INSULATION RESISTANCE REPORT

Vessel : F/B PMC 08 Date :

Volt Insulation Resistance


Name of Circuit Capacity Machinery Line
(V)
(MΩ) (MΩ)
1. Auxillary # 1
220 60 KVA R 30.00 X 50.00
S 25.00 Y 50.00
T 25.00 Y 50.00
2. Auxillary # 2
220 60 KVA R 20.00 X 30.00
S 15.00 Y 30.00
T 15.00 Y 30.00
3. Fresh Water Pump Motor
220 2.2 KW R 300.00 X 260.00
S 300.00 Y 260.00
T 300.00 Y 270.00
4. General Service Pump Motor
220 2.2 KW R 290.00 X 200.00
S 290.00 Y 210.00
T 260.00 Y 210.00
5. Brine Pump Motor
220 2.2 KW R 300.00 X 280.00
S 300.00 Y 270.00
T 300.00 Y 270.00
6. Steering Motor
220 2.2 KW R 400.00 X 280.00
S 400.00 Y 300.00
T 400.00 Y 300.00
7. Hauler Hydraulic Pump Motor
220 11 KW R 180.00 X 90.00
S 190.00 Y 90.00
T 190.00 Y 90.00

Conducted & Prepared by : Noted by :


ATION RESISTANCE REPORT

November 8, 2018

Remarks

OK
OK
OK

OK
OK
OK

OK
OK
OK

OK
OK
OK

OK
OK
OK

OK
OK
OK

OK
OK
OK