LAKASA Marketino & Distribution

LAKASA Sediment lnterceptor

LAKASA Sediment lnterceptor is completed with a perforated bucket and able to act as an effective
strainer to avoid drain lines clogging by foreign solid particles. The perforated bucket should be
cleaned on daily basis or as frequent as possible to avoid overflow of solid waste and interrupting free
flow of wastewater in the drain lines.

The system must be of adequate size and design to intercept the incoming solid particles and also
taking into consideration the periodic cleaning schedule requirements. The sediment waste should be
cleaned as soon as it is filled up half full. lt can be daily or once every 3-4 days, depending on the
volume of sediment waste.

I nstallation method statement


1 . Inspect unit for defects / damages and make sure it rheets specified requirements (eg : model and
size).
2. DO NOT INSTALL INTERCEPTOR BACKWARDS. Install interceptor as close as possible to the
source to minimizes unprotected pipe.
3. Install interceptor sitting on floor, partially recessed or flush-to-floor, making sure there is enough
room to allow for easy maintenance of the unit. (Room for cover to be removed and sediment
bucket to be taken out for cleaning).
4. INTERCEPTOR MUST BE PLACED ON A FLAT, SOLID SURFACE TO SUPPORT THE
BOTTOM! When suspending interceptor from floor above, all units must be fully supported on
bottom with a flat surface strong enough to supporl the weight of the unit when full of
water/sediment waste. All units must be independently supported to avoid stress on fittings.
5. WHEN INSTALLING lN THE GROUND, Construct a solid manhole sump for housing the
interceptor. Manhole sump cover should normally be higher a bit the floor level OR construct a
drain surrounding the cover to channel away most rain water and prevent in from entering the
sump. The sump should also allocate four corner water exit at lowest possible 4 sides corners for
the in case splashed into rain water to escape and seep into the earth outside the sump.
FILL INTERCEPTOR WITH WATER AND INSTALL LID BEFORE BACK FILLING. lt is
recommended to use light sand for back fill. Be sure backfill is free of sharp stones and foreign
matter to avoid punctures. (DO NOT PUT SAND INTO INTEREPTOR!)
6. INTERCEPTOR filled with clean water until static water level and is ready for operation.

Schematic View

Dimensional Data

Model Pipe A B Gin G out Din D out E


Size (mm) (mm) (mm) (mm) (mm) (mm) (mm)
(mm)
LKS 9222 50 200 200 70 100 130 100 ZUU
LKS 9333 50 300 300 100 200 200 100 300
LKS 9434 75 400 400 '100 200 200 100 300
LKS 9545 100 500 500 110 250 290 150 400
LKS 9656 100 600 600 120 300 380 200 500
LKS 9767 '100 700 700 120 300 480 300 600
LKS 9878 100 800 800 130 350 570 350 700

Various dimensions is available upon request or to suit site requirement