You are on page 1of 3

2701 Miles Road SE

EWC-1 Albuquerque, New Mexico 87106


505 242 5700 office
EWC-1 505 242 0673 fax
MolzenCorbin.com

LAV-1 LAV-1

LAV-1 LAV-1

WHA-1
WC-1
WC-1 WHA-1
WC-1
WC-1

SANTA FE AIRPORT TERMINAL IMPROVEMENTS - CIP PROJECT #611B


GI-1

PLUMBING WATER, SEWER AND VENT PLAN

SANTA FE MUNICIPAL AIRPORT (SAF)


LAV-1

LAV-1

SANTA FE, NEW MEXICO


LAV-1

LAV-1

EWC-1

LAV-1 LAV-1

WHA-1
WC-1
WC-1

LAV-1
GI-1

LAV-1

LAV-1

LAV-1

P-101
2701 Miles Road SE
Albuquerque, New Mexico 87106
505 242 5700 office
505 242 0673 fax
MolzenCorbin.com

LAV-1 LAV-1 EWC-1

WC-2 WC-1

GI-1

SANTA FE AIRPORT TERMINAL IMPROVEMENTS - CIP PROJECT #611B


SANTA FE MUNICIPAL AIRPORT (SAF)
PLUMBING SCHEMATICS

SANTA FE, NEW MEXICO


WHA-1

EWC-1 LAV-1 LAV-1 WC-1 WC-1

P-201
PLUMBING LEGEND PLUMBING GENERAL NOTES PLUMBING SCHEDULE
A. CONTRACTORS AND SUB-CONTRACTORS SHALL CAREFULLY REVIEW THE CONSTRUCTION DOCUMENTS. INFORMATION REGARDING THE COMPLETE WORK IS DISPERSED WATER CLOSET (ADA): FLOOR MOUNTED, LOW FLOW, HIGH EFFICIENCY TOILET, WHITE VITREOUS CHINA, EVERCLEAN SURFACE, FULL GLAZED TRAPWAY, ELONGATED, TOP
SYMBOL DESCRIPTION WC-1
THROUGHOUT THE DOCUMENT SET AND CANNOT BE ACCURATELY DETERMINED WITHOUT REFERENCE TO THE COMPLETE DOCUMENT SET. SPUD. MFG: AMERICAN STANDARD MADERA #3461.001. FLUSH VALVE: SINGLE FLUSH 1.6 GPF, MANUAL OPERATED, CHROME PLATED, EXPOSED. MFG: ZURN 6000. SEAT:
HOT WATER CIRCULATION HEAVY DUTY, OPEN FRONT LESS COVER, SOLID PLASTIC, WHITE. FLUSH VALVE LEVER ON WIDE OPEN ACCESS SIDE OF TOILET AREA. MFG: AMERICAN STANDARD #5901.100.
HOT WATER B. COORDINATE WITH THE WORK OF OTHER TRADES, EQUIPMENT FURNISHED BY OTHERS, REQUIREMENTS OF THE OWNER, AND WITH THE CONSTRAINTS OF THE CONDITIONS AT SERVICE REQUIREMENTS: 4" S, 2" V, 1" CW.
COLD WATER THE PROJECT SITE. 2701 Miles Road SE
LAV-1 LAVATORY (ADA): COUNTER MOUNTED, VITREOUS CHINA, 4" CENTERS, SELF RIMMING OVAL SHAPE MFG: AMERICAN STANDARD NO. 0476.028 "AQUALYN". Albuquerque, New Mexico 87106
SANITARY SEWER
C. DRAWINGS FOR PLUMBING WORK ARE DIAGRAMMATIC, SHOWING THE GENERAL LOCATION, TYPE, LAYOUT, AND EQUIPMENT REQUIRED. PROVIDE PLUMBING, CONNECTIONS, DECK MOUNTED, SINGLE METAL LEVER HANDLE, ADA. FURNISH WITH 0.5 GPM MAX FLOW OUTLET. FAUCET: CHICAGO 420-E2805ABCP. DRAIN: FURNISHED WITH LAV. SUPPLIES: 505 242 5700 office
VENT ACCESSORIES, OFFSETS, CONTROLS AND MATERIALS NECESSARY FOR A COMPLETE FUNCTIONAL SYSTEM INSTALLATION. STANDARD LOOSE KEY, 12" COMPRESSION x 3 8" OD STOP VALVE, FLEXIBLE RISERS, CHROME PLATED. MFG: MCGUIRE. TRAP: 11/4" IN x 11/2" OUT, CHROME PLATED, 505 242 0673 fax
ADJUSTABLE, SEMI-CAST TRAP. MFG: MCGUIRE. MOUNTING HEIGHT: SEE ARCHITECTURAL DRAWINGS. NOTE: HOT WATER SUPPLY LINE AND WASTE SHALL BE INSULATED WITH MolzenCorbin.com
CONDENSATE DRAIN OR DRAIN D. BALL VALVES 2 INCHES AND SMALLER SHALL BRONZE BODY, BLOW-OUT PROOF CAPTIVE STEM, DOUBLE TEFLON SEATS, FULL PORTED, STAINLESS STEEL OR CHROME PLATED FACTORY PREMOLDED INSULATION. MFG: TRUEBRO LAVGUARD 2. SERVICE REQUIREMENTS: 121" S , 121" V, 12" CW AND 12" HW.
BRASS BALL, TWO-PIECE, THREADED OR SOLDERED ENDS. NIBCO T-585-70 OR S-585-70, OR A THREE-PIECE BRONZE BODY, FULL PORT, STAINLESS STEEL TRIM, WITH A
NATURAL GAS BLOWOUT-PROOF STEM. NIBCO T OR S-595-Y OR EQUIVALENT. ELECTRIC WATER COOLER (ADA): BI LEVEL DESIGN WITH ONE UNIT AT STANDARD HEIGHT AND 2ND UNIT AT ADA HEIGHT. UNITS ARE WALL MOUNTED LIGHT GRAY GRANITE
EWC-1
WATER COOLERS. 8 GPH FROM 80°F TO 50°F WITH AMBIENT TEMPERATURE OF 90°F. WALL HUNG, SELF CONTAINED REFRIGERATION SYSTEM AND GALVANIZED
NON POTABLE WATER E. SWING CHECK VALVES 2 INCHES AND SMALLER: CLASS 125, THREADED ENDS, BRONZE BODY, Y PATTERN, RENEWABLE SEAT AND DISK, AND SCREW CAP. NIBCO T-413 F OR STEEL FRAME. FRONT AND SIDE PUSH BUTTONS. ADA COMPLIANT WITH NO LEAD DESIGN. COMPRESSOR RECIPROCATING, HERMETICALLY SEALED, 370 WATTS, 4.0 FULL LOAD
EQUIVALENT. AMPS, 115V/60HZ/1PH COMPRESSOR. FURNISH WITH CHORD AND POLARIZED PLUG. WALL MOUNTING FRAME, DRAIN AND TRAP FURNISHED WITH UNIT. SERVICE
MEDICAL AIR
REQUIREMENTS: 1 14" S, 1 1 4"V, 12" CW. MOUNTING HEIGHT: SEE ARCHITECTURAL DRAWINGS. MFG: ELKAY EZSTL8.
OXYGEN F. DOMESTIC COLD WATER, DOMESTIC HOT WATER AND TEPID WATER PIPING SHALL BE INSTALLED WITH 1 INCH THICK PREFORMED PIPE INSULATION COMPLYING WITH ASTM
NITROUS OXIDE C547, TYPE I-MOLDED WITH FACTORY APPLIED, ALL PURPOSE, VAPOR RETARDER JACKET WITH SELF SEALING ADHESIVE LAP. UTILIZE STANDARD PVC FITTING COVERS WITH WATER HAMMER ARRESTOR:
FIBERGLASS INSERTS FOR 45 OR 90 DEGREE FITTINGS. INSULATION CONDUCTIVITY SHALL NOT EXCEED 0.27 BTU PER INCH/H xFT^2x°F. FURNISH WITH PVC OR ALUMINUM WHA-1
STAINLESS STEEL SHOCK ABSORBER, 1", PRE-CHARGED, SIZED FOR 12-32 FIXTURE UNITS. MFG: JR SMITH 5010.
ANESTHESIA EVAC JACKET WHEN EXPOSED IN FINISHED SPACES OR WHEN INSTALLED 10 FEET BELOW CEILING IN MECHANICAL ROOMS. COLD WATER PIPING INSULATION SHALL HAVE A VAPOR
FILTERED WATER BARRIER. AT ALL HANGER AND SUPPORT LOCATIONS, PROVIDE 8 INCH LONG, 20 GUAGE GALVANIZED IRON INSULATION GUARDS. INSULATION AT THESE LOCATIONS SHALL BE GREASE INTERCEPTOR: ACID RESISTANT COATED INTERIOR AND EXTERIOR FABRICATED STEEL GREASE INTERCEPTOR, RATED AT 10 GPM AND 20 LB GREASE CAPACITY, WITH
GI-1
RIGID. INTERNAL RELIEF BY PASS, BRONZE CLEANOUT PLUG, REMOVABLE PRESSURE EQUALIZING/FLOW DIFFUSING INLET BAFFLE, FIXED BOTTOM OUTLET BAFFLE, AND VISIBLE
THERMOMETER DOUBLE WALL TRAP SEAL. FURNISH WITH 2" LOW INLET, 2" HIGH OUTLET. GASKETED NON SKID SECURED COVER COMPLETE WITH CENTER TIE DOWN ASSEMBLY WITH Z1108
G. DOMESTIC WATER, HOT WATER, AND COLD WATER PIPING ABOVE GRADE SHALL BE TYPE L HARD DRAWN COPPER TUBING, ASTM B88, WITH WROUGHT COPPER SOLDER TYPE FLOW CONTROL FITTING. MFG: ZURN Z1170 SIZE 300 OR EQUIVALENT.
FITTINGS CONFORMING TO ASME B16.22 OR CAST COPPER CONFORMING TO ASME B16.18. JOINTS SHALL BE SOLDERED WITH 95-5 LEAD FREE SOLDER. PLUMBING FOR
FLOOR SINK AND FLOOR DRAIN POTABLE DOMESTIC WATER SYSTEMS MUST BE LEAD FREE PER PUBLIC LAW 99-339, SAFE DRINKING WATER ACT. LEAD FREE IS DEFINED AS NO MORE THAN 0.2 PERCENT LEAD
IN SOLDER AND FLUX, AND NOT MORE THAN 8 PERCENT LEAD IN PIPE AND FITTINGS. FOR POTABLE WATER SERVICE, PROVIDE PIPING AND FITTINGS COMPLYING WITH NSF 61.
STRAINER
H. GAS PIPING, INDOOR OR OUTDOOR, ABOVE GRADE: SCHEDULE 40 BLACK STEEL OR SCHEDULE 40 GALVANIZED STEEL, SEAMLESS TYPE S OR WELDED TYPE E, ASTM A53/A53M.
CLEAN OUT TO GRADE OR FLOOR CLEANOUT FITTINGS 2 INCHES AND SMALLER: CLASS 150, BANDED MALLEABLE IRON, SCREWED, ASME B16.3. GALVANIZED FITTINGS SHALL BE HOT DIPPED IN ACCORDANCE ASTM A153. 2½
INCHES AND LARGER: CLASS 150, SCHEDULE 40 WROUGHT STEEL BUTT-WELD FITTINGS, ASME B16.9. ALL UNDERGROUND GAS PIPING SHALL POLYETHYLENE PLASTIC PIPING
AND FITTINGS CONFORMING TO USE FOR NATURAL GAS DELIVERY.
DOUBLE CLEANOUT TO GRADE
I. GAS PLUG VALVES SHALL BE THE FOLLOWING OR EQUIVALENT: OUTDOOR SYSTEMS, 2 INCHES AND SMALLER: CAST IRON BODY, THREADED ENDS, FLAT-HEAD
WALL CLEANOUT (WCO) OR CLEANOUT (CO) LOCK-WING,NONLUBRICATED FULL-PORT BRASS PLUG, 100 PSIG NATURAL OR PROPANE GAS RATING, RATED FOR USE IN AMBIENT TEMPERATURES BETWEEN -20°F AND 150°F, A.Y. MCDONALD
10687B. IF AN INSULATING UNION IS REQUIRED, THE SAME REQUIREMENTS WOULD BE APPLIED, A.Y. MCDONALD 6266 SERIES. OUTDOOR SYSTEMS, 2½ INCHES AND GREATER: CAST IRON OR
PRESSURE REDUCING VALVE OR REGULATOR
DUCTILE IRON BODY, ANSI 125 FLANGED, SEALS RATED FOR GAS, NONLUBRICATED ECCENTRIC-TYPE ONE-PIECE PLUG, NATURAL OR PROPANE GAS RATING, MILLIKEN MILLICENTRIC SERIES 600.
INDOOR SYSTEMS, APPLIANCE SHUTOFF VALVE: BRASS BODY AND PLUG, LOCK-WING HEAD, THREADED ENDS, 25 PSIG RATING, A.Y. MCDONALD SERIES 10621. INDOOR SYSTEMS, 2½ INCHES
PRESSURE GAUGE
AND GREATER: CAST IRON OR DUCTILE IRON BODY, ANSI 125 FLANGED, SEALS RATED FOR GAS, NONLUBRICATED ECCENTRIC-TYPE ONE-PIECE PLUG, NATURAL OR PROPANE GAS RATING,
MILLIKEN MILLICENTRIC SERIES 600.
T&P RELIEF
J. GAS APPLIANCE FLEX CONNECTORS SHALL BE STAINLESS STEEL OR COATED STAINLESS STEEL, CORRUGATED, ANSI Z21.24, CONNECTORS FOR GAS APPLIANCES, CERTIFIED FOR INDOOR AND
BACKFLOW PREVENTER OR DOUBLE CHECK OUTDOOR USE. BRASSCRAFT MODEL NO. SSC OR CSSC.
BALL VALVE
K. SEWER AND VENT PIPING BELOW GRADE CAN BE THE FOLLOWING:
GATE VALVE
1. PVC PIPE: ASTM D2665, DWV. USE PVC FITTINGS, ASTM D2665. JOINTS: ASTM D2855 SOLVENT WELD WITH ASTM D2564 SOLVENT CEMENT.
GATE VALVE IN VALVE BOX
2. CAST IRON SOIL PIPE: ASTM A74, SERVICE WEIGHT, BELL AND SPIGOT ENDS. USE CAST IRON FITTINGS, ASTM A74. JOINTS: HUB AND SPIGOT, CISPI HSN COMPRESSION TYPE
GAS VALVE OR CIRCUIT SETTER WITH ASTM C564 NEOPRENE GASKETS OR LEAD AND OAKUM. JOINTS MANUFACTURED BY TYLER LUBRI/FAST OR EQUIVALENT.

CHECK VALVE L. SEWER , VENT AND ROOF DRAIN LEADER PIPING ABOVE GRADE CAN BE THE FOLLOWING:
VALVE IN RISER
VALVE IN DROP 1. PVC PIPE: PVC PIPE: ASTM D2665, DWV. USE PVC FITTINGS, ASTM D2665. JOINTS: ASTM D2855 SOLVENT WELD WITH ASTM D2564 SOLVENT CEMENT. PIPING WITHIN ANY
PIPING DROP AIR PLENUM SPACE IS REQUIRED TO BE PROVIDED WITH PVC JACKET THAT IS WHITE, FLAME/SMOKE 25/50 RATED PER ASTM E84 AND UL 723, UV RESISTANT WITH MINIMUM
PIPING RISE THICKNESS OF 0.020 INCHES OR WRAPPED WITH 3M FIRE BARRIER PLENUM WRAP TO MEET A FLAME/SMOKE RATING OF 25/50 OR LESS PER ASTM E84 AND UL 723.
2. CAST IRON PIPE: CISPI 301, HUBLESS, SERVICE WEIGHT. FITTINGS: CAST IRON, CISPI 301. JOINTS: CISPI 310, NEOPRENE GASKETS AND STAINLESS STEEL CLAM AND SHIELD
PIPING "T" DROP ASSEMBLIES.
CAP 3. STEEL PIPE: ASTM A53/A53M SCHEDULE 40 GALVANIZED. FITTINGS: CAST IRON, ASME B16.1, FLANGES AND FITTINGS; ASME B16.4, THREADED FITTINGS. OR FITTINGS:
REDUCER MALLEABLE IRON, ASME B16.3, THREADED TYPE ASTM A47/A47M. JOINTS: THREADED FOR PIPE 2 INCH AND SMALLER; FLANGED FOR PIPE 2-1/2 INCHES AND LARGER.

UNION M. CONDENSATE DRAIN PIPING TO BE HARD DRAWN COPPER DRAINAGE TUBE (DWV) ASTM B306 WITH WROUGHT DRAINAGE FITTINGS IN ACCORDANCE WITH ASME B16.29. JOINTS
SHALL BE SOLDERED WITH 95-5 SOLDER.
HOSE BIB OR WALL HYRANT
MISCELLANEOUS N. PRESSURE DRAIN PIPING TO BE COPPER TUBING, ASTM B88 TYPE L DRAWN. FITTINGS: ASME B16.18, CAST BRASS OR ASME B16.22 SOLDER WROUGHT COPPER. JOINTS: ASTM
B32, SOLDERED WITH 95-5 LEAD FREE SOLDER.

SANTA FE AIRPORT TERMINAL IMPROVEMENTS - CIP PROJECT #611B


LAV-1 EQUIPMENT/FIXTURE LIST DESIGNATION O. INSTALL PIPE ESCUTCHEONS IN FINISHED SPACES FOR PIPE PENETRATIONS OF CONCRETE, MASONRY WALLS, WALL BOARD PARTITIONS AND SUSPENDED CEILINGS.

KEYED CONSTRUCTION NOTE P. INSTALL SLEEVES FOR PIPING PASSING THROUGH INTERIOR CONCRETE WALLS, METAL WALLS, MASONRY WALLS, FIRE RATED GYPSUM WALLS, CONCRETE FLOORS AND ROOF
SLABS. SLEEVES CAN BE STEEL SHEET METAL 24 GAUGE MINIMUM, SCHEDULE 40 GALVANIZED STEEL PIPE-ASTM A53-TYPE E-GRADE A, OR CAST IRON-ASTM A74.
NUMBER IN SYMBOL REFERS TO DETAIL #
Q. PIPE PENETRATIONS THRU FIRE/SMOKE RATED ASSEMBLIES SHALL BE FIRE CAULKED AIRTIGHT TO ADJACENT STRUCTURE BY MEANS OF A U.L. OR FM APPROVED FIRE PROOF
INDICATES NAME OF DETAIL CAULKING MATERIAL CONFORMING TO THE CONSTRUCTION TYPE, PENETRATE TYPE, ANNULAR SPACE REQUIREMENTS, AND FIRE RATING.

R. PIPE PENETRATIONS THRU NON FIRE RATED ASSEMBLIES SHALL BE CAULKED AIRTIGHT BY MEANS OF APPROVED CAULKING MATERIAL. PROVIDE JOINT SEALERS, JOINT FILLER
FLOW ARROW AND OTHER RELATED MATERIALS THAT ARE COMPATIBLE UNDER CONDITIONS OF APPLICATION. PROVIDE COLOR OF EXPOSED JOINT SEALERS TO CLOSELY MATCH FINISH
BREAK OR CONTNUATION COLOR OF ADJACENT SURFACES.

S. INSTALL PIPE LABELS ON EACH SYSTEM. INCLUDE ARROWS SHOWING NORMAL DIRECTION OF FLOW. LOCATE LABELS IN FINISHED SPACES, MECHANICAL ROOMS, ACCESSIBLE

SANTA FE MUNICIPAL AIRPORT (SAF)


NEW TO EXISTING CONNECTION

PLUMBING SCHEDULES AND NOTES


MAINTENANCE SPACES SUCH AS SHAFTS, TUNNELS, PLENUMS AND EXTERIOR NON CONCEALED LOCATIONS.

T. BEFORE ANY INSULATION IS INSTALLED OR BEFORE PIPING IS COVERED OR TURNED OVER TO OWNER, ALL WATER PIPING SYSTEMS SHALL BE HYDROSTATICALLY TESTED AND
PROVEN TIGHT AT NOT LESS THAN 125 PSIG AND MUST SHOW NO DROP IN PRESSURE IN A 2 HOUR PERIOD.

SANTA FE, NEW MEXICO


U. SANITARY SEWER AND VENT PIPING SHALL BE TESTED BY APPLYING A 10 FOOT HEAD OF WATER PRESSURE ABOVE THE HIGHEST LINE TO BE TESTED. THE SEGMENT OF THE
SYSTEM BEING TESTED MUST HOLD WATER PRESSURE FOR ONE HOUR WITHOUT SHOWING A DROP IN LEVEL. ALL SEWER AND VENT PIPING LOCATED UNDERGROUND MUST BE
TESTED BEFORE BACKFILLING.

V. WALL CLEANOUTS SHALL BE DURA COATED CAST IRON BODY, GAS AND WATER TIGHT ABS TAPERED THREAD PLUG AND ROUND SMOOTH STAINLESS STEEL ACCESS COVER WITH
SECURING SCREW. MANUFACTURED BY ZURN OR EQUIVALENT.

W. FLOOR CLEANOUTS AND DOUBLE CLEANOUTS SHALL BE HEAVY DUTY DUCO CAST IRON CLEANOUT WITH ROUND ADJUSTABLE SCORIATED BRONZE TOP. CLOSURE PLUG TYPE.
PIPE OUTLET SAME SIZE AS PIPE AND CONNECTION LIQUID - AIR TIGHT AND COMPATIBLE WITH PIPE. MANUFACTURED BY JR SMITH, ZURN OR EQUIVALENT.

X. PIPE HANGERS FOR WATER AND CONDENSATE PIPING SHALL CONFORM TO MSS SP-58; MATERIAL AND DESIGN OF PIPE SUPPORTS, MSS SP-69: SELECTION AND APPLICATION OF
PIPE SUPPORTS, AND MSS SP-89: FABRICATION AND INSTALLATION OF PIPE SUPPORTS.

Y. PIPE HANGERS FOR SEWER AND VENT PIPING SHALL SHALL CONFORM TO MSS SP-58; MATERIAL AND DESIGN OF PIPE SUPPORTS, MSS SP-69: SELECTION AND APPLICATION OF
PIPE SUPPORTS, AND MSS SP-89: FABRICATION AND INSTALLATION OF PIPE SUPPORTS.

Z. PIPING SHALL BE SUPPORTED WITH HANGERS, ANCHORS AND SUPPORTS DESIGNED TO CARRY THE LOAD OF THE PIPE FULL OF FLUID, AND SHALL RESIST GALVANIC ACTION.
SECURE UPPER ATTACHMENTS TO STRUCTURE. DO NOT SUPPORT FROM THE ROOF DECK. SUPPORT INTERVALS AND ROD SIZE AS FOLLOWS:

COPPER TUBE HORIZONTAL PIPING:


1 1 3
2" THRU 1 2" MAX 6 FEET 8" ROD
3
2" AND LARGER MAX 10 FEET 8"ROD UP TO 2", 12" ROD FOR 2" THRU 3" PIPE, 5 8" ROD FOR 4" THRU 5" PIPE

SCH. 40 STEEL HORIZONTAL PIPING:

1 3
2" MAX 6 FEET 8"
ROD
3 3
4"-1" MAX 8 FEET 8 ROD
"
114" MAX 10 FEET 1 5 3
2" ROD FOR 2.5" THRU 3" PIPE, 8" ROD FOR 4" THRU 5" PIPE, 4"ROD FOR 6" PIPE

5
HORIZONTAL CAST IRON (ALL SIZES) MAX 5 FEET 8" ROD
5
HORIZONTAL CAST IRON WITH 10' LENGTH MAX 10 FEET 8" ROD

3
PVC (ALL SIZES) MAX 4 FEET 8"ROD UP TO 4", 12" ROD FOR 5" THRU 8" PIPE, 5 8" ROD FOR 10" THRU 12" PIPE

P-601