Professional Documents
Culture Documents
Design Calculations
Client: F3 Architects
Project: 23 Denewood Road
Title: Façade Retention and Temporary Propping for Basement
Cal Ref: 17-142-01
Prepared: R Jose BSc(Hons) ACGI CEng MIStructE
Checked:
Reference Documents:
Design Brief:
To design for submission to planning authority a façade retention scheme to a 2-storey high wall front of property.
Key Assumptions:
Summary:
Use 152UC23 rakers and post with twin 150x75 PFC’s back to back walers in front of façade. 15ø ties with waler
nuts to tie walers to façade with 150x75 PFC flat back on wall. Stability to be provided by C20/25 concrete
kentledge of 1.5m deep buried 0.5m to ground.
Significant Residual Risks:
All proprietary equipment to be used in accordance with manufacturer’s recommendations and to be installed by
competent persons.
INDEX
Page
Brief 01
Loadings 01
Masonry Wall Assessment 04
Design of Walers 05
Design of Tie Rods/Packers 05
Design of Rakers 10
Design of Kentledge 14
Design of Baseplate Connections 16
Design of Raker/Post Connection 23
Design of Post 28
Check Foundation 29
Project Job no.
23 Denewood Road - Facade Retention 17-142-01
Calcs for Start page no./Revision
Contractors Deign Servces F3 Architects 6
6 Millers House Roydon Rd
Calcs by Calcs date Checked by Checked date Approved by Approved date
Stanstead SG12 8HN
RJ 24/05/2017
01920 877077
0.0
mm 700 3800 700
A 1 B 2 C 3 D
14.742
14.7
mm 700 3800 700
A 1 B 2 C 3 D
0.0
-6.6
-17.955
-18.0
mm 700 3800 700
A 1 B 2 C 3 D
Support conditions
Support A Vertically free
Rotationally free
Support B Vertically restrained
Rotationally free
Support C Vertically restrained
Rotationally free
Support D Vertically free
Rotationally free
Applied loading
Beam loads Notional - Permanent full UDL 0.7 kN/m
Wind - Variable full UDL 5.67 kN/m
Load combinations
Load combination 1 Support A Permanent 1.35
Variable 1.50
Span 1 Permanent 1.35
Variable 1.50
Project Job no.
23 Denewood Road - Facade Retention 17-142-01
Calcs for Start page no./Revision
Contractors Deign Servces F3 Architects 7
6 Millers House Roydon Rd
Calcs by Calcs date Checked by Checked date Approved by Approved date
Stanstead SG12 8HN
RJ 24/05/2017
01920 877077
Analysis results
Maximum moment; Mmax = 14.7 kNm; Mmin = -2.3 kNm
Maximum moment span 1; Ms1_max = 0 kNm; Ms1_min = -2.3 kNm
Maximum moment span 2; Ms2_max = 14.7 kNm; Ms2_min = -2.3 kNm
Maximum moment span 3; Ms3_max = 0 kNm; Ms3_min = -2.3 kNm
Maximum shear; Vmax = 18 kN; Vmin = -18 kN
Maximum shear span 1; Vs1_max = 0 kN; Vs1_min = -6.6 kN
Maximum shear span 2; Vs2_max = 18 kN; Vs2_min = -18 kN
Maximum shear span 3; Vs3_max = 6.6 kN; Vs3_min = 0 kN
Deflection; max = 7.1 mm; min = 3.9 mm
Deflection span 1; s1_max = 0 mm; s1_min = 3.9 mm
Deflection span 2; s2_max = 7.1 mm; s2_min = 0 mm
Deflection span 3; s3_max = 0 mm; s3_min = 3.9 mm
Maximum reaction at support A; RA_max = 0 kN; RA_min = 0 kN
Maximum reaction at support B; RB_max = 24.6 kN; RB_min = 24.6 kN
Unfactored permanent load reaction at support B; RB_Permanent = 1.8 kN
Unfactored variable load reaction at support B; RB_Variable = 14.7 kN
Maximum reaction at support C; RC_max = 24.6 kN; RC_min = 24.6 kN
Unfactored permanent load reaction at support C; RC_Permanent = 1.8 kN
Unfactored variable load reaction at support C; RC_Variable = 14.7 kN
Maximum reaction at support D; RD_max = 0 kN; RD_min = 0 kN
Section details
Section type; PFC 150x75x18 (BS4-1)
Steel grade; S275
EN 10025-2:2004 - Hot rolled products of structural steels
Nominal thickness of element; t = max(tf, tw) = 10.0 mm
Nominal yield strength; fy = 275 N/mm2
Nominal ultimate tensile strength; fu = 410 N/mm2
Modulus of elasticity; E = 210000 N/mm2
Project Job no.
23 Denewood Road - Facade Retention 17-142-01
Calcs for Start page no./Revision
Contractors Deign Servces F3 Architects 8
6 Millers House Roydon Rd
Calcs by Calcs date Checked by Checked date Approved by Approved date
Stanstead SG12 8HN
RJ 24/05/2017
01920 877077
10
150
5.5
10
75
Lateral restraint
Span 1 has full lateral restraint
Span 2 has full lateral restraint
Span 3 has full lateral restraint
Cantilever tip is free
Cantilever support is continuous with lateral and torsional restraint
Effective length factors
Effective length factor in major axis; Ky = 1.000
Effective length factor in minor axis; Kz = 1.000
Effective length factor for torsion; KLT.A = 1.000;
KLT.B = 1.000;
KLT.C = 1.000;
KLT.D = 1.000;
Classification of cross sections - Section 5.5
= [235 N/mm2 / fy] = 0.92
Design section 1
Section details
Section type UC 152x152x23 (BS4-1)
Steel grade - EN 10025-2:2004 S275
Nominal thickness of element tnom = max(tf, tw) = 6.8 mm
Nominal yield strength fy = 275 N/mm2
Nominal ultimate tensile strength fu = 410 N/mm2
Modulus of elasticity E = 210000 N/mm2
UC 152x152x23 (BS4-1)
Section depth, h, 152.4 mm
Section breadth, b, 152.2 mm
Mass of section, Mass, 23 kg/m
Flange thickness, tf, 6.8 mm
Web thickness, tw, 5.8 mm
Root radius, r, 7.6 mm
Area of section, A, 2925 mm2
Radius of gyration about y-axis, iy, 65.372 mm
Radius of gyration about z-axis, iz, 36.979 mm
Elastic section modulus about y-axis, W el.y, 164016 mm3
Elastic section modulus about z-axis, W el.z, 52552 mm3
5.8 Plastic section modulus about y-axis, W pl.y, 181982 mm3
Plastic section modulus about z-axis, W pl.z, 80156 mm3
Second moment of area about y-axis, Iy, 12498039 mm4
Second moment of area about z-axis, Iz, 3999186 mm4
152.2
Analysis results
Design axial compression force NEd = 92 kN
Restraint spacing
Major axis lateral restraint Ly = 4300 mm
Minor axis lateral restraint Lz = 4300 mm
Torsional restraint LT = 4300 mm
Classification of cross sections - Section 5.5
= [235 N/mm2 / fy] = 0.92
Specifier's comments:
1 Input data
Anchor type and size: HIT-HY 200-A + HIT-Z M16
Effective embedment depth: hef,opti = 108 mm (hef,limit = 192 mm)
Material: DIN EN ISO 4042
Approval No.: ETA 12/0006
Issued I Valid: 18/08/2016 | -
Proof: Design method ETAG BOND (EOTA TR 029)
Stand-off installation: eb = 0 mm (no stand-off); t = 12 mm
Baseplate: lx x ly x t = 350 mm x 350 mm x 12 mm; (Recommended plate thickness: not calculated
Profile: Advance UKC; (L x W x T x FT) = 152 mm x 152 mm x 7 mm x 7 mm
Base material: cracked concrete, C20/25, fc,cube = 25.00 N/mm2; h = 1500 mm, Temp. short/long: 0/0 °C
Installation: hammer drilled hole, Installation condition: Dry
Reinforcement: No reinforcement or Reinforcement spacing >= 150 mm (any Ø) or >= 100 mm (Ø <= 10 mm)
no longitudinal edge reinforcement
Input data and results must be checked for agreement with the existing conditions and for plausibility!
PROFIS Anchor ( c ) 2003-2009 Hilti AG, FL-9494 Schaan Hilti is a registered Trademark of Hilti AG, Schaan
www.hilti.co.uk Profis Anchor 2.7.3
Company: CDS Page: 18
Specifier: RJ Project: 23 Denewood Road
Address: Fastening Point: Baseplate
Phone I Fax: | Date: 25/05/2017
E-Mail:
Input data and results must be checked for agreement with the existing conditions and for plausibility!
PROFIS Anchor ( c ) 2003-2009 Hilti AG, FL-9494 Schaan Hilti is a registered Trademark of Hilti AG, Schaan
www.hilti.co.uk Profis Anchor 2.7.3
Company: CDS Page: 19
Specifier: RJ Project: 23 Denewood Road
Address: Fastening Point: Baseplate
Phone I Fax: | Date: 25/05/2017
E-Mail:
Comments: Tension displacements are valid with half of the required installation torque moment for uncracked concrete! Shear displacements
are valid without friction between the concrete and the baseplate! The gap due to the drilled hole and clearance hole tolerances are not
included in this calculation!
The acceptable anchor displacements depend on the fastened construction and must be defined by the designer!
Input data and results must be checked for agreement with the existing conditions and for plausibility!
PROFIS Anchor ( c ) 2003-2009 Hilti AG, FL-9494 Schaan Hilti is a registered Trademark of Hilti AG, Schaan
www.hilti.co.uk Profis Anchor 2.7.3
Company: CDS Page: 20
Specifier: RJ Project: 23 Denewood Road
Address: Fastening Point: Baseplate
Phone I Fax: | Date: 25/05/2017
E-Mail:
7 Warnings
• The anchor design methods in PROFIS Anchor require rigid anchor plates per current regulations (ETAG 001/Annex C, EOTA TR029, etc.).
This means load re-distribution on the anchors due to elastic deformations of the anchor plate are not considered - the anchor plate is
assumed to be sufficiently stiff, in order not to be deformed when subjected to the design loading. PROFIS Anchor calculates the minimum
required anchor plate thickness with FEM to limit the stress of the anchor plate based on the assumptions explained above. The proof if the
rigid base plate assumption is valid is not carried out by PROFIS Anchor. Input data and results must be checked for agreement with the
existing conditions and for plausibility!
• Checking the transfer of loads into the base material is required in accordance with EOTA TR 029, Section 7!
• The design is only valid if the clearance hole in the fixture is not larger than the value given in Table 4.1 of EOTA TR029! For larger
diameters of the clearance hole see Chapter 1.1. of EOTA TR029!
• The accessory list in this report is for the information of the user only. In any case, the instructions for use provided with the product have to
be followed to ensure a proper installation.
• Characteristic bond resistances depend on short- and long-term temperatures.
• Edge reinforcement is not required to avoid splitting failure
Input data and results must be checked for agreement with the existing conditions and for plausibility!
PROFIS Anchor ( c ) 2003-2009 Hilti AG, FL-9494 Schaan Hilti is a registered Trademark of Hilti AG, Schaan
www.hilti.co.uk Profis Anchor 2.7.3
Company: CDS Page: 21
Specifier: RJ Project: 23 Denewood Road
Address: Fastening Point: Baseplate
Phone I Fax: | Date: 25/05/2017
E-Mail:
8 Installation data
Baseplate, steel: - Anchor type and size: HIT-HY 200-A + HIT-Z M16
Profile: Advance UKC; 152 x 152 x 7 x 7 mm Installation torque: 0.080 kNm
Hole diameter in the fixture: df = 18 mm Hole diameter in the base material: 18 mm
Plate thickness (input): 12 mm Hole depth in the base material: 172 mm
Recommended plate thickness: not calculated Minimum thickness of the base material: 208 mm
Drilling method: Hammer drilled
Cleaning: No cleaning of the drilled hole is required
175 175
45
3 4
175
260
x
175
1 2
45
45 260 45
Input data and results must be checked for agreement with the existing conditions and for plausibility!
PROFIS Anchor ( c ) 2003-2009 Hilti AG, FL-9494 Schaan Hilti is a registered Trademark of Hilti AG, Schaan
www.hilti.co.uk Profis Anchor 2.7.3
Company: CDS Page: 22
Specifier: RJ Project: 23 Denewood Road
Address: Fastening Point: Baseplate
Phone I Fax: | Date: 25/05/2017
E-Mail:
Input data and results must be checked for agreement with the existing conditions and for plausibility!
PROFIS Anchor ( c ) 2003-2009 Hilti AG, FL-9494 Schaan Hilti is a registered Trademark of Hilti AG, Schaan
Project Job Ref.
Connection Details
number of bolt rows nbolts = 2
Bolt pitch pbolts = 400 mm
Bolt gauge gbolts = 90 mm
End plate end distance (top & bottom) e1endplate = 45 mm
End plate edge distance e2endplate = (dendplate - gbolts) / 2 = 31 mm
End plate length lendplate = pbolts (nbolts-1)+2 e1endplate = 490 mm
Weld leg length sweld = 6 mm
Beam end reaction Q = 85.9 kN
Check 1 - Essential detailing requirements
End plate thickness tendplate = 10 mm PASS
Bolt gauge gbolts = 90 mm PASS
End plate Length lendplate = 490 mm
End plate length for torsional requirements : PASS
Check 2 - Shear capacity of bolt group connecting end plate to supporting column
Shear capacity of top pair of bolts
pbsendplate = 460 N/mm2
Psbolts1 = min(Psbolts, 0.5 e1endplate tendplate pbsendplate) = 58.9 kN
Shear capacity of other bolts
Psbolts = 58.9 kN
Shear capacity of bolt group - sum of bolt capacities
Psboltssum = 2 Psbolts1 + 2 (nbolts - 1) Psbolts = 235.5 kN
Shear on bolt group Q = 85.9 kN
Project Job Ref.
Effective length of weld lweld = 4 (Bbeam/ 2 - tbeam/ 2 - rbeam- sweld) + 2 (dbeam + 2 rbeam) = 516.0 mm
Design strength of weld pweld = 220 N/mm2
Capacity of fillet welds Pweld = pweld lweld aweld = 476.8 kN
Utilisation factor Ucheck5weld = Q / Pweld = 0.180
Capacity of fillet weld : PASS
Check 6 - Local shear and bearing capacity of column flange
for shear
etbeama = etbeam = -50 mm
Avcolumn = (pbolts + (nbolts - 1) pbolts + etbeama) Tcolumn = 5100 mm2
Avnetcolumn = Avcolumn - nbolts Dhbolts Tcolumn = 4855 mm2
SUMMARY OF RESULTS
Check 2 - Shear capacity of bolt group connecting end plate to supporting column
Shear utilisation factor Ucheck2 = 0.365 PASS
Check 3 - Capacity of end plate
Shear utilisation factor Ucheck3shear = 0.059 PASS
Bearing utilisation factor Ucheck3bearing = 0.292 PASS
Check 4 - Shear capacity of the beam web at the endplate
Shear utilisation factor Ucheck4shear = 0.589 PASS
Check 5 - Capacity of the fillet welds connecting the end plate to the beam web
Project Job Ref.
Hence, use
4 No. M16 gr. 8.8 bolts @ 90 & 400 c/c with 150 x 550 x 10 end plate