You are on page 1of 9

unit_6.

masataka fukui Tu c k e r, S ( 2 0 0 3 ) , t h e s u n p a t h
ES_site and the passive princile of the pepys secondary school sources:
coates, p(2004), tutorial
interpretation of the results,
diagram at
h e a t h r o w, L o n d o n i n a p a c h e .
CIBSE design guide A the altitude
uel and
ordenance survey map(2001), the azimuth of the sunpaths
fukui, M(2003 and 2004), site visits i n t h e h e a t h r o w,
this figure represents the site layout of the pepys secondary school in relation to the wind and the sunlight chartered institution of building London, CIBSE(1988).
services engineering London(1990),
environmental design,
CIBSE guide A,CIBSE.

in the winter
the cold winds come mainly
from this direction
the northern facade with N
the mimium
openness is the wind
north-east and south-west shield.
pepy's youth
pepys estate centre

rd
ls
tal rd
1.004 es
ox h
d itc
b ow

post box
pepys park
public house
2-4 4-8 8-1212-18>16
Esso victoria
(m/s)
speed scale gasoline
stand
mean speed=3.46m/s cooled airs blow to each

gr
of the school bodies
A=4.47;k=1.80

ov
local cool fresh air in the summer.

e
percentile speed sainsbury's

st
(m/s)

re
et
5 1.03
10 1.03 rd
20 1.54 ay
ew
30 2.06 le
40 2.57
in the summer,
50 3.09 cooled airs access ev
el
60 3.60 to the school for the yn
70 4.12 st
natural ventilation re
et
80 5.14
90 6.17 and cooling
95 7.20 deptford park
wind rose in London(heathrow)
terrain category(iii) rd
n
o
o
key g
ra
1.004 is the percentage frequency d
of calms. inner circle with outer
circle means is drawn indicating the sunpath
5% frequency.
A and k are Weibull coefficients.
in summer
for instance,
wind speed at heathrow is 3.60m/s
for 60% of time.
mean speed in the same location
is 3.46m/s. in June 21 in June 21
at 3 pm(afternoon) at noon in June 21
altitude:46' altitude:63' at 9.am(morning)
azimuth:250' azimuth:180' altitude:46'
azimuth:110'

1/2500

the sunpath
in winter

in December 22
at noon
altitude:17'
in December 22 azimuth180'
in December 22
at 3 pm(afternoon) at 9 am
altitude:6' altitude:6'
azimuth:221' azimuth:139'

_cover in the environmental plan


unit_6. masataka fukui

analysis of the final result sources:


coates, p(2004), tutorai
interpretation of the results,
uel

_axonometric result showing the whole aspect.

community bodies

school bodies
AY pub victoria
th
co e AW
nn co
ec ur
to t_
r s th
pa e
ce am
en
ity exterior sport ground
sp
ac
e
AW
gas
o
& su line sta
AY

pers nd
tore
empty space

THE ABOVE RESULT represents that


1). formation of EXPLICIT clusters( shown by the colours) distributed within the sides.
2). definite state of the entry points HOLDING GOOD PROXIMITY TO the clustered bides

walking running 1/1750

cars cycling motor bike


walking running

normally closed
in the special occasions.

3) clusters with the SUITABLE relationship with the others based on the neighbouring rules
ADJACENT or AWAY(proper gaps in-between) from the peripheral buildings

clustered bodies

ADJACENT A W AY court as the amenity space and connector


space of either side
_interior spaces

office cluster

4 court sport

entrance and
reception

interior activity
clusters

community bodies
bridge

school bodies

key stage_3

6th form

key stage_4
>>axonometric external spaces of the school bodies unit_6.masataka fukui

they are characterized by the permeatable spaces of the school bodies which intend to have the high portions
of fitness to the spatial quality criteria such as environmental voids, accessibility as well as views.
the white paints of the roofs and glass-clad walls also characterize the sawbuzz bodies

_east view

1/2400
unit_6_masataka fukui

_view s2

s3

s2

_1st floor
_indication 1/355
_view s3
unit6_masataka fukui
sources:
saint-gobain.glass guide
(2000)

_interior spaces with the physical model view3

view4

view5

view2

view1 view1. skylight and lumitop toughened transparent glasses. in reality those glasses increase the illumination level more than
that of the above.

scale of the original model:1/20

1/3340

_indication

environmentally, skylight system is to provide 2 to 3 times more the daylight than normal
facade glazing one.
it appears to be good for the deep interior spaces like that of above for it to take
the sufficient illumination levels which reduce the dependence of the artificial lighting in most
of the days.
Furthermore, 3m ceiling-to-floor frameless transparent lumitop toughened glasses on the walls contribute to
increase the illumination level.
the maximized amount of the sunlight is reflected by those glasses to the ceiling and walls painted
view2. greeny colour on the floor will cause restful or
to white(very reflective).- quietant effect for the staffs and pupils inside(good
psychological
and spatial effect) and the skylight above is
composed of the glass beams and glass panes
(monocoque structural glass skylight system)

view4. view5.
view3.
views from a large cross-sectional parts looking at the long transparent toughened glasses with the openable windows from the bellow to above

You might also like