二 .Technology instruction
1 .it adopts current advanced RO system ,the pure water conductivity will be less than 10us/cm,comforms
to the hygienic standard of GB17323-1998.
2.this system adopts American HYDRANUTICS company ESPA-4040,the rate of removed salt is
98%,recovery 50%-75%,and shapes the special character. The whole system can get rid of bacterial virus ,
heavy metallic irons. radioactive elements ,organic pollutant each is 99.99%,95%, 99%,95% ,the quality
of water sweet ,clean. Also get rid of poison harmful material in source water , such as four chlorination
carbons, benzenese, hydrocarbon, agrochemical, and lead, mercury ,chrome ...etc other radioactive
element all Be tested a limit the following.
▲system introduction
Technological process:
Raw water Raw water pump Quartz sand filter Active Carbon filter water softenern
pp filter RO system product pure water
Pp filter Muti-phases pump RO membrane
Quartz sand filter tank active carbon filter tank raw water pump
Water softener ion exchange
第 1 页 共 2 页
Technological introduction :
No.: Name Material origin Model Quantity Remark
1 Raw water pump China made BLC70/0.75kw 1set Voltage 220V power 0.75KW
flow meter 4-5M3/h working
2 pressure 0-2MPa
Quartz sand filter Fiber glass tank Ф450×1650 1 set Working pressure 0-2Mpa
Manual controller ,flux: 4M3/h
quartz sand 250kg
Active carbon filter Fiber glass tank Ф450×1650 1 pc Working pressure 0-2Mpa
Manual cntroller ,flux: 4M3/h
active carbon 125kg
Water softener Fiber glass tank Ф450×1650 1Pc Working pressure 0-2Mpa
Auto controller ,flux: 4M3/h
Resin : 100L
PP sediment filter Ф90×1000 5 piece Flux4-5M3/h
pressure ::0-2Mpa ,5pieces
RO system Automatic backwash ,manual
backwash, protected when
shortage water or high power
rated flux 2M3/H rated pressure:
0·1-1.0Mpa the rate of remove
salt 97%-99%
Recovery 50-75%
Housing membrane SUS304 1m 8pc
membrane HYDRANAUTIC ESPA-4040 8pcs
S USA
Multi-phases pump Hangzhou China CDL4-220 1set Voltage 380V power 4KW
Working pressure0·8-1.0Mpa
Flux :4-5M3/H
Conductivity monitor China made 1set
五.Main Character:
RO system recovery :50-65% RO system remove salt : 98-99% RO system flux :2M3/H
RO working voltage :380V RO system power: 4.75KW
Remarks :
Quartz sand should be change about 1 years . But you can take them out to wash it about 6 months /
Active carbon material should be change about 6 months .
PP filter can be change about 3-6 months .
RO membrane : should be change about 1-2 years .