You are on page 1of 7

Consider a two-stage cascade refrigeration system operating between the pressure limits of 1.

1 MPa and
150 kPa with refrigerant-134a as the working fluid. The refrigerant leaves the condenser as a saturated liquid
and is throttled to a flash chamber operating at 0.55 MPa. Part of the refrigerant evaporates during this
flashing process and this vapor is mixed with the refrigerant leaving the low-pressure compressor. The
mixture is then compressed to the condenser pressure by the high-pressure compressor. The liquid in the
flash chamber is throttled to the evaporator pressure and cools the refrigerated space as it vaporizes in the
evaporator. The mass flow rate of the refrigerant through the low-pressure compressor is 0.08 kg/s. Assuming
the refrigerant leaves the evaporator as a saturated vapor and the isentropic efficiency is 82% for both
compressors, determine (a) the mass flow rate of the refrigerant through the high-pressure compressor, (b)
the rate of heat removal from the refrigerated space, and (c) the COP of this refrigerator. Also, determine
(d) the rate of heat removal and the COP if this refrigerator operated on a single-stage cycle between the
same pressure limits with the same compressor efficiency and the same flow rate as in part (a).
Considere un sistema de refrigeración en cascada de dos etapas que funcione entre los
límites de presión de 1.1 MPa y 150 kPa con refrigerante-134a como fluido de trabajo.
El refrigerante sale del condensador como un líquido saturado y se regula a una cámara
de flash que funciona a 0.55 MPa. Parte del refrigerante se evapora durante este proceso
de destello y este vapor se mezcla con el refrigerante que sale del compresor de baja
presión. La mezcla se comprime luego a la presión del condensador mediante el
compresor de alta presión. El líquido en la cámara de flash se acelera a la presión del
evaporador y enfría el espacio refrigerado a medida que se evapora en el evaporador.
El caudal másico del refrigerante a través del compresor de baja presión es de 0.08 kg
/ s. Suponiendo que el refrigerante salga del evaporador como un vapor saturado y que
la eficiencia isentrópica sea del 82% para ambos compresores, determine (a) el caudal
másico del refrigerante a través del compresor de alta presión, (b) la tasa de
eliminación de calor del refrigerado espacio, y (c) el COP de este refrigerador. Además,
determine (d) la tasa de eliminación de calor y el COP si este refrigerador funcionó en
un ciclo de una sola etapa entre los mismos límites de presión con la misma eficiencia
del compresor y la misma tasa de flujo que en la parte (a).
Consider a two-stage cascade refrigeration system operating between the pressure limits of 1.3 MPa and 160 kPa with
refrigerant-134a as the working fluid. Heat rejection from the lower cycle to the upper cycle takes place in an
adiabatic counterflow heat exchanger where the pressure in the upper and lower cycles are 0.4 and 0.5 MPa,
respectively. In both cycles, the refrigerant is a saturated liquid at the condenser exit and a saturated vapor at the
compressor inlet, and the isentropic efficiency of the compressors for high and low pressure are 85 and 90 percent,
respectively. If the mass flow rate of the refrigerant through the lower cycle is 0.11 kg/s, determine (a) the mass flow
rate of the refrigerant through the upper cycle, (b) the rate of heat removal from the refrigerated space, and (c) the
COP of this refrigerator.
Considere un sistema de refrigeración en cascada de dos etapas que opera entre los límites de presión
de 1.3 MPa y 160 kPa con refrigerante-134a como fluido de trabajo. El rechazo de calor desde el ciclo
inferior al ciclo superior tiene lugar en un intercambiador de calor de contraflujo adiabático donde la
presión en los ciclos superior e inferior es de 0,4 y 0,5 MPa, respectivamente. En ambos ciclos, el
refrigerante es un líquido saturado a la salida del condensador y un vapor saturado en la entrada del
compresor, y la eficiencia isentrópica de los compresores para alta y baja presión es de 85 y 90 por
ciento, respectivamente. Si la velocidad de flujo másico del refrigerante a través del ciclo inferior es
0.11 kg / s, determine (a) la velocidad de flujo másico del refrigerante a través del ciclo superior, (b) la
velocidad de extracción de calor del espacio refrigerado, y (c ) El COP de este frigorífico.
Consider the simple Linde–Hampson cycle shown in the figure. The gas is nitrogen and it is at 25 ◦C and 1
atm (101.325 kPa) at the compressor inlet, and the pressure of the gas is 20 MPa at the compressor outlet.
The compressor is reversible and isothermal, the heat exchanger has an effectiveness of 100% (i.e., the gas
leaving the liquid reservoir is heated in the heat exchanger to the temperature of the gas leaving the
compressor), the expansion valve is isenthalpic, and there is no heat leak to the cycle. Determine (a) the
refrigeration load per unit mass of the gas flowing through the compressor, (b) the COP, (c) the minimum
work input per unit mass of liquefaction, and (d) the exergy efficiency. Various properties of nitrogen in the
cycle are given as follows:
Considere el simple ciclo de Linde-Hampson que se muestra en la figura. El gas es nitrógeno y está a 25
° C y 1 atm (101.325 kPa) en la entrada del compresor, y la presión del gas es de 20 MPa en la salida del
compresor. El compresor es reversible e isotérmico, el intercambiador de calor tiene una efectividad
del 100% (es decir, el gas que abandona el depósito de líquido se calienta en el intercambiador de calor
hasta la temperatura del gas que sale del compresor), la válvula de expansión es una válvula
isenthalpic, y No hay fuga de calor al ciclo. Determine (a) la carga de refrigeración por unidad de masa
del gas que fluye a través del compresor, (b) la COP, (c) la entrada mínima de trabajo por unidad de
masa de licuefacción, y (d) la eficiencia de la exergía. Varias propiedades del nitrógeno en el ciclo se dan
a continuación:
Una bomba de calor industrial se utiliza para esterilización de leche, como se
muestra en la figura. Se calienta leche, que se encuentra a temperatura ambiente
T1, con agua caliente que circula por un circuito que pasa por el condensador de
una bomba de calor que funciona con R-123. Después de alcanzar la temperatura
de esterilización adecuada T2, la leche se enfría hasta una temperatura T3 de 5°C
con un fluido que circula por el evaporador de la bomba de calor. Supóngase que
este último fluido tiene las propiedades del agua exceptuada que se congela a -20 °
C. El flujo volumétrico de la leche es de 10 L/min. El diseño del sistema debe incluir
la elección de las presiones del refrigerante en el evaporador y condensador y los
flujos necesarios para en los circuitos calientes y fríos.
Desarrolle un trabajo de mínimo 15 páginas (sin contar página de presentación, índice y bibliografía),
donde desarrolle los siguientes temas
 Clasificación de los refrigerantes
 Prefijos y decodificación de los refrigerantes (incluyendo isómeros)
 Combinaciones de absorbente-refrigerantes
 Degradación de la capa de ozono (por refrigerantes) y el protocolo de Montreal
 Refrigerantes alternativos (amigables con el medio ambiente)

You might also like