You are on page 1of 6

Section Depth 600 bar spacing 100

f'c 30 Moment 500


concrete cover 40 Shear 200
section width 1000
fy 420
Es 200000
b 1000
bar dia 22

1 Input data

Section Depth (mm) 600


Compressive Strength of Concrete f'c (Mpa) 30
Stressed Characteristics of Member αcr 2.1
Concrete cover c (mm) 40
section width b (mm) 1000
Unit weight of concrete (KN) 24

2 Basic info

Design value of concrete compressive strength f cd (Mpa) 20


Coefficient α1 1
Mean axial tensile stregth of concrete f ctm (Mpa) 2.9
Design yield strength of reinforcement f yd (Mpa) 365.21739
Limit compressive strain of normal section in concrete ξcu 0.0033

3 Tension bar calculation

Design bending moment (KN-m) 500


Stress block depth x 47.600957
Chcek x≤Ϩb*h0 OK
Min required tension bar As min (sq mm) 1307.7964
Final minimum tension bar As min 2266.7123

4 Check on Shear

Design Shear Force V (kN) 200


Section type Plate
Stirrup Spacing Ss (mm) 150
Yield strength of stirrup bar fyv (Mpa) 420
Influence coefficeint of concrete strength βc 1
Check V≤Vmax OK
Adopted h0 for βh 800
Shear capacity Vr (KN) 742.98
5 Check for punching shear (Round pile/column)

Design value of punching shear F1 (KN) 1300


Convert circuler section to rectangular b p 400
Influence co-eff of the acting area shap for local load/concentrated reaction η1 1
Influence co-eff = peremeter of critical section/effective depth of section of slab 1.2231296
Factor η 1
Check Fp>F1 OK

6 Check on crack

Moment in SLS Ms (KN-m) 340


stress of longitudinal steel reinforcement in concrete member σsk 187.26304
Nonuniform co-eff for strain of tensile steel reinforcement between cracks ψ 0.3055889
Active effective depth c (mm) (20≤c≤65) 40
Max. width of crack ωmax (mm) 0.1291258

7 Design for Shrinkage

Min Reinforcement provided for shrinkage A s min 600


Reinforcement Dia d 22
Inpute value
Inpute value (Later will be automoted)
Auto Calcualte

Yield strength of reinforcement fy (MPa)


Modulsu of Elasticity of Steel Es (Mpa)
Relative cohesion coefficient of longitudinal steel reinforcement in tension zone v
Tension bar diameter d (mm)
Bar cross section area (sq mm)
Charecteristics value of concrete compressive strength f ck

Modulus of eleasticity of concrete Ec (Mpa)


Effective depth of the section h0
Design tensile strength of concrete f ctd (Mpa)
co-efficient β
Relative depth of limiting compression zone Ϩb

Bar spacing s (mm)


Tension bar adapted As (sq mm)
Required tension bar As (sq mm)

Check Adopted³Required

Stirrups dia (mm)


Stirrups leg nos n
h0/b
Design yield strength of stirrup fyvd (Mpa)
Design value of max. shear on inclined section member V max (KN)

Sectional depth influencial coefficient βh


Check Vr³V
Pile/Column Dia dp (mm)
Ratio for the long side to the short side βs
Influence co-eff of the column type in slab-column structure αs
Perimeter of critical section Um (mm)
Punching shear resistance Fp (KN)

Ratio for steel in tensile steel reinforcement ρte


Equivalent dia of longitudinal steel in tension zone d eq

Maximum allowable width (mm)


Check ωmax≤ωlim

Reinforcement Spacing S
Check As ³ As min
420
200000
1
22
380.1327
23.4

28335.45
549
1.933333
0.8
0.515013

100
3801.327
2266.712

OK

10
4
0.549
365.2174
2745

1.098701
OK
500
2
20
3796
3098.723

0.012671
22

0.2
OK

100
OK