8-2E-15 MDMT Calculation

Design Conditions:

CET: -42oF

Shell Side Tube Side Bundle Floating Head


Design P, psig 210 150
Design T, oF 300 300
CA 1/8” CLAD 1/8”
Service Lean Sponge Oil Cooling Water
Code of Construction ASME Sect VIII Div-1 (2001 Ed, ASME Sect VIII Div-1(1971) &
2003 Addenda) & TEMA ‘R’ TEMA ‘R’
NDE SPOT RT, E =0.85 -Fig. UW-3 SPOT RT E=0.8, all long and girth
Cat. ‘A’ joints seam welds
E= 1 for Head
PWHT None Channel & Floating Head
Manufacturer Edmonton Exchanger (2005) MLW (1978) MLW (1978)

Shell Side

Component Material Nominal Thickness P.No Impact Test Figure UCS-66 Governing
exclusive of CA Thickness
Ellipsoidal Head SA-516-70N 0.375” 1 N Curve D
Shell SA-516-70N 0.375” 1 N Curve D
Shell Body Flange SA-350 LF2 CL.1 4.1875” 1 Y, -50oF
N3/N4 Re-pad SA-516-70N 0.25” 1 N Curve D
N3/N4 Pipe SA-333 Gr.6 0.432” 1 Y, -50oF
N3/N4 Flange SA-350 LF2 CL.1 1.44” 1 Y, -50oF
Saddle Wear Plate SA-516-70N 0.375” 1 N Curve D
Saddle Flange SA-516-70N 0.5” 1 N Curve D
Saddle Web SA-516-70N 0.375” 1 N Curve D
Saddle Base SA-516-70N 0.75” 1 N Curve D
NOTES:

1. UG-20(f) does not apply as site CET is lower than -20oF.