Vibration level on the turbine unit at all measurement points found to acceptable as it is
evaluated with practice level of vibration limit for Ruston TB5000, and the compressor part is
evaluated with ISO 10816-8 as below:
Though, it doesn’t show any abnormality based on the spectral data as it is predominantly
by 1xPT speed and the amplitude ratio is not much different when compared to vibration level on
the vertical direction on the same point.
Overall vibration level at all measurement points on this unit are tabulated as below:
POINT POINT CURRENT REF ABS. % ALR
ID DESCRIPTION VALUE VALUE UNITS DELTA DEV. SYM
----- ----------------------------- ------- ----- ------- ------- ---- ---