PSC door

4.7502 KN/m BM and SF Calculation

1) wind load

contributory length 2.639


heigth of pannel 1.8
wind pressure 1
1.8m 7.917 KN
wind udl 4.7502
BM 7.695324
0.7m SF 8.55036

combined BM 13.23722
combined SF 16.46736

Bolt stressed

1) BM

500mm dis from axis 97.5


no. of bolts 4

195mm Tension in bolts 33.9416

Bolt Capacity
195mm diameter 16 mm
fu 800 N/mm2
fy 640 N/mm2
1) Tension

capacity 90.28731

0.144556 < 1
SAFE
2) crowd load

contributory length 2.639 m


m heigth of pannel 1.8 m
m crowd load 3 KN/m
KN/m crowd load 7.917 KN

point of application 1.1 m (from top)


KN.m 0.7 m (from bottom)
KN
BM 5.5419 KN.m
SF 7.917 KN

KN.m
KN

2) SF

mm
no. of bolts 4

KN.mm Shear force in bolts 4.11684 KN

8.8 grade

2) SF

KN capacity 72.39917 KN