MATERIAL TAKE-OFF LIST

ARAMCO 6228(11/2010)
REV. SAMS PER DWG.
DESCRIPTION SAP # QTY I/U STATUS REMARKS
CODE STOCK NUMBER REQ. CODE
OUTSIDE PLANT
00 MODULAR FIBER PATCH PANEL CS 6 EA
COMPLETE SET
00 CABLE ORGANIZER, IU CS 6 EA
00 FOC, SINGLE MODE, 24 CORE CS 150 MT
TIGHT BUFFERED CABLE, G.652D
00 FOC, SINGLE MODE, 24 CORE CS 1650 MT
LOOSE TUBE BUFFER CABLE
GEL-FILLED BUFFER, G.652D
00 FIBER SPLICE CLOSURE, FIRE RATED CS 3 EA
FOR 24-CORE FOC, COMPLETE SET
00 CONDUIT, 4" PVC TYPE DB, 15-312-017 1000422036 160 EA
20' LONG/PC
00 SPACER CONDUIT PVC 4" BASE 15-509-001 1000428807 580 EA
15-509-001
00 SPACER CONDUIT PVC 4" 15-509-005 1000428851 260 EA
INTERMEDIATE
00 PVC CEMENT FOR PVC CONDUIT 15-291-000 1000421845 6 CN
1 QT/CN
00 PRIMER: SOLVENT CEMENT FOR 05-511-112 1000082440 4 CN
PVC (1 PRIMER / 2 CEMENT)
00 DUCT PLUG 15-466-409 1000428195 7 EA
FOR 4" Ø PVC CONDUIT
00 4-HOLE DUCT, FOR 4" CONDUIT CS 8 EA
JACK MOON
00 SIMPLEX (SPLIT) DUCT PLUG CS 4 EA
4" JACK MOON
00 DUCT PLUG, 1" JACK MOON CS 18 EA
00 SIMPLEX (SPLIT) DUCT PLUG CS 14 EA
1" JACK MOON
00 INNERDUCT, 1" DIA. CS 220 MT
CORRUGATED POLYETHYLENE
E/W PULL ROPES, GREEN
00 INNERDUCT, 1" DIA. CS 220 MT
CORRUGATED POLYETHYLENE
ISSUED FOR CONSTRUCTION
E/W PULL ROPES, ORANGE
00 INNERDUCT, 1" DIA. CS 220 MT
CORRUGATED POLYETHYLENE
E/W PULL ROPES, BLUE
00 INNERDUCT, 1" DIA. CS 220 MT
CORRUGATED POLYETHYLENE
E/W PULL ROPES, WHITE
00 FISHLINE ROPE, 1/4'' X 07-223-390 1000154394 3 RO
2000'/ROLL
00 ORANGE WARNING TAPE: MARKING, 18-079-890 1000078516 1 RO
CAUTION TELECOMMUNICATIONS
CABLE 2000'/ROLL
00 COMPOUND: LUBRICANTWIRE 14-763-124 1000396097 5 CN
PULLING, LIQUID 5GAL PER CAN
00 ELECTRONIC MARKER: EMS CS 8 EA
3M FULL RANGE MARKER MODEL
00 SLAB: CONCRETE FOR 09-259-470 1000188305 7 EA
SURFACE MARKING 12'' X 12''
00 WASHER FOR NO. 10 SCREW; 10-883-711 7 LB
495 WASHER/LB
00 SCREW NO. 10; 1" LONG 11-291-323 70 EA
00 ANCHOR MASONRY NO. 10, MACHINE BOLT 11-806-605 70 EA

NOTES:
Issue Unit: EA - EACH, MT - METER, CN - CAN, RO - ROLL, LB - POUND
1. CONSTRUCTION CONTRACTOR SHALL VERIFY ALL REQUIRED QUANTITIES TO PERFORM THE WORK AS DETAILED IN THE DRAWINGS
2. MATERIAL LISTED WAS APPROXIMATE ONLY AND SUBJECT TO CHANGE ONCE ACTUAL CABLE ROUTE HAS BEEN VERIFIED.

APPROVAL REFERENCE DRAWING


COMPILED BY REV.
CHECKED DATE PROJECT ENGR DATE XA-103361 XA-103365
BGA 00 ECC 03/22/18 MTM 03/22/18 XA-103362 XA-103376

B.I. PHASE ENG. ITEM AREA START-UP DATE PRELIMINARY REVISION


10-01327 780 COMMUNICATION RAS TANURA 3/8/2018 FINAL X REVISION 00
INDEX Materials for UPGRADE WEST PIER FACILITIES SHEET 1 OF 8
T OUTSIDE PLANT (OSP)
PLANT TERMINAL WEST PIER MTO-CO001
P23 RAS TANURA SAUDI ARABIA
MATERIAL TAKE-OFF LIST
ARAMCO 6228(11/2010)
REV. SAMS PER DWG.
DESCRIPTION SAP # QTY I/U STATUS REMARKS
CODE STOCK NUMBER REQ. CODE
OUTSIDE PLANT
00 SIGN WARNING: SINGLE 21-565-054 1000131755 7 EA
POINTED ARROW
00 SIGN WARNING: DOUBLE 21-565-054 1000131755 4 EA
POINTED ARROW
00 SIGN WARNING: A 21-565-900 1000132038 7 EA
FOR U/G SIGN WARNING:
UNDERGROUND TEL CABLE
00 TRENCH CS 214 LM
00 CONCRETE MIXTURE 2000 PSI CS
0.712(W) X 0.412M(D) X 3.0M (L) 46 CM
0.412M(W) X 0.262M(D) X22.0M (L) 4 CM
0.412M(W) X 0.412M(D) X 189M (L) 23 CM
00 BACKFILLING 0.7M(W) X 1.2M(D) X 214M (L) CS 180 CM
00 CABLE TEL. ASPIC-FILLED 18-016-770 130 EA
25 PRx22AWG (0.72" OD)
00 TAPE INSULATING FIRE PROOF 14-908-398 1000408019 8 RO
1 1/2 X 20'LONG
00 PEDESTAL; TYPE: UP-1000 CS 1 EA
COMPLETE SET, WITH MOUNTING STAKE
00 PEDESTAL; TYPE: UP-1278 CS 1 EA
COMPLETE SET, WITH MOUNTING STAKE
00 CONNECTOR: GROUND, FOR 14-103-480 1000364911 2 EA
5/8'' GROUND ROD
00 GROUND ROD; COPPERWELD, 14-246-542 1000379015 2 EA
16MM (5/8'') DIA. X 2.4M (8.0') LONG
00 WIRE, BARE COPPER, NO. 6 AWG 15-043-124 1000413915 4 FT
SOFT DRAWN
00 CLOSURE BURIED CABLE; 25-PAIRS CS 1 EA
SPLICING
00 TIE: CABLE, STRAP TYPE; NYLON 15-510-081 1000429062 3 PK
SELF LOCKING, 13.93" LONG,50/PK
00 TIE: CABLE, LASHING TYPE, 15-525-022 1000429955 3 PK
NYLON (BLACK) SELF-LOCKING, ISSUED FOR CONSTRUCTION
8.0'' LONG, 250/PK
00 KIT CLEANING FILLED CORE CABLE 18-021-275 3 KT
00 CONNECTOR "UR" SCOTCHLOK 100/BOX 18-021-952 3 BX
CONNECTOR SHIELD NO. 4460 100/CT 18-021-990 3 CT
00 TAG: CABLE MARKING 18-079-845 1000078511 3 PK
54 MM W X 95.3 MM L X 1.2 MM T
GRAY, LEAD, TERMINAL, 25/PK
00 TAPE VINYL 88T 3/4"X36' ROLL 18-079-940 3 RO
00 TAG: CABLE MARKING 18-079-843 1000078420 1 PK
44.5 MM W X 304.8 MM L X 1.2 MM T
GRAY, LEAD, STRAP, SLOT, 25/PK
00 COUPLING FOR 4" PVC CONDUIT 1000-424-100 10 EA
00 BEND CONDUIT; PVC 4" 90 DEG; 1000-424-943 10 EA
36" RADIUS
00 PLASTIC CAPS, 4" 1000-051-849 17 EA
00 CASE SPLICE S.S. 4.0" #8000-624 18-018-364 1 EA
00 PLYWOOD EXTERIOR 3/4"X4'X8' 09-565-176 1 EA
00 PAINT; FIRE RETARDANT 5LT/CN 09-685-469 2 EA
00 COUPLING FOR 4" PVC CONDUIT 1000-424-100 10 EA
00 BEND CONDUIT; PVC 4" 90 DEG; 1000-424-943 10 EA
36" RADIUS
00 PLASTIC CAPS, 4" 1000-051-849 17 EA
NOTES:
Issue Unit: EA - EACH, LM - LINEAR METER, CM - CUBIC METER, FT - FEET, PK - PACK, KT - KIT, BX - BOX, RO - ROLL, CT - CARTON
1. CONSTRUCTION CONTRACTOR SHALL VERIFY ALL REQUIRED QUANTITIES TO PERFORM THE WORK AS DETAILED IN THE DRAWINGS
2. MATERIAL LISTED WAS APPROXIMATE ONLY AND SUBJECT TO CHANGE ONCE ACTUAL CABLE ROUTE HAS BEEN VERIFIED.

APPROVAL REFERENCE DRAWING


COMPILED BY REV.
CHECKED DATE PROJECT ENGR DATE XA-103361 XA-103365
BGA 00 ECC 03/22/18 MTM 03/22/18 XA-103362 XA-103376

B.I. PHASE ENG. ITEM AREA START-UP DATE PRELIMINARY REVISION


10-01327 780 COMMUNICATION RAS TANURA 3/8/2018 FINAL X REVISION 00
INDEX Materials for UPGRADE WEST PIER FACILITIES SHEET 2 OF 8
T OUTSIDE PLANT (OSP)
PLANT TERMINAL WEST PIER MTO-CO001
P23 RAS TANURA SAUDI ARABIA
MATERIAL TAKE-OFF LIST
ARAMCO 6228(11/2010)
REV. SAMS PER DWG.
DESCRIPTION SAP # QTY I/U STATUS REMARKS
CODE STOCK NUMBER REQ. CODE
OUTSIDE PLANT
00 489ACC1-025 BLDG ENTRANCE 107894941 1 EA
TERMINAL,W/ STUB-CABLE 25X26 AWG
00 4C1S BLDG ENTRANCE 104386545 25 EA
SOLID STATE PROTECTOR UNIT
00 110 WIRING BLOCK 100-PRS WITH CS 1 EA
110C4 CONNECTING BLOCKS
00 CABLE MANAGER CS 4 EA

ISSUED FOR CONSTRUCTION

NOTES:
Issue Unit: EA - EACH
1. CONSTRUCTION CONTRACTOR SHALL VERIFY ALL REQUIRED QUANTITIES TO PERFORM THE WORK AS DETAILED IN THE DRAWINGS
2. MATERIAL LISTED WAS APPROXIMATE ONLY AND SUBJECT TO CHANGE ONCE ACTUAL CABLE ROUTE HAS BEEN VERIFIED.

APPROVAL REFERENCE DRAWING


COMPILED BY REV.
CHECKED DATE PROJECT ENGR DATE XA-103361 XA-103365
BGA 00 ECC 03/22/18 MTM 03/22/18 XA-103362 XA-103376

B.I. PHASE ENG. ITEM AREA START-UP DATE PRELIMINARY REVISION


10-01327 780 COMMUNICATION RAS TANURA 3/8/2018 FINAL X REVISION 00
INDEX Materials for UPGRADE WEST PIER FACILITIES SHEET 3 OF 8
T OUTSIDE PLANT (OSP)
PLANT TERMINAL WEST PIER MTO-CO001
P23 RAS TANURA SAUDI ARABIA
MATERIAL TAKE-OFF LIST
ARAMCO 6228(11/2010)
REV. SAMS PER DWG.
DESCRIPTION SAP # QTY I/U STATUS REMARKS
CODE STOCK NUMBER REQ. CODE
STRUCTURE CABLING SYSTEM
00 TGB (2"Wx1/4"Hx14"L) CS 1 EA
00 TERMINAL LUG YA6C-2L CS 4 EA
00 TERMINAL LUG; YA28L-2TC38 CS 1 EA
00 GREEN WIRE ELECTRICAL: #6 AWG CS 1000419283 8 MT
00 GROUNDING WIRE: 2/0 AWG BARE CS 6 MT
STRANDED; TINNED COPPER
00 2" GRC CONDUIT SLEEVE CS 1 EA
FOR GROUNDING
00 2" BUSHING WITH NUTS
00 1" EMT CONDUIT; 3M LONG CS 4 EA
00 1" BUSHING WITH NUTS
00 4" GRC CONDUIT CS 2 EA
00 4" GRC-PVC ADAPTER CONDUIT CS 2 EA
00 4" BUSHING WITH NUTS CS 2 EA
00 CABINET ENCLOSURE, NEMA 12 CS 1 EA
(60"Hx 36"Wx10"D)
00 CLAMP CS 6 EA
00 ABAHSAIN, SLOTTED CHANNEL, CS 2 PC
1-5/8" X 1-5/8" X 10' L PN P1000T
00 ABAHSAIN, REGULAR SPRING CS 8 PC
NUT, PN: A-100-M10-EG
00 ABAHSAIN, HEX NUT, PN: E-145-M10-EG CS 16 PC
00 ABAHSAIN, FLAT WASHER, PN: E-147-M10-EG CS 16 PC
00 ABAHSAIN, LOCK WASHER, PN: E-148-M10-EG CS 8 PC
00 ABAHSAIN, HEX. HEAD PN: M10X30HS CS 8 PC
00 CABINET, CUBE-iT 24"x24"x24" CS 1 EA
00 CABINET,800mm (W) X 800mm (D) X 7' (H) CS 1 EA
00 HORIZONTAL WIRE MANAGEMENT BAR (CPI) 12787-524 2 EA
00 EXTRA MOUNTING RAILS (CPI) 11837-201 2 EA
00 FAN KIT (CPI) 12804-701 2 EA
00 SURGE PROTECTED POWER STRIP (CPI) 12820-707 2 EA
00 LIGHT KIT (CPI) 12803-701 2 EA
00 METAL D-RINGS,SMALL (CPI) 10941-000 10 EA ISSUED FOR CONSTRUCTION
00 MGS400-318 GIGA SPEED XL, MODULAR 700206758 2 EA
IDC-RJ45 OUTLET, CAT 6, T568A/B, BLUE
00 MODULAR FACEPLATE, FLUSH, 2-PORT, 108168550 1 EA
SINGLE GANG FLUSH, ELECTRICAL IVORY
00 DUPLEX FLUSH MOUNTED 106622277 1 EA
MOUNTING FRAMES, ELECTRICAL IVORY
00 MP20AP-246 DUST COVER, 107067860 1 EA
ELECTRICAL IVORY
00 CMP CAT 6; 2071E GIGA SPEED XL 700208093 20 MT
4-PAIR, 23 AWG, , BLUE , 305M/BOX
00 PANASONIC TELEPHONE CS 1 EA
P/N: KX-TSC35SU-W

NOTES:
Issue Unit: EA - EACH, MT - METER, PC - PIECE
1. CONSTRUCTION CONTRACTOR SHALL VERIFY ALL REQUIRED QUANTITIES TO PERFORM THE WORK AS DETAILED IN THE DRAWINGS
2. MATERIAL LISTED WAS APPROXIMATE ONLY AND SUBJECT TO CHANGE ONCE ACTUAL CABLE ROUTE HAS BEEN VERIFIED.

APPROVAL REFERENCE DRAWING


COMPILED BY REV.
CHECKED DATE PROJECT ENGR DATE XA-103384.002 XA-103368
BGA 00 ECC 03/22/18 MTM 03/22/18 XA-103363 XA-103386.001-002

B.I. PHASE ENG. ITEM AREA START-UP DATE PRELIMINARY REVISION


10-01327 780 COMMUNICATION RAS TANURA 3/8/2018 FINAL X REVISION 00
INDEX Materials for UPGRADE WEST PIER FACILITIES SHEET 4 OF 8
T OUTSIDE PLANT (OSP)
PLANT TERMINAL WEST PIER MTO-CO001
P23 RAS TANURA SAUDI ARABIA
MATERIAL TAKE-OFF LIST
ARAMCO 6228(11/2010)
REV. SAMS PER DWG.
DESCRIPTION SAP # QTY I/U STATUS REMARKS
CODE STOCK NUMBER REQ. CODE
OUTSIDE PLANT (Non-IT)
PIB-1 TO BERTHS
00 PIPE: STEEL , SEAMLESS, 4'' 01-167-390 1000000749 1092 FT
NOM; 6.02MM (0.237'') WALL (USE
FOR PEDESTAL GUARD)

00 PRIMER: SOLVENT CEMENT, 05-511-112 1000082440 65 CN


PURPLE COLOR, 1 QT CAN, FOR
PVC CONDUIT & FITTING JOINTS

00 FISHLINE ROPE, 1/4'' X 2000'/ROLL 07-223-390 1000154394 13 RO

00 PAINT: ENAMEL YELLOW; 09-630-794 1000195683 9 CN


EXTERIOR/INTERIOR; 5LT/CAN

00 PRIMER; SURFACE GRAY, 5LT/CAN 09-709-683 1000198055 9 CN

00 THINNER, METYL ETHYL KETONE, 5LT/CAN 09-739-211 1000198570 3 CN

00 WASHER FOR NO. 10 SCREW; 495 10-883-711 1000231530 2 EA

00 SCREW NO. 10; 1'' LONG 11-291-323 1000257725 636 EA

00 CONNECTOR: GROUND, FOR 14-103-480 1000364911 27 EA


5/8'' GROUND ROD

00 CONNECTOR; TERMINAL; FOR 14-197-951 1000374097 54 EA


#6 WIRE; CRIMP TYPE

00 CONNECTOR TERMINAL LUG 14-198-119 1000374502 27 EA


(1) 9.5 MM (3/8 IN) HOLE
TERMINATION13.3 SQ MM
(6 AWG) STRANDED COPPER

00 CONNECTOR: GROUNDING;: 14-114-461 1000366947 27 EA


TAP, SPLIT-BOLT
ISSUED FOR CONSTRUCTION
00 GROUND ROD; COPPERWELD, 14-246-542 1000379015 27 EA
16MM (5/8'') DIA. X 2.4M (8.0') LONG

00 COMPOUND: LUBRICANT WIRE 14-763-124 1000396097 10 CN


PULLING, LIQUID 5GAL/CAN, USE
ON RUBBER & PLASTIC COATED
WIRE IN STEEL, ALUM OR
PLASTIC CONDUIT

00 TAPE INSULATING FIRE PROOF 14-908-398 1000408019 12 RO


1-1/2" x 20' LONG

00 WIRE, BARE COPPER, NO. 6AWG 15-043-124 1000413915 532 FT


SOFT DRAWN

00 #6 AWG INSULATED COPPER WIRE (GREEN) 15-194-396 1000419283 40 FT

00 ADHESSIVE: SOLVENT CEMENT, 15-291-000 1000421845 404 CN


4.38 DEG C LIQUID, 0.95 L (1 QT)
CAN, ASTM D2564, CONDUIT
CEMENT, FOR PVC:

00 SIMPLEX DUCT PLUG, 1'' DIA. CONTRACTOR SUPPLY 404 EA


INNERDUCT P63-15-1009 DA6#4
NOTES:
Issue Unit: EA - EACH, FT - FEET, CN - CAN, RO - ROLL
1). CONSTRUCTION CONTRACTOR SHALL VERIFY ALL REQUIRED QUANTITIES TO PERFORM THE WORKS AS SHOWN ON THE DESIGN DRAWINGS
2). ALL OTHER MATERIALS NOT SHOWN ON THE DRAWINGS BUT REQUIRED FOR THE SYSTEM FULL FUNCTIONALITY SHALL BE PROVIDED BY THE CONTRACTOR

APPROVAL
COMPILED BY REV. REFERENCE DRAWING
CHECKED DATE PROJECT ENGR DATE
GTI 00 ECC 03/22/18 MTM 03/22/18 XA-103380 XA-103381
XA-103376 XA-103383
B.I. PHASE ENG. ITEM AREA START-UP DATE PRELIMINARY REVISION
10-01327 780 COMMUNICATION RAS TANURA 3/8/2018 FINAL X REVISION 00
INDEX Materials for OUTSIDE PLANT SYSTEM (NON-IT) SHEET 5 OF 8
J PIB-1 TO BERTHS #1-12 FOC CONNECTIVITY
PLANT TERMINAL WEST PIER MTO-CO001
056 RAS TANURA SAUDI ARABIA
MATERIAL TAKE-OFF LIST
ARAMCO 6228(11/2010)
REV. SAMS PER DWG.
DESCRIPTION SAP # QTY I/U STATUS REMARKS
CODE STOCK NUMBER REQ. CODE
OUTSIDE PLANT (Non-IT)
PIB-1 TO BERTHS
00 CONDUIT: PVC, 4'' DIA NOM. 15-312-017 1000422036 1295 PC
6.1M LG DIRECT BURIAL,
BELLED ONE END, GRAY,
EXTRA STRENGTH, NEMA TC-8,
3.91MM MIN. WALL THK TYPE DB

00 COUPLING: CONDUIT: 4" NOM, 15-333-809 1000424100 48 PC


SOCKET, RIGID, PVC, NATURAL,
UNPLASTICIZED, NEMA TC-9
FOR DIRECT BURIAL OR
CONCRETE ENCASED

00 BEND:CONDUIT PVC4'' DIA 90 15-366-721 1000424943 24 PC


DEG. SLIP-ON, DIRECT BURIAL,
3.91MM WALL THK, MOLDING,
36'' RADIUS, ASTM F512
NEMA TC-9, TC-8

00 SPACER, CONDUIT PVC 4", BASE SECTION 15-509-001 1000428807 4233 PC

00 SPACER, CONDUIT PVC 4", 15-509-005 1000428851 1768 PC


INTERMEDIATE SECTION

00 TIE: CABLE, STRAP TYPE; NYLON, 15-510-081 1000429062 2 PK


SELF LOCKING, 13.93" LONG, 50/PK

00 TIE: CABLE, LASHING TYPE, 15-525-022 1000429955 2 PK


NYLON (BLACK) SELF-LOCKING,
8.0'' LONG, 50/PK

00 TIES, SELF LOCKING 13.4" LONG, 50/PK 15-525-030 1000429989 1 PK

00 CEMENT , RUBBER "C" 4 OZ/CAN 18-013-368 1000076939 0 CN

00 CONDUIT, RSC PVC COATED 15-314-922 6 PC ISSUED FOR CONSTRUCTION


4" X 10' LONG

00 LOCNUT 4" CONDUIT STEEL GALV 15-421-354 24 EA

00 BUSHING 4" CONDUIT STEEL GALV CONTRACTOR SUPPLY

00 ANCHOR MASONRY NO. 10 11-806-605 1000269073 84 EA

00 DIN SPACE COMPACT FIBER OPTIC PATCH CONTRACTOR SUPPLY 24 EA


PANEL, PART# SNAP-12SC-SM

00 KIT CLEANING FILLED CORE CABLE 18--021-275 4 KT

00 WALL-MOUNT ENCLOSURE TYPE 4X


SINGLE DOOR (STAINLESS STEEL) CONTRACTOR SUPPLY 12 EA
610MM(H) x 610MM(W) x 305MM(D)

00 CONDUIT RSC PVC COATED 1"x10' LONG 15-314-914 6 PC

00 4-HOLES DUCT, FOR 4" CONDUIT CONTRACTOR SUPPLY 170 EA


JACK MOON MODEL #40Q136S

00 DUCT PLUG 1", JACK MOON, MODEL #10D104U CONTRACTOR SUPPLY 258 EA

NOTES:
Issue Unit: EA - EACH, PC - PIECE, CN - CAN, KT - KIT, FT - FEET, PK - PACK, CT - CARTON, BX - BOX
1). CONSTRUCTION CONTRACTOR SHALL VERIFY ALL REQUIRED QUANTITIES TO PERFORM THE WORKS AS SHOWN ON THE DESIGN DRAWINGS
2). ALL OTHER MATERIALS NOT SHOWN ON THE DRAWINGS BUT REQUIRED FOR THE SYSTEM FULL FUNCTIONALITY SHALL BE PROVIDED BY THE CONTRACTOR

APPROVAL
COMPILED BY REV. REFERENCE DRAWING
CHECKED DATE PROJECT ENGR DATE
GTI 00 ECC 03/22/18 MTM 03/22/18 XA-103380 XA-103381
XA-103376 XA-103383
B.I. PHASE ENG. ITEM AREA START-UP DATE PRELIMINARY REVISION
10-01327 780 COMMUNICATION RAS TANURA 3/8/2018 FINAL X REVISION 00
INDEX Materials for OUTSIDE PLANT SYSTEM (NON-IT) SHEET 6 OF 8
J PIB-1 TO BERTHS #1-12 FOC CONNECTIVITY
PLANT TERMINAL WEST PIER MTO-CO001
056 RAS TANURA SAUDI ARABIA
MATERIAL TAKE-OFF LIST
ARAMCO 6228(11/2010)
REV. SAMS PER DWG.
DESCRIPTION SAP # QTY I/U STATUS REMARKS
CODE STOCK NUMBER REQ. CODE
OUTSIDE PLANT (Non-IT)
PIB-1 TO BERTHS
00 PLUG: CONDUIT, 4", THREADED, ROUND HD, 18-062-193 1000078036 170 EA
EXPANDABLE, RUBBER ZINC ELECTROPLATE
SOLID FOR SEALING UNOCCUPIED DUCTS

00 HORIZONTAL BUS BAR CONTRACTOR SUPPLY 1 EA


(For 7' x19" Equipment Rack)

00 PLUG: CONDUIT, SPLIT RUBBER, 18-062-150 1000078005 0 EA


EXPANDING, 4'' X 1-1/2" OD
(FOR CABLE 100PR)

00 PLUG: CONDUIT, SPLIT RUBBER, 18-062-153 1000078009 0 EA


EXPANDING, 4'' X 1-3/4" OD
(FOR CABLE 200-300PR)

00 TAG; CABLE STRAP, LEAD, 25/PK 18-079-843 1000078420 4 PK

00 TAG: CABLE MARKING 18-079-845 1000078511 5 PK


54 MM W x 95.3 MM L x 1.2 MM T
GRAY, LEAD, TERMINAL, 25/PK

00 TAPE BINDING NON ADHESIVE 3" x 35' / ROLL 18-079-875 1000078513 0 RO

00 WARNING TAPE: SAFETY BARRIER: 18-079-890 1000078516 0 RO


MARKING, CAUTION TELECOMMUNICATIONS
CABLE, 1000'/ROLL

00 TAPE VINYL 88T 3/4" x 36' / ROLL 18-079-940 1000078523 0 RO

00 TAPE: RUBBER, SCOTCH, NO. 23, 3/4" x 30' / ROLL 18-080-020 1000078558 0 RO

00 TAPE: SPLICING RUBBER: 2" x 20'/ROLL 18-080-025 1000078598 0 RO

00 SIGN WARNING: SINGLE POINTED ARROW 21-565-054 1000131755 0 EA ISSUED FOR CONSTRUCTION

00 SIGN WARNING: DOUBLE POINTED ARROW 21-565-135 1000131800 53 EA

00 SIGN WARNING: A CONTRACTOR SUPPLY 53 EA


FOR U/G SIGN WARNING:
UNDERGROUND INSTRUMENT CABLE

00 MARKER POST: FIBER GLASS CONTRACTOR SUPPLY 46 EA


ORANGE IN COLOR

00 SUBDUCT: PVC 1'' DIA. CONTRACTOR SUPPLY 5085 MT


CORRUGATED, POLYETHYLENE,
WHITE WITH 1/4'' PULL-ROPE

00 SUBDUCT: PVC 1'' DIA. CONTRACTOR SUPPLY 5085 MT


CORRUGATED, POLYETHYLENE,
ORANGE WITH 1/4'' PULL-ROPE

00 SUBDUCT: PVC 1'' DIA. CONTRACTOR SUPPLY 5085 MT


CORRUGATED, POLYETHYLENE,
BLUE WITH 1/4'' PULL-ROPE

00 SUBDUCT: PVC 1'' DIA. CONTRACTOR SUPPLY 5085 MT


CORRUGATED, POLYETHYLENE,
GREEN WITH 1/4'' PULL-ROPE
NOTES:
Issue Unit: EA - EACH, PK - PACK, RO - ROLL, MT - METER
1). CONSTRUCTION CONTRACTOR SHALL VERIFY ALL REQUIRED QUANTITIES TO PERFORM THE WORKS AS SHOWN ON THE DESIGN DRAWINGS
2). ALL OTHER MATERIALS NOT SHOWN ON THE DRAWINGS BUT REQUIRED FOR THE SYSTEM FULL FUNCTIONALITY SHALL BE PROVIDED BY THE CONTRACTOR

APPROVAL
COMPILED BY REV. REFERENCE DRAWING
CHECKED DATE PROJECT ENGR DATE
GTI 00 ECC 03/22/18 MTM 03/22/18 XA-103380 XA-103381
XA-103376 XA-103383
B.I. PHASE ENG. ITEM AREA START-UP DATE PRELIMINARY REVISION
10-01327 780 COMMUNICATION RAS TANURA 3/8/2018 FINAL X REVISION 00
INDEX Materials for OUTSIDE PLANT SYSTEM (NON-IT) SHEET 7 OF 8
J PIB-1 TO BERTHS #1-12 FOC CONNECTIVITY
PLANT TERMINAL WEST PIER MTO-CO001
056 RAS TANURA SAUDI ARABIA
MATERIAL TAKE-OFF LIST
ARAMCO 6228(11/2010)
REV. SAMS PER DWG.
DESCRIPTION SAP # QTY I/U STATUS REMARKS
CODE STOCK NUMBER REQ. CODE
OUTSIDE PLANT (Non-IT)
PIB-1 TO BERTHS
00 WARNING TAPE W/ METTALIZED FOIL: SAFETY CONTRACTOR SUPPLY 8 RL
BARRIER MARKING, CAUTION TELECOMMS
CABLE, 1000'/ROLL

00 3M CAULK FIRE BARRIER (DSCO) CONTRACTOR SUPPLY 7 TU

00 FPP: 360G2 MODULAR 1U, SLIDING SHELF CONTRACTOR SUPPLY 12 EA


PN: 360G2-1U-MOD-SD, MAT ID 760103085
SYSTIMAX 360 SOLUTION

00 INSTAPATCH 360 MODULES, 12SC-SM, FOR CONTRACTOR SUPPLY 48 EA


SINGLE MODE FIBER, PN: 360DM-12SC-SM
MAT ID 760109975, SYSTIMAX 360 SOLUTION

00 FOC, SINGLEMODE, 12 CORE CONTRACTOR SUPPLY 11,314 MT


GEL- FILLED LOOSE TUBE, NON-METALLIC
ITU-T-G652D & 18-SAMSS-625 Compliant

00 BLIND END 305 mm W x 90mm H, (ABAHSAIN) C90-4-305 BE 2 EA

00 3M, 2170, FIBER OPTIC CONTRACTOR SUPPLY 288 EA


FUSION SPLICE PROTECTOR
SLEEVES, 3.0MM x 6.0MM

00 BURIED CLOSURE: PEDESTAL TYPE UP-1000, CONTRACTOR SUPPLY 27 EA


EMERSON, WITH MOUNTING STAKE AND
ALL RELATED ACCESSORIES

00 SLAB: CONCRETE FOR 09-259-470 1000188305 14 EA


SURFACE MARKING 12'' X 12''

00 GROUND BAR 4"(L) x 1" (W) CONTRACTOR SUPPLY 12 EA


(To be installed inside the NEMA-4X Enclosure)
ISSUED FOR CONSTRUCTION

00 C-CHANNEL, 100mm(H) x 50mm x5mm(T), 10' LONG CONTRACTOR SUPPLY 0 PC

00 4" DIA. CONDUIT CLAMP CONTRACTOR SUPPLY 24 EA

00 CHANNEL SINGLE 1-5/8" x 1-5/8" x 10' LONG 15-430-040 6 PC

00 SELF SUPPORT UNIVERSAL RACK, 7'H x 19"W 463-53-503 (DC) 1 EA


(CPI) WITH MOUNTING BASE ANGLES SUPPORTS

00 VERTICAL RACK CABLING SECTION 7'H (CPI) 11374-503 1 EA

00 CABLE ORGANIZER, 1U CONTRACTOR SUPPLY 6 EA

00 CABLE TRAY 305mm W x 90mm H x 2.4M 364-155SL-2.44M 3 EA


LENGTH (C-PROFILE), ABAHSAIN COPE

00 WARNING TAPE W/ METTALIZED FOIL: SAFETY CONTRACTOR SUPPLY 8 RL


BARRIER MARKING, CAUTION TELECOMMS
CABLE, 1000'/ROLL

00 FITTINGS 90 DEGREE HORIZONTAL ELBOW CONTRACTOR SUPPLY 1 EA


300mm RADIUS, 305MM WIDE X 90MM
NOTES:
Issue Unit: EA - EACH, MT -METER, TU - TUBE, KT - KIT, CM - CUBIC METER, RO - ROLL
1). CONSTRUCTION CONTRACTOR SHALL VERIFY ALL REQUIRED QUANTITIES TO PERFORM THE WORKS AS SHOWN ON THE DESIGN DRAWINGS
2). ALL OTHER MATERIALS NOT SHOWN ON THE DRAWINGS BUT REQUIRED FOR THE SYSTEM FULL FUNCTIONALITY SHALL BE PROVIDED BY THE CONTRACTOR

APPROVAL
COMPILED BY REV. REFERENCE DRAWING
CHECKED DATE PROJECT ENGR DATE
GTI 00 ECC 03/22/18 MTM 03/22/18 XA-103380 XA-103381
XA-103376 XA-103383
B.I. PHASE ENG. ITEM AREA START-UP DATE PRELIMINARY REVISION
10-01327 780 COMMUNICATION RAS TANURA 3/8/2018 FINAL X REVISION 00
INDEX Materials for OUTSIDE PLANT SYSTEM (NON-IT) SHEET 8 OF 8
J PIB-1 TO BERTHS #1-12 FOC CONNECTIVITY
PLANT TERMINAL WEST PIER MTO-CO001
056 RAS TANURA SAUDI ARABIA