ANOMALY REPORT AR CC
Detection Chantier/ Site Erection Fournisseur/ Supplier Inspection à la réception / As Found Garantie/ POC
(*) Obligation par le fournisseur de compléter cette information/Supplier must complete this mandatory information
Numéro Projet / Project N° Unité / Unit Fournisseur / Supplier Réf. Fournisseur / Supplier Ref. : Réf. Chantier / Site Ref. :
MC18508020
Nom du Projet / Project Name (*) # OA / PO Ligne/ Line TRA 181146 Rev. :
LG2 4101533846 30 WBS # (Budget) : Responsabilité/ Responsibility
No. Dessin / Drawing Rev. # Item
157500-1-15103-002-000001 A 1
QTÉ/ QT
Titre d’anomalie / Anomaly Title : Y
DESCRIPTION :
Émetteur / Issuer
After removal of NDE indications, the part in rough machining condition shows excavations according to the
attached map no. 1487/04.10.2018. These excavations were MT accepted, see the attached MT Report no.
340.
Also, on the same casting, after the RT inspection some indications have been noted as per the attached
report.
Please analyze
Approval Approbation /
HN-AC-2-V-T-003 Rev.B
Ré-inspecté par / Re-inspected by Date Ré-inspecté par / Re-inspected by : Client (Optionnel / Optional) Date