PRESS (KSC) TEMP( C) ENTHALPY HEAT THERMAL

(KJ)/KG GAIN(KJ/HR) UNIT


(MWt)

FEED WATER
ECO I/L 169.28 242.98 1053.47 352230427.5 97.8241771
ECO O/L 169.28 340.87 1593.08

WATER WALL HEAT PICKUP


WW I/L 169.28 340.87 1593.08 606437387.5 168.424513
WW O/L 165.00 342.09 2522.13

SUPER HEATER I
SUPER I I/L 165.00 342.09 2522.13 280166278 77.8099603
SUPER O/L 162.04 414.49 3014.86

SUPER HEATER II
SUPER I I/L 161.53 377.13 2839.87 214205612.4 59.4908506
SUPER O/L 159.59 464.2 3193.73

SUPER HEATER III


SUPER I I/L 159.18 433.45 3092.42 207622203.6 57.6624551
SUPER O/L 157.65 536.32 3406.3

REHEATER I
REHEATER I/L 37.22 338.81 3075.3 156034543.3 43.3351284
REHEATER O/L 36.61 453.65 3344.99

REHEATER II
REHEATER I/L 36.30 435.19 3303.36 132900662.4 36.9102068
REHEATER O/L 35.49 534.92 3529.52

AIRHEATER CV O2
MASS OF AIR/KG FUEL 4.82752 9835 0.0498
ASH
MASS OF GF/KG FUEL 5.73671 0.1009
SP.HEAT (KJ/KGC)
FUEL MASS I/L TEMP
HEAT GIVEN BY FG 199433778 196900 5.73671 1.004832 322.51

199433777.57764 55.3883017

SP.HEAT (KJ/KGC)
HEAT LOSS TO ATM FUEL MASS I/L TEMP
130867421 196900 5.73671 1.004832 146.8
130867421.061419 36.3455192
CUMM
THERM
UNIT

541.457292

O/L TEMP DT
146.8 175.71

596.845593

O/L TEMP DT
31.5 115.3
633.191113
TURBINE HEAT RATE CALCUATION UNIT DATE

Details PARAM Calculation

Main steam flow (m22) 641.20400 m23= 641.2040

Auxilary steam flow (m3) 0.00000 t74= 528.1855

CR Steam flow (m24) 607.15100 p33= 141.5136

RH atm Spray flow (m5) 31.70500 p52= 142.8436

Power output (n1) 210.23100 p63= 163.9999

HPT I/L steam pr. (p9) L 141.51360 p36= 36.1213

HPT I/L steam pr (p10) R 141.51360 p56= 37.4513

HPT exh. Steam pressure (p11) 38.83840 p111 40.1684

IPT I/L steam pr. (p16) L 36.12130 p31= 70.0000

IPT I/L steam pr. (p17) R 36.12130 p64 = 71.3300

FW pressure bef. Eco (p30) 162.66990 q5= 435188270.9910

HPT I/L steam temp (t8) 528.18550 Turbine HR 2070.05 Kcal/Kwh

HPT I/L steam temp (t9) 528.18550

HPT EXH steam temp (t10) 346.34930 CORRECTION FACT 0.96224

IPT I/L steam temp (t17) 525.73330

FW temp bef. Eco (t47) 245.58930

RH attm spray water temp (t48) 167.27280

Atm Pressure (p1) 1.33000 FINAL HRATE 1991.883032847

h2=limit(t74,p52); 528.1855 142.8436 812.61000 Guarantee HR 1998.9

h32=limit(t47,p63); 245.5893 163.9999 256.46500 deviation

h7=limit(t17,p56); 525.7333 37.4513 837.90300 RH spray flow -7.02

h3=limit(t10,p111); 346.3493 40.1684 738.13700

h33=limit(t48,p64); 167.2728 71.33 170.01400

1991.87529

2271.482602118
2571.772602118 1.1322
aging

2055.05 24.2195621511

2005.540614

1977.44943

correction enthalpy(h3)
correction enthalpy(h33)

219
5
4