You are on page 1of 12

SINGLE-SPLIT PACKAGED

AIR CONDITIONERS
2017 / 2018

Global Website: aircon.panasonic.com

Do not add or replace refrigerant other than


the specified type. Manufacturer is not Authorised Dealer
responsible for the damage and deterioration
in safety due to usage of other refrigerant.

• Specifications are subject to change without prior notice


for further improvement.
• The contents of this catalogue are effective as of
March 2017.
• Due to printing considerations, the actual colours may vary
slightly from those shown.
• All graphics are provided merely for the purpose of
illustrating a point.

PAC-NONINVERTER-ID APR 2017


Introduction

Create an Environment that Benefits CONTENTS

Your Business
Introduction .......................................... 2-3
Model Line-Up ..................................... 4-5

Feature Highlight
Optimum Room Temperature, Better Work Performance 4-WAY CASSETTE ................... 6-7
Air Purification ..................................... 8-9
A considerable portion of our lives is spent at the workplace. So it goes without Flexible Installation .......................... 10-11
saying that a pleasant environment boosts both morale and productivity. The fact Remote Controller ............................ 12-13
that people spend so much time in these places makes it all the more important
to provide clean air and a comfortable temperature. To help you maintain that Specifications
competitive edge, Panasonic supports your business by air conditioning the 4-WAY CASSETTE ............... 14-15
locations that are so essential to daily activities. CEILING ............................................ 16-17
DUCTED ............................................ 18-19

Outdoor Units
Dimensions ....................................... 20-21

4-Way Cassette Flexible Installation

What’s new

Provides a neat fit in the ceiling to match modern nanoe™ X containing plenty of OH radicals that Panasonic outdoor units are built to be compact with
decor, and uniform cooling throughout the room, Inhibits bacteria and virus, deodorizes unpleasant versatile piping and draining methods as well as
plus easy installation. odours and keeps room air clean and fresh. side-by-side installation capabilities.

2 3
Model Line-Up

MODEL LINE-UP 4-WAY CASSETTE CEILING DUCTED

PANASONIC PACKAGED AIR CONDITIONERS


ARE THE IDEAL AIR CONDITIONING SOLUTIONS FOR
OFFICES, EDUCATIONAL INSTITUTIONS,
RESTAURANTS AND RETAIL STORES. The 4-way direction airflow released Providing outstanding energy-saving Offering remarkable overall cooling
through four vanes provides wide and performance, comfort and coverage of the entire building,
Panasonic provides high performance air conditioning systems even cooling. long-distance air flow distribution, Ducted types are suitable for
that extend from homes to businesses. These products comply with stringent environmental these units are perfect for retail stores premises with concealed or false
requirements and advanced building standards in the modern commercial environment. and schools. ceilings such as business centres.

Capacity (Btu/h) 18,500 22,500-23,000 25,000 28,000 30,000 36,000 42,600 42,500-45,000 48,500 54,000

4-WAY CASSETTE
P.14-15
S-18PU1H5 S-22PU1H5 S-25PU1H5 S-28PU1H5 S-30PU1H5 S-40PU1H5 S-45PU1H5 S-50PU1H5

CEILING
P.16-17 S-22PT1H5 S-28PT1H5 S-35PT1H5 S-45PT1H5 S-55PT1H5

DUCTED
P.18-19 S-22PF1H5 S-28PF1H5 S-35PF1H5 S-45PF1H5 S-55PF1H5

OUTDOOR U-30PV1P5
UNITS
P.20-21 U-18PV1P5 U-22PV1P5 U-25PV1P5 U-28PV1P5 U-35PV1P8 U-40PV1P8 U-45PV1P8 U-50PV1P8 U-55PV1P8

U-30PV1P8

*3-Phase

4 5
4-WAY CASSETTE
4-Way Cassette

Wide Flap
Adding a sub flap and widening the main flap have Conventional New Model
reduced turbulence and increased airflow.
Also, the wider angle jetting port allows the airflow
to reach as far as five meters. Width 48mm Width 70mm

Previous flap New flap


Conventional New Model

4.5m 5m
Sub Flap

Airflow turbulence Airflow turbulence


is generated is reduced

360° Wide & Comfortable Airflow Ample airflow: 33 m3/min


Industry’s leading in the
Air coming out of the centre of the discharge 45PU class.
outlets travels farther.
Air is discharged across a wide area from the
four sides of the unit. The curves on the room
temperature distribution graph expand gently
out through 360° in a circle centred on the
Provides a neat fit in the ceiling to indoor unit.
match modern decor, and uniform
cooling throughout the room, plus easy
installation.
360° Wide

Temperature distribution by thermograph


(cooling operation)
1m
Simulation conditions:

Powerful Airflow
45PU 4-way ceiling-mounted cassette type in cooling mode/
Floor area of 225 m2/ Ceiling height of 3 m

The Twisted 3D Blade Fan with compact


design can increases airflow.

Flat Horizontal Design


Panasonic believes that one of the most
Conventional important elements of design is that it doesn't
interfere with the overall room interior. The flat
horizontal design of the 4-way Cassette achieves
an elegant, yet simple form. This design allows
it to protrude only 33.5 mm from the ceiling,
to blend naturally into a variety of interiors,
490 including offices and restaurants.

New Model
Fast Exposed Area 33.5mm

Cooling Easy Installation Design


Twisted With conventional models, it was difficult
485 3D Blade to use tools without damaging the interior.
This has been redesigned for easier
installation. Too narrow to use the tool Easy to use the tool

6 7
Air Purification
nanoe™ X

Invisible Air Contaminants are Suppressed


*1 *2 *3 *4 *5 *6 *7 *8
Pollen
(allergens) Mold Bacteria Viruses Odors

Odors are suppressed

Allergens are suppressed

1 2 3 1 2 3
nanoe™ particles OH radicals OH radicals
Odors are nanoe™ particles Allergens are
reach odors deep decompose degenerate
eliminated precisely reach suppressed
inside fabrics odor-causing allergen proteins
allergens
substances

nanoe™ X are nano-sized electrostatic


atomized water particles with 10 times
the OH radicals of nanoe™ Corona discharge Multi-Leader discharge
(Optional)
Generation zone Generation zone
CZ-CNEXU1 (nanoe™ X Kit) and CZ-KNELU1 (Corner Panel) of OH radicals: Small of OH radicals: Large
are required for 4-Way Cassette. Developed nanoe™X device uses a counter electrode
with four pins; and Multi-Leader Discharge that sends Discharge - O3 --OH-OH
- -OH - -OH-
types
-OH

intensive discharges toward the pin tips.


-OH -OH
O3 O3

Counter Counter
This expands the generation zone of electron-dense
What’s nanoe™ ?
electrode electrode
Generation Generation
OH radicals, thus increasing the amount of OH Atomization zone of Atomization zone of
electrode OH radicals electrode OH radicals
radicals by a factor of 10 times.
nanoe™ is a system that uses fine particle ions generated from moisture in the Radical
amount 1x 10x
air to form tiny particles from electrically charged water molecules. Filled with Ozone
amount 1x 1x
OH radicals, these water capsules suppress the activity of pollen (allergens) in
the air, and help to eliminate odors.

nanoe™ Airflow at a Comfortable


Generation Principle: Moisture in the air is activated Temperature
• While working, you enjoy cooling at a comfortable
temperature, and a fresh breeze.
1 2 3
Dew condensation is High voltage is applied to nanoe™ particles are
collected on the pin tip the water generated • After work, when everyone is gone, ventilating
operation continues to provide the nanoe™ effect.
• You can start work each day in a room filled with
refreshing air.

*1 Pollen (Allergens) [Effectiveness]: 88% [Testing Institute]: Panasonic Research Center [Test Report No]: BAA33-130402-F01 [Result]: 88% of deactivation after 8-hour nanoe™ operation.
*2 Mould [Effectiveness]: Inhibit Mould Growth [Testing Institute]: Japan Food Research Laboratories [Test Report No]: 13044083002-01 [Result]: The growth of the subject was inhibited after 8-hour nanoe™ operation.
*3 Bacteria [Effectiveness]: 99% [Testing Institute]: Kitasato Research Center for Environmental Science [Test Report No]: KRCES-Env. Test Report 24_0301_1 [Result]: 99% of deactivation after 4-hour nanoe™ operation.
*4 Bacteria [Effectiveness]: 99% [Testing Institute]: Japan Food Research Laboratories [Test Report No]: 13044083002-01 [Result]: The growth of the subject was inhibited after 8-hour nanoe™ operation.
*5 Viruses [Effectiveness]: 99% [Testing Institute]: Kitasato Research Center for Environmental Science [Test Report No]: KRCES-Env. Test Report 24_0300_1 [Result]: 99% of deactivation after 6-hour nanoe™ operation.
*6 Viruses [Effectiveness]: 99% [Testing Institute]: Japan Food Research Laboratories [Test Report No]: 13001265005-01 [Result]: 99% of deactivation after 8-hour nanoe™ operation.
8 *7 Odors [Effectiveness]: Decrease by 1.2 level [Testing Institute]: Panasonic Research Center [Test Report No]: BAA33-130125-D01 [Result]: Decrease in odour intensity by 1.2 level after 2 hour of operation. *8 Odors [Effectiveness]: Decrease by 1.7 level [Testing Institute]: Gunma Research Center [Test Report No]: No. 27055 [Result]: Decrease in odour intensity by 0.7 level after 2 hour of operation. 9
Flexible Installation
Flexible Installation

EER New Model


High Efficiency 13%UP
Conventional
The performance of our previous 2-fan models is
now achieved by 1-fan models. The Coefficient of
Performance has been greatly improved to reduce
power consumption. EER
EER 2.95
2.55 (Avg.)
(Avg.)

Long Piping
Piping can be extended up to 30m
Max.
without additional gas charging, 50m* Pipe length
and up to 50m with additional
gas charging. By giving you more Max.
flexibility in positioning the outdoor 30m Height difference
unit, this gives you a wider range
of installation options.
H1170 × W900 × D320
*For 36-54k Btu/h model.
Space Saving Outdoor Unit
Panasonic's ingeniously designed 174 mm
outdoor units are compact in size to fit
Shorter BTU 18.5-25k 28-30k 36-54k
into any space and layout. Its smaller Refrigerant Charge less Max. Pipe Length 30 m 45 m 50 m
size makes it easy to install even in Up to 30m
limited spaces. Flexibility in piping
Max. Chargeless Length # 7.5 m 7.5 m 30 m
No additional gas charging is needed up to 30m.
allows more freedom in installation Installation is easy and hassle-free. Max. Height Difference 20 m 25 m 30 m
leading to a reduced installation costs. # Additional gas is required when pipe length is extended.
*For 36-54k Btu/h model.

Can be installed in the


limited space
Flexible 4-way Piping Flexible
Piping can be routed in any of four directions. 4-Way piping
996mm
Supports for
U-35PV1P8
U-40PV1P8
U-45PV1P8
U-50PV1P8
U-55PV1P8

Easy Installation
& Service Maintenance
The PCB inside the outdoor unit have been removed.
980mm 370mm It’s easy installation and service maintenance.

U-35PV1P8 Supports for


U-40PV1P8 U-18PV1P5 U-28PV1P5
174 mm U-45PV1P8 U-22PV1P5
U-25PV1P5
U-30PV1P5
U-30PV1P8
U-50PV1P8
Shorter
10 11
Remote Controller
Remote Controller

Weekly Timer (For All Models)


1.Timer can be set for each day of the week.
2.Can be pre-set with: •Max. 6 settings/day •42 settings/week.
3.The temperature can also be programmed for optimal comfort.

Pre-sets for different conditions Setting the timer


Businesses with varying Can be set to switch off

1
Businesses with regular off days
visitor flows at different timings automatically

Example: Example: Example: Select


Precise Control, Easy Comfort Saturday afternoon – CLOSED
Sunday - CLOSED
Lunchtime - More visitors,
lower temperature
Avoid power wastage even if
users forget to turn it off
DAY

(weekdays)
Panasonic Packaged Series Remote Controllers
are designed with user comfort in mind. Multiple Mon-Fri On 9:00, Off 18:00
Sat On 9:00, Off 12:00
Daily Settings
On 12:00 23°C
Mon-Fri
Off 20:00
2
Enter
settings are available so airflow and air quality Sun Not set On 14:00 28°C TIME

can be regulated according to preferences. Users


Timer settings can be Timing & temperature can Timer can be set for simple *Simple Timer Mode
can also opt for a wired remote controller equipped differentevery day of the week. be set simultaneously. shut-off operation. Using the 24-Hour ON/OFF timer, ON/OFF
operations can be set at the same time daily.
with high-performance timer.

Odour Wash Economy Mode Ventilation


(For All Models) (For All Models) (For All Models)
Reduces unpleasant odours Saves up to 20%* energy. The air When an external device such as a
caused by the air conditioner’s conditioner determines the stable ventilator is connected to the indoor
heat exchanger. condition and moderately shifts unit, the ventilator’s ON/OFF
Wired Remote Controller Wireless Remote Controller Wireless Controller the set temperature in 0.5-degree operations can be controlled by the
Odour Removing steps to regulate the energy- wired remote controller. You can
CZ-RD513C (For All Models) CZ-RL013U (For 4-Way Cassette Type) Receiver ONE PUSH
CZ-RL013T (For Ceiling Type) (For 4-Way Cassette Type) saving operation (max. 2 degrees). select from either link-ventilation
or independent-ventilation.
Temperature

(digital connection)
0.5˚C

2˚C 0.5˚C

0.5˚C

Setting 0.5˚C ON
temperature
Cooling

30min 30min 30min 30min Time


2 hours
ON

When air from the outlet smells musty, moisture in the *During operating in the cooling mode at the remote
heat exchanger washes away odours. control set temperature of 25 under the cooling
standard temperature conditions. Ventilators are not included in the product line-up.
Can be operated with the wireless remote controller. OPTIONAL : Printed circuit board (Interface Adapter for
Can be operated with the wireless remote controller. External Signals CZ-TA31P*) is needed.

*Printed Circuit Board


Settings can be regulated with 3 control options: CZ-TA31P
•By connecting to the indoor unit, a separately sold
ventilator can be controlled.

Group Control by a single Separate Control by Common Control by Both Multi Comfort Air Control (For Cassette Models) •Remote operation control of the indoor unit is enabled
(ON/OFF control).
remote controller Twin Remote Controllers Wired and Wireless Remote New control technology gives users a 0˚
10˚ 10˚
0˚ •The condition of the indoor unit (malfunctions,
operating status) can be output externally.
Controllers wide selection of more specific airflow
20˚
30˚
40˚
20˚
30˚
40˚
•Control in linkage to a total heat exchanger or similar
devices is possible.
50˚ 50˚

Receptor unit angles. Choose from the 3-Pattern Auto 60˚


70˚
AUTO 1
35˚– 55˚
60˚
70˚
AUTO 2
35˚– 47˚

Swings to avoid direct exposure to cool air



10˚
20˚

Indoor units Indoor (total 50-degree swing width). 30˚


40˚
50˚

Remote-side units 60˚


70˚
AUTO 3
43˚– 55˚
remote controller Wireless
Remote-side Local-side
remote
remote controller remote controller Wired remote controller
(either wired or wireless) controller
Even buildings with additional
• All indoor units operate in the • Each indoor unit can be operated • The last button pressed has RAC Interface Adapter air conditioning systems can be central controlled
same mode. by either of the two remote priority (using either wired or
Using RAC Interface Adapter along with FSV-EX Series Central
controllers. wireless remote controllers). Controller
the existing VRF units, a centralized
• Apart from the timer setting time,
control system is possible. Temperature
the displays for the two remote
management can be achieved by
controllers are identical.
expanding low-to-mid sizes together.
• The last button pressed has priority CZ-CAPRA1
(The main or slave attribute is set H120×W70×D32,5mm
with the remote controller).
12 13
4-WAY CASSETTE
Indoor Unit | 4-Way Cassette

Model No.
S-18PU1H5 S-30PU1H5 Dimensions
S-22PU1H5 S-40PU1H5
S-25PU1H5 S-45PU1H5 X
S-28PU1H5 S-50PU1H5
890~910
(Ceiling opening dimensions)
1 Air intake
780 XX
TECHNICAL FOCUS (Suspension bolt pitch) 2 Discharge outlet

unit: mm 3 Refrigerant tubing (liquid tube)

(Ceiling opening dimensions)


• Compact design 7 4 Refrigerant tubing (gas tube)

(Suspension bolt pitch)


• Low sound levels 5 Drain tube connection port VP25 (outer dia. ø32)

890~910
700
• DC fan motor for increased efficiency 6 Power supply port
7 Suspension bolt hole (4-12×30 elongated hole)

(390)
(410)
• Powerful drain pump gives 850 mm lift A 18.5-30 kBtu/h

418
B 37-48.5 kBtu/h
• Lightweight design <Filter dimension> 520 x 520 x 15
• Optional nanoe™ X (CZ-CNEXU1) 840
5 340 3 4
A 256
480 840
2
B 319
272 51

124
184

50

192
90

32
127
33.5
Less than 35 Less than 35 6
2 950
A 124
515 (Air intake)
B 187

90
Less than 300
2

134
2

515 (Air intake)


Less than 666
Less than 850

950
480
1 View X

Over 18
Accessories

Over 30
122
Selectable 2
Panel Remote Controller Optional nanoe™X Kit Coner Panel View XX
Drain up

* Adjust the suspension bolt length so that the gap from the lower ceiling surface becomes 30 mm or more (18 mm or more from the lower surface of
the body) as shown in the figure. When the suspension bolt length is long, it hits the ceiling panel and installation is not possible.

CZ-KPU3 CZ-RD513C CZ-RL013U CZ-CNEXU1 CZ-KNELU1

Capacity ( Btu/h ) 18,500 23,000 25,000 28,000 30,000 30,000 42,600 45,000 48,500
Power Source V/Phase Hz 220 V, 1Ø Phase - 50 Hz 380 V, 3Ø Phase - 50 Hz
Indoor S-18PU1H5 S-22PU1H5 S-25PU1H5 S-28PU1H5 S-30PU1H5 S-30PU1H5 S-40PU1H5 S-45PU1H5 S-50PU1H5
Outdoor U-18PV1P5 U-22PV1P5 U-25PV1P5 U-28PV1P5 U-30PV1P5 U-30PV1P8 U-40PV1P8 U-45PV1P8 U-50PV1P8
Panel CZ-KPU3 CZ-KPU3 CZ-KPU3 CZ-KPU3 CZ-KPU3 CZ-KPU3 CZ-KPU3 CZ-KPU3 CZ-KPU3
kW 5.42 6.74 7.33 8.21 8.79 8.79 12.49 13.19 14.22
Cooling Capacity: Rated
Btu/h 18,500 23,000 25,000 28,000 30,000 30,000 42,600 45,000 48,500
Current A 7.8 9.5 10.3 13.2 13.6 5.2 7.0 7.5 8.6
Power Input: Rated kW 1.69 2.05 2.22 2.84 2.93 2.93 4.07 4.37 4.90
W/W 3.2 3.29 3.30 2.89 3.00 3.00 3.07 3.02 2.90
EER
Btu/hW 10.91 11.22 11.25 9.85 10.23 10.23 10.47 10.30 9.89
Indoor Unit
Air Volume m3/min 24.0 25.0 25.0 25.0 25.0 25.0 33.0 33.0 33.0
Sound Pressure Level (Hi/Lo) dB (A) 41 / 32 41 / 32 41 / 32 41 / 33 41 / 33 41 / 33 45 / 37 45 / 37 46 / 41
Sound Power Level (Hi/Lo) dB 56 / 47 56 / 47 56 / 47 56 / 48 56 / 48 56 / 48 60 / 52 60 / 52 61 / 56
Indoor (H×W×D) mm 256 × 840 × 840 256 × 840 × 840 256 × 840 × 840 256 × 840 × 840 256 × 840 × 840 256 × 840 × 840 319 × 840 × 840 319 × 840 × 840 319 × 840 × 840
Dimension
Panel (H×W×D) mm 950 × 950 × 44 950 × 950 × 44 950 × 950 × 44 950 × 950 × 44 950 × 950 × 44 950 × 950 × 44 950 × 950 × 44 950 × 950 × 44 950 × 950 × 44
Indoor kg 19 20 20 20 20 20 22 22 22
Net Weight
Panel kg 4 4 4 4 4 4 4 4 4
Outdoor Unit
Sound Pressure Level dB (A) 52 52 52 56 56 57 56 56 56
Sound Power Level dB 68 68 68 71 71 71 70 70 70
Dimension Outdoor (H×W×D) mm 695 × 875 × 320 695 × 875 × 320 695 × 875 × 320 695 × 875 × 320 695 × 875 × 320 750 × 875 × 345 996 × 980× 370 996 × 980× 370 996 × 980× 370
Net Weight kg 44 55 55 57 57 58 86 86 90
Gas Pipe mm (inch) 12.70 (1/2”) 15.88 (5/8”) 15.88 (5/8”) 15.88 (5/8”) 15.88 (5/8”) 15.88 (5/8”) 15.88 (5/8”) 15.88 (5/8”) 15.88 (5/8”)
Piping Connection
Liquid Pipe mm (inch) 6.35 (1/4”) 9.52 (3/8”) 9.52 (3/8”) 9.52 (3/8”) 9.52 (3/8”) 9.52 (3/8”) 9.52 (3/8”) 9.52 (3/8”) 9.52 (3/8”)
Pipe Length Min~Max m 7.5 - 30 7.5 - 30 7.5 - 30 7.5 - 45 7.5 - 45 7.5 - 45 7.5 - 50 7.5 - 50 7.5 - 50
Elevation Difference 20 20 20 25 25 25 30 30 30
Maximum Chargeless Length Max m 7.5 7.5 7.5 7.5 7.5 7.5 30 30 30
Additional Gas g/m 20 25 25 30 30 30 50 50 50
Operating Range, Outdoor Min~Max °C 16 - 43 16 - 43 16 - 43 16 - 43 16 - 43 16 - 43 16 - 43 16 - 43 16 - 43

14 Please refer to technical documents for more details. 15


CEILING
Indoor Unit | Ceiling

700 7 or more
Model No. Dimensions (22.5–27k Btu/h)

84.5
S-22PT1H5 S-45PT1H5

101
151
S-28PT1H5 S-55PT1H5

210
S-35PT1H5
1115 120

90
1245

Wireless remote controller Required space for installation


Photo receiver unit position 7 or more
TECHNICAL FOCUS 40 1165 40
7 or more

108 66
500

42
or more
• Compact Looking, Stylish,

2500-3000
One-Motion Design 300 or less Obstacles
Floor

71
• Energy-Saving Technology Delivering
Top-Class Efficiency

Drain position
• Comfortable, Long-Distance Air Flow 500 or more 500 or more

211
236
287
61 Left
Distribution side drain
port
89
112 Right side drain port
unit:mm
144

700 7 or more

Dimensions (36.5–51k Btu/h)

124.5
141
191
250
1470 120

90
1600

Wireless remote controller


Photo receiver unit position Required space for installation
40 1520 40 7 or more
7 or more
108 66

42
500
or more
Selectable

2500-3000
Remote Controller

71
300 or less Obstacles
Floor

Drain position
287
61 Left 500 or more 500 or more
side drain 89
port Right side drain port
112
144 unit:mm
CZ-RD513C CZ-RL013T

Capacity ( Btu/h ) 22,500 27,000 36,500 43,000 51,000


Power Source V/Phase Hz 220 V, 1Ø Phase - 50 Hz 380 V, 3Ø phase - 50Hz
Indoor S-22PT1H5 S-28PT1H5 S-35PT1H5 S-45PT1H5 S-55PT1H5
Outdoor U-22PV1P5 U-28PV1P5 U-35PV1P8 U-45PV1P8 U-55PV1P8
kW 6.59 7.91 10.70 12.61 14.95
Cooling Capacity: Rated
Btu/h 22,500 27,000 36,500 43,000 51,000
Current A 10.0 12.8 6.4 7.4 9.5
Power Input: Rated kW 2.16 2.75 3.72 4.30 5.44
W/W 3.05 2.88 2.88 2.93 2.75
EER
Btu/hW 10.40 9.82 9.82 9.99 9.38
Indoor Unit
Air Volume m3/min 17.0 18.0 29.0 31.0 32.0
Sound Pressure Level (Hi/Lo) dB (A) 43 / 39 45 / 41 47 / 43 49 / 45 50 / 46
Sound Power Level (Hi/Lo) dB 58 / 54 60 / 56 62 / 58 64 / 60 65 / 61
Dimension Indoor (H×W×D) mm 210 × 1,245 × 700 210 × 1,245 × 700 250 × 1,600 × 700 250 × 1,600 × 700 250 × 1,600 × 700
Net Weight kg 33 33 43 48 48
Outdoor Unit
Sound Pressure Level dB (A) 52 56 56 56 56
Sound Power Level dB 68 71 70 70 70
Dimension Outdoor (H×W×D) mm 695 × 875 × 320 695 × 875 × 320 996 × 980 × 370 996 × 980 × 370 1,170 × 900 × 320
Net weight kg 55 57 86 86 94
Gas Pipe mm (inch) 15.88 (5/8”) 15.88 (5/8”) 15.88 (5/8”) 15.88 (5/8”) 15.88 (5/8”)
Piping Connection
Liquid Pipe mm (inch) 9.52 (3/8”) 9.52 (3/8”) 9.52 (3/8”) 9.52 (3/8”) 9.52 (3/8”)
Pipe Length Min~Max m 7.5 - 30 7.5 - 45 7.5 - 50 7.5 - 50 7.5 - 50
Elevation Difference 20 25 30 30 30
Maximum Chargeless Length Max m 7.5 7.5 30 30 30
Additional Gas g/m 25 30 50 50 50
Operating Range, Outdoor Min~Max °C 16 - 43 16 - 43 16 - 43 16 - 43 16 - 43

16 Please refer to technical documents for more details. 17


DUCTED
Indoor Unit | Ducted

1050
Model No. Dimensions (22.5–28k Btu/h) 920 40 100
S-22PF1H5 S-45PF1H5 780(P65 x 12) 70
65
S-28PF1H5 S-55PF1H5

36
Required space for installation
S-35PF1H5
37 210 43

428
40 72.5 55

30

36
TECHNICAL FOCUS

560
500
65
780(P65 x 12) 30
840 130
• Total Cooling Coverage

30
72.5 55 20 1000 20
30 210 50

• Flexible Installation
• Easy Installation 1120

• Easy Maintenance & Cleaning

290
unit:mm

80
1060
Dimensions (36–51k Btu/h) 920 40 100
845(P65 x 13) 37.5
65

55
Required space for installation

40 275 45
195(P65x3)

540
40
65

30

55
65
B45(P65 x 13)

650
37.5
920 40
20 1000 20
65

30
40 195(P65x3)

20 275 65
Remote Controller
1120

360
A remote controller is

110
in the same package unit:mm
with the indoor unit.

Capacity ( Btu/h ) 22,500 28,000 36,000 42,500 51,000


Power Source V/Phase Hz 220 V, 1Ø Phase - 50 Hz 380 V, 3Ø phase - 50Hz
Indoor S-22PF1H5 S-28PF1H5 S-35PF1H5 S-45PF1H5 S-55PF1H5
Outdoor U-22PV1P5 U-28PV1P5 U-35PV1P8 U-45PV1P8 U-55PV1P8
kW 6.59 8.21 10.55 12.45 14.95
Cooling Capacity: Rated
Btu/h 22,500 28,000 36,000 42,500 51,000
Current A 10.0 13.3 7.0 7.8 9.7
Power Input: Rated kW 2.16 2.87 4.06 4.53 5.58
W/W 3.05 2.86 2.60 2.75 2.68
EER
Btu/hW 10.40 9.75 8.87 9.38 9.14
External Static Pressure Pa (mm Ag) 69 (7) 69 (7) 98 (10) 98 (10) 98 (10)
Indoor Unit
Air Volume m3/min 22.0 22.0 45.0 45.0 45.0
Sound Pressure Level (Hi/Lo) dB (A) 45 / 41 45 / 41 49 / 45 49 / 45 49 / 45
Sound Power Level (Hi/Lo) dB 60 / 56 60 / 56 64 / 60 64 / 60 64 / 60
Dimension Indoor (H×W×D) mm 290 × 1,100 × 500 290 × 1,100 × 500 360 × 1,100 × 650 360 × 1,100 × 650 360 × 1,100 × 650
Net Weight kg 31 31 43 43 43
Outdoor Unit
Sound Pressure Level dB (A) 52 56 56 56 56
Sound Power Level dB 68 71 70 70 70
Dimension Outdoor (H×W×D) mm 695 × 875 × 320 695 × 875 × 320 996 × 980 × 370 996 × 980 × 370 1,170 × 900 × 320
Net weight kg 55 57 86 86 94
Gas Pipe mm (inch) 15.88 (5/8”) 15.88 (5/8”) 15.88 (5/8”) 15.88 (5/8”) 15.88 (5/8”)
Piping Connection
Liquid Pipe mm (inch) 9.52 (3/8”) 9.52 (3/8”) 9.52 (3/8”) 9.52 (3/8”) 9.52 (3/8”)
Pipe Length Min~Max m 7.5 - 30 7.5 - 45 7.5 - 50 7.5 - 50 7.5 - 50
Elevation Difference 20 25 30 30 30
Maximum Chargeless Length Max m 7.5 7.5 30 30 30
Additional Gas g/m 25 30 50 50 50
Operating Range, Outdoor Min~Max °C 16 - 43 16 - 43 16 - 43 16 - 43 16 - 43

18 Please refer to technical documents for more details. 19


OUTDOOR UNITS
Outdoor Unit

Dimensions (18.5–30k Btu/h) 1-phase Dimensions (36–48.5k Btu/h) 3-phase


U-18PV1P5, U-22PV1P5, U-25PV1P5, U-28PV1P5, U-30PV1P5 U-35PV1P8, U-40PV1P8, U-45PV1P8, U-50PV1P8

10 160 660 160

412.5
370

450
20.5
980
36 370

996
Unit:mm Unit:mm

Dimensions (30k Btu/h) 3-phase Dimensions (54k Btu/h) 3-phase


U-30PV1P8  U-55PV1P8

Unit:mm Unit:mm

20  21


MEMO

22 23

You might also like