Readings:-
Hot Sides
Cold Sides
Trial DT 1 DT 2 DT m
1 52 40 45.7379
3624
2 52.5 44.5 48.3898
3419
3 53 46.5 49.6791
4876
4 53 48 50.4587
1888
Calculations:
q = m*Cp*DT
m = 5**V*A, =997kg/m3
V=0.052 m/s
To find U:
4.1632KW = U *A * 45.73793624
U= 439.732647 (W/m2.oC)
Cold Sides
q = m*Cp*DT
To find U:
q=U A DTm
Discussion:
The water flow rate in the hot side will transfer heat to the
cold side, where theoretically heat rejected by hot side
equals heat gained by the cold side.
In counter flow heat exchanger the flow of the hot fluid is
in opposite direction of the cold fluid.
Increasing the mass flow rate will increase q on both sides
as shown in the figures.U will also increase with the
increase of mass flow rate.
q rejected must equal q absorbed. In this experiment there
was some deviation from the law of conservation of
energy. For example q for the hot & cold sides in the 2 nd
trial: 8000
5000
Q ( W)
4000
3000
2000
1000
0
0 5 10 15 20 25
f;ow rat ( L/min)