You are on page 1of 13

Design of isolated square footing

Here b
Fck= 20 N/mm 2
colmsize= 400 *
fy= 500 N/mm 2

safe bearing capacity of soil = 100 kN/m2


depth of footing = 1.5
Axial load = 338 kn
Total weight on soil= 371.8 kn
area of footing required = 3.718 m2 =
Required length and breath 1.93 * 1.93 footing
provided footing size = 2.1 * 2.1
thus provided area = 4.41 m2
The net earth pressure acting upward due to factored load is
Pu= 115 kN/m2
0.12 N/sq.mm
where 1.5 is partial safety factor
Shear in one way action
the critical section is taken as distance d away from the face of column
l 0.85
Now effective depth required is MM 255.00
D depth MM 450 Depth is increased to provide sloped footing
d effective depth MM 382 (L)
Check for sloped part
Provide full depth of the footing slab upto distance of 500mm from the face of column and edge thickness of 300
Check for Bending Moment
Bending moment about an axis x-x passing through the face of column
= 87.24 knm

Now effective depth required is


d =
BM
0.138 * fck * b

= 122.69 mm OK

Now area of tension steel is given by

Area of reinforcement (Ast)

BM=
fyAst
0.87 fyAst * (d  )
fck  b
where ,
Bm = 87.24 knm
fy = 500
d= 382
fck = 20
b= 2.1 m
by solving Ast = 534 mm2
minimum reinforcement Ast= 962.64 mm2
design Ast= 962.64
Shear in two way action
The critical section is taken at a d/2 distance away from the face of the column
A2= 0.349
Now shear force Vu=
115[4.41-0.349281]
= 466.98269 kn
Nominal shear stress(τv) =
0.5171183 N/mm2
shear strength of M 20 concrete
τ'c = ks *τc

ks= 0.5+ βc
βc = longer side of column/shorter side of column
ks= 0.5+1 ks≤1
= 1.5
thus Ks = 1

thus τ'c =τc = 0 . 25 fck


1.118034
since nominal shear strength is less than shear shrenght of concrete the design is safe in

Load transfer from column to footing


Nominal bearing stress in column = 1.5*338*1000/(400*400)
= 3.16875 N/mm2

Allowable bearing stress = 0.45*√fck


= 9 N/mm2
now Excess load = -933000 N

Area of steel required As = -2785.07 mm2


Minimum Ast=0.5% of column area = 800 mm2
thus minimum area of steel for dowel bars =
Now
bar extended
Nos dia Ast
4 16 804.2496
4 16 804.2496
Available Ast for load transfer= 1608.499 mm2

thus no additional dowel bars are required to tranfer load


additional Ast = No dowel bars are needed

description of dowel bars


Nos dia Ast
6 25 2945.25
6 25 2945.25
total Ast= 5890.5 mm2
increase either nos or dia of dowel bars
Arrangement of bars for foundation slab
dia of bars used = 12 mm
NO of bars required = 9
spacing of reinforcement required = 233.3 mm c/c
spacing of reinforcement provided= 150.0 mm c/c
dia of bar used = 12
tension for compression
Development length = 582.5893 mm 358.9285714286
available L = 850 OK
d
400 mm

e thickness of 300

a=
b
=

oncrete the design is safe in two way shear

800 mm2
Design of isolated square footing
Here b
Fck= 20 N/mm 2
colmsize= 400 *
fy= 500 N/mm 2

safe bearing capacity of soil = 100 kN/m2


depth of footing = 1.5
Axial load = 493.33333 kn
Total weight on soil= 542.6667 kn
area of footing required = 5.426667 m2 =
Required length and breath 2.33 * 2.33 footing
provided footing size = 2.4 * 2.4
thus provided area = 5.76 m2
The net earth pressure acting upward due to factored load is
Pu= 129 kN/m2
0.13 N/sq.mm
where 1.5 is partial safety factor
Shear in one way action
the critical section is taken as distance d away from the face of column
lM 1
Now effective depth required is MM 317.07
D depth MM 500 Depth is increased to provide sloped footing
d effective depth MM 432 (L)
Check for sloped part
Provide full depth of the footing slab upto distance of 550mm from the face of column and edge thickness of 300
Check for Bending Moment
Bending moment about an axis x-x passing through the face of column
= 154.80 knm

Now effective depth required is


d =
BM
0.138 * fck * b
= 152.88 mm OK

Now area of tension steel is given by

Area of reinforcement (Ast)

BM=
fyAst
0.87 fyAst * (d  )
fck  b
where ,
Bm = 154.80 knm
fy = 500
d= 432
fck = 20
b= 2.4 m
by solving Ast = 841 mm2
minimum reinforcement Ast= 1244.16 mm2
design Ast= 1244.16
Shear in two way action
The critical section is taken at a d/2 distance away from the face of the column
A2= 0.379
Now shear force Vu=
129[5.76-0.379456]
= 694.09018 kn
Nominal shear stress(τv) =
0.6520658 N/mm2
shear strength of M 20 concrete
τ'c = ks *τc

ks= 0.5+ βc
βc = longer side of column/shorter side of column
ks= 0.5+1 ks≤1
= 1.5
thus Ks = 1

thus τ'c =τc = 0 . 25 fck


1.118034
since nominal shear strength is less than shear shrenght of concrete the design is safe in

Load transfer from column to footing


Nominal bearing stress in column = 1.5*493.333333333333*1000/(400*400)
= 4.625 N/mm2

Allowable bearing stress = 0.45*√fck


= 9 N/mm2
now Excess load = -700000 N

Area of steel required As = -2089.55 mm2


Minimum Ast=0.5% of column area = 800 mm2
thus minimum area of steel for dowel bars =
Now
bar extended
Nos dia Ast
4 16 804.2496
4 16 804.2496
Available Ast for load transfer= 1608.499 mm2

thus no additional dowel bars are required to tranfer load


additional Ast = No dowel bars are needed

description of dowel bars


Nos dia Ast
6 25 2945.25
6 25 2945.25
total Ast= 5890.5 mm2
increase either nos or dia of dowel bars
Arrangement of bars for foundation slab
dia of bars used = 12 mm
NO of bars required = 12
spacing of reinforcement required = 200.0 mm c/c
spacing of reinforcement provided= 150.0 mm c/c
dia of bar used = 12
tension for compression
Development length = 582.5893 mm 358.9285714286
available L = 1000 OK
d
400 mm

e thickness of 300

a=
b
=

oncrete the design is safe in two way shear

1000/(400*400)

800 mm2
Ast% M15 M20 M25 M30
0.15 0.28 0.28 0.29 0.29
0.15 0.25 0.28 0.35 0.28 0.36 0.29 0.36 0.29 0.37
0.25 0.5 0.35 0.46 0.36 0.48 0.36 0.49 0.37 0.5
0.5 0.75 0.46 0.54 0.48 0.56 0.49 0.57 0.5 0.59
0.75 1 0.54 0.6 0.56 0.62 0.57 0.64 0.59 0.66
1 1.25 0.6 0.64 0.62 0.67 0.64 0.7 0.66 0.71
1.25 1.5 0.64 0.68 0.67 0.72 0.7 0.74 0.71 0.76
1.5 1.75 0.68 0.71 0.72 0.75 0.74 0.78 0.76 0.8
1.75 2 0.71 0.71 0.75 0.79 0.78 0.82 0.8 0.84
2 2.25 0.71 0.71 0.79 0.81 0.82 0.85 0.84 0.88
2.25 2.5 0.71 0.71 0.81 0.82 0.85 0.88 0.88 0.91
2.5 2.75 0.71 0.71 0.82 0.82 0.88 0.9 0.91 0.94
2.75 3 0.71 0.71 0.82 0.82 0.9 0.92 0.94 0.96
3 0.71 0.82 0.92 0.96

Required
M15 M20 M25 M30
p Tc Tc Tc Tc
% N/mm2 N/mm2 N/mm2 N/mm2
#REF! #REF! #REF! #REF! #REF!
#REF! #REF! #REF! #REF! #REF!
#REF! #REF! #REF! #REF! #REF!

grade of concrete M15 M20 M25 M30


design bond strength 1.92 2.24 2.4 2.38

tbd= 2.24
Design of isolated footing
Net safe bearing capacity = 100 kn/m2
column size = 400 * 400 mm
fy = 500
fck= 20

Axial load (factored) footing size depth(mm) check in one way check in two way dowel bars Slab reinforcement
factored 1202 Min (m) Provided min provided shear shear bar dia spacing
unfactored 882 #REF! 2.3 #REF! 550 Err:504 Err:504 Err:504 12 #REF!
300
percentage of steel development length
#REF! % check for tension check for compression
dia length (L)
12 Err:504 Err:504 Err:504
mmc/c