VERTICAL KNEE TEE BRACE TO COLUMN OR BEAM FLANGE (*VTBKc-*) 16d

NUMBER OF MAX
ANGLE / BRACE GUSSET PL CONNECTION BUCKLING
TEE FLANGE THICKNESS BOLTS IN THICKNESS WELD SIZE
CONNECTION NAME SLOPE GAUGE BOLTS CAPACITY LENGTH (L0)
WIDTH (mm) (mm) BRACE "tg"(mm) W1 (mm)
(degree) g (mm) (kN) (mm)
"N"
*VTBKc-01a 35 to 55 140-150 8-10 70 4 M20 Grade 8.8 10 6 310 250
*VTBKc-02a 35 to 55 151-175 9-11 90 4 M20 Grade 8.8 10 6 310 250
*VTBKc-03a 35 to 55 176-200 11-17 120 6 M20 Grade 8.8 12 6 485 250
*VTBKc-03b 35 to 55 176-200 11-17 120 4 M20 Grade 8.8 10 6 325 250
*VTBKc-04a 35 to 55 201-250 12-14 140 6 M20 Grade 8.8 12 6 560 250
*VTBKc-04b 35 to 55 201-250 12-14 140 4 M20 Grade 8.8 10 6 345 250
*VTBKc-05a 35 to 55 251-350 15-20 140 8 M20 Grade 8.8 14 8 750 250
*VTBKc-05b 35 to 55 251-350 15-20 140 4 M20 Grade 8.8 10 6 370 250
*VTBKc-06a 35 to 55 351-400 20-24 140 10 M20 Grade 8.8 14 8 940 250
*VTBKc-06b 35 to 55 351-400 20-24 140 4 M20 Grade 8.8 10 6 370 250

Important Notes: 1) These Connections are applicable to bracing members subjected to only Axial Load.
2) Grouping of the members is done on the basis of a fixed range of width of the connecting side for a similar shape of the sections.
3) The Connection Capacity tabulated above is for the section (among the group of members) for a profile with minimum leg size and thickness. It would definitely be
higher for other members in the same group.
4) The connection capacity is the factored axial member load as per ENV 1993-1-1:1992
5) For a member with end connection detail other than as specified and/or member force higher than the specified value in the table, the connection has to be designed
and developed as a special one.
6) The capacities calculated are valid for S355JR ( British) and Q345B ( Chinese) grade of steel.

Sheet 1 of 4
Connection Library

CHEVRON VERTICAL TEE BRACE TO BEAM (*VTBCHb-*) 16e

MAX
NUMBER OF GUSSET PL
ANGLE / BRACE CONNECTION BUCKLING
TEE FLANGE THICKNESS BOLTS IN THICKNESS WELD SIZE
CONNECTION NAME SLOPE GAUGE BOLTS CAPACITY LENGTH (L0)
WIDTH (mm) (mm) BRACE "tg"(mm) W1 (mm)
(degree) g (mm) (kN) (mm)
"N"

*VTBCHb-01a 35 to 55 140-150 8-10 70 4 M20 Grade 8.8 10 6 310 250


*VTBCHb-02a 35 to 55 151-175 9-11 90 4 M20 Grade 8.8 10 6 310 250
*VTBCHb-03a 35 to 55 176-200 11-17 120 6 M20 Grade 8.8 12 6 485 250
*VTBCHb-03b 35 to 55 176-200 11-17 120 4 M20 Grade 8.8 10 6 325 250
*VTBCHb-04a 35 to 55 201-250 12-14 140 6 M20 Grade 8.8 12 6 560 250
*VTBCHb-04b 35 to 55 201-250 12-14 140 4 M20 Grade 8.8 10 6 345 250
*VTBCHb-05a 35 to 55 251-350 15-20 140 8 M20 Grade 8.8 14 8 750 250
*VTBCHb-05b 35 to 55 251-350 15-20 140 4 M20 Grade 8.8 10 6 370 250
*VTBCHb-06a 35 to 55 351-400 20-24 140 10 M20 Grade 8.8 14 8 940 250
*VTBCHb-06b 35 to 55 351-400 20-24 140 4 M20 Grade 8.8 10 6 370 250

Important Notes: 1) These Connections are applicable to bracing members subjected to only Axial Load.
2) Grouping of the members is done on the basis of a fixed range of width of the connecting side for a similar shape of the sections.
3) The Connection Capacity tabulated above is for the section (among the group of members) for a profile with minimum leg size and thickness. It would definitely be higher
for other members in the same group.
4) The connection capacity is the factored axial member load as per ENV 1993-1-1:1992
5) For a member with end connection detail other than as specified and/or member force higher than the specified value in the table, the connection has to be designed
and developed as a special one.
6) The capacities calculated are valid for S355JR ( British) and Q345B ( Chinese) grade of steel.

Sheet 2 of 4
Connection Library

VERTICAL TEE BRACE CONNECTION @ BEAM-COLUMN FLANGE INTERFACE (*VTBbc-*)

16f

CONNECTION
ANGLE/ TEE FLANGE BRACE NUMBER OF NUMBER BOLTSPACE GUSSET PL WELD WELD CONNECTION
THICKNESS BOLTS PL Max. Buckling
CONNECTION NAME SLOPE WIDTH GAUGE BOLTS OF BOLTS ON WSP THICKNESS SIZE SIZE CAPACITY
(mm) THICKNESS Length Lo (mm)
(degree) (mm) 'g' (mm) "Nvb" "Nc" "BoltSpac" "tg"(mm) "W1" (mm) "W2" (mm) (kN)
"tc"(mm)

*VTBbc-01a 35 to 55 140-150 8-10 70 4 M20 Grade 8.8 3 VARIES 10 10 6 6 310 250


*VTBbc-02a 35 to 55 151-175 9-11 90 4 M20 Grade 8.8 3 VARIES 10 10 6 6 310 250
*VTBbc-03a 35 to 55 176-200 11-17 120 6 M20 Grade 8.8 5 VARIES 12 12 6 6 485 250
*VTBbc-03b 35 to 55 176-200 11-17 120 4 M20 Grade 8.8 3 VARIES 10 10 6 6 325 250
*VTBbc-04a 35 to 55 201-250 12-14 140 6 M20 Grade 8.8 5 VARIES 12 12 6 6 560 250
*VTBbc-04b 35 to 55 201-250 12-14 140 4 M20 Grade 8.8 3 VARIES 10 10 6 6 345 250
*VTBbc-05a 35 to 55 251-350 15-20 140 8 M20 Grade 8.8 7 VARIES 14 14 8 8 750 250
*VTBbc-05b 35 to 55 251-350 15-20 140 4 M20 Grade 8.8 4 VARIES 10 10 6 6 370 250
*VTBbc-06a 35 to 55 351-400 20-24 140 10 M20 Grade 8.8 8 VARIES 14 14 8 8 940 250
*VTBbc-06b 35 to 55 351-400 20-24 140 4 M20 Grade 8.8 4 VARIES 10 10 6 6 370 250

Important Notes: 1) These Connections are applicable to bracing members subjected to only Axial Load.
2) Grouping of the members is done on the basis of a fixed range of width of the connecting side for a similar shape of the sections.
3) The Connection Capacity tabulated above is for the section (among the group of members) for a profile with minimum leg size and thickness. It would definitely be higher
for other members in the same group.
4) The connection capacity is the factored axial member load as per ENV 1993-1-1:1992
5) For a member with end connection detail other than as specified and/or member force higher than the specified value in the table, the connection has to be designed and
developed as a special one.
6) The capacities calculated are valid for S355JR ( British) and Q345B ( Chinese) grade of steel.

Sheet 3 of 4
Connection Library

VERTICAL TEE BRACE CONNECTION @ BASEPLATE, COLUMN FLANGE (*VTBcb-*)

16g

NUMBER OF MAX
ANGLE / BRACE GUSSET PL CONNECTION BUCKLING
TEE FLANGE THICKNESS BOLTS IN THICKNESS WELD SIZE
CONNECTION NAME SLOPE GAUGE BOLTS CAPACITY LENGTH (L0)
WIDTH (mm) (mm) BRACE "tg"(mm) W (mm)
(degree) g (mm) (kN) (mm)
"N"
*VTBcb-01a 35 to 55 140-150 8-10 70 4 M20 Grade 8.8 10 6 310 250
*VTBcb-02a 35 to 55 151-175 9-11 90 4 M20 Grade 8.8 10 6 310 250
*VTBcb-03a 35 to 55 176-200 11-17 120 6 M20 Grade 8.8 12 6 485 250
*VTBcb-03b 35 to 55 176-200 11-17 120 4 M20 Grade 8.8 10 6 325 250
*VTBcb-04a 35 to 55 201-250 12-14 140 6 M20 Grade 8.8 12 6 560 250
*VTBcb-04b 35 to 55 201-250 12-14 140 4 M20 Grade 8.8 10 6 345 250
*VTBcb-05a 35 to 55 251-350 15-20 140 8 M20 Grade 8.8 14 8 750 250
*VTBcb-05b 35 to 55 251-350 15-20 140 4 M20 Grade 8.8 10 6 370 250
*VTBcb-06a 35 to 55 351-400 20-24 140 10 M20 Grade 8.8 14 8 940 250
*VTBcb-06b 35 to 55 351-400 20-24 140 4 M20 Grade 8.8 10 6 370 250

Important Notes: 1) These Connections are applicable to bracing members subjected to only Axial Load.
2) Grouping of the members is done on the basis of a fixed range of width of the connecting side for a similar shape of the sections.
3) The Connection Capacity tabulated above is for the section (among the group of members) for a profile with minimum leg size and thickness. It would definitely be higher
for other members in the same group.
4) The connection capacity is the factored axial member load as per ENV 1993-1-1:1992
5) For a member with end connection detail other than as specified and/or member force higher than the specified value in the table, the connection has to be designed and
developed as a special one.
6) The capacities calculated are valid for S355JR ( British) and Q345B ( Chinese) grade of steel.

Sheet 4 of 4