75 475 350
BEAM
4. The structural drawings shall be read in conjunction
3 600 1200
3 5. with architectural drawings. Any discrepancies, if any,
1200 1200 1200 1200 1200 600 shall be reported to the site engineer.
495
A' 6. Contractor shall be responsible for checking field
dimensions and site conditions.
1350
1350
7. Concrete grade for column shall be equivalent to
M20 & for other members (foundation, beam, slab etc.)
Y Y equivalent to M20.
675 75
A
8. Lap length shall be not less than development length
675
'Ld'.
350
350
9. Development length (Ld) shall be:
995
TIE BEAM
For all members
A
995
10. Clear cover shall be:
25mm plaster thickness
c = 25mm for beam
100 500 500 100
c = 40mm for column
c = 50mm for foundation
300
300
c = 15mm for slab
11. Distance of closed stirrups in beam shall be
300 300 as mentioned in the drawing otherwise 2D from
SECTIONAL PLAN AT B-B
495
face support (where D is total depth of beam)
1 1 12. End ties (from face of support) in column shall be
upto distance 450mm.
13. Lap is to be provided in column after distance H/4 from
300 face of support where H= clear height of column.
16300 60 60 14. Unless otherwise indicated all construction joints shall
75
be roughened joints with min. amplitude of 5mm.
15. Reinforcing steel shall be new hot rolled deformed
A B X C D E bars
conforming to IS, 1786-1979 or IS 1139: 1966 and
DETAIL AT A AND A' shall have a min. yield 415 N/mm2.
SLAB PLAN 16. Plumbing slots, holes around pipes, ducts or other
items
which pass through concrete slab or wall shall be filled
A 3600 B 4000 B' C 3300 D E and patched to the same depth as slab or wall.
* Note: Structure design is limited to
1670 1785 1395 1885 single storey only with no storey
extension provision.