Construction of Elevated Corridor by integrating Ejipura Main Road – Inner Ring Road Junction, Sony World Junction, Sony

World Junction and Kendriya Sadana Junction along 100 ft. Inner Ring Road, Koramangala,Bangalore

SIMPLEX INFRASTRUCTURES LIMITED

DRAWING REGISTER AS ON 11-05-2018

For Approval /
Sl.No. TYPE Drawing No Description of Drawing Revision No. Simplex Letter No Infra letter no PMC to BBMP BBMP to SIL Remarks
Submitted to Client

A TOPOGRAPHICAL SURVEY DETAILS

TOPOGRAPHICAL SURVEY DETAILS


1 DWG AL/SIMPLEX-EJIPURA/01/2017 R0 Ref No.; 012/CL/BBMPSONY/001/VOL.1/19 08/11/2017 IS/BBMP-SW/PMC/1712/ 2017-18/12 25/11/2017
DRAWING (Sheet 1 of 3)

TOPOGRAPHICAL SURVEY DETAILS


2 DWG AL/SIMPLEX-EJIPURA/01/2017 R0 Ref No.; 012/CL/BBMPSONY/001/VOL.1/19 08/11/2017 IS/BBMP-SW/PMC/1712/ 2017-18/12 25/11/2017
DRAWING (Sheet 2 of 3)

TOPOGRAPHICAL SURVEY DETAILS


3 DWG AL/SIMPLEX-EJIPURA/01/2017 R0 Ref No.; 012/CL/BBMPSONY/001/VOL.1/19 08/11/2017 IS/BBMP-SW/PMC/1712/ 2017-18/12 25/11/2017
DRAWING (Sheet 3 of 3)

B CENTER LINE COORDINATES

PIER & PILE CO-ORDINATES (FOR P9-P25, P25-


1 DWG NC/BBMP/SIMPLEX/SONY/SD-06A R0 Ref No.; 012/CL/BBMPSONY/001/VOL.1/43 14/12/2017 IS/BBMP-SW/PMC/1712/ 2017-18/12 25/11/2017
P32, P33-P34)

C GENERAL ARRANGEMENT

1 DWG NC/SIMPLEX/EJIPURA/GL-01 GRADE LEVEL PLAN R0 Ref No.; 012/CL/BBMPSONY/001/VOL.1/52, 73 12/03/2018 IS/BBMP-SW/PMC/1712/ 2017-18/36 24/04/2018

D PLAN AND PROFILE / CROSS SECTION

R0 Ref No.; 012/CL/BBMPSONY/001/VOL.1/14 11/10/2017 COMMENTED

R1 Ref No.; 012/CL/BBMPSONY/001/VOL.1/37 30/11/2017 COMMENTED


1 DWG NC/SIMPLEX/EJIPURA/AL-P&P-01(SH-1) PLAN and PROFILE
R2 Ref No.; 012/CL/BBMPSONY/001/VOL.1/52 12/03/2018 COMMENTED

R3 Ref No.; 012/CL/BBMPSONY/001/VOL.1/73 21/04/2018 IS/BBMP-SW/PMC/1712/ 2017-18/36 24/04/2018


For Approval /
Sl.No. TYPE Drawing No Description of Drawing Revision No. Simplex Letter No Infra letter no PMC to BBMP BBMP to SIL Remarks
Submitted to Client

R0 Ref No.; 012/CL/BBMPSONY/001/VOL.1/14 11/10/2017 COMMENTED

R1 Ref No.; 012/CL/BBMPSONY/001/VOL.1/37 30/11/2017 COMMENTED


2 DWG NC/SIMPLEX/EJIPURA/AL-P&P-01(SH-2) PLAN and PROFILE
R2 Ref No.; 012/CL/BBMPSONY/001/VOL.1/52 12/03/2018 COMMENTED

R3 Ref No.; 012/CL/BBMPSONY/001/VOL.1/73 21/04/2018 IS/BBMP-SW/PMC/1712/ 2017-18/36 24/04/2018

R0 Ref No.; 012/CL/BBMPSONY/001/VOL.1/14 11/10/2017 COMMENTED

3 DWG NC/SIMPLEX/EJIPURA/AL-CS-01 TYPICAL CROSS SECTION R1 Ref No.; 012/CL/BBMPSONY/001/VOL.1/39 08/12/2017 COMMENTED

R2 Ref No.; 012/CL/BBMPSONY/001/VOL.1/52 12/03/2018 IS/BBMP-SW/PMC/1712/ 2017-18/36 24/04/2018

R0 Ref No.; 012/CL/BBMPSONY/001/VOL.1/14 11/10/2017 COMMENTED

NC/SIMPLEX/EJIPURA/AL-P&P-01(SH- PLAN and PROFILE (UP RAMP & DOWN RAMP


4 DWG R1 Ref No.; 012/CL/BBMPSONY/001/VOL.1/52 12/03/2018 COMMENTED
03) and additional UP RAMP)

R2 Ref No.; 012/CL/BBMPSONY/001/VOL.1/73 21/04/2018 IS/BBMP-SW/PMC/1712/ 2017-18/36 24/04/2018

5 DWG AL/SIMPLEX-EJIPURA/01/2017 CROSS SECTIONAL DRAWING (Sheet 1 of 11) R0 Ref No.; 012/CL/BBMPSONY/001/VOL.1/19 08/11/2017 IS/BBMP-SW/PMC/1712/ 2017-18/12 25/11/2017

6 DWG AL/SIMPLEX-EJIPURA/01/2017 CROSS SECTIONAL DRAWING (Sheet 2 of 11) R0 Ref No.; 012/CL/BBMPSONY/001/VOL.1/19 08/11/2017 IS/BBMP-SW/PMC/1712/ 2017-18/12 25/11/2017

7 DWG AL/SIMPLEX-EJIPURA/01/2017 CROSS SECTIONAL DRAWING (Sheet 3 of 11) R0 Ref No.; 012/CL/BBMPSONY/001/VOL.1/19 08/11/2017 IS/BBMP-SW/PMC/1712/ 2017-18/12 25/11/2017

8 DWG AL/SIMPLEX-EJIPURA/01/2017 CROSS SECTIONAL DRAWING (Sheet 4 of 11) R0 Ref No.; 012/CL/BBMPSONY/001/VOL.1/19 08/11/2017 IS/BBMP-SW/PMC/1712/ 2017-18/12 25/11/2017

9 DWG AL/SIMPLEX-EJIPURA/01/2017 CROSS SECTIONAL DRAWING (Sheet 5 of 11) R0 Ref No.; 012/CL/BBMPSONY/001/VOL.1/19 08/11/2017 IS/BBMP-SW/PMC/1712/ 2017-18/12 25/11/2017

10 DWG AL/SIMPLEX-EJIPURA/01/2017 CROSS SECTIONAL DRAWING (Sheet 6 of 11) R0 Ref No.; 012/CL/BBMPSONY/001/VOL.1/19 08/11/2017 IS/BBMP-SW/PMC/1712/ 2017-18/12 25/11/2017

11 DWG AL/SIMPLEX-EJIPURA/01/2017 CROSS SECTIONAL DRAWING (Sheet 7 of 11) R0 Ref No.; 012/CL/BBMPSONY/001/VOL.1/19 08/11/2017 IS/BBMP-SW/PMC/1712/ 2017-18/12 25/11/2017

12 DWG AL/SIMPLEX-EJIPURA/01/2017 CROSS SECTIONAL DRAWING (Sheet 8 of 11) R0 Ref No.; 012/CL/BBMPSONY/001/VOL.1/19 08/11/2017 IS/BBMP-SW/PMC/1712/ 2017-18/12 25/11/2017
For Approval /
Sl.No. TYPE Drawing No Description of Drawing Revision No. Simplex Letter No Infra letter no PMC to BBMP BBMP to SIL Remarks
Submitted to Client

13 DWG AL/SIMPLEX-EJIPURA/01/2017 CROSS SECTIONAL DRAWING (Sheet 9 of 11) R0 Ref No.; 012/CL/BBMPSONY/001/VOL.1/19 08/11/2017 IS/BBMP-SW/PMC/1712/ 2017-18/12 25/11/2017

14 DWG AL/SIMPLEX-EJIPURA/01/2017 CROSS SECTIONAL DRAWING (Sheet 10 of 11) R0 Ref No.; 012/CL/BBMPSONY/001/VOL.1/19 08/11/2017 IS/BBMP-SW/PMC/1712/ 2017-18/12 25/11/2017

15 DWG AL/SIMPLEX-EJIPURA/01/2017 CROSS SECTIONAL DRAWING (Sheet 11 of 11) R0 Ref No.; 012/CL/BBMPSONY/001/VOL.1/19 08/11/2017 IS/BBMP-SW/PMC/1712/ 2017-18/12 25/11/2017

F PILE, PILE CAP, PIER & PIERCAPS

SUB STRUCTURE DETAILS (P9 - P16, P18- P25 R0 Ref No.; 012/CL/BBMPSONY/001/VOL.1/43 14/12/2017
1 DESIGN NC/BBMP/SIL/SONY/SR-11
& P33 - P34)
R1 Ref No.; 012/CL/BBMPSONY/001/VOL.1/68 16/04/2018

R0 Ref No.; 012/CL/BBMPSONY/001/VOL.1/43 14/12/2017 COMMENTED


PIER SUB STRUCTURE DETAILS (P9 TO P16,
2 DWG NC/BBMP/SIMPLEX/SD-12 P18 TO P25, P33 & P34) STRAIGHT SPANS
(CONCRETE DIMENSIONS)
R1 Ref No.; 012/CL/BBMPSONY/001/VOL.1/68 16/04/2018 UNDER REVIEW

R0 Ref No.; 012/CL/BBMPSONY/001/VOL.1/43 14/12/2017 COMMENTED


PIER SUB STRUCTURE DETAILS (P9 TO P16,
3 DWG NC/BBMP/SIMPLEX/SD-13 P18 TO P25, P33 & P34) STRAIGHT SPANS
(REINFORCEMENT DIMENSIONS)
R1 Ref No.; 012/CL/BBMPSONY/001/VOL.1/68 16/04/2018 UNDER REVIEW

R0 Ref No.; 012/CL/BBMPSONY/001/VOL.1/43 14/12/2017


4 DESIGN NC/BBMP/SIL/SONY/SR-12 SUB STRUCTURE DETAILS (P26, P28 - P32)
R1 Ref No.; 012/CL/BBMPSONY/001/VOL.1/68 16/04/2018

R0 Ref No.; 012/CL/BBMPSONY/001/VOL.1/43 14/12/2017 COMMENTED


PIER SUB STRUCTURE DETAILS P26, P28, P29
5 DWG NC/BBMP/SIMPLEX/SD-14 TO P32 (CURVED SPAN) (CONCRETE
DIMENSIONS)
R1 Ref No.; 012/CL/BBMPSONY/001/VOL.1/68 16/04/2018 UNDER REVIEW

R0 Ref No.; 012/CL/BBMPSONY/001/VOL.1/43 14/12/2017 COMMENTED


PIER SUB STRUCTURE DETAILS P26, P28, P29
6 DWG NC/BBMP/SIMPLEX/SD-15 TO P32 (CURVED SPAN) (REINFORCEMENT
DIMENSIONS)
R1 Ref No.; 012/CL/BBMPSONY/001/VOL.1/68 16/04/2018 UNDER REVIEW

R0 Ref No.; 012/CL/BBMPSONY/001/VOL.1/9 14/09/2017


7 DESIGN NC/BBMP/SIL/SONY/SR-02 TEST PILE DETAILS FOR INITIAL LOAD TEST
R1 Ref No.; 012/CL/BBMPSONY/001/VOL.1/13 09/10/2017

R0 Ref No.; 012/CL/BBMPSONY/001/VOL.1/9 14/09/2017 COMMENTED


8 DWG NC/SIMPLEX/EJIPURA/TEST PILE TEST PILE DETAILS FOR INITIAL LOAD TEST
R1 Ref No.; 012/CL/BBMPSONY/001/VOL.1/13 09/10/2017 IS/BBMP-SW/PMC/1712/ 2017-18/14 12/04/2017

Design calculations for initial vertical pile testing


9 DESIGN 02/DD/C3191/PLT/DOC/001 R0 Ref No.; 012/CL/BBMPSONY/001/VOL.1/18 07/11/2017
arrangement for 1200 dia. Test pile fr BH-01
For Approval /
Sl.No. TYPE Drawing No Description of Drawing Revision No. Simplex Letter No Infra letter no PMC to BBMP BBMP to SIL Remarks
Submitted to Client

Arrangements details for initial vertical pile test near


10 DWG 02/DD/C3191/PLT/001 R0 Ref No.; 012/CL/BBMPSONY/001/VOL.1/18 07/11/2017 IS/BBMP-SW/PMC/1712/ 2017-18/13 25/11/2017
BH-01( test load 1300 MT) Sheet 01 of 02

Arrangements details for initial vertical pile test near


11 DWG 02/DD/C3191/PLT/001 R0 Ref No.; 012/CL/BBMPSONY/001/VOL.1/18 07/11/2017 IS/BBMP-SW/PMC/1712/ 2017-18/13 25/11/2017
BH-01( test load 1300 MT) Sheet 02 of 02

TEST PILE DETAILS FOR INITIAL LOAD


12 DESIGN NC/BBMP/SIL/SONY/SR-03 R0 Ref No.; 012/CL/BBMPSONY/001/VOL.1/31 18/11/2017
TEST(Near Ejipura junction)
TEST PILE DETAILS FOR INITIAL LOAD
13 DWG NC/SIMPLEX/EJIPURA/TEST PILE R0 Ref No.; 012/CL/BBMPSONY/001/VOL.1/31 18/11/2017 IS/BBMP-SW/PMC/1712/ 2017-18/14 12/04/2017
TEST(Near Ejipura junction)

Design calculations for initial vertical pile testing R0 Ref No.; 012/CL/BBMPSONY/001/VOL.1/35 28/11/2017
14 DESIGN 02/DD/C3191/PLT/DOC/002
arrangement for 1200 dia. Test pile-02
R1 Ref No.; 012/CL/BBMPSONY/001/VOL.1/41 13/12/2017

R0 Ref No.; 012/CL/BBMPSONY/001/VOL.1/35 28/11/2017 COMMENTED


Arrangements details for initial vertical pile test for
15 DWG 02/DD/C3191/PLT/002
BH-20( test load 1300 MT) Sheet 01 of 02
R1 Ref No.; 012/CL/BBMPSONY/001/VOL.1/41 13/12/2017 IS/BBMP-SW/PMC/1712/ 2017-18/16 15/12/2017

R0 Ref No.; 012/CL/BBMPSONY/001/VOL.1/35 28/11/2017 COMMENTED


Arrangements details for initial vertical pile test for
16 DWG 02/DD/C3191/PLT/002
BH-20( test load 1300 MT) Sheet 02 of 02
R1 Ref No.; 012/CL/BBMPSONY/001/VOL.1/41 13/12/2017 IS/BBMP-SW/PMC/1712/ 2017-18/16 15/12/2017

Design calculations for routine pile test for 1200 dia.


17 DESIGN 02/DD/C3191/RPLT/DOC/001 R0 Ref No.; 012/CL/BBMPSONY/001/VOL.1/51 09/02/2018
Pile P16/3
Arrangements details for routine pile load test of
18 DWG 02/DD/C3191/RPLT/001 R0 Ref No.; 012/CL/BBMPSONY/001/VOL.1/51 09/02/2018 IS/BBMP-SW/PMC/1712/ 2017-18/27 28/02/2018
1200mm dia. Pile P16/3 Sheet 01 of 02

Arrangements details for routine pile load test of


19 DWG 02/DD/C3191/RPLT/001 R0 Ref No.; 012/CL/BBMPSONY/001/VOL.1/51 09/02/2018 IS/BBMP-SW/PMC/1712/ 2017-18/27 28/02/2018
1200mm dia. Pile P16/3 Sheet 02 of 02

20 DESIGN NC/BBMP/SIL/SONY/SR-37 Sub structure Detail (P-27) (Open foundation) R0 Ref No.; 012/CL/BBMPSONY/001/VOL.1/68 16/04/2018

P-27 Pier Sub sturcture details. (Concrete


21 DWG NC/BBMP/SIMPLEX/SONY/SD-27 R0 Ref No.; 012/CL/BBMPSONY/001/VOL.1/68 16/04/2018 UNDER REVIEW
Dimensions))

P-27 Pier Sub sturcture details. (Reinforcement


22 DWG NC/BBMP/SIMPLEX/SONY/SD-28 R0 Ref No.; 012/CL/BBMPSONY/001/VOL.1/68 16/04/2018 UNDER REVIEW
Details)

23 DESIGN NC/BBMP/SIL/SONY/SR-38 Sub structure Detail (P-17) (Open foundation) R0 Ref No.; 012/CL/BBMPSONY/001/VOL.1/68 16/04/2018

P-17 Pier Sub sturcture details. (Concrete


24 DWG NC/BBMP/SIMPLEX/SONY/SD-61 R0 Ref No.; 012/CL/BBMPSONY/001/VOL.1/68 16/04/2018 UNDER REVIEW
Dimensions))

P-17 Pier Sub sturcture details. (Reinforcement


25 DWG NC/BBMP/SIMPLEX/SONY/SD-62 R0 Ref No.; 012/CL/BBMPSONY/001/VOL.1/68 16/04/2018 UNDER REVIEW
Details)

26 DESIGN NC/BBMP/SIL/SONY/SR-16 Sub Stucture Details (P1 and P65) R0 Ref No.; 012/CL/BBMPSONY/001/VOL.1/68 16/04/2018

Pier Sub structure Details (P1 & P65) (Concrete


27 DWG NC/BBMP/SIMPLEX/SONY/SD-29 R0 Ref No.; 012/CL/BBMPSONY/001/VOL.1/68 16/04/2018 UNDER REVIEW
Dimensions)
For Approval /
Sl.No. TYPE Drawing No Description of Drawing Revision No. Simplex Letter No Infra letter no PMC to BBMP BBMP to SIL Remarks
Submitted to Client

Pier Sub structure Details (P1 & P65)


28 DWG NC/BBMP/SIMPLEX/SONY/SD-30 R0 Ref No.; 012/CL/BBMPSONY/001/VOL.1/68 16/04/2018 UNDER REVIEW
(Reinforcement Details)

29 DESIGN NC/BBMP/SIL/SONY/SR-14 Sub Structure Details (P43-P53) R0 Ref No.; 012/CL/BBMPSONY/001/VOL.1/78 05/05/2018

Pier Sub structure Details (P43-P53) Curved Span


30 DWG NC/BBMP/SIMPLEX/SONY/SD-21 R0 Ref No.; 012/CL/BBMPSONY/001/VOL.1/78 05/05/2018 YET TO RECEIVE
(Concrete Dimensions)

Pier Sub structure Details (P43-P53) Curved Span


31 DWG NC/BBMP/SIMPLEX/SONY/SD-22 R0 Ref No.; 012/CL/BBMPSONY/001/VOL.1/78 05/05/2018 YET TO RECEIVE
(Reinforcement Details)

32 DESIGN NC/BBMP/SIL/SONY/SR-13 Sub Structure Details (P36-P40, P54-P61) R0 Ref No.; 012/CL/BBMPSONY/001/VOL.1/78 05/05/2018

Pier Sub structure Details (P36 to P40, P54 toP61)


33 DWG NC/BBMP/SIMPLEX/SONY/SD-19 R0 Ref No.; 012/CL/BBMPSONY/001/VOL.1/78 05/05/2018 YET TO RECEIVE
Straight Span (Concrete Dimensions)

Pier Sub structure Details (P36 to P40, P54 to P61)


34 DWG NC/BBMP/SIMPLEX/SONY/SD-20 R0 Ref No.; 012/CL/BBMPSONY/001/VOL.1/78 05/05/2018 YET TO RECEIVE
Straight Span (Reinforcement Details)

G PRECAST SEGMENTAL

SUPER STRUCTURE DETAILS (CONCRETE


1 DWG NC/BBMP/SIMPLEX/SONY/SD-37 R0 Ref No.; 012/CL/BBMPSONY/001/VOL.1/43 14/12/2017 UNDER REVIEW
DIMENSIONS 33.4m SPAN)
For Approval /
Sl.No. TYPE Drawing No Description of Drawing Revision No. Simplex Letter No Infra letter no PMC to BBMP BBMP to SIL Remarks
Submitted to Client