You are on page 1of 106

PROYECTO VIVIENDA DE INTERES

SOCIAL
MANI-CASANARE
Tipo 2 AC-088-017

MEMORIA DE CÁLCULO

Cra 32 N° 40 – 09 Centro Villavicencio, Meta

Teléfono: (8) 683 8080

Fax: (8) 683 80 80

Cel: 3212164950 - 3142735427


MEMORIAS DE CÁLCULO

CONTENIDO
1. INTRODUCCIÓN ............................................................................................................... 4
2. DESCRIPCION DEL ANALISIS ............................................................................................ 5
3. NORMATIVAS .................................................................................................................. 6
4. PREDIMENSIONAMIENTO DE LOS ELEMENTOS ESTRUCTURALES. ................................. 7
4.1 REQUISITOS GEOMETRICOS PARA VIGAS DE CIMENTACIÓN. ................................. 7
Dimensiones de secciones de vigas de cimentación asumidas .............................................. 7
5. MATERIALES Y COEFICIENTES DE SEGURIDAD ................................................................ 8
5.1 MATERIALES ............................................................................................................. 8
5.2 COEFICIENTES DE SEGURIDAD ................................................................................. 8
6. EVALUACIÓN DE CARGAS .............................................................................................. 10
6.1 EVALUACIÓN DE CARGAS ENTREPISO ................................................................... 10
6.2 EVALUACIÓN DE CARGAS CUBIERTA ..................................................................... 11
7. DATOS DE ENTRADA Y SALIDA DEL MODELO MATEMATICO........................................ 12
7.1. IMÁGENES DEL MODELO MATEMATICO .................................................................. 32
8. ANALISIS ESTRUCTURAL ................................................................................................ 37
9. ANALISIS SISMICO ......................................................................................................... 38
10. ANALISIS DE IIREGULARIDADES ................................................................................. 43
10.1 IRREGULARIDAD EN PLANTA ................................................................................. 43
10.2 IRREGULARIDAD EN ALTURA ................................................................................. 45
10.3. ANALISIS POR AUSENCIA DE REDUNDANCIA ..................................................... 48
11. PARAMETROS SISMICOS ............................................................................................ 49
12. COMBINACIONES DE CARGA ..................................................................................... 49
13. CHEQUEO DERIVAS .................................................................................................... 50
14. DISEÑO POR ESTADO LIMITE DE RESISTENCIA .......................................................... 51
14.1. DISEÑO DE MAMPOSTERIA ................................................................................ 51
14.2. DISEÑO DE VIGAS CIMENTACION....................................................................... 54
14.3. DISEÑO DE DINTELES .......................................................................................... 58

10/01/2017. VERSION 01
2 DE 106
MEMORIAS DE CÁLCULO

14.4. DISEÑO DE CORREA ............................................................................................ 58


14.5. DISEÑO DE PLACA CIMENTACION ...................................................................... 64
14.6. DISEÑO DE PLACA MACIZA ENTREPISO.............................................................. 68
14.7. DISEÑO DE PLACA MACIZA TANQUE .................................................................. 73
14.8. DISEÑO DE ESCALERA ......................................................................................... 74
14.9. REACCIONES EN LA BASE.................................................................................... 76
14.10. DISEÑO DE ELEMENTOS NO ESTRUCTURALES ..................................................... 102

10/01/2017. VERSION 01
3 DE 106
MEMORIAS DE CÁLCULO

1. INTRODUCCIÓN

Se proyecta la construcción de una estructura de Un (1) nivel en el Municipio


de Mani la Nueva Departamento del Casanare.

La nueva estructura consta de un área 638.54 m2, con sistema estructural de


muros de mampostería parcialmente reforzada de bloque de perforación
vertical y de acuerdo a los requisitos sísmicos deberán diseñarse los
elementos para desarrollar una capacidad de disipación de energía
Moderada (DMO).

A continuación se presenta la memoria de cálculos estructurales

10/01/2017. VERSION 01
4 DE 106
MEMORIAS DE CÁLCULO

2. DESCRIPCION DEL ANALISIS

Se realizaron los estudios y diseños necesarios cumpliendo con todas las


normas vigentes del país. La estructura será planteada con un sistema
estructural de Muros de mamposteria que de acuerdo a los requisitos
sísmicos deberán diseñarse los elementos para desarrollar una capacidad
de disipación de energía Moderada (DMO) de la NSR-10.

En la estructura que se proyectó se va a implantar un sistema nuevo con


base en piezas de mampostería de perforación vertical, unidas por medio
de mortero reforzada internamente con barras y alambres de acero y que
cumple los requisitos del capitulo D de la NSR-10 (muros de mampostería
parcialmente reforzada construidos con unidades de perforación vertical).

Este sistema estructural se clasifica para efectos de diseño sismo-resistente.

10/01/2017. VERSION 01
5 DE 106
MEMORIAS DE CÁLCULO

3. NORMATIVAS

 Norma Colombiana Sismo Resistente NSR-10


 Decreto 926 de Marzo 14 de 2010
 Decreto 2525 de Julio 13 DE 2010
 Decreto 092 de Enero 17 de 2011
 Decreto 340 de Febrero 13 de 2012

10/01/2017. VERSION 01
6 DE 106
MEMORIAS DE CÁLCULO

4. PREDIMENSIONAMIENTO DE LOS ELEMENTOS


ESTRUCTURALES.
4.1 REQUISITOS GEOMETRICOS PARA VIGAS DE CIMENTACIÓN.

MINIMA - DMI MODERADA - DMO ESPECIAL - DES

Las vigas de amarre Las vigas de amarre Las vigas de amarre


deben tener una sección deben tener una sección deben tener una sección
tal que su mayor tal que su mayor tal que su mayor
dimensión debe ser la dimensión debe ser la dimensión debe ser la
mayor o igual a: mayor o igual a: mayor o igual a:
L/20 L/30 L/40

Dimensiones de secciones de vigas de cimentación asumidas


PROYECTO VI S MANI No. PROYECTO: 088-017

LOCALIZACIÓN
DEPAR TAMENTO: CASANARE
MUNICIPIO: Maní
CODIGO: 85139
ZONA DE AMENAZA SISMICA: Intermedia
CAP. DE DISIPACION DE ENER GIA: CAP. DE DISCIPACION DE ENERGIA MODERADA (DMO)

SECCIONES MINIMA VIGAS DE CIMENTACIÓN

LUZ ENTR E APOY OS: 9.00m


SECCION MINIMA VIGA: bw= 0.30m (Según C.15.13.3.1) bw= 0.25m
SECCION DE DISEÑO:
h= 0.30m (Según C.15.13.3.1) h= 0.25m

10/01/2017. VERSION 01
7 DE 106
MEMORIAS DE CÁLCULO

5. MATERIALES Y COEFICIENTES DE SEGURIDAD


5.1 MATERIALES

MAMPOSTERIA:

LADRILLO ESTRUCTURAL DE PERFORACION VERTICA DOBLE PARED

Tipo Mortero de Pega S

f'cu = 232 Kg/cm2 f´mCV= 115.93 Kg/cm2


f'cp = 125 Kg/cm2 f´mLl= 108.6 Kg/cm2
f'cr = 140 Kg/cm2

Material de las Unidades Arcilla

 Concreto Cimentacion, vigas cintas f´c=21MPa.

Aceros de refuerzo:
 Acero para barras de refuerzo  fy=420MPa.
 Acero para barras de refuerzo  fy=240MPa.

5.2 COEFICIENTES DE SEGURIDAD

 Secciones controladas por tracción = 0.90

 Secciones controladas por compresión

- Elementos con refuerzo en espiral según C.10.9.3 = 0.75

- Otros elementos reforzados = 0.65

Para las secciones en que la deformación unitaria neta a la tracción en el


acero extremo a tracción en el estado de resistencia nominal, εt, se
encuentra entre los limites para secciones controladas por compresión y las

10/01/2017. VERSION 01
8 DE 106
MEMORIAS DE CÁLCULO

secciones controladas por tracción, se permite que aumente linealmente


desde el valor correspondiente a las secciones controladas por compresión
hasta 0.90, en la medida que εtaumente desde el límite de deformación
unitaria controlado por compresión hasta 0.005.

En forma alternativa, cuando se usa el Apéndice C-B, para elementos en los


cuales fyno exceda 420 MPa, con refuerzo simétrico, y cuando (d-d')/h no es
menor de 0.7, se permite aumentar linealmente hasta 0.90 en la medida
quePn disminuye de 0.10 fcAg hasta cero. Para otros elementos reforzados
 puede incrementarse linealmente a 0.90 en la medida que Pn disminuye
desde 0.10 fcAg o Pb, el que sea menor, hasta cero.

 Cortante y torsión = 0.75

 Aplastamiento en el concreto (excepto para anclajes de postensado


y modelos puntal – tensor) = 0.65

10/01/2017. VERSION 01
9 DE 106
MEMORIAS DE CÁLCULO

6. EVALUACIÓN DE CARGAS
6.1 EVALUACIÓN DE CARGAS ENTREPISO
AVALUO DE CARGAS TITULO B.3 NSR - 10

Placa Maciza en concreto reforzado

Lmax= 4m
Condicion de Apoyo: simplemente apoyada

0.10

Placa Maciza: 0.24 Ton/m2


2
Muros Internos: 0.000 Ton/m

Cielo raso Tabla B.3.4.1-1 0.52


1.248
Canales suspendidas de acero 0.01 Ton/m 2
0.432

Acabados de Piso Tabla B.3.4.1-3


Baldosa ceramica sobre 25mm de 0.110 Ton/m 2
mortero

D 0.36 Ton/m2

Carga Viva Tabla B.4.2.1-1


Ocupacion Residencial

Uso Cuartos Privados y Corredores


Carga Viva m2 L 0.18 Ton/m2

Uso Balcones
Carga Viva m2 L 0.5 Ton/m2

Uso Escaleras
Carga Viva m2 L 0.3 Ton/m2

10/01/2017. VERSION 01
10 DE 106
MEMORIAS DE CÁLCULO

6.2 EVALUACIÓN DE CARGAS CUBIERTA


AVALUO DE CARGAS TITULO B.3 NSR - 10

Cubierta Liviana

15 °

Cubierta Tabla B.3.4.1-4


cubiertas corrugadas de asbesto-
0.02 Ton/m 2
cemento

Cielo raso Tabla B.3.4.1-1

0.025 Ton/m 2
pañete en yeso o concreto

D 0.045 Ton/m2

Carga Viva Tabla B.4.2.1-1


Ocupacion Residencial

Uso Cuartos Privados y Corredores


Carga Viva m2 L 0.035 Ton/m2

10/01/2017. VERSION 01
11 DE 106
MEMORIAS DE CÁLCULO

7. DATOS DE ENTRADA Y SALIDA DEL MODELO MATEMATICO

Datos de Entrada generales de Mamposteria

DATOS GENERALES MAMPOSTERIA ESTRUCTURAL

ESTIMACION DEL VALOR DE f´m BASADO EN LA RESISTENCIA DE LOS


MATERIALES D.3.7.5

LADRILLO ESTRUCTURAL DE PERFORACION VERTICA DOBLE PARED

Tipo Mortero de Pega S

f'cu = 232 Kg/cm2 h= 23 cm


2
f'cp = 125 Kg/cm L= 33 cm
2
f'cr = 140 Kg/cm b = 11.5 cm

Material de las Unidades Arcilla

Kp= 0.8
Kr= 0.75

 2h   50 Kp 
Rm    f ´cu    f ´cp  0.8 f ´cu
 75  3h   75  3h 

Rm= 154.57 Kg/cm2

10/01/2017. VERSION 01
12 DE 106
MEMORIAS DE CÁLCULO

Para muros con todas las celdas vacias Para muros con todas las celdas llenas

f ´m  0.75 * Rm f ´m  0.75 * r * Rm  0.9 * Kr * 1  r  f ´cr   0.94 Rm


Area netaceldasrellenas
1  r  
f´m CV= 115.93 Kg/cm 2 Area neta unidad
r
Area bruta Areabruta
r= 0.86 (1-r)= 0.13

f´m Ll = 108.65 Kg/cm 2

Modulo de Elasticidad de la Mamposteria

Para unidades de arcilla : Para unidades de concreto :


Em  750 * f ´m  20000 MPa Em  900 * f ´m  20000 MPa
Em= 81487 Kg/cm 2
Gm= 32595 Kg/cm2

10/01/2017. VERSION 01
13 DE 106
MEMORIAS DE CÁLCULO

10/01/2017. VERSION 01
14 DE 106
MEMORIAS DE CÁLCULO

10/01/2017. VERSION 01
15 DE 106
MEMORIAS DE CÁLCULO

10/01/2017. VERSION 01
16 DE 106
MEMORIAS DE CÁLCULO

10/01/2017. VERSION 01
17 DE 106
MEMORIAS DE CÁLCULO

10/01/2017. VERSION 01
18 DE 106
MEMORIAS DE CÁLCULO

10/01/2017. VERSION 01
19 DE 106
MEMORIAS DE CÁLCULO

10/01/2017. VERSION 01
20 DE 106
MEMORIAS DE CÁLCULO

10/01/2017. VERSION 01
21 DE 106
MEMORIAS DE CÁLCULO

10/01/2017. VERSION 01
22 DE 106
MEMORIAS DE CÁLCULO

10/01/2017. VERSION 01
23 DE 106
MEMORIAS DE CÁLCULO

10/01/2017. VERSION 01
24 DE 106
MEMORIAS DE CÁLCULO

10/01/2017. VERSION 01
25 DE 106
MEMORIAS DE CÁLCULO

10/01/2017. VERSION 01
26 DE 106
MEMORIAS DE CÁLCULO

10/01/2017. VERSION 01
27 DE 106
MEMORIAS DE CÁLCULO

10/01/2017. VERSION 01
28 DE 106
MEMORIAS DE CÁLCULO

10/01/2017. VERSION 01
29 DE 106
MEMORIAS DE CÁLCULO

10/01/2017. VERSION 01
30 DE 106
MEMORIAS DE CÁLCULO

10/01/2017. VERSION 01
31 DE 106
7.1. IMÁGENES DEL MODELO MATEMATICO

Ilustración 1: Vista en planta Base


Ilustración 2: Vista en planta Piso 2
Ilustración 3: Vista en planta Piso 3
MEMORIAS DE CÁLCULO

Ilustración 4: Vista en planta Cubierta

10/01/2017. VERSION 01
35 DE 106
Ilustración 5: Vista en 3D
MEMORIAS DE CÁLCULO

8. ANALISIS ESTRUCTURAL
La determinación de las acciones de diseño bajo el efecto de las cargas
dadas en los capítulos anteriores se realiza bajo un modelo matemático
espacial con seis grados de libertad por nudo resuelto utilizando el programa
RCB versión 8.5, a continuación se presenta una vista espacial del modelo
construido bajo el programa.

Ilustración 6: Vista del modelo matemático en 3D

10/01/2017. VERSION 01
37 DE 106
MEMORIAS DE CÁLCULO

9. ANALISIS SISMICO

10/01/2017. VERSION 01
38 DE 106
MEMORIAS DE CÁLCULO

10/01/2017. VERSION 01
39 DE 106
MEMORIAS DE CÁLCULO

10/01/2017. VERSION 01
40 DE 106
MEMORIAS DE CÁLCULO

10/01/2017. VERSION 01
41 DE 106
MEMORIAS DE CÁLCULO

10/01/2017. VERSION 01
42 DE 106
MEMORIAS DE CÁLCULO

10.ANALISIS DE IIREGULARIDADES
10.1 IRREGULARIDAD EN PLANTA
CHEQUEO DE LAS IRREGULARIDADES DE LA ESTRUCTURA
PROYECTO VIS MANI
LOCALIZACION MANI
TABLA A.3-6 IRREGULARIDADES EN PLANTA
TIPO DESCRIPCION DE LA IRREGULARIDAD EN PLANTA
Irregularidad torsional — La irregularidad torsional X NO
existe cuando en una edificación con diafragma rígido, X
la máxima deriva de piso de un extremo de la
DIRECCION
estructura, calculada incluyendo la torsión accidental
X Y
y medida perpendicularmente a un eje determinado,
1aP es más de 1.2 y menor o igual a 1.4 veces la deriva
promedio de los dos extremos de la estructura, con Φ px 1.00
respecto al mismo eje de referencia. Φ py 1.00
La estructura no presenta
irregularidad en planta tipo 1aP

Irregularidad torsional extrema — La irregularidad SI NO


torsional extrema existe cuando en una edificación
con diafragma rígido, la máxima deriva de piso de un
DIRECCION
extremo de la estructura, calculada incluyendo la
X Y
torsión accidental y medida perpendicularmente a un
1bP eje determinado, es más de 1.4 veces la deriva
promedio de los dos extremos de la estructura, con Φ px 1.00
respecto al mismo eje de referencia. Φ py 1.00
La estructura no presenta
irregularidad en planta tipo 1bP

Retrocesos excesivos en las esquinas — La A 0.00


configuración de una estructura se considera B 0.00
irregular cuando ésta tiene retrocesos excesivos en
C 0.00
sus esquinas. Un retroceso en una esquina se
D 0.00
2P considera excesivo cuando las proyecciones de la
estructura, a ambos lados del retroceso, son mayores
que el 15 por ciento de la dimensión de la planta de la Φp 1.00
estructura en la dirección del retroceso. La estructura no presenta
irregularidad en planta tipo 2P

Discontinuidades en el diafragma — Cuando el A 0.00


diafragma tiene discontinuidades apreciables o B 0.00
variaciones en su rigidez, incluyendo las
C 0.00
causadas por aberturas, entradas, retrocesos o
D 0.00
3P huecos con áreas mayores al 50 por ciento del área
bruta del diafragma o existen cambios en la rigidez E 0.00
efectiva del diafragma de más del 50 por ciento, entre Φp 1.00
niveles consecutivos, la estructura se considera La estructura no presenta
irregular. irregularidad en planta tipo 3P

Desplazamientos del plano de acción de SI NO


elementos verticales — La estructura se considera
irregular cuando existen discontinuidades en las
DIRECCION
trayectorias de las fuerzas inducidas por los efectos
X Y
sísmicos, tales como cuando se traslada el plano que
4P contiene a un grupo de elementos verticales del
sistema de resistencia sísmica, en una dirección Φ px 1.00
perpendicular a él, generando un nuevo plano. Los Φ py 1.00
altillos o manzardas de un solo piso se eximen de La estructura no presenta
este requisito en la consideración de irregularidad. irregularidad en planta tipo 4P

Sistemas no paralelos — Cuando las direcciones de SI NO


acción horizontal de los elementos verticales del
sistema de resistencia sísmica no son paralelas o
DIRECCION
simétricas con respecto a los ejes ortogonales
X Y
horizontales principales del sistema de resistencia
5P sísmica, la estructura se considera irregular.
Φ px 1.00
Φ py 1.00
La estructura no presenta
irregularidad en planta tipo 5P

Φ px 1.00
Φ py 1.00

10/01/2017. VERSION 01
43 DE 106
MEMORIAS DE CÁLCULO

10/01/2017. VERSION 01
44 DE 106
MEMORIAS DE CÁLCULO

10.2 IRREGULARIDAD EN ALTURA

TABLA A.3-7 IRREGULARIDADES EN ALTURA


TIPO DESCRIPCION DE LA IRREGULARIDAD EN ALTURA
Piso flexible (Irregularidad en rigidez) — Cuando la SI NO
rigidez ante fuerzas horizontales de un piso es menor X
del 70 por ciento pero superior o igual al 60
DIRECCION
por ciento de la rigidez del piso superior o menor del
X Y
80 por ciento pero superior o igual al 70 por ciento del
1aA promedio de la rigidez de los tres pisos superiores, la
estructura se considera irregular. Φ ax 1.00
Φ ay 1.00
La estructura no presenta
irregularidad en planta tipo 1aA

Piso flexible (Irregularidad extrema en rigidez) — SI NO


Cuando la rigidez ante fuerzas horizontales de un piso X
es menor del 60 por ciento de la rigidez del piso
DIRECCION
superior o menor del 70 por ciento del promedio de la
X Y
rigidez de los tres pisos superiores, la estructura se
1bA considera irregular.
Φ ax 1.00
Φ ay 1.00
La estructura no presenta
irregularidad en planta tipo 1bA

Irregularidad en la di str i bución d e l a s SI NO


ma sas — Cuando la masa, mi , de cualquier piso es X
mayor que 1.5 veces la masa de uno de los pisos
2A contiguos, la estructura se considera irregular. Se
Φa 1.00
exceptúa el caso de cubiertas que sean más livianas
que el piso de abajo. La estructura no presenta
irregularidad en planta tipo 2A

Irregularidad geométri c a — Cuando la dimensión Ax 0.00


horizontal del sistema de resistencia sísmica en Bx 0.00
cualquier piso es mayor que 1.3 veces la misma
Ay 0.00
dimensión en un piso adyacente, la estructura se
By 0.00
3A considera irregular. Se exceptúa el caso de los
altillos de un solo piso. Φ ax 1.00
Φ ay 1.00
La estructura no presenta
irregularidad en planta tipo 3A

Desplazamientos dentro del plano de acción — La Ax 0.00


estructura se considera irregular cuando existen Bx 0.00
desplazamientos en el alineamiento de elementos
Ay 0.00
verticales del sistema de resistencia sísmica, dentro
By 0.00
del mismo plano que los contiene, y estos
4A desplazamientos son mayores que la dimensión
horizontal del elemento. Cuando los elementos Φ ax 1.00
desplazados solo sostienen la cubierta de la Φ ay 1.00
edificación sin otras cargas adicionales de tanques o La estructura no presenta
equipos, se eximen de esta consideración de irregularidad en planta tipo 4A
irregularidad.
Piso débil — Discontinuidad en la resistencia — R piso Bx 0.00
Cuando la resistencia del piso es menor del 80 por R piso Cx 0.00
ciento de la del piso inmediatamente superior pero
R piso By 0.00
superior o igual al 65 por ciento, entendiendo la
R piso Cy 0.00
5aA resistencia del piso como la suma de las resistencias
de todos los elementos que comparten el cortante del Φ ax 1.00
piso para la dirección considerada, la estructura se Φ ay 1.00
considera irregular. La estructura no presenta
irregularidad en planta tipo 5aA

Piso débil — Discontinuidad extrema en la R piso Bx 0.00


resistencia — Cuando la resistencia del piso es R piso Cx 0.00
menor del 65 por ciento de la del piso inmediatamente
R piso By 0.00
superior, entendiendo la resistencia del piso como la
R piso Cy 0.00
5bA suma de las resistencias de todos los elementos que
comparten el cortante del piso para la dirección Φ ax 1.00
considerada, la estructura se considera irregular. Φ ay 1.00
La estructura no presenta
irregularidad en planta tipo 5bA

Φ ax 1.00
Φ ay 1.00

10/01/2017. VERSION 01
45 DE 106
MEMORIAS DE CÁLCULO

10/01/2017. VERSION 01
46 DE 106
MEMORIAS DE CÁLCULO

10/01/2017. VERSION 01
47 DE 106
MEMORIAS DE CÁLCULO

10.3. ANALISIS POR AUSENCIA DE REDUNDANCIA


TABLA A.3-7 IRREGULARIDAD POR AUSENCIA DE REDUNDANCIA
TIPO DESCRIPCION DE LA IRREGULARIDAD POR AUSENCIA DE REDUNDANCIA
SI NO
X

En edificaciones con un sistema estructural con capacidad de disipación de energía DIRECCION


mínima (DMI) — Para edificaciones cuyo sistema estructural de resistencia sísmica es X Y
A.3.3.8.1 de un material que cumple los requisitos de capacidad de disipación de energía mínima (DMI)
el valor del factor de reducción de resistencia por ausencia de redundancia en el sistema Φ rx 1.00
estructural de resistencia sísmica, φr , se le asigna un valor de la unidad Φr=1.0 Φ ry 1.00
La estructura no presenta
ausencia de redundancia

(a). En sistemas compuestos por pórticos con DIRECCION


arriostramientos concéntricos — La falla de X Y
cualquiera de las diagonales o sus conexiones al
pórtico no resulta en una reducción de más del 33 por
Φ rx 1.00
ciento de la resistencia ante fuerzas horizontales
En edificaciones con un sistema del piso ni produce una irregularidad torsional en Φ ry 1.00
estructural con capacidad de planta extrema (Tipo 1bP). La estructura no presenta
disipación de energía moderada ausencia de redundancia
(DMO) y especial (DES) — Para (b). En sistemas compuestos por pórticos con DIRECCION
edificaciones cuyo sistema arriostramientos excéntricos — La pérdida de
X Y
resistencia a momento (si se trata de vínculos a
estructural es de un material que
momento), o a cortante (para el caso de vínculos a corte),
cumple los requisitos de capacidad de los dos extremos de un vínculo no resulta en una Φ rx 1.00
de disipación de energía moderada reducción de más del 33 por ciento de la resistencia Φ ry 1.00
(DMO) o especial (DES) el valor del ante fuerzas horizontales del piso ni produce una
La estructura no presenta
factor de reducción de irregularidad torsional en planta extrema (Tipo 1bP). ausencia de redundancia
resistencia por ausencia de
(c). En sistemas de pórtico resistente a momentos DIRECCION
redundancia en el sistema — La pérdida de la resistencia a momento en la X Y
estructural de resistencia sísmica, conexión viga-columna de los dos extremos de una
φ , se le puede asignar un valor de viga no resulta en una reducción de más del 33 por
Φ rx 1.00
la unidad (Φr=1.0 ) cuando en ciento de la resistencia ante fuerzas horizontales del
A.3.3.8.2 todos los pisos que resistan más piso ni produce una irregularidad torsional en planta Φ ry 1.00
del 35 por ciento del corte basal extrema (Tipo 1bP). La estructura no presenta
ausencia de redundancia
en la dirección bajo estudio el
(d). En sistem as con m uros estructurales de DIRECCION
sistema estructural de resistencia
concreto estructural — La falla de un muro estructural o
sísmica cumpla las siguientes X Y
de una porción de él que tengan una relación de la altura
condiciones de redundancia: del piso a su longitud horizontal mayor de la unidad, o de
los elementos colectores que lo conectan al diafragma, no Φ rx 1.00
resulta en una reducción de más del 33 por ciento de la
Φ ry 1.00
resistencia ante fuerzas horizontales del piso ni produce una
irregularidad torsional en planta extrema (Tipo 1bP). La estructura no presenta
ausencia de redundancia

En los sistemas estructurales que no cumplan las condiciones enunciadas en (a) a (d) el factor de reducción de resistencia por ausencia SI NO
de redundancia en el sistema estructural de resistencia sísmica, φr , se le debe asignar un valor de φr=0.75. Aunque no se cumplan X
las condiciones enunciadas en (a) a (d) el factor de reducción de resistencia por ausencia de redundancia en el sistema estructural
DIRECCION
de resistencia sísmica, φr , se le debe asignar un valor igual a la unidad ( φr=1.0 ), si todos los pisos que resistan más del 35 por ciento
X Y
del corte basal en la dirección bajo estudio el sistema estructural de resistencia sísmica sean regulares en planta y tengan al menos dos
vanos compuestos por elementos que sean parte del sistema de resistencia sísmica localizados en la periferia a ambos lados de la
planta en las dos direcciones principales. Cuando se trate de muros estructurales para efectos de contar el número de vanos Φ rx 1.00
equivalentes se calcula como la longitud horizontal del muro dividida por la altura del piso. Φ ry 1.00
La estructura no presenta
ausencia de redundancia

Φ rx 1.00
Φ ry 1.00

10/01/2017. VERSION 01
48 DE 106
MEMORIAS DE CÁLCULO

11. PARAMETROS SISMICOS

12. COMBINACIONES DE CARGA


COMBINACIONES DE CARGA PARA DISEÑO DE MAMPOSTERIA

D L S.X. S.Y.
COMB1 1.2 + 1.6
COMB2 0.9 + + 0.5
COMB3 0.9 + + + 0.5
COMB4 0.9 + - 0.5 +
COMB5 0.9 + + - 0.5

10/01/2017. VERSION 01
49 DE 106
MEMORIAS DE CÁLCULO

13. CHEQUEO DERIVAS

10/01/2017. VERSION 01
50 DE 106
14. DISEÑO POR ESTADO LIMITE DE RESISTENCIA
14.1. DISEÑO DE MAMPOSTERIA
Mampostería Reforzada (DMO) PISO 1 Unidades P (T) , M (T- m), V (T), n (Kg/cm2), A s (cm2)

Cubierta:

Ladrillo tipo 3 LADRIBLOCK Ladrillo tipo 3 LADRIBLOCK


2 2
f' m = 108.65 Kg/cm h= 23 cm f' m = 108.65 Kg/cm h= 23 cm
f y = 4200 Kg/cm2 L= 33 cm f y = 4200 Kg/cm2 L= 33 cm
As min = 0.0007 x 100 x 11.5 b= 11.5 cm As min = 0.0007 x 100 x 11.5 b= 11.5 cm
2 2
As min.= 0.81 cm /m d' = 15 cm As min.= 0.81 cm /m d' = 15 cm
 = 0.60 h' = 250 cm  = 0.60 h' = 250 cm
j = 0.60 j = 0.60

 5 mm = 0.196 cm2 Hiladas= 0.23 m  5 mm = 0.196 cm2 Hiladas= 0.23 m


Horizontal: Horizontal:
2  5.0 mm c/ 2 Hiladas = 2 x 0.196 0.46 = 0.85 2  5.0 mm c/ 2 Hiladas = 2 x 0.196 0.46 = 0.85

Esfuerzo límite de Flexo-compresión = 0.2 x f'm = 21.73


Kg/cm2 Esfuerzo límite de Flexo-compresión = 0.2 x f'm = 21.72993
Kg/cm2

Sentido X
Pn(1) El menor valor entre 0.10 f' m A e y 0.25 Pb No.
Pn(2)  0.80 P0 Re Celdas Corte Flexión cada extremo Elemento de Borde
Redistribución Rellenas Ref.
Mu en cada Axial limite A s /m Horiz. As Refuerzo Vertical
Esfuerzo
Necesita
Ladrillo
Muro
Tipo
Pn(1)  Pu Mu Vu L nu %M %V %M %V Mu Vu
(V u d )
Vm extremo Pn(2) Tipo Kg/cm
2

M-1 3 3.4 0.70 2.10 0.80 0.30 0.64 1.70 0.5 0.8 0.5 0.8 0.8 0.3 5.44 1.3 1 19.0 0.81 3 0.65 1No.4 14.49 No
M-2 3 3.4 0.74 1.50 0.50 0.30 0.64 1.70 0.3 0.8 0.3 0.8 0.5 0.3 3.40 1.3 1 20.2 0.81 3 0.65 1No.4 9.39 No
M-3 3 4.5 0.66 3.40 0.70 0.30 0.80 1.28 0.4 0.8 0.4 0.8 0.7 0.3 3.59 1.6 1 22.0 0.81 3 0.65 1No.4 11.46 No
M-4 3 11.4 0.75 4.70 7.10 3.50 1.80 5.89 4.4 9.0 4.4 9.0 7.1 3.5 1.23 3.6 1 55.6 0.81 3 1.35 1No.5 19.19 No
M-5 3 11.0 0.75 4.20 3.60 1.10 1.74 1.92 2.2 2.8 2.2 2.8 3.6 1.1 2.06 3.5 1 51.6 0.81 3 0.65 1No.4 11.75 No
M-6 3 11.0 0.75 4.20 3.60 1.10 1.74 1.92 2.2 2.8 2.2 2.8 3.6 1.1 2.06 3.5 1 54.2 0.81 3 1.29 1No.4 11.75 No
M-7 3 13.0 0.75 5.40 7.60 3.00 2.03 4.43 4.7 7.8 4.7 7.8 7.6 3.0 1.35 4.1 1 63.2 0.81 3 1.65 1No.5 17.24 No
M-8 3 25.1 0.68 17.00 25.40 6.00 3.85 4.50 15.8 15.5 15.8 15.5 25.4 6.0 1.14 7.7 1 108.8 0.81 3 3.00 1No.4+1No.5 20.91 No
M-9 3 25.1 0.68 17.30 26.00 4.40 3.85 3.30 16.2 11.4 16.2 11.4 26.0 4.4 1.60 7.7 1 108.3 0.81 3 3.00 1No.4+1No.5 21.37 No
M-10 3 43.3 0.75 17.00 23.60 4.90 6.64 2.10 14.7 12.7 14.7 12.7 23.6 4.9 0.74 17.7 1 206.5 0.81 3 5.00 4No.4 8.82 No
M-11 3 8.3 0.60 8.60 0.80 0.30 1.35 0.69 0.5 0.8 0.5 0.8 0.8 0.3 2.22 2.7 1 33.5 0.81 3 1.00 1No.4 11.56 No
M-12 3 8.1 0.66 6.30 1.30 0.80 1.32 1.90 0.8 2.1 0.8 2.1 1.3 0.8 1.39 2.6 1 35.8 0.81 3 1.00 1No.4 11.35 No
M-13 3 18.8 0.78 5.50 3.90 1.20 2.88 1.22 2.4 3.1 2.4 3.1 3.9 1.2 1.19 5.8 1 93.1 0.81 3 2.29 2No.4 6.55 No
M-14 3 18.1 0.74 8.30 4.00 1.50 2.77 1.59 2.5 3.9 2.5 3.9 4.0 1.5 1.02 5.5 1 85.1 0.81 3 2.29 2No.4 8.54 No
M-15 3 9.0 0.66 6.90 0.80 0.40 1.45 0.85 0.5 1.0 0.5 1.0 0.8 0.4 1.54 2.9 1 40.2 0.81 3 1.29 1No.4 9.11 No
M-16 3 46.5 0.68 30.70 23.50 5.20 7.13 2.07 14.7 13.4 14.7 13.4 23.5 5.2 0.65 20.7 1 204.4 0.81 3 6.00 3No.5 11.01 No
M-17 3 46.5 0.69 29.30 27.20 4.40 7.13 1.75 17.0 11.4 17.0 11.4 27.2 4.4 0.89 16.4 1 206.6 0.81 3 6.00 3No.5 11.34 No
MEMORIAS DE CÁLCULO

Mampostería Reforzada (DMO) PISO 2 Unidades P (T) , M (T- m), V (T), n (Kg/cm2), A s (cm2)

Cubierta:

Ladrillo tipo 3 LADRIBLOCK Ladrillo tipo 3 LADRIBLOCK


2 2
f' m = 108.65 Kg/cm h= 23 cm f' m = 108.65 Kg/cm h= 23 cm
2 2
fy = 4200 Kg/cm L= 33 cm fy = 4200 Kg/cm L= 33 cm
As min = 0.0007 x 100 x 11.5 b= 11.5 cm As min = 0.0007 x 100 x 11.5 b= 11.5 cm
2 2
As min.= 0.81 cm /m d' = 15 cm As min.= 0.81 cm /m d' = 15 cm
 = 0.60 h' = 250 cm  = 0.60 h' = 250 cm
j = 0.60 j = 0.60

 5 mm = 0.196 cm2 Hiladas= 0.23 m  5 mm = 0.196 cm2 Hiladas= 0.23 m


Horizontal: Horizontal:
2  5.0 mm c/ 2 Hiladas = 2 x 0.196 0.46 = 0.85 2  5.0 mm c/ 2 Hiladas = 2 x 0.196 0.46 = 0.85

Esfuerzo límite de Flexo-compresión = 0.2 x f'm = 21.73


Kg/cm2 Esfuerzo límite de Flexo-compresión = 0.2 x f'm = 21.72993
Kg/cm2

Sentido X
Pn(1) El menor valor entre 0.10 f' m A e y 0.25 Pb No.
Pn(2)  0.80 P0 Re Celdas Corte Flexión cada extremo Elemento de Borde
Redistribución Rellenas Ref.
en cada
Axial limite Esfuerzo
Ladrillo Mu A s /m Horiz. As Refuerzo Vertical Necesita
Muro
Tipo Pn(1)  Pu Mu Vu L nu %M %V %M %V Mu Vu
(V u d )
Vm extremo Pn(2) Tipo Kg/cm
2

M-1 3 3.4 0.78 1.00 0.20 0.10 0.64 0.57 0.2 0.3 0.2 0.3 0.2 0.1 4.08 1.3 1 21.3 0.81 3 0.65 1No.4 4.46 No
M-2 3 3.4 0.80 0.70 0.10 0.10 0.64 0.57 0.1 0.3 0.1 0.3 0.1 0.1 2.04 1.3 1 21.9 0.81 3 0.65 1No.4 2.58 No
M-3 3 4.5 0.75 1.80 0.10 0.10 0.80 0.43 0.1 0.3 0.1 0.3 0.1 0.1 1.54 1.6 1 25.0 0.81 3 0.65 1No.4 3.62 No
M-4 3 11.4 0.79 2.70 6.20 3.90 1.80 6.57 6.2 10.1 6.2 10.1 6.2 3.9 0.96 3.8 1 58.9 0.81 3 1.35 1No.5 15.64 No
M-5 3 11.0 0.80 2.20 0.80 0.20 1.74 0.35 0.8 0.5 0.8 0.5 0.8 0.2 2.52 3.5 1 54.7 0.81 3 0.65 1No.4 3.64 No
M-6 3 11.0 0.80 2.20 0.90 0.20 1.74 0.35 0.9 0.5 0.9 0.5 0.9 0.2 2.83 3.5 1 57.5 0.81 3 1.29 1No.4 3.88 No
M-7 3 13.0 0.80 2.80 5.50 3.10 2.03 4.58 5.5 8.0 5.5 8.0 5.5 3.1 0.94 4.4 1 67.4 0.81 3 1.65 1No.5 11.68 No
M-8 3 25.1 0.75 9.90 16.90 6.90 3.85 5.18 17.0 17.9 17.0 17.9 16.9 6.9 0.66 11.0 1 120.1 0.81 3 3.00 1No.4+1No.5 13.35 No
M-9 3 25.1 0.76 8.80 13.90 4.30 3.85 3.23 14.0 11.1 14.0 11.1 13.9 4.3 0.87 9.0 1 121.8 0.81 3 3.00 1No.4+1No.5 11.24 No
M-10 3 43.3 0.80 8.80 15.50 4.90 6.64 2.10 15.6 12.7 15.6 12.7 15.5 4.9 0.49 22.0 1 219.5 0.81 3 5.00 4No.4 5.22 No
M-11 3 8.3 0.72 4.30 0.10 0.10 1.35 0.23 0.1 0.3 0.1 0.3 0.1 0.1 0.83 3.3 1 40.2 0.81 3 1.00 1No.4 4.70 No
M-12 3 8.1 0.76 2.80 1.30 1.00 1.32 2.37 1.3 2.6 1.3 2.6 1.3 1.0 1.11 2.6 1 41.7 0.81 3 1.00 1No.4 7.75 No
M-13 3 18.8 0.81 3.30 1.40 0.70 2.88 0.71 1.4 1.8 1.4 1.8 1.4 0.7 0.73 7.7 1 96.6 0.81 3 2.29 2No.4 3.05 No
M-14 3 18.1 0.79 4.30 2.30 1.30 2.77 1.38 2.3 3.4 2.3 3.4 2.3 1.3 0.68 7.9 1 91.5 0.81 3 2.29 2No.4 4.66 No
M-15 3 9.0 0.75 3.70 1.00 0.80 1.45 1.71 1.0 2.1 1.0 2.1 1.0 0.8 0.96 3.0 1 45.6 0.81 3 1.29 1No.4 6.70 No
M-16 3 46.5 0.75 18.10 16.40 6.00 7.13 2.39 16.5 15.5 16.5 15.5 16.4 6.0 0.39 25.4 1 224.6 0.81 3 6.00 3No.5 6.94 No
M-17 3 46.5 0.75 18.00 16.80 4.90 7.13 1.95 16.9 12.7 16.9 12.7 16.8 4.9 0.49 23.6 1 224.8 0.81 3 6.00 3No.5 6.98 No

10/01/2017. VERSION 01
52 DE 106
MEMORIAS DE CÁLCULO

Mampostería Reforzada (DMO) PISO 3 Unidades P (T) , M (T- m), V (T), n (Kg/cm2), A s (cm2)

Cubierta:

Ladrillo tipo 3 LADRIBLOCK Ladrillo tipo 3 LADRIBLOCK


2 2
f' m = 108.65 Kg/cm h= 23 cm f' m = 108.65 Kg/cm h= 23 cm
f y = 4200 Kg/cm2 L= 33 cm f y = 4200 Kg/cm2 L= 33 cm
As min = 0.0007 x 100 x 11.5 b= 11.5 cm As min = 0.0007 x 100 x 11.5 b= 11.5 cm
2 2
As min.= 0.81 cm /m d' = 15 cm As min.= 0.81 cm /m d' = 15 cm
 = 0.60 h' = 250 cm  = 0.60 h' = 250 cm
j = 0.60 j = 0.60

 5 mm = 0.196 cm2 Hiladas= 0.23 m  5 mm = 0.196 cm2 Hiladas= 0.23 m


Horizontal: Horizontal:
2  5.0 mm c/ 2 Hiladas = 2 x 0.196 0.46 = 0.85 2  5.0 mm c/ 2 Hiladas = 2 x 0.196 0.46 = 0.85

Esfuerzo límite de Flexo-compresión = 0.2 x f'm = 21.73


Kg/cm2 Esfuerzo límite de Flexo-compresión = 0.2 x f'm = 21.72993
Kg/cm2

Sentido X
Pn(1) El menor valor entre 0.10 f' m A e y 0.25 Pb No.
Pn(2)  0.80 P0 Re Celdas Corte Flexión cada extremo Elemento de Borde
Redistribución Rellenas Ref.
en cada
Axial limite Esfuerzo
Ladrillo Mu A s /m Horiz. As Refuerzo Vertical Necesita
Muro
Tipo Pn(1)  Pu Mu Vu L nu %M %V %M %V Mu Vu
(V u d )
Vm extremo Pn(2) Tipo
Kg/cm
2

M-1 3 3.4 0.84 0.20 0.10 0.10 0.64 0.57 0.2 0.4 0.2 0.4 0.1 0.1 2.04 1.3 1 22.9 0.81 3 0.65 1No.4 1.70 No
M-2 3 3.4 0.84 0.20 0.10 0.10 0.64 0.57 0.2 0.4 0.2 0.4 0.1 0.1 2.04 1.3 1 22.9 0.81 3 0.65 1No.4 1.70 No
M-3 3 4.5 0.83 0.30 0.10 0.10 0.80 0.43 0.2 0.4 0.2 0.4 0.1 0.1 1.54 1.6 1 27.8 0.81 3 0.65 1No.4 1.36 No
M-4 3 11.4 0.84 0.60 3.40 2.30 1.80 3.87 6.5 9.9 6.5 9.9 3.4 2.3 0.90 4.1 1 62.3 0.81 3 1.35 1No.5 7.88 No
M-5 3 11.0 0.84 0.40 0.60 0.40 1.74 0.70 1.1 1.7 1.1 1.7 0.6 0.4 0.94 3.7 1 57.4 0.81 3 0.65 1No.4 1.71 No
M-6 3 11.0 0.84 0.40 0.60 0.40 1.74 0.70 1.1 1.7 1.1 1.7 0.6 0.4 0.94 3.7 1 60.4 0.81 3 1.29 1No.4 1.71 No
M-7 3 13.0 0.84 0.40 2.60 1.80 2.03 2.66 5.0 7.8 5.0 7.8 2.6 1.8 0.77 5.3 1 71.3 0.81 3 1.65 1No.5 4.86 No
M-8 3 25.1 0.83 2.30 8.00 4.80 3.85 3.60 15.3 20.7 15.3 20.7 8.0 4.8 0.45 13.1 1 132.2 0.81 3 3.00 1No.4+1No.5 5.36 No
M-9 3 25.1 0.85 0.30 4.60 1.90 3.85 1.43 8.8 8.2 8.8 8.2 4.6 1.9 0.65 11.1 1 135.4 0.81 3 3.00 1No.4+1No.5 2.67 No
M-10 3 43.3 0.84 2.10 6.20 2.70 6.64 1.16 11.9 11.6 11.9 11.6 6.2 2.7 0.35 24.3 1 230.1 0.81 3 5.00 4No.4 1.75 No
M-11 3 8.3 0.82 1.00 0.10 0.10 1.35 0.23 0.2 0.4 0.2 0.4 0.1 0.1 0.83 3.3 1 45.7 0.81 3 1.00 1No.4 1.37 No
M-12 3 8.1 0.83 0.50 1.40 1.00 1.32 2.37 2.7 4.3 2.7 4.3 1.4 1.0 1.20 2.6 1 45.6 0.81 3 1.00 1No.4 5.77 No
M-13 3 18.8 0.83 1.20 0.40 0.20 2.88 0.20 0.8 0.9 0.8 0.9 0.4 0.2 0.73 7.7 1 99.9 0.81 3 2.29 2No.4 1.01 No
M-14 3 18.1 0.84 0.60 0.90 0.60 2.77 0.64 1.7 2.6 1.7 2.6 0.9 0.6 0.57 8.6 1 97.4 0.81 3 2.29 2No.4 1.23 No
M-15 3 9.0 0.82 1.00 0.60 0.40 1.45 0.85 1.1 1.7 1.1 1.7 0.6 0.4 1.15 2.9 1 50.2 0.81 3 1.29 1No.4 2.86 No
M-16 3 46.5 0.82 6.00 11.50 4.00 7.13 1.59 22.0 17.2 22.0 17.2 11.5 4.0 0.41 25.0 1 244.0 0.81 3 6.00 3No.5 3.36 No
M-17 3 46.5 0.81 6.80 11.00 2.30 7.13 0.92 21.1 9.9 21.1 9.9 11.0 2.3 0.69 20.0 1 242.8 0.81 3 6.00 3No.5 3.45 No

10/01/2017. VERSION 01
53 DE 106
14.2. DISEÑO DE VIGAS CIMENTACION
VIGAS DE AMARRE

1. Se asume una sección: Según la NSR-10 numeral C.15.13.3, las dimensiones de las vigas de amarre deben
establecerse en función de las solicitaciones que las afecten, dentro de las cuales se cuentan la resistencia
a fuerzas axiales por razones sísmicas y la rigidez y características para efectos de diferencias de carga ver-
tical sobre los elementos de cimentación y la posibilidad de ocurrencia de asentamientos totales y diferenciales.

Las vigas de amarre deben tener una sección tal que su mayor dimensión debe ser mayor o igual a L /20 para
estructuras DES, L /30 para estructuras DMO y L /40 para estructuras DMI, donde L es la luz del elemento.

b (cm) = 25
h (cm) = 25
d' (cm) = 7.5
d (cm) = 17.5
d/2 (cm) = 8.75

r = 0.0033 (minimo)

As = rbd
As = 1.44 cm² (Refuerzo positivo)
As = 1.44 cm² (Refuerzo negativo)

2. La viga debe ser capaz de transmitir de columna a columna un porcentaje de la carga que baja por la columna,
dicho porcentaje esta dado por 0.25Aa (Nsr-98 A.3.6.4.2) donde Aa = 0.10 Mani (Casanare)

0.25 Aa = 2.50%

Máxima carga real que baja por la columna = 22 Ton


Factor de carga = 1.3
Carga última = 28.6 Ton

La fuerza axial que debe ser capaz de transmitir la viga de amarre a la columna adyacente (Pu) es:

Pu = 0.7 Ton

El refuerzo que necesita la viga para resistir la fuerza axial es:

fy = 4200 kg/cm²
As = 0.19 cm² (Refuerzo para toda la sección)

3. El momento y el cortante que se generan cuando un elemento de cimentación sufre un asentamiento son:

M= 6EID V= 12EID
L2 L3
Donde :

E = módulo de elasticidad del concreto


f´c = 210 kg/cm²
Ec = 178720 kg/cm²

I = inercia de la sección (la mitad para tener en cuenta la fisuración) : I = bh3/24


4
I = 0.00016 m

D = máximo asentamiento permitido para que no se ocasionen daños a elementos importantes.


D = 0.01 m

L = Luz entre columnas


L = 4.00 m
MEMORIAS DE CÁLCULO

Luego:

M= 1.1 Ton - m V = 0.5 Ton


Mu = 1.4 Ton - m Vu = 0.7 Ton

Revisión de la sección asumida:

Flexión:

r= 0.0052 Sección asumida es adecuada

As = 2.28 cm² (Refuerzo positivo)


As = 2.28 cm² (Refuerzo negativo)

Cortante: utilizar flejes # 3 ó #4

ø Flejes = 1/4"
# de ramas = 2
As = 0.64 cm²
Separación = 20 cm La menor entre d/2 o 30 cm
ø Vc = 2.9 Ton
5ø Vc = 14.3 Ton Sección por cortante OK

Resiste = 4.9 Ton Cortante OK

Resumen dimensionamiento Viga de Amarre

b = 25 cm
h = @REDONDARRIBA(B92/10,0)*2;
25 cm 8; 6 2#4 Tras. Mín 0.50 m
f´c = 210 kg/cm²
fy = 4200 kg/cm² 10
As = 2.3 cm²
Flejes = 1/4" 0.1
Sep máx = 20 cm
10
Fl#3 L= 0.40

10/01/2017. VERSION 01
55 DE 106
MEMORIAS DE CÁLCULO

10/01/2017. VERSION 01
56 DE 106
MEMORIAS DE CÁLCULO

10/01/2017. VERSION 01
57 DE 106
MEMORIAS DE CÁLCULO

14.3. DISEÑO DE DINTELES

14.4. DISEÑO DE CORREA

10/01/2017. VERSION 01
58 DE 106
MEMORIAS DE CÁLCULO

10/01/2017. VERSION 01
59 DE 106
MEMORIAS DE CÁLCULO

10/01/2017. VERSION 01
60 DE 106
MEMORIAS DE CÁLCULO

10/01/2017. VERSION 01
61 DE 106
MEMORIAS DE CÁLCULO

10/01/2017. VERSION 01
62 DE 106
MEMORIAS DE CÁLCULO

10/01/2017. VERSION 01
63 DE 106
MEMORIAS DE CÁLCULO

14.5. DISEÑO DE PLACA CIMENTACION


i Piso CM CV r CV reducida CR
1 Tanques 0.52 0.18 1.00 0.180 0.70
2 Cub 0.045 0.035 1.00 0.035 0.08
3 Piso 3 0.35 0.18 1.00 0.180 0.53
4 Piso 2 0.35 0.18 1.00 0.180 0.53
Sumatoria 1.265 0.575 0.575 1.840

Esfuerzo de contacto 1.84 t/m2 1.84 t/m2


esfuerzo de admisible 9.8 t/m2 Ok! 9.8 t/m2 Ok!

2
Carga de diseño 1.2 CM + 1.6 CV = 1.49 t/m

10/01/2017. VERSION 01
64 DE 106
MEMORIAS DE CÁLCULO

PROYECTO: VIS MANI


DISEÑO PLACA MACIZA
CHEQUEO PLACA DE CIMETACIÓN

CU = 1.490
SELECCIÓN TIPO DE APOYO

DEFINICIÓN DE LOS APOYOS


4
1 2 APOYO 1: 3 EMPOTRADO
KL APOYO 2: 2 SIMPLE
3 APOYO 3: 3 EMPOTRADO
L APOYO 4: 3 EMPOTRADO

DEFINICION DE VARIABLES

L= 4.61 m F.M.= 1.00 L = Longitud mayor


KL = 2.15 m Qu = 1.490 t / m² KL = Longitud menor
K= 0.500 f'c = 210 kg/cm²
h placa = 0.12 m f'y = 4200 kg/cm²
d' = 0.03 m

DATOS DE DISEÑO

0.00 0.00 0.00 0.04 -0.06 -0.06


Refuerzo del
Refuerzo del apoyo 1
APOYO 1 APOYO 2 apoyo 3 al 4 APOYO 3 APOYO 4
al 2 (Luz 1-2)
(Luz 3-4)
M/qK2 L 2 o M/qL 2 0.0039 0.0000 -0.0020 0.0437 -0.0634 -0.0634
M ( t-m ) 0.123 0.000 -0.063 0.301 -0.437 -0.437
Cuantia r 0.00041 0.00000 0.00021 0.00099 0.00145 0.00145
Area Req(cm²/m) 0.36 0.00 0.19 0.90 1.31 1.31
Area Min.(cm²/m) 2.16 1.80 1.80 2.16 1.80 1.80
Area def. (cm²/m) 2.16 1.80 1.80 2.16 1.80 1.80
Refuerzo ø6.5mm c/15 ø6.0mm c/15 ø6.0mm c/15 ø6.5mm c/15 ø6.0mm c/15 ø6.0mm c/15
arriba abajo/apoyo
EMPOTRADO L= 4.61
ø6.0mm c/15
ø6.5mm c/15

KL= 2.15 ø6.0mm c/15 ø6.5mm c/15 ø6.0mm c/15

EMPOTRADO SIMPLE

ø6.0mm c/15
EMPOTRADO

10/01/2017. VERSION 01
65 DE 106
MEMORIAS DE CÁLCULO

PROYECTO: VIS MANI


DISEÑO PLACA MACIZA
CHEQUEO PLACA DE CIMETACIÓN

CU = 1.490
SELECCIÓN TIPO DE APOYO

DEFINICIÓN DE LOS APOYOS


4
1 2 APOYO 1: 3 EMPOTRADO
KL APOYO 2: 3 EMPOTRADO
3 APOYO 3: 3 EMPOTRADO
L APOYO 4: 3 EMPOTRADO

DEFINICION DE VARIABLES

L= 4.00 m F.M.= 1.00 L = Longitud mayor


KL = 3.00 m Qu = 1.490 t / m² KL = Longitud menor
K= 0.750 f'c = 210 kg/cm²
h placa = 0.12 m f'y = 4200 kg/cm²
d' = 0.03 m

DATOS DE DISEÑO

Refuerzo del apoyo Refuerzo del apoyo


APOYO 1 APOYO 2 APOYO 3 APOYO 4
1 al 2 (Luz 1-2) 3 al 4 (Luz 3-4)
M/qK2 L 2 o M/qL 2 0.0096 -0.0139 -0.0139 0.0319 -0.0462 -0.0462
M ( t-m ) 0.229 -0.331 -0.331 0.428 -0.620 -0.620
Cuantia r 0.00075 0.00110 0.00110 0.00142 0.00207 0.00207
Area Req(cm²/m) 0.68 0.99 0.99 1.28 1.87 1.87
Area Min.(cm²/m) 2.16 1.80 1.80 2.16 1.80 1.80
Area def. (cm²/m) 2.16 1.80 1.80 2.16 1.87 1.87
Refuerzo ø6.5mm c/15 ø6.0mm c/15 ø6.0mm c/15 ø6.5mm c/15 ø6.0mm c/15 ø6.0mm c/15
arriba abajo/apoyo
EMPOTRADO L= 4.00
ø6.0mm c/15
ø6.5mm c/15

KL= 3.00 ø6.0mm c/15 ø6.5mm c/15 ø6.0mm c/15

EMPOTRADO EMPOTRADO

ø6.0mm c/15
EMPOTRADO

10/01/2017. VERSION 01
66 DE 106
MEMORIAS DE CÁLCULO

PROYECTO: VIS MANI


DISEÑO PLACA MACIZA
CHEQUEO PLACA DE CIMETACIÓN

CU = 1.490
SELECCIÓN TIPO DE APOYO

DEFINICIÓN DE LOS APOYOS


4
1 2 APOYO 1: 3 EMPOTRADO
KL APOYO 2: 3 EMPOTRADO
3 APOYO 3: 3 EMPOTRADO
L APOYO 4: 3 EMPOTRADO

DEFINICION DE VARIABLES

L= 3.08 m F.M.= 1.00 L = Longitud mayor


KL = 1.68 m Qu = 1.490 t / m² KL = Longitud menor
K= 0.550 f'c = 210 kg/cm²
h placa = 0.12 m f'y = 4200 kg/cm²
d' = 0.03 m

DATOS DE DISEÑO

Refuerzo del apoyo 1 al Refuerzo del apoyo 3


APOYO 1 APOYO 2 APOYO 3 APOYO 4
2 (Luz 1-2) al 4 (Luz 3-4)
2 2 2
M/qK L o M/qL 0.0051 -0.0075 -0.0075 0.0407 -0.0591 -0.0591
M ( t-m ) 0.072 -0.106 -0.106 0.171 -0.249 -0.249
Cuantia r 0.00024 0.00035 0.00035 0.00056 0.00082 0.00082
Area Req(cm²/m) 0.21 0.31 0.31 0.51 0.74 0.74
Area Min.(cm²/m) 2.16 1.80 1.80 2.16 1.80 1.80
Area def. (cm²/m) 2.16 1.80 1.80 2.16 1.80 1.80
Refuerzo ø6.5mm c/15 ø6.0mm c/15 ø6.0mm c/15 ø6.5mm c/15 ø6.0mm c/15 ø6.0mm c/15
arriba abajo/apoyo
EMPOTRADO L= 3.08
ø6.0mm c/15
ø6.5mm c/15

KL= 1.68 ø6.0mm c/15 ø6.5mm c/15 ø6.0mm c/15

EMPOTRADO EMPOTRADO

ø6.0mm c/15
EMPOTRADO

10/01/2017. VERSION 01
67 DE 106
MEMORIAS DE CÁLCULO

14.6. DISEÑO DE PLACA MACIZA ENTREPISO

PROYECTO EDIFICIO VIS MANI


DISEÑO PLACA MACIZA DE ENTREPISO

Materiales
Concreto 210 kg/cm²
Acero 4200 kg/cm²
Espesor adoptado: 0.10 m

Avalúo de Cargas: t / m²

Peso propio de placa 0.10 x 2.40 = 0.240


Muros = 0.000
Acabados = 0.110
CM = 0.350
Carga viva cubierta maciza
CV = 0.180
CR = 0.53 As minimo (cm²)= 1.80
CU = 1.2 CM + 1.6 CV CU = 0.71 b= 100 cm
d= 7 cm
h= 10 cm

Análisis Estructural y Diseño

Wu = 0.71 t/m²
2.70 3.10 3.10 2.70

Mu (t-m) - 0.57 0.57 0.57


Mu (t-m) + 0.37 0.43 0.49 0.37

Cuantía : 0.0020 0.0032 0.0024 0.0032 0.0027 0.0032 0.0020


As (cm²) 1.43 2.23 1.65 2.23 1.90 2.23 1.43
As minimo (cm²) 1.80 1.80 1.80 1.80 1.80 1.80 1.80
As requerido (cm²) 1.80 2.23 1.80 2.23 1.90 2.23 1.80

REFUERZO ø6.0mm c/15 ø7.0mm c/15 ø6.0mm c/15 ø7.0mm c/15 ø6.0mm c/15 ø7.0mm c/15 ø6.0mm c/15
As malla (cm²) 1.89 2.57 1.89 2.57 1.89 2.57 1.89
As faltante (cm²) 0.00 0.00 0.00 0.00 0.01 0.00 0.00
colocar grafil Ø6mm c/ #¡DIV/0!
colocar grafil Ø4mm c/ #¡DIV/0!

10/01/2017. VERSION 01
68 DE 106
MEMORIAS DE CÁLCULO

PROYECTO EDIFICIO VIS MANI


DISEÑO PLACA MACIZA DE ENTREPISO

Materiales
Concreto 210 kg/cm²
Acero 4200 kg/cm²
Espesor adoptado: 0.10 m

Avalúo de Cargas: t / m²

Peso propio de placa 0.10 x 2.40 = 0.240


Muros = 0.000
Acabados = 0.110
CM = 0.350
Carga viva cubierta maciza
CV = 0.180
CR = 0.53 As minimo (cm²)= 1.80
CU = 1.2 CM + 1.6 CV CU = 0.71 b= 100 cm
d= 7 cm
h= 10 cm

Análisis Estructural y Diseño

Wu = 0.71 t/m²
1.50 1.50 1.50 1.50

Mu (t-m) - 0.13 0.13 0.13


Mu (t-m) + 0.11 0.10 0.11 0.11

Cuantía : 0.0006 0.0007 0.0005 0.0007 0.0006 0.0007 0.0006


As (cm²) 0.43 0.51 0.38 0.51 0.43 0.51 0.43
As minimo (cm²) 1.80 1.80 1.80 1.80 1.80 1.80 1.80
As requerido (cm²) 1.80 1.80 1.80 1.80 1.80 1.80 1.80

REFUERZO ø6.0mm c/15 ø6.0mm c/15 ø6.0mm c/15 ø6.0mm c/15 ø6.0mm c/15 ø6.0mm c/15 ø6.0mm c/15
As malla (cm²) 1.89 1.89 1.89 1.89 1.89 1.89 1.89
As faltante (cm²) 0.00 0.00 0.00 0.00 0.00 0.00 0.00
colocar grafil Ø6mm c/ #¡DIV/0!
colocar grafil Ø4mm c/ #¡DIV/0!

10/01/2017. VERSION 01
69 DE 106
MEMORIAS DE CÁLCULO

PROYECTO EDIFICIO VIS MANI


DISEÑO PLACA MACIZA EN DOS DIRECCIONES CON VIGAS
NIVEL: ENTREPISO

f´c vigas= 21 Mpa Ln= 3.20 240


E vigas= 17872 Mpa KLn= 2.71 2.35
f´c losa= 21 MPa β= 1.18 OK
E losa= 17872 Mpa Iviga1= 0.00803 m4
Iviga2= 0.00008 m4
Viga1 Ilosa1= 0.00027 m4
B= 12 m Ilosa2= 0.00023 m4
H= 0.20 m
α1= 35.57 > 0.8 OK
Viga2 α2= 0.30 > 0.8 OK
B= 0.12 m αfm= 17.94
H= 0.20 m

Losa 1
B= 3.20 m
H= 0.100 m

Losa 2
B= 2.71 m
H= 0.100 m

Espesor sugerido: 0.075 m


Espesor adoptado: 0.10 m
Evaluacion de Cargas: t / m²

Peso propio de placa 0.10 x 2.40 = 0.240


Muros Internos = 0.000
Otras Cargas = 0.11
D= 0.350 0.5425
Carga Viva L= 0.180 0.279
CU = 0.708

SELECCIÓN TIPO DE APOYO

DEFINICIÓN DE LOS APOYOS


4
1 2 APOYO 1: 2 SIMPLE
KL APOYO 2: 2 SIMPLE
3 APOYO 3: 2 SIMPLE
L APOYO 4: 2 SIMPLE

10/01/2017. VERSION 01
70 DE 106
MEMORIAS DE CÁLCULO

DEFINICION DE VARIABLES

L= 3.20 m F.M.= 1.00 L = Longitud mayor


KL = 2.71 m Qu = 0.708 t / m² KL = Longitud menor
K= 0.850 f'c = 210 kg/cm²
h placa = 0.10 m f'y = 4200 kg/cm²
d' = 0.03 m

DATOS DE DISEÑO

0.03 0.00 0.00 0.06 0.00 0.00


Refuerzo del Refuerzo del
apoyo 1 al 2 APOYO 1 APOYO 2 apoyo 3 al 4 APOYO 3 APOYO 4
(Luz 1-2) (Luz 3-4)
M/qK2 L 2 o M/qL 2 0.0301 0.0000 0.0000 0.0648 0.0000 0.0000
M ( t-m ) 0.218 0.000 0.000 0.337 0.000 0.000
Cuantia r 0.00104 0.00000 0.00000 0.00162 0.00000 0.00000
Area Req(cm²/m) 0.78 0.00 0.00 1.21 0.00 0.00
Area Min.(cm²/m) 1.80 1.50 1.50 1.80 1.50 1.50
Area def. (cm²/m) 1.80 1.50 1.50 1.80 1.50 1.50
Refuerzo ø6.0mm c/15 ø5.5mm c/15 ø5.5mm c/15 ø6.0mm c/15 ø5.5mm c/15 ø5.5mm c/15

SIMPLE L= 3.20
ø5.5mm c/15
ø6.0mm c/15

KL= 2.71 ø5.5mm c/15 ø6.0mm c/15 ø5.5mm c/15

SIMPLE SIMPLE

ø5.5mm c/15
SIMPLE

10/01/2017. VERSION 01
71 DE 106
MEMORIAS DE CÁLCULO

PROYECTO EDIFICIO VIS MANI


PLACA MACIZA

Materiales
Concreto 240 kg/cm²
Acero 4200 kg/cm²
Espesor adoptado: 0.10 m

Avalúo de Cargas: t / m²

Peso propio de placa 0.10 x 2.40 = 0.240


Otras Cargas = 0.110
Tanque = 0.000
CM = 0.350
CV = 0.180
CR = 0.53 As minimo (cm²)= 1.80
CU = 1.2 CM + 1.6 CV CU = 0.71 b= 100 cm
d= 6 cm
h= 10 cm

Análisis Estructural y Diseño

Wu = 0.71 t/m²
1.15

Mu (t-m) -
Mu (t-m) + 0.47

Cuantía : 0.0036
As (cm²) 2.14
As minimo (cm²) 1.08 ø5.0mm c/15
As requerido (cm²) 2.14

REFUERZO ø6.5mm c/15


As malla (cm²) 2.21
As faltante (cm²) 0.00
colocar grafil Ø6mm c/ #¡DIV/0!
colocar grafil Ø4mm c/ #¡DIV/0!

10/01/2017. VERSION 01
72 DE 106
MEMORIAS DE CÁLCULO

14.7. DISEÑO DE PLACA MACIZA TANQUE


PROYECTO EDIFICIO VIS MANI
PLACA MACIZA

Materiales
Concreto 240 kg/cm²
Acero 4200 kg/cm²
Espesor adoptado: 0.10 m

Avalúo de Cargas: t / m²

Peso propio de placa 0.10 x 2.40 = 0.240


Otras Cargas = 0.020
Tanque = 0.257
CM = 0.517
CV = 0.180
CR = 0.70 As minimo (cm²)= 1.80
CU = 1.2 CM + 1.6 CV CU = 0.91 b= 100 cm
d= 6 cm
h= 10 cm

Análisis Estructural y Diseño

Wu = 0.91 t/m²
1

Mu (t-m) -
Mu (t-m) + 0.45

Cuantía : 0.0035
As (cm²) 2.08
As minimo (cm²) 1.08 ø5.0mm c/15
As requerido (cm²) 2.08

REFUERZO ø6.5mm c/15


As malla (cm²) 2.21
As faltante (cm²) 0.00
colocar grafil Ø6mm c/ #¡DIV/0!
colocar grafil Ø4mm c/ #¡DIV/0!

10/01/2017. VERSION 01
73 DE 106
MEMORIAS DE CÁLCULO

14.8. DISEÑO DE ESCALERA

10/01/2017. VERSION 01
74 DE 106
MEMORIAS DE CÁLCULO

10/01/2017. VERSION 01
75 DE 106
MEMORIAS DE CÁLCULO

14.9. REACCIONES EN LA BASE

10/01/2017. VERSION 01
76 DE 106
MEMORIAS DE CÁLCULO

10/01/2017. VERSION 01
77 DE 106
MEMORIAS DE CÁLCULO

10/01/2017. VERSION 01
78 DE 106
MEMORIAS DE CÁLCULO

10/01/2017. VERSION 01
79 DE 106
MEMORIAS DE CÁLCULO

10/01/2017. VERSION 01
80 DE 106
MEMORIAS DE CÁLCULO

10/01/2017. VERSION 01
81 DE 106
MEMORIAS DE CÁLCULO

10/01/2017. VERSION 01
82 DE 106
MEMORIAS DE CÁLCULO

10/01/2017. VERSION 01
83 DE 106
MEMORIAS DE CÁLCULO

10/01/2017. VERSION 01
84 DE 106
MEMORIAS DE CÁLCULO

10/01/2017. VERSION 01
85 DE 106
MEMORIAS DE CÁLCULO

10/01/2017. VERSION 01
86 DE 106
MEMORIAS DE CÁLCULO

10/01/2017. VERSION 01
87 DE 106
MEMORIAS DE CÁLCULO

10/01/2017. VERSION 01
88 DE 106
MEMORIAS DE CÁLCULO

10/01/2017. VERSION 01
89 DE 106
MEMORIAS DE CÁLCULO

10/01/2017. VERSION 01
90 DE 106
MEMORIAS DE CÁLCULO

10/01/2017. VERSION 01
91 DE 106
MEMORIAS DE CÁLCULO

10/01/2017. VERSION 01
92 DE 106
MEMORIAS DE CÁLCULO

10/01/2017. VERSION 01
93 DE 106
MEMORIAS DE CÁLCULO

10/01/2017. VERSION 01
94 DE 106
MEMORIAS DE CÁLCULO

10/01/2017. VERSION 01
95 DE 106
MEMORIAS DE CÁLCULO

10/01/2017. VERSION 01
96 DE 106
MEMORIAS DE CÁLCULO

10/01/2017. VERSION 01
97 DE 106
MEMORIAS DE CÁLCULO

10/01/2017. VERSION 01
98 DE 106
MEMORIAS DE CÁLCULO

10/01/2017. VERSION 01
99 DE 106
MEMORIAS DE CÁLCULO

10/01/2017. VERSION 01
100 DE 106
MEMORIAS DE CÁLCULO

10/01/2017. VERSION 01
101 DE 106
MEMORIAS DE CÁLCULO

14.10. DISEÑO DE ELEMENTOS NO ESTRUCTURALES


ELEMENTOS NO ESTRUCTURALES

Sa = Valor del espectro de aceleraciones de diseño para un periodo de vibración dado.


Vs = Cortante sísmico en la base
Aa = Coeficiente de aceleración pico efectiva
g= Gravedad
As= Aceleracion Maxima correspondiente a un T=0
M= Masa total de la edificación
hx= Altura en metros medida desde la base, del nivel del apoyo del elemento no estructural
heq= altura equivalente del sistema de un grado de libertad que simula la edificacion
ax = Aceleración horizontal que ocurre en el punto donde el elemento no estructural está soportado.
L= Longitud del elemento no estructural
E= Fuerzas sismicas reducidad de diseño (E=Fp/Rp)
H= Altura del elemento no estructural
W= Densidad de la mampostería
Mp = Masa de elemento no estructural
ap = Coeficiente de amplificación dinámica del elemento no estructural
Rp = Coeficiente de capacidad de disipación de energía del elemento no estructural
Fp = fuerza sísmica horizontal sobre el elemento no estructural (A.9-2)
Mdis = momento de diseño

1. Datos del análisis sísmico de la estructura:

Aa = 0.10 Ta = 0.27 seg


As= 0.25 Sa = 0.63 Grupo de Uso= I
I= 1.00 Vs = 218 ton
g= 9.80 Fa = 2.50

Grado de disipación de energía: DMO

Número de pisos: 3

2. Materiales
Concreto 210 kg/cm2
Mamposteria 90 kg/cm2
Acero 4200 kg/cm2

Grado de Desempeño Elementos no Estructurales: Bajo

Aceleraciones según NSR - 10

Aceleraciones según ASCE7-10

heq (m) 5.85 m

10/01/2017. VERSION 01
102 DE 106
MEMORIAS DE CÁLCULO

NSR - 10 ASCE7-10 RCB


Nivel h (m) hx (m) hx/heq(m) ax ax ax ax
3 2.60 7.80 1.33 0.756666667 0.84 0.75 0.672
2 2.60 5.20 0.89 0.587777778 0.56 0.58 0.476
1 2.60 2.60 0.44 0.418888889 0.28 0.42 0.363

2. Amplificación dinámica del elemento no estructural


(se determina de las Tablas A.9.5.1 de la NSR-10)
ap = 2.50 Considerando el caso en que la mampostería esta solo anclada abajo

3. Capacidad de disipación de energía en el rango inelástico del elemento no estructural


(se determina de las Tablas A.9.5.1 de la NSR-10)
Rp = 3.00 Anclajes Dúctiles

4. Fuerzas Sismicas Horizontales de Diseño

≥ ≈ 0.12

Espesor del muro: 0.15 m


Carga por m2: 0.25 kN/m2 Tabla B.3.4.2-4

Nivel Fp (kN/m 2) E (kN/m 2) Mp (kN-m) Vp (kN) S col (m) Mdis (kN-m) b (cm) d (cm) r As (cm2) F Vc (cm2)
3 1.715 0.5716667 1.932233333 1.5 4.00 7.728933333 15 10 0.0013857 0.21 27.71
2 1.200046296 0.4000154 1.35205216 1.0 4.00 5.408208642 15 10 0.0009648 0.14 27.71
1 0.855231481 0.2850772 0.963560802 0.7 4.00 3.85424321 15 10 0.0006853 0.10 27.71

10/01/2017. VERSION 01
103 DE 106
MEMORIAS DE CÁLCULO

Villavicencio, 26 de Diciembre de 2017

Señores:
CURADURIA URBANA DE VILLAVICENCIO
La Ciudad,

MEMORIAL DE RESPONSABILIDAD

Yo, RAFAEL EDUARDO COMAS MEJIA, Ingeniero Civil con matricula


profesional #2520283443CND, e identificado con CC. 86.053.648 de
Villavicencio, Certifico que avalo, en calidad de ingeniero consultor el
estudio estructural de:

Proyecto: PROYECTO VIVIENDA DE INTERES SOCIAL – TIPO 2


Estructura: Muros de mampostería parcialmente reforzada de bloque de
perforación vertical
Departamento: Mani – Casanare
Declaro que este estudio, se desarrolló de acuerdo con las normas sismo
resistentes vigentes del país NSR – 10 expedido por medio del Decreto 926
del 19 de Marzo de 2010 y modificado por el decreto 092 del 17 de Enero de
2011.
Aclaro que hago el aval del estudio realizado, siempre y cuando en la etapa
de construcción se sigan y se hayan seguido todas y cada una de las
especificación y recomendaciones, suscritas en el mismo.
Cordialmente,

Rafael Eduardo Comas Mejía


Ingeniero Civil
M.P. #25202 83443

10/01/2017. VERSION 01
104 DE 106
MEMORIAS DE CÁLCULO

10/01/2017. VERSION 01
105 DE 106
MEMORIAS DE CÁLCULO

10/01/2017. VERSION 01
106 DE 106

You might also like