You are on page 1of 1

TIME INFORMATION RECEPTION ABNORMAL, GE LINK BETWEEN GE SWITCHING BOARD AND SERVICE

BOARD FAULTY, SCTP LINK FAULT


TIME INFORMATION RECEPTION ABNORMAL, GE LINK BETWEEN GE SWITCHING BOARD AND SERVICE
BOARD FAULTY
TIME INFORMATION RECEPTION ABNORMAL, GE LINK BETWEEN GE SWITCHING BOARD AND SERVICE
BOARD FAULTY, PATH FAULT
CURRENT CLOCK REFERENCE SOURCE OF MAIN CONTROL BOARD ABNORMAL, CLOCK REFERENCE
SOURCE OF MAIN CONTROL BOARD UNAVAILABLE, TIME INFORMATION RECEPTION ABNORMAL, GE
LINK ON GE SWITCHING BOARD PANEL FAULTY, BOARD HARDWARE FAULT
DSP TIME SYNCHRONIZATION INFORMATION ABNORMAL, TIME INFORMATION RECEPTION ABNORMAL,
GE LINK BETWEEN GE SWITCHING BOARD AND SERVICE BOARD FAULTY
GE LINK BETWEEN GE SWITCHING BOARD AND SERVICE BOARD FAULTY, TDM LINK BETWEEN TDM
SWITCHING BOARD AND SERVICE BOARD FAULTY
BOARD UNAVAILABLE
DSP TIME SYNCHRONIZATION INFORMATION ABNORMAL, COMMUNICATION FAILURE BETWEEN A
SERVICE BOARD AND AN SCU BOARD, GE LINK BETWEEN GE SWITCHING BOARD AND SERVICE
BOARD FAULTY, TDM LINK BETWEEN TDM SWITCHING BOARD AND SERVICE BOARD FAULTY
DSP TIME SYNCHRONIZATION INFORMATION ABNORMAL, GE LINK BETWEEN GE SWITCHING BOARD
AND SERVICE BOARD FAULTY
BOARD UNAVAILABLE, TDM LINK BETWEEN TDM SWITCHING BOARD AND SERVICE BOARD FAULTY,
GE LINK BETWEEN GE SWITCHING BOARD AND SERVICE BOARD FAULTY
COMMUNICATION FAILURE BETWEEN A SERVICE BOARD AND AN SCU BOARD, GE LINK BETWEEN GE
SWITCHING BOARD AND SERVICE BOARD FAULTY, TDM LINK BETWEEN TDM SWITCHING BOARD AND
SERVICE BOARD FAULTY
GE LINK BETWEEN GE SWITCHING BOARD AND SERVICE BOARD FAULTY
COMMUNICATION FAILURE BETWEEN A SERVICE BOARD AND AN SCU BOARD, DSP TIME
SYNCHRONIZATION INFORMATION ABNORMAL, GE LINK BETWEEN GE SWITCHING BOARD AND
SERVICE BOARD FAULTY, TDM LINK BETWEEN TDM SWITCHING BOARD AND SERVICE BOARD FAULTY
DSP TIME SYNCHRONIZATION INFORMATION ABNORMAL, TIME INFORMATION RECEPTION ABNORMAL,
COMMUNICATION FAILURE BETWEEN A SERVICE BOARD AND AN SCU BOARD, GE LINK BETWEEN GE
SWITCHING BOARD AND SERVICE BOARD FAULTY, TDM LINK BETWEEN TDM SWITCHING BOARD AND
SERVICE BOARD FAULTY
BOARD UNAVAILABLE, GE LINK BETWEEN GE SWITCHING BOARD AND SERVICE BOARD FAULTY,
SCTP LINK FAULT
CURRENT CLOCK REFERENCE SOURCE OF MAIN CONTROL BOARD ABNORMAL, CLOCK REFERENCE
SOURCE OF MAIN CONTROL BOARD UNAVAILABLE, TIME INFORMATION RECEPTION ABNORMAL,
COMMUNICATION BETWEEN SUBRACKS FAULTY, GE LINK ON GE SWITCHING BOARD PANEL FAULTY
CURRENT CLOCK REFERENCE SOURCE OF MAIN CONTROL BOARD ABNORMAL, CLOCK REFERENCE
SOURCE OF MAIN CONTROL BOARD UNAVAILABLE, BOARD UNAVAILABLE, GE LINK ON GE
SWITCHING BOARD PANEL FAULTY, BOARD HARDWARE FAULT
DSP TIME SYNCHRONIZATION INFORMATION ABNORMAL, TIME INFORMATION RECEPTION ABNORMAL,
GE LINK BETWEEN GE SWITCHING BOARD AND SERVICE BOARD FAULTY, TDM LINK BETWEEN TDM
SWITCHING BOARD AND SERVICE BOARD FAULTY
CURRENT CLOCK REFERENCE SOURCE OF MAIN CONTROL BOARD ABNORMAL, CLOCK REFERENCE
SOURCE OF MAIN CONTROL BOARD UNAVAILABLE, GE LINK ON GE SWITCHING BOARD PANEL
FAULTY, BOARD UNAVAILABLE, GE LINK BETWEEN GE SWITCHING BOARD AND SERVICE BOARD
FAULTY
BOARD UNAVAILABLE, GE LINK BETWEEN GE SWITCHING BOARD AND SERVICE BOARD FAULTY, GE
LINK ON GE SWITCHING BOARD PANEL FAULTY, BOARD HARDWARE FAULT, LINK BETWEEN GE
SWITCHING BOARDS FAULTY
GE LINK ON GE SWITCHING BOARD PANEL FAULTY, CURRENT CLOCK REFERENCE SOURCE OF MAIN
CONTROL BOARD ABNORMAL, CLOCK REFERENCE SOURCE OF MAIN CONTROL BOARD UNAVAILABLE,
BOARD UNAVAILABLE, GE LINK BETWEEN GE SWITCHING BOARD AND SERVICE BOARD FAULTY
TIME INFORMATION RECEPTION ABNORMAL, GE LINK BETWEEN GE SWITCHING BOARD AND SERVICE
BOARD FAULTY, TDM LINK BETWEEN TDM SWITCHING BOARD AND SERVICE BOARD FAULTY
DSP TIME SYNCHRONIZATION INFORMATION ABNORMAL, GE LINK BETWEEN GE SWITCHING BOARD
AND SERVICE BOARD FAULTY, TDM LINK BETWEEN TDM SWITCHING BOARD AND SERVICE BOARD
FAULTY
GE LINK BETWEEN GE SWITCHING BOARD AND SERVICE BOARD FAULTY, PATH FAULT

You might also like