You are on page 1of 4

B727 AMM - GASPER FAN - REMOVAL/INSTALLATION

Revision

FED ALL
GASPER FAN - REMOVAL/INSTALLATION
1. General
A. The gasper fan is utilized in augmenting individual crew member
cooling or ventilation. The fan is accessible through access
door No. 1314 located at the rear of the lower forward cargo
compartment. For airplanes with forward auxiliary fuel tank,
access may be gained by removing 2 ea. roller rails and 1
ea. main cargo floor panel marked “FIRE BOTTLE ACCESS”. Panel
is located on the right hand side of the aircraft between
stations 720c to 720d.
2. Remove Gasper Fan (Fig. 401)
A. Gain access to fan by opening access door or floor panels as
required..
B. Open GASPER FAN circuit breaker on panel P6.
C. Remove electrical connector and bonding jumper from fan.
D. Remove the two clamps securing the fan to the inlet and outlet
ducts.
E. Remove fan.
3. Install Gasper Fan
A. Position fan in line with ducts with the electrical connector
receptacle up and loosely install clamps.
B. Tighten duct clamps.
C. Check that bonding surfaces are clean, then install bonding
jumper.
D. Install electrical connector on top of fan.
E. Close GASPER FAN circuit breaker.
F. Check that A/C PACK switches are at CLOSE.
G. Provide electrical power.

P.Blk EFFECTIVITY: ALL 21-23-011-4


Page 1 of 4
Printed - Date: 12/10/15 Time:
Copyright © 15 FedEx Express Corporation, Memphis TN, 38194, All rights reserved. SEP 01/2007
B727 AMM - GASPER FAN - REMOVAL/INSTALLATION
Revision

H. Move GASPER FAN switch on third crewman"s upper panel to ON and


check that fan provides airflow by opening any gasper air
outlet.
I. Check for air leakage at fan duct clamps. Leakage is excessive
if air flow can be felt on a hand 12 inches from the surface.
J. Place SMOKE CONTROL switch on third crewman"s upper panel to
ON. Airflow should stop. Return SMOKE CONTROL switch to NORMAL.
K. Move GASPER FAN switch to OFF.
L. Remove electrical power if no longer required.
M. Close access panel or re-install main cargo floor panels.

P.Blk EFFECTIVITY: ALL 21-23-011-4


Page 2 of 4
Printed - Date: 12/10/15 Time:
Copyright © 15 FedEx Express Corporation, Memphis TN, 38194, All rights reserved. SEP 01/2007
B727 AMM - GASPER FAN - REMOVAL/INSTALLATION
Revision

Gasper Fan Installation


Figure 401 (Sheet 1)

P.Blk EFFECTIVITY: ALL 21-23-011-4


Page 3 of 4
Printed - Date: 12/10/15 Time:
Copyright © 15 FedEx Express Corporation, Memphis TN, 38194, All rights reserved. SEP 01/2007
B727 AMM - GASPER FAN - REMOVAL/INSTALLATION
Revision

FED ALL

P.Blk EFFECTIVITY: ALL 21-23-011-4


Page 4 of 4
Printed - Date: 12/10/15 Time:
Copyright © 15 FedEx Express Corporation, Memphis TN, 38194, All rights reserved. SEP 01/2007