You are on page 1of 1

S.NO.

NOTES :-

1. All dimensions are in millimetres unless where ever specified. Diameter of the bars
are shown in mm.
CHART SHOWING DETAIL OF ISOLATED FOOTING REINFORCEMENT. 2. Dimensions are not to be scaled out, only written dimensions may be taken as
correct.
3 Though every care has been taken while preparing this drawing , however if any
discrepancy noticed, shall be brought into notice of this office immediately for further
Sr. NAME OF SIZE OF SIZE OF SIZE OF SIZE OF HEIGHT OF THICKNESS OF d-eff. THICKNESS EQUALLY SPACED EQUALLY SPACED PEDESTAL DEPTH OF CONC. clarification.
NO COLUMN. COLUMN. PEDESTAL. FOOTING PIT PEDESTAL FOOTING OF FOOTING REINFORCEMENT REINFORCEMENT REINF. FONDATION MIX. 4 Safe bearing capacity for design has been taken as 18 T/ sq.m as intimated by E.E.
(bxd) (b1xd1) (BXD) (B1XD1) T1 T2 AT EDGE PARALLEL TO y-y PARALLEL TO x-x Chamba vide his letter No.PWD-DB- Police/2018-19-1524 on Dated 08-06-2018.
T3 (Df)
The bearing capacity must be ensured at founding level of each column at site.
1. D1,D6,A3,A4 400X400 500X500 1300x1300 1400x1400 700 250 350 200 6 NOS- 12O 6 NOS- 12O 6-16O 1500 M-20 5 The reinforcement shall be of High Strength Deformed Steel bars conforming to
IS:1786.
6 Minimum clear cover to the reinforcement including stirrups :-
2. D2,D5 400X400 500X500 1600x1600 1700x1700 650 300 450 200 9 NOS- 12O 9 NOS- 12O 6-16O 1500 M-20 (i) Beam : 25mm
(ii) Column : 40mm
(iii) Slab : 20mm
3. D3,D4 400X400 500X500 1500x1500 1600x1600 650 300 400 200 7 NOS- 12O 7 NOS- 12O 6-16O 1500 M-20 (iv) Footing : 50mm
And in any case shall not be less than the diameter of the bar.
7 Lap lenth and development lenth (Ld) shall be taken as
(i) 48 x dia. of bar . (in tension)
(ii) 38 x dia. of bar . (in compression )

8 The concrete shall be mechanically mixed and vibrated with water cement ratio not
exceeding 0.55.
9 Sample from fresh concrete shall be taken as per IS: 1189 and cubes shall be casted,
cured and tested in accordance with IS: 516.
Y 10 . Not more then 50% of bars shall be lapped at a particular section of the beam.
11. Refer drawing no. S.E.(D)/BLDGS./86-1 for detail of standards for earth quake
resistant building.

50
12. Grade of concrete M-20.
P.L. 13. Grade of steel Fe-415.
450

G.L
400 150

COLUMN REINFORCEMENT
TIE BEAM. REFER SEPARATE DRG. b1 HIMACHAL PRADESH
50 50 50 b 50 PUBLIC WORKS DEPARTMENT
PEDESTAL

50
REINF. C/O OFFICE BUILDING FOR CID WING IN POLICE LINE CHAMBA (H.P.)
A A d-eff X
PEDESTAL
X
T1

O/O SUPERINTENDING ENGINEER, 7TH CIRCLE, DALHOUSIE, HPPWD


D1

10O TRANSVERSE

d1
REINF. COL. OUTER LINE
D

d
REINFORCEMENT@150 C/C. d-eff TRANSVERSE
REINFORCEMENT
Df

SIDE COVER DRG. NO. :- PW / SE VII / BUILDING / 2018-19 /


10O @ 15 C/C.

50
50 SIDE
FOR COLUMN
COVER

d-eff
50 PEDESTAL REINFORCEMENT DATE OF ISSUE
REINF. REFER SEPARATE
DRAWING
T2

SCALE NOT TO SCALE DETAIL OF ISOLATED


FOOTING REINFORCEMENT
Ld
T3

LEAN CONC.
(1: 4: 8)
100

50

LEAN CONC. DRAWN BY :-


(1: 4: 8) 50 50
50 B 50 B
ER. KANUPRIYA BHALLA
B1 B1 G.J.E. (D)

DESIGNED BY:- CHECKED BY:- APPROVED BY:-


REINFORCEMENT
PARALLEL TO Y-Y
REINFORCEMENT
PARALLEL TO X-X
Y

TYPICAL X- SECTION PLAN (VIEW AT A-A.)


AT X-X . DETAIL OF ISOLATED FOOTING.
ER. R.K. VERMA ER. SUDHIR MITTAL ER. J.S. GULERIA
A.E. (D) E.E. (D) S.E.