steel for General Structural Purposes - Specifications
IS: 2062-2011
AMD. 1
5.1.4 Reinforcement
IS: 1786- 2008 Specifications for High Strength Deformed Steel Bars and wires for
AMD. 1, 2 & 3 concrete reinforcement.
5.1.5 Masonry
IS:1905-1987
Code of Practice for Structural Use of Un-reinforced Masonry.

5.1.6 Safety
IS:1642-2013
Code of Practice for Fire Safety of Buildings (General): Details of
Construction.
IS:1644-2013 Code of Practice for Fire Safety of Buildings (General): Exit
Requirements and Personal hazards
- Tariff Advisory Committee – Fire protection manual
- Rajasthan Factory Rules
5.1.7 Building or Architectural
SP 7-2016 National Building Code of India volum1 & volume 2

IS:1172-1993 Code of Basic Requirements for Water Supply, Drainage and


Sanitation.

5.1.8 Roads

PC1923003_R0
Aker Powergas Pvt. Ltd www.akersolutions.com

© 2017 Aker Solutions. No part of this document or the information it contains may be reproduced or
transmitted in any form or by any means without the permission of Aker Solutions.
Project No. : 506110-1923 Rev. : 0

Document No. : DSCZ5-CI-ADB-000-001 Sheet : 4 of 4

Document Title : ADDENDUM TO CIVIL, STRUCTURAL & ARCHITECTURAL DESIGN BASIS

IRC 37-2012 Tentative Guidelines for the Design of Flexible


Pavements.

Additional Specific requirements

1. Civil/Structural modifications in existing building shall be designed using the code used for existing
building design refer old CSA design basis 1564-CI-ADB-X004. New buildings & structures shall be
designed using latest codes as highlighted in above section.
2. Conbextra GP1 grout shall be used for all equipment and below all structural columns.
3. For Geotechnical data latest report from M/s CEG to be preferred.
4. Galvanised Structural steel and TMT bars to be considered.
5. Use of SRC in place of PPC/OPC to be considered in cell house acid plant, Leaching and purification
areas.
6. Bitumen mastic 10mm thick coating to be considered for substructures.
7. Acid proof tiles along with PVC to be considered in areas prone to spillage of solution with Furan
bedding.
8. Acid proof lining with PVC to be considered for all effluent drains.
9. Acid proof epoxy paint/coating to be considered for superstructures in cell house, acid plant, Leaching
and purification areas.
10. Stainless steel false ceiling to be considered in place of gypsum board.
11. Acrylic emulsion with coat of primer over prepared base with cement putty to be considered in place of
white/colour wash for painting of internal surfaces.
12. Provision of vitrified tiles of premium brand to be considered for non-plant buildings.