You are on page 1of 2

LANDMARK STRUCTURAL ENGINEERS S2016.03.

1300

SHEET NO.
13 Ensign House, Admirals Way, Canary Wharf, E14 9XQ TEL: 020 3150 0505
DATE
07.09.2016
14 WOODLANDS DRIVE, ENGINEER
WC
STEEL BEAM - SPREADER PLATES
LONDON SE10 9XD CHECKED

SPREADER PLATE CHECK MASONRY BEARING CHECK

UN- STEEL PLATE MASONRY


BEARING UDL (INCL. MMax sMax nMax STRESS
FACTORED YIELD SHEAR BEARING BEARING
BEAM WIDTH t L W sY PLATE WEIGHT) BENEATH THE
REACTION (N.mm) (MPa) (MPa) CHECK CHECK STRENGTH CHECK
(mm) (mm) (mm) (mm) (MPa) (N/mm) PLATE (MPa)
D+L (kN) (MPa)

SB01 150 16.00 20 400 100 355 60.23 4.71E+05 70.59 3.00 OK OK 0.42 0.40 OK
SB02 150 12.90 20 400 100 355 48.61 3.80E+05 56.96 2.42 OK OK 0.42 0.32 OK
SB04 150 25.00 20 400 200 355 94.22 7.36E+05 55.21 4.69 OK OK 0.42 0.31 OK
SB05 150 16.00 20 400 100 355 60.23 4.71E+05 70.59 3.00 OK OK 0.42 0.40 OK
SB07 150 25.20 20 700 100 355 54.23 2.05E+06 307.61 2.70 OK OK 0.42 0.36 OK
SB08 150 28.50 20 700 100 355 61.31 2.32E+06 347.72 3.05 OK OK 0.42 0.41 OK
SB08 150 21.00 20 600 100 355 52.73 1.33E+06 200.22 2.63 OK OK 0.42 0.35 OK

SPREADER BEAM CHECK 178x102x19 U.B. MASONRY BEARING CHECK

UN- BEAM SPECIFICATIONS UDL (INCL. MASONRY


BEARING MMax sMax STRESS
FACTORED PLATE YIELD BEARING BEARING
BEAM WIDTH I S A L W sY BENEATH THE
REACTION WEIGHT) (N.mm) (MPa) CHECK STRENGTH CHECK
(mm) (mm4) (mm3) (mm2) (mm) (mm) (MPa) PLATE (MPa)
D+L (kN) (N/mm) (MPa)

SB07 152 43.00 1.36E+07 171200 730000 700 102 355 177.55 6.66E+06 38.93 OK 0.63 0.60 OK
3.1300