PRESSURIZATION CONTROL SYSTEM -- MAINTENANCE PRACTICES
1. General
A. Maintenance practices for the pressurization control system
consists of an operational test for the pressurization control
system.
B. The pressurization control system operational test provides a
method for making periodic quick checks of the pressurization
control system ability to switch into, or from, either of its
modes of operation.
C. Although the test does not provide a complete check of the
pressurization control system, it does assure that system will
switch from auto to standby and that standby and manual control
are available if needed during flight. Refer to Pressurization
Control System -- Adjustment/Test for a complete functional
test of the system.
D. To prevent inadvertent cabin pressurization, an airplane door
must be opened if air is being supplied to air conditioning
packs from a ground cart or APU/ENGINE.
2. Prepare to Operationally Test Pressurization Control System
A. Provide electrical power.
B. Check that following circuit breakers on panel P6 are closed.
(1) MANUAL DC
(2) STBY DC POWER
(3) AUTO DC POWER
(4) AUTO AC POWER
(5) PRESS CONT IND LTS
(6) MANUAL AC POWER
(7) STBY AC POWER
(8) On all except N201FE-N217FE, place cargo door switch to
DISARM.