Fastmig Basic/Synergic error codes

Error Problem description Solution description


Main supply under voltage, alert. Check the main supply voltage.
2

Main supply long over voltage, alert. Check the main supply voltage
3

Power supply over heating. Check if duty cycle is overridden continuously, cooling fans are
jammed, heat sink is blocked or clean cooling air is not flowing
4
free.

Water cooler error. Check if water cooler is and all the water hoses are connected.
Check there is enough water in the tank. Check water cooler
5
manual for further instructions.

Communication error, noticed by power One of the system devices has wrong configuration or too many
source. System has two devices with same ID devices connected to the system. Check the device ID
11
number. numbers.

Communication error, noticed by power Check the device compatibility with the system.
source. Device is not compatible with system
13
bus.

Communication error, noticed by power Check the connections and the cables.
source. Connection to other devices has lost.
14

Power source auxiliary voltage low. Control Check the control card, its psu might be faulty.
cards +5VDC is too low.
21

Power source auxiliary voltage low. Control Check the control card, its psu might be faulty.
cards +15VDC is too low.
22

Main supply short over voltage, warning. Check the main supply voltage, if error exists continuously.
23

Power source calibration values not found. Machine can be used, power source uses default values.
Restarting the machine might help.
31

Communication error, noticed by Mig logic. Check the connections and the cables.
Power source not available.
54

Welding not allowed, while triggering the Check if another device uses the system at the same time.
machine.
55

Water cooling unit not found. Water cooled Check if water cooler is connected properly.
gun is selected but cooler is not responding.
61

Water cooled Mig gun is overheated. Mig gun Check the cooling liquid temperature. Is water cooled gun right
PTC has given alert. size comparing to the welding current and duty cycle.
153
Wire feeder motor current over the limit, alert, Check the consumable parts and motor current. Motor current
welding is prevented. can be checked by pressing wire inch button and setup button
154
simultaneously.

Wire feeder motor current rising close to the Check the consumable parts and motor current. Motor current
limit, warning. can be checked by pressing wire inch button and setup button
155
simultaneously.

Gas guard activated. Gas cylinder is empty or Check the gas cylinder and replace if needed.
pressure is too low.
165

Feeder ID configuration cannot be read. ID chip might be faulty. This error can be also simulated by
Welding possible only in normal Mig mode, no pressing Mig gun trigger while machine starts up -> restart the
171
synergic Mig or wise/match functions. machine.

License code is not correct. Check if the license code serial number is proper.
172

User has tried to execute function which is Order the license if function is required.
inactivate.
173

Use of PMT Mig gun prevented. Fastmig Basic is not allowed to use PMT Mig gun -> use FU
mode in PMT Mig gun (check the gun manual to execute this).
201 Sometimes gun trigger might has a bad contacts.

User has tried to execute prevented or Check if panel memory channel holds parameters that are not
nonexistent function. allowed in current feeder (e.g. License not activated).
202

System holds improper firmware versions. Check the panel and power source firmware compatibilities.
203

Communication error, noticed by panel. One of the system devices has wrong configuration or too many
System has two devices with same ID devices connected to the system. Check the device ID
221
number. numbers.

Communication error, noticed by panel. Check the device compatibility with the system.
Device is not compatible with system bus.
223

EEPROM holds corrupted information. Machine tries to use default values. Check the control cards.
241