You are on page 1of 3
@® Allen-Bradley Powe: ; Adjustable Frequency AC Drive FRN 3.xx User Manual Automation Important User Informat Solid state equipment has operational characteristics differing from those of electromechanical equipment. “Safety Guidelines for the Application, Installation and Maintenance of Solid State Controls” (Publication SGI-1.1 available from your local Rockwell Automation Sales Office or online at http/fwww.ab.com/ manuals/gi) describes some important differences between solid state equipment and hard-wired electromechanical devices. Because of this difference, and also because of the wide variety of uses for solid state equipment, all persons responsible for applying this equipment must satisfy themselves that each intended application of this equipment is acceptable. In no event will Rockwell Automation, Inc. be responsible or liable for indirect or consequential damages resulting from the use ot application of this equipment. The examples and diagrams in this manual are included solely for illustrative purposes. Because of the many variables and requirements associated with any particular installation, Rockwell Automation, Inc. cannot assume responsibility or liability for actual use based on the examples and diagrams, No patent liability is assumed by Rockwell Automation, Inc. with respect to use of information, circuits, equipment, or software described in this manual. Reproduction of the contents of this manual, in whole or in part, without written permission of Rockwell Automation, Inc. is prohibited, Throughout this manual we use notes to make you aware of safety considerations, ATTENTION: Identifies information about practices or circumstances A that can lead to personal injury or death, property damage, or economic loss. Attentions help you: © identify a hazard © avoid the hazard ‘© recognize the consequences Important: Identifies information that is especially important for successful application and understanding of the product. Shock Hazard labels may be located on or inside the drive to alert 4 people that dangerous voltage may be present. Burn Hazard labels may be located on or inside the drive to alert people that surfaces may be at dangerous temperatures, DeiveBxplorer,DriveToos82, and SCANpor are tademars of Rockwell Automaton PLC ie a egiseedtademare of Rockwell Astomation, DeviceNet ia trademark of the Open DeviceNet Vendor Asoration, Summary of Changes ‘The information below summarizes changes made for the October 2003 PowerFlex 4 User Manual, Publication 22A-UMOOLE-EN-E, Description of New or Updated Information [See Page(s) 240V, 1-Phase, No Brake drive ratings added. [Ps4, Be7, A, Bel Position 12 ofthe Catalog Number now indicates dive typ. [Psa Flange Mount drive enclosure added, P. Analog Input wiring examples updated. lita Al tive ratings now support dynamic braking. lez Frame C EMC Line Filter dimensions added B12 Remote Small HIM, Cat, No. 22-HIM-C2S, dimensions added, The information below summarizes changes made for the May 2003 PowerFlex 4 User Manual, Publication 22A-UM001D-EN-E. Description of New or Updated information See Page(s) T2OV, Phase, 1.1 KW (1.5 HP) drive rating added Section on RU45 DSI Splitter Cable added. ‘The following parameters have been added: 024 [Drive Temp] A115 [Process Time Lo] A116 [Process Time Hi Options have been added to te folowing parameters ‘AOS! [Dig int Sel] A062 [Dig n2 Sel] A055 [Relay Out Sol]

You might also like