Drain connection
for condensate removal.
2
How the CSF16 works
The most basic method of contaminant removal in fluids is by 'retention' i.e. solids
larger than a hole size in a filter medium are mechanically retained on the upstream
surface or trapped within the hole. This is put to good effect in strainers, however a
strainer screen will only retain some particles, long, thin particles can still pass
through the holes. To overcome this we effectively need a succession of strainer
screens where the screens are staggered.
The majority of the particles are retained on the surface of the filter, but long thin particles can also be captured by the
depth of the filter. This method of retention is called inertial impaction. This is exactly how a sintered metal filter works.
The sintered process provides a suitable medium for such filtration. The sintered filter has a high porosity, more
than 50%, ensuring a high dirt holding capacity and good flow characteristics.
User benefits
• Cleanable element reduces total cost of ownership.
• Complete filter stations available from Spirax Sarco ensures
equipment compatibility.
In order to achieve this, a dry, clean saturated steam supply is required, free from incondensible gases and
filtered to 5 microns or better.
Sterilisers / Autoclaves
The steam supply to sterilisers and autoclaves in the pharmaceutical and
health care industries must be clean in order to prevent spotting or any other
type of contamination. National standards in many countries cover the design
and control of these devices, which in some cases also refer to steam purity
e.g. when factory steam is being used then it must be filtered.
3
Dimensions / weights and volume (approximate) in mm, kg and litres
Size Volume Weight (*without element) B
Type
DN NPS Scr* Flg* Element A NPT, BSP ANSI 150 DIN PN16 C D E F
10 ¼" 0.55 1.7 3.7 0.20 215 108 205 180 55 90 70 112
10 ³/8" 0.55 1.7 3.7 0.20 215 108 205 180 55 90 70 112
15 ½" 0.65 1.8 4.2 0.37 245 108 205 180 55 120 70 112
CSF16 and T 20 ¾" 0.75 2.0 4.4 0.45 270 125 230 202 62 150 70 112
25 1" 1.00 2.7 5.7 0.47 300 125 248 212 75 150 85 127
32 1¼" 1.25 3.2 6.6 0.51 350 140 257 220 75 200 85 127
40 ½" 2.00 4.0 10.1 1.27 380 160 285 245 80 200 104 148
65 2½" 8.50 8.9 19.6 2.77 765 200 340 290 110 580 129 178
50 2" 3.20 4.7 10.6 1.60 455 170 298 260 80 280 104 148
CSF16L and LT
80 3" 11.50 10.8 23.8 3.81 1005 200 340 300 110 850 129 178
50 2" 3.80 5.3 11.7 2.25 580 170 298 260 80 450 104 148
CSF16H and HT
80 3" 16.50 14.3 35.7 4.90 1035 240 380 340 125 850 154 210
Note: T = Made from 316Ti Material
L = Low capacity
H = High capacity Operating range
F DN10 to DN80
E 200
178
Temperature °C
150
¼"
100 Steam
saturation
50 curve
0
D (min) 0 2 4 6 8 8.6* 10 12 14 16
Pressure bar g
The product must not be used in this region.
A 154
100 Steam
saturation
50
curve
0
0 2 4 4.5* 6 8 10 12 14 16
Pressure bar g
C The product must not be used in this region.
The product should not be used in this region
due to limitations of the EPDM housing seal.
¼" Temperatures up to 178°C are available using
a Fluoraz seal.
B
SFSS
4
SB-P185-06 ST Issue 2