Brushless DC motor drives and its applications – Variable reluctance and permanent
magnet stepper motor Drives – Operation and control of switched reluctance motor –
Applications, modern trends in industrial drive.
Total: 45
TEXT BOOKS
1. Bimal K. Bose, “Modern Power Electronics and AC Drives”, Pearson Education, 2002.
2. Dubey, G.K., “Fundamentals of Electrical Drives”, 2nd Edition, Narosa Publishing
House, 2001.
REFERENCES
1. Pillai, S.K., “A First Course on Electrical Drives”, Wiley Eastern Limited, 1993.
2. Krishnan, R., “Electric Motor and Drives Modelling, Analysis and Control”, Prentice
Hall of India, 2001.
UNIT I FUNDAMENTALS OF ELECTRIC DRIVES
Advantage of Electric Drives – Parts and choice of Electrical Drives – Status of DC and AC
drives – Torque-speed characteristics of motor and load – Selection of Motor power
rating – Thermal model of motor for heating and cooling – Classes of duty cycle –
Determination of motor rating – Control of Electric drives – Modes of operation – Speed
control and drive classifications – Closed loop control of drives.
Drive:
Drive is a system which supplies mechanical energy for motion control.
Electric Drive:
An electric drive is a system that converts electrical energy to mechanical energy.
Input Command
Sources:
• Mostly Single and Three phase 50Hz supply is used base on the power
requirements.
• When 50Hz Supply is used, maximum of 3000 RPM can only be obtained. For
increased speed, higher frequency supply is required.
• For low and medium power ratings: 400V used.
• For Higher power ratings: 3.3kV, 6.6kV, 11kV and higher voltages are used.
• Some drives are powered from battery and even solar powered drives are also
used. But these drives are not economical and having restrictions.
• Type of motor used is independent of the supply available.
Power Modulator:
• The switches within the converter are controlled by the modulator which
determines which switches should be on, and for what time interval, normally on
a micro-second timescale. An example is the Pulse Width Modulator that realizes
a required pulse width at a given carrier frequency of a few kHz.
• The power modulators are classified as follows:
o Converters
AC to DC Converters – Variable DC Voltage
AC Voltage Regulators – Variable AC Voltage
Choppers – Variable DC Voltage
Inverters
i. Stepped wave inverter – Variable Frequency Fixed Voltage
ii. PWM Inverter – Variable Frequency Variable Voltage
Cycloconverters – Variable Frequency and Variable Voltage
o Variable impedances: Variable resistors are commonly used for the
control and dynamic breaking of low cost AC and DC drives. In high power
applications, liquid rheostats are employed to get stepless variation of
resistance. Two step (full and zero) inductors are employed for limiting
starting current of AC motors.
o Switching Circuits:
Switching operations are performed by high power electromagnetic
relays. Now a day, thyrister switches are used.
Switching operations are required for the following:
i. For changing motor connections to change its quadrant of
operation
ii. For changing motor circuit parameters in discrete steps for
automatic starting and braking control
iii. For operating motors and drives according to predetermined
sequence
iv. To provide interlocking to prevent maloperation and
v. To disconnect motor when abnormal operating conditions
occur.
Control Unit:
• Controls for a power modulator are provided in the control unit.
• The control unit, typically a digital signal processor (DSP), or micro-controller
contains a number of software based control loops which control, for example,
the currents in the converter and machine.
• In addition torque, speed and shaft angle control loops may be present within this
module. Shown in the diagram are the various sensor signals which form the key
inputs to the controller together with a number of user set-points (not shown in
the diagram). The output of the controller is a set of control parameters which
are used by the modulator.
Motors:
• DC Mots:
o Shunt, series, compound and permanent magnet motors
• Induction motors:
o Squirrel cage, slip ring and linear induction motors
• Synchronous Motors:
o Wound field and permanent magnet motors
• For variable speed operations, DC motors are preferred. The development of solid
state devices helps to use AC motors in variable speed applications.
• Because of numerous advantages of AC motors, AC drives have succeeded DC
drives in a number of variable speed applications.
Let,
J – Moment of inertia of the motor-load system referred to the motor shaft (kg-m2)
ωm - Instantaneous angular velocity of motor shaft (rad/sec)
T- Instantaneous value of developed motor torque (Nm)
Tl- Instantaneous value of load torque (Opposing torque including friction and
windage) referred to motor shaft (Nm)
By the fundamental torque equation,
T − Tl =
d
( Jω m ) = J dω m + ω m dJ (1)
dt dt dt
The above equation is applicable to variable inertia drives used in mine winders,
industrial robots etc., but for constant inertia,
dJ
=0
dt
Then,
dω m
T − Tl = J
dt
dω m
T=J + Tl → ( 2)
dt
From equation (2), it is clear that the torque developed by the motor (T) is counter
balanced by the load torque (Tl) and a dynamic torque J(dωm/dt). The term J(dωm/dt) is
called dynamic torque because it is present only during the transient operations.
Acceleration and deceleration of the drive depends on the values of T and Tl. For
acceleration, T> Tl and for deceleration, T< Tl.During acceleration, the motor torque not
only overcome the load torque but it supplies to dynamic torque J(dωm/dt) to overcome
drive inertia.
In drives with larger inertia, like electric trains, motor torque must exceed the load
torque by a large amount in order to get sufficient acceleration. When fast transient
response required, motor torque should be maintained at larger rate and the system
should be designed with lowest inertia.
The energy associated with dynamic torque is stored as kinetic energy assists the
motor torque T and maintains drive motion.
Load Tl1
n1
ωm1
• The motor is driving two loads. One load is directly driven and other is a through
gear with ‘n’ and ‘n1’ teeth.
• Let,
o J0 – Moment of inertia of motor and directly coupled load
o ωm – Speed of the motor
o Tl0 – Torque of the directly coupled load
o J1 – Moment of inertia of load coupled through gear
o ωm1 – Speed of the load coupled through gear
o Tl1 – Torque of the load coupled through gear
• Now,
ω m1 n
= = a1 , Gear Tooth Ratio
ωm n1
• Neglecting transmission losses, the kinetic energy due to equivalent inertia must
be same as the kinetic energy of various moving parts. Thus,
1 1 1
Jωm2 = J 0ωm2 + J 1ωm2 1
2 2 2
1 1 ω2 ω2
J = J 0 m2 + J 1 m21
2 2 ωm ωm
i.e., J = J 0 + J 1
• Power at the loads and motor must be same. If transmission efficiency of the
gears be η 1, then
Tl1ωm1
Tl ωm = Tl 0ωm +
η1
where Tl is the total equivalent torque referred to motor shaft.
Then,
Tl1ωm1
Tl = Tl 0 +
η1ωm
Tl1
Tl = Tl 0 + a1
η1
• If in additional load directly coupled to the motor with inertia J0 there are m other
loads with moment of inertias J1,J2,.....,Jm and gear ratios of a1,a2,.....,am then
J = J 0 + a12 J 1 + a 22 J 2 + .......... + a m2 J m
Tl1 Tl 2 T
and Tl = Tl 0 + a1 + a2 + ....... + +a m lm
η1 η2 ηm
• If the load is driven by belt drive instead of gears, then, neglecting slippage, the
equivalent inertia and torque can be obtained from the above equations by
considering a1,a2,.....,am each to be the ratios of diameters of wheels driven by
motor to the diameters of wheels mounted on the load shaft.
Loads with Translational Motion:
ωm ωm
Mass M1
Force F1
v1
• The motor is driving two loads. One load is directly driven and other is a through
a transmission system which is converting rotational motion in to linear motion.
• Let,
o J0 – Moment of inertia of motor and directly coupled load
o ωm – Speed of the motor
o Tl0 – Torque of the directly coupled load
o M1- Mass of the load with translational motion(kg)
o v1 – Velocity of the load with translational motion (m/sec)
o F1 – Force of the load with translational motion (N)
• Neglecting transmission losses, the kinetic energy due to equivalent inertia must
be same as the kinetic energy of various moving parts. Thus,
1 1 1
Jωm2 = J 0ωm2 + M 1v112
2 2 2
1 1 ω 2
v2
J = J 0 m2 + M 1 12
2 2 ωm ωm
2
v
i.e., J = J 0 + M 1 1
ωm
• Similarly, power at the motor and load should be same, thus if efficiency of
transmission be η 1, then
F1v1
Tl ωm = Tl 0ωm +
η1
F1 v1
Tl = Tl 0 +
η1 ωm
where Tl is the total equivalent torque referred to motor shaft.
• If in addition to one load directly coupled to the motor shaft, there are ‘m’ other
loads with translational motion with velocities v1,v2,…..,vm and M1,M2,…..,Mm,
respectively, then
2 2 2
v v v
J = J 0 + M 1 1 + M 2 2 + ......... + M m m
ω
ωm ωm m
F1 v1 F2 v2 F vm
and Tl = Tl 0 + + + .......... ..... + m
η1 ωm η2 ωm ηm ωm
Torque Speed Characteristics of Electrical Motors:
• The main advantage of electrical drives is that their wide range of speed
variation. They are explained below:
o The characteristic curve II shows that the speed is slightly reduced when
the load torque increases.
• DC Series Motor:
o The speed is high at light load and low at heavy loading condition as
shown in the curve III.
• Induction Motors:
o During steady state, they operate at the linear proportion of speed torque
characteristic, which resembles the characteristic of a DC shunt motor.
• In electric drive applications, the selection of the motor should match with the
required performance of the loads. For example, the synchronous motor is
probably the best option for the constant speed applications. Other motors, such
as induction or DC shunt motors can also be used in constant speed applications,
provided that feedback circuits are used to compensate for the change in speed
when load torque changes.
• Improper selection of motor power rating results extra initial cost and extra loss
of energy du tot operation below rated power makes the choice uneconomical.
• During operation of the machine, heat is produced due to losses and temperature
rises. An amount of developed heat is dissipated into the atmosphere. When the
dissipation of heat is equal to the developed heat, then it is said to be equilibrium
condition. Motor temperature then reaches a steady state value.
• Steady state temperature depends on power loss, which in turn depends on the
output power of the machine. Since temperature rise has a direct relation with
the output power, it is termed thermal loading on the machine.
• Insulating materials have lowest temperature limit. They are classified based on
temperature limit as follows:
• It is simple to calculate the motor power rating of the motor which operate at
a constant power and speed. But most loads operate at variable power and
speed at different applications.
• It is difficult to predict the heat flow and temperature rise inside an electrical
motor because of its complex geometry and heterogeneous materials.
• Assuming nearly equal thermal conductivity in all the materials (i.e, assuming
homogeneous), simple thermal model can be obtained. It helps us to select the
motor for a particular application.
or Wh dθ = p1 dt - p2 dt (1)
where, Thermal capacity of the machine, C=Wh (Watts/0C) (4) and heat
dissipation constant, D=dA (Watts/0C) (5). The first differential equation of the
equation (3) is,
p1
θ= + Ke −t /( C / D )
D
θ = θ ss + Ke −t / τ → (6)
The value of K is obtained by substituting t=0 in (6). When the initial temperature
rise is θ 1,
τ τ
θ =θ ss (1-e-t/ )+θ 1e-t/ → (9)
When t=∞ in equation (9), θ =θ ss. Thus θ ss is the steady state temperature
when the machine is continuously heated by the power p1. Up to this temperature
all the heat produced by the machine is dissipated to the surrounding medium.
• Let the load on the machine be removed after reaching temperature θ 2,. Heat
loss will reduce to a small value p1’ and cooling operation of the motor will begin.
Let the new value of heat dissipation constant be D’. If time is measured from the
instant the load is removed, then
dθ
C = p1' − D 'θ → (10 )
dt
−t
'
−t
θ = θ ss' 1 − e τ + θ 2 e τ → (11)
'
If the motor were disconnected from the supply during cooling then p’ 1=0 gives
θ ’ss=0, suggesting that the final temperature attained by the motor will be
ambient temperature. Therefore equation (11) becomes,
−t
θ = θ 2e τ'
→ (14)
• Equations (9) and (14) suggest both heating time constant τ and cooling time
constant τ ’ based on respective heat dissipation constants D and D’, which in
turn depend on the velocity of the cooling air.
• In self cooled motors, fans are mounted at the shaft and hence the velocity of the
air varies with the speed, thus varying cooling time constant τ ’. Cooling time
constant at standstill is much larger than when running. Therefore, in high
performance, medium and high power variable speed drives, motor is always
provided with separate forced cooling, so that motor cooling be independent of
speed.
• The above figure shows the variation of motor temperature rise with time during
heating and cooling. Thermal time constants of a motor are far larger than
electrical and mechanical time constants. While electrical and mechanical time
constants have typical ranges of 1 to 100ms and 10ms to 10s, the thermal time
constants may vary from 10 min to couple of hours.
1. Continuous Duty:
Cooling
Heating
0
t
Heating and Cooling Curves
It denotes the motor operation at a constant load torque for duration long enough
for the motor temperature to reach steady state value. This duty cycle is
characterized by constant motor losses. Ex: Paper mill drives, Compressors,
Conveyers, centrifugal pumps and fans.
The operation of the drive is less than the heating time constant in this case and
the machine is allowed to cool to ambient temperature before to operate again.
In this case, the machine can be overloaded to permissible limit. Ex: Crane
drives, drives for house hold appliances, turning bridges, valve drives etc.
In this case, the heating during starting cannot be ignored. It consists of a period
of starting, a period of operation at constant load and a rest period being too
short for the respective steady state temperature to be attained. Ex: Metal
Cutting and drilling tool drives, drives for fork lift trucks, mine hoist etc.
In this case, the heating during starting and braking cannot be ignored. It
consists of a period of starting, a period of operation at constant load, a braking
period with electrical braking and a rest period; with operating and a rest periods
being too short for the respective steady state temperature to be attained. Ex:
Billet mill drive, manipulator drive, ingot buggy drive, schrewdown mechanism of
blooming mill etc.
It consists of a period of running at one load and speed, and another period of
running at different speed and load; again both operating periods are too short
for respective steady state temperatures to be attained. There is no period of
rest.
Determination of Motor Rating:
For calculation of motor rating, the duty cycles can be mainly classified in to,
1. Continuous duty
2. Fluctuating loads
1. Continuous Duty:
A motor with next higher power rating compared with the maximum power demand
is selected with consideration of the following factors:
This method can be employed for Intermittent Periodic Duty and Continuous duty
with periodic speed changes. It is based on approximation that the actual variable
motor current can be replaced by an equivalent I eq which produces same losses in the
motor as actual current.
Motor losses = Constant losses+ Copper loss.
For fluctuating loads with n value of motor currents I1,I2,…,In for durations t1,t2,…,tn
respectively, the equivalent current Ieq is given by
pc + I 2
R=
(p c ) ( ) ( )
+ I 12 R t1 + p c + I 22 R t 2 + ..... + p c + I n2 R t n
eq
t1 + t 2 + ....... + t n
or p c + I R =
2
+
(
p c ( t1 + t 2 + ....... + t n ) I 12 t1 + I 22 t 2 + ....... + I n2 t n R )
eq
t1 + t 2 + ....... + t n t1 + t 2 + ....... + t n
or I eq =
(I t + I 22 t 2 + ....... + I n2 t n
2
1 1 )
t1 + t 2 + ....... + t n
If the current varies smoothly over a period T can be written as,
/T
1
I eq = ∫i
2
dt
T 0
DC Motor:
This motor can be allowed to carry larger (2 to 3.5 times) than the rated current for
a short duration. This is known as short time overload capacity of the motor.
Ratio of maximum allowable current (short time overload capacity) to rated current
be denoted by λ . Then
I max
λ≥
I rated
If the above condition is not satisfied, then the motor current rating is calculated
from
I max
I rated ≥
λ
Induction and Synchronous Motor:
• For stable operation of induction and synchronous motors, the maximum load
torque should be within the breakdown torque.
• In normal design of induction motors, the ratio of breakdown to rated torque
varies from 1.65 to 3 and for synchronous motors 2 to 2.25. Then the rating can
be selected by
Tmax
Trated ≥
λ
• When the load has high pulses, selection of motor rating based on this will be too
large. Load equalization is made by mounting flywheel on the shaft.
• When torque is directly proportional to current, then
Teq =
(T 2
t + T22t2 + ....... + Tn2tn
1 1 )
t1 + t2 + ....... + tn
When the motor operates at constant speed, its power will be directly
proportional to torque. Therefore,
Peq =
(P t
2
1 1 + P22t2 + ....... + Pn2tn )
t1 + t2 + ....... + tn
Control of Electrical drives:
The following conventions govern the power flow analysis of the electric drive systems:
i. When the torque and speed of the machine are in the same direction, then the
machine is operating as a motor (consume electric energy from the source and
delivers mechanical power to the load).
ii. If the speed and torque of the machine are in the opposite directions, the
machine is acting as a generator (consume mechanical energy from load and
delivers electric power to the load).
1st Quadrant (Forward Motoring):
• The torque and speed of the motor are in the same direction. Of course, the load
torque is opposite to the machine torque.
• The electrical machine in this case is operating as a motor. The flow of power is
from the machine to the load.
• The speed direction is unchanged while the direction of the torque is reversed.
• Since the load torque direction is in the same direction of speed, the mechanical
load is delivering power to the machine.
• Compared to the first quadrant, the system speed and torque are reversed in the
third quadrant.
• Since the torque and speed of the machine are in the same direction, the power
flow is from the machine to the load. The machine is therefore acting as a motor
rotating in the reverse direction to the speed of the first quadrant.
• Bidirectional grinding machine is the good example of the 1 st and 3rd quadrant
operation. The direction of the load torque of the grinding load is reversed when
the speed is reversed (3rd quadrant). A horizontal conveyor belt is another
example of this type of operation.
• The torques remains unchanged as compared to the first quadrant. The speed,
however, changes the direction.
• From the load perspective, the load torque and the speed are in the same
direction. Hence the power flow is from the load to the machine.
• The machine is in this case acting as generator delivering the electric power to
the source.
• The first and fourth quadrant of operation can be explained with the elevator.
When the elevator is going upward or downward, the direction of the load torque
remains unchanged but the direction of the speed only reversed.
Any electric drive system operates in more than one quadrant. In fact, most versatile
systems operate in all the four quadrants. The converters of these systems must be
designed to allow the electric power to flow in both directions.
Modes of Operation:
• Operation in all four quadrants of the speed-torque plane can be achieved: motor
and generator (braking) operation in both rotational directions.
• The direction of the armature current is changed for reversing the torque
direction
An electric drive operates in three modes:
i. Steady state
ii. Acceleration including starting
iii. Deceleration including stopping
ωm
Tl
ωm1
1
ωm2
2
• The steady state operation is realized by adjusting the speed torque characteristic
such that the motor and load torques are equal at that speed. When the torque
opposes motion, the motor works as motor in quadrant I and III.
• The active load can reverse its sign and assist the motion in some cases like
lowering of loaded hoist. For such a case, the steady state can be obtained by
adding mechanical brake which will produce a torque in a direction oppose the
motion.
• Drive operates in quadrant II and IV depends on the direction of rotation.
• Drives where the motor runs at nearly fixed speed are known as constant speed
or single speed drives. Multi-speed drives are those which operate at
discrete speed settings.
• Drives needing step less change in speed and multispeed drives are called
variable speed drives.
• When a number of motors are fed from a common converter, or when a load is
driven by more than one motor, the drive is called as multi-motor drive.
• A variable speed drive is called constant torque drive if the drive’s maximum
torque capability does not change with a change in speed setting. The
corresponding mode of operation is called constant torque mode.
• It must be noted that the term ‘constant torque’ refers to maximum torque
capability of the drive and not to the actual output torque, which may vary from
no load to full load torque. Constant power drive and constant power mode are
defined in the same way.
• In ideal case, the motor speed should be remains constant as the load torque is
changed from no load to full load. But in practical case, the speed drops with the
increase in load torque. Quality of a speed control system is measured in terms of
speed regulation.
• If the open loop control fails to provide the desired speed regulation, drive is
operated as closed loop speed control system.
Feedback loops in an electrical drive may be provided to satisfy one or more of the
following requirements:
i. Protection
ii. Immediate Speed response
iii. Improvement in steady state accuracy
• This technique mainly used in battery operated vehicles, rail cars and electric
trains.
• Driver presses the accelerator to set torque reference T*. Because of feedback,
the actual torque T follows the reference T*.
• Speed feedback loop is present through the driver. By giving appropriate pressure
on the accelerator, driver adjusts the speed depending on traffic, road condition,
car condition etc.
3. Closed loop speed control:
+ Δω m Speed I*
Current
Converter Motor Load
ω Contoller + Controller
m
- - I
* ω Current
m Current
Limiter
Sensor
Speed
Sensor
Current
Limiter
• Above figure shows the widely used closed loop speed control method in electrical
drives. It consists of inner current loop and outer speed loop.
• Current loop controls the converter and motor currents to safe limit and hence
the torque. Inner current loop also reduces the effect on performance of any non-
linearity present in converter-motor system.
• An increase in speed reference ω m* produce a positive error Δω m. Speed error is
processed through a speed controller and applied to current limiter which
saturates even for a small speed corresponding to the maximum allowable
current.
• Drive accelerates at the maximum allowable current. When close to the desired
speed, limiter desaturates. Steady state is reached at the desired speed and at
current for which motor torque is equal to the load torque.
• A decrease in speed reference ω m* produce a negative speed error. Current
limiter saturates and sets current reference for inner current loop at a value
corresponding to maximum allowable current. Consequently, drive decelerates in
braking mode at maximum allowable current. When close to the required speed,
current limiter desaturates. The operation is transferred from braking to
motoring. Drive then settles at a desired speed and at a current for which motor
torque equal to the load torque.
• Current and speed controllers may consists of PI, PD or PID controller depending
on steady state accuracy and transient response requirements.
UNIT II CONVERTER / CHOPPER FED DC MOTOR DRIVE
Steady state and transient analysis of the single and three phase fully controlled
converter fed separately excited D.C motor drive – Continuous and discontinuous
conduction mode – Multiquadrant operation – Converter control – Chopper-fed D.C drive
– Steady-state analysis – Block diagram of closed loop dc drive.
(a)
(b)
Fig.1(a) shows the separately excited DC motor fed from fully controlled rectifier. The ac
input voltage is given by vs=Vmsinω t.
• When the armature current doesn’t flow continuously, the motor is said to
operate in discontinuous conduction. When the current flows continuously, the
conduction is said to be continuous.
Discontinuous Conduction:
• In this mode, the current starts flowing with the turn-on of thyristors Q1 and Q2 at
ω t=α . Motor connected to the source and its terminal voltage equals v s. The
current, which flows against both Vc and source voltage after ω t=π , falls to zero
at θ .
• Due to the absence of current Q1 and Q2 turn-off. Motor terminal voltage is now
equal to its induced voltage Vc. When thyristors Q3 and Q4 are fired at (π +α ),
next cycle of the motor terminal voltage vd starts.
• In a cycle of motor terminal voltage vd, the drive operates in two intervals:
di d
v d = Ri d + L + Vc = Vm sin ωt , for α ≤ ωt ≤ θ → (1)
dt
v d = Vc and id = 0 for θ ≤ ωt ≤ π + α → (2)
Vm V
id (ωt ) = sin(ωt − φ ) − c + K 1e −t / τ a for α ≤ ωt ≤ θ → (3)
Z R
where,
Z = R 2 + (ωL) 2 →( 4)
ωL L
φ = tan −1 →(5) and τa = ( Armature circuit time constant )
R R
Constant K1 can be evaluated subjecting eq.(3) to the initial condition id(α )=0.
Substituting value of K1 so obtained in Eq.(3) gives
id (ωt ) =
Vm
Z
[ ] V
[ ]
sin( ωt − φ ) − sin(α − φ )e −( ωt −α ) cot φ − c 1 − e −( ωt −α ) cot φ , for α ≤ ωt ≤ θ
R
→ ( 6)
The motor is initially assumed to be running light (and therefore with a very small
positive slip) as indicated by point A on the dotted torque– speed curve in Figure (a).
Two of the supply leads are then reversed, thereby reversing the direction of the field,
and bringing the mirror-image torque–speed curve shown by the solid line into play. The
slip of the motor immediately after reversal is approximately 2, as shown by point B on
the solid curve. The torque is thus negative, and the motor decelerates, the speed
passing through zero at point C and then rising in the reverse direction before settling at
point D, just below the synchronous speed.
The speed–time curve is shown in Figure (b). We can see that the deceleration
(i.e. the gradient of the speed–time graph) reaches a maximum as the motor passes
through the peak torque (pullout) point, but thereafter the final speed is approached
gradually, as the torque tapers down to point D.
Very rapid reversal is possible using plugging; for example a 1 kW motor will
typically reverse from full speed in under 1 s. But large cage motors can only be plugged
if the supply can withstand the very high currents involved, which are even larger than
when starting from rest.
Frequent plugging will also cause serious overheating, because each reversal
involves the ‘dumping’ of four times the stored kinetic energy as heat in the windings.
Plugging can also be used to stop the rotor quickly, but obviously it is then necessary to
disconnect the supply when the rotor comes to rest, otherwise it will run-up to speed in
reverse. A shaft-mounted reverse rotation detector is therefore used to trip out the
reverse contactor when the speed reaches zero.
Injection braking
This is the most widely used method of electrical braking. When the ‘stop’ button
is pressed, the 3-phase supply is interrupted, and a d.c. current is fed into the stator via
two of its terminals. The d.c. supply is usually obtained from a rectifier fed via a low-
voltage high-current transformer.
(c)
It is known that the speed of rotation of the air-gap field is directly proportional
to the supply frequency, so it should be clear that since d.c.is effectively zero frequency,
the air-gap field will be stationary. Also known that the rotor always tries to run at the
same speed as the field. So, if the field is stationary, and the rotor is not, a braking
torque will be exerted. A typical torque–speed curve for braking a cage motor is shown
in Figure (c), from which we see that the braking (negative) torque falls to zero as the
rotor comes to rest.
This is in line with what we would expect, since there will be induced currents in
the rotor (and hence torque) only when the rotor is ‘cutting’ the flux. As with plugging,
injection (or dynamic) braking is a dissipative process, all the kinetic energy being
turned into heat inside the motor.
•
Tr1
In stepped wave inverter, transistors are switched on in the sequence of their
numbers with a time difference of T/6 and each transistor is kept ON for duration
of T/2, where T is the time period of one cycle.
Frequency is varied by varying T and output voltage is varied by varying DC input
voltage.
• When the input is DC, a chopper circuit can be used between the supply and
inverter.
• When the input supply is AC, controlled rectifier converts AC to DC and feeds to
the inverter. A large electrolytic capacitor is connected in DC link to make inverter
Vd
operation independent of rectifier and to filter out harmonics in DC link voltage.
• The RMS value of the fundamental phase voltage,
2
V = Vd
π
The torque for a given speed can be calculated by considering only fundamental
component.
• Drawbacks of stepped wave inverter drives:
o Large harmonics in lower frequency operations
o Low frequency harmonics increases the motor losses at all speeds and
causing derating of the motor.
o Motor develops pulsating torques due to 5th, 7th, 11th, and 13th harmonics
which cause jerky motion of the rotor at low speeds.
o Harmonic content in motor current increases at low speeds. The machine
saturates at light loads at low speeds due to high V/f ratio. These two B
effects overheat the machine at low speeds, thus limiting lowest speed to
around 40% of base speed.
• The PWM inverter overcomes all the above drawbacks. And also no additional
Tr4
arrangement is required variation of DC voltage, hence inverter can be directly
connected when the supply is DC and through a diode rectifier when the supply is
AC.
• The fundamental component in the output phase voltage of PWM is
Vd
V =m
2 2
where m-Modulation index
Ld
iA
iA
Idc
0 ωt
π 2π
• Diodes D1-D6 and Capacitors C1-C6 provide commutation of thyristors T1-T6, which
are fired with a phase difference of 60o in sequence of their numbers.
• Inverter behaves as a current source due to the presence of large inductance DC
link.
• The fundamental component of motor phase current is
6
Is = I dc
π
• The torque is controlled by varying dc link current Idc by changing the value of Vr
for a given speed.
• The maximum value of dc output voltage of fully-controlled rectifier is chosen so
that the motor terminal voltage saturates at rated value.
• The major advantage of CSI is its reliability. In case of VSI, a commutation failure
will cause two devices in the same leg to conduct. This connects conducting
devices directly across the supply. Consequently, current through the devices
suddenly rises to dangerous values. Expensive high speed semiconductor fuses
are required to protect the devices.
• In CSI, conduction of two devices in the same leg does not lead to sudden rise of
current through them due to the presence of a large inductance L d. This allows
time for commutation to take place and normal operation to get restored in
subsequent cycles.
• As seen in figure, the motor current rise and fall are very fast. These rapid rise
and fall through the leakage inductance causes large voltage spikes. Therefore, a
motor with low leakage inductance is used.
• The commutation capacitances C1-C6 reduce the voltage spikes by reducing the
rate of rise and fall of the current. Large value of capacitors is required to
sufficiently reduce the voltage spikes. Large range of capacitors reduces the
frequency and hence the speed of the drive.
• Due to large value of capacitors and inductors, the CSI drive is expensive and has
more weight and volume.
Regenerative Braking and Multiquadrant operation:
• When inverter frequency is reduced to make synchronous speed less than motor
speed, machine works as a generator.
• Power flows from machine to DC link and DC link voltage Vr reverses. The power
supplied to DC link will be transferred to ac supply and regenerative braking will
take place. Thus, no additional equipment is required for regenerative braking of
CSI drive.
• Change of phase sequence of CSI will provide motoring and braking operations in
the reverse direction.
Ir
Id
0
π 2π ωt
• The AC voltage induced in the rotor circuit is rectified and given to the parallel
combination of the resistance R and the switching transistor Tr.
• The effective value of the resistance R can be changed by the duty ratio of the
transistor, which in turn varies the rotor circuit resistance.
• The inductance Ld is added to reduce the harmonics and discontinuity in the dc
link current Id.
• The rotor current is shown in fig without ripple. The rms rotor current will be
2
Ir = Id
3
• Resistance between A and B will be zero when transistor is ON and it will be R
when it is OFF. Therefore, the average value of resistance between the terminals
is given by
RAB=(1-δ )R
where δ is the duty ratio of the transistor.
• Power consumed by RAB is given by,
PAB = I d2 R AB = I d2 R (1 − δ )
PAB
Power consumed per phase is = 0.5 R(1 − δ ) I r2
3
The above equation suggests that the rotor circuit resistance per phase is
increased by 0.5 (1- δ ) R. Thus, total rotor circuit resistance per phase will now
be RrT=Rr+0.5 (1- δ ) R.
• The slip power is dissipated in the external resistance and leads to poor efficiency
of the drive.
• The phase controlled bridge1 with a firing angle less than 90 0 is allowed to
function as a controlled rectifier and bridge 2 with a firing angle more than 900 is
allowed to function as a line commutated inverter which offers subsynchronous
motor control.
• Near synchronous speed, slip frequency emfs are insufficient for natural
commutation of thyristors.
• The above figure shows the implementation of the constant V/f control strategy in
open loop.
• This type of variable speed drive is used in low performance applications where
precise speed control is not necessary.
• The frequency command fsn* is enforced in the inverter and corresponding DC link
voltage is controlled through the front end converter. The offset voltage, V on, is
added to the voltage proportional to the frequency, and they are multiplied by
2.22 to obtain the dc link voltage.
• Some problems associated with the open loop drive are listed below:
o The speed of the motor cannot be controlled precisely, because the rotor
speed will be less than the synchronous speed. Note that the stator
frequency, and hence the synchronous speed, is the only variable
controlled in this drive.
o The slip speed, being the difference between the synchronous and
electrical rotor speed cannot be maintained the rotor speed is not
measured in this drive scheme. This can lead to operation in the unstable
region of the torque speed characteristics.
o The effect discussed in the above point can make the stator currents
exceed rated current by many times, thus endangering the inverter-
converter combination.
The current is produces the rotor flux λ r and the torque Te.
if is the field producing component and iT is the torque producing component.
i.e, λ r α if → (4) and Teα λ r iT → (5)
Since the relative speed with respect to that of the rotor field is zero in steady state.
Therefore, if and iT have only dc components and are ideal for use as control variables;
the bandwidth of the computational control circuits will have no effect on the processing
of these dc signals.
Crucial to the implementation of vector control, then, is the acquiring of the
instantaneous rotor flux phasor position, θf . This field angle can be written as
θ f = θ r + θ sl → ( 6)
where θr is the rotor position and θsl is the slip angle.
The field angle can be written in terms of speeds as, θ f = ∫ (ωr + ωsl )dt = ∫ωs dt →( 7)
Vector control schemes are classified as,
i. Direct Vector Control – Field angle is calculated using terminal voltages and
currents.
ii. Indirect Vector Control – Field angle is obtained using rotor position
measurement and partial estimation with only machine parameters
Implementation of Vector Control in induction motors:
Vector control is the most popular control technique of AC induction motors. In special
reference frames, the expression for the electromagnetic torque of the smooth-air-gap
machine is similar to the expression for the torque of the separately excited DC machine.
In the case of induction machines, the control is usually performed in the reference
frame (d-q) attached to the rotor flux space vector. That’s why the implementation of
vector control requires information on the modulus and the space angle (position) of the
rotor flux space vector. The stator currents of the induction machine are separated into
flux- and torque-producing components by utilizing transformation to the d-q coordinate
system, whose direct axis (d) is aligned with the rotor flux space vector. That means
that the q-axis component of the rotor flux space vector is always zero:
d
ψ rq = 0 and ψ rq = 0
dt
Transformatio
Inverse Park
Torque
Speed Controller vsq,ln
n
Speed Contoller + vsd
Comman - vsα Space
d Vector
vsβ Modulatio 3φ AC
vsq
n
Motor
Transformatio
Flux vsd,ln
Transformatio
Flux
Forward Park
3 Phase
Forward
Controller
Clarke
Command Controlle
n
r
n
isd isα
Rotor
ia
Flux ib
Calculatio isβ
isq ic
n
3φ
Im
Speed
Sensor
The components isα and isβ, calculated with a Clarke transformation, are attached to the
stator reference frame α and β. In vector control, all quantities must be expressed in the
same reference frame. The stator reference frame is not suitable for the control process.
The space vector is is rotating at a rate equal to the angular frequency of the phase
currents. The components isα and isβ depend on time and speed. These components can
be transformed from the stator reference frame to the d-q reference frame rotating at
the same speed as the angular frequency of the phase currents. The isd and isq
components do not then depend on time and speed. The component isd is called the
direct axis component (the flux-producing component) and isq is called the quadrature
axis component (the torque-producing component). They are time invariant; flux and
torque control with them is easy.
Knowledge of the rotor flux space vector magnitude and position is key information for
AC induction motor vector control. With the rotor magnetic flux space vector, the
rotational coordinate system (d-q) can be established. There are several methods for
obtaining the rotor magnetic flux space vector. The flux model implemented here utilizes
monitored rotor speed and stator voltages and currents. It is calculated in the stationary
reference frame (α, β) attached to the stator. The error in the calculated value of the
rotor flux, influenced by the changes in temperature, is negligible for this rotor flux
model.
For purposes of the rotor flux-oriented vector control, the direct-axis stator current isd
(the rotor flux-producing component) and the quadrature axis stator current isq (the
torque producing component) must be controlled independently. However, the equations
of the stator voltage components are coupled. The direct axis component v sd also
depends on isd and the quadrature axis component vsq also depends on isq. The stator
voltage components vsd and vsq cannot be considered as decoupled control variables for
the rotor flux and electromagnetic torque. The stator currents isd and isq can only be
independently controlled (decoupled control) if the stator voltage
equations are decoupled and controlling the terminal voltages of the induction motor
indirectly controls the stator current components isd and isq.