You are on page 1of 6

sm electrics

Dead Man Alarm le guardian 2025

operating device LOD 222.24.0.0, 144x72mm

designed
for
retrofit

connecting module
LCM 210.24.0.0
over 5000
installations

 easy and comfortable use


 simple connections to all peripheral equipment
 easy to install - vessel crew / shipyard personnel installed the
vast bulk of systems
 intuitive system control - rotary encoder allows simple check of
all connected devices and settings
 type approved acc. to latest International Standard
 extensive BNWAS experience - first Type Approval awarded in
2005

safety on board
sm electrics
D M A l e g u a r d i a n 2025
sample system for standard vessels / platforms
Chief 1st Eng. 2nd Eng. Mess Room

OFFICER‘s AREA

Existing XASystem (via IMCS)


Stage #2 Alarm

Operating Device
ENGINE CONTROL
ROOM

Connecting
Module

INSIDE CONSOLE

failure to
24VDC
IMCS

Reset & Alarm Release

Remote Start/Stop Remote Start/Stop


ER Entrance ER Entrance

ENGINE ROOM Existing LSASystem


PRE-ALARM & STAGE #1

safety on board
sm electrics
D M A l e g u a r d i a n 2025
sample system for standard vessels / platforms
Chief 1st Eng. 2nd Eng. Mess Room

OFFICER‘s AREA

Stage #2 Alarm Cabin Panels

Operating Device
ENGINE CONTROL
ROOM

Connecting
Module

INSIDE CONSOLE

failure to
24VDC
IMCS

Reset & Alarm Release Pre-Alarm & Stage #1

Remote Start/Stop Remote Start/Stop


ER Entrance ER Entrance

ENGINE ROOM

safety on board
sm electrics
D M A l e g u a r d i a n 2025
sample system for small sized vessels (tug boats)

BRIDGE AREA
Operating Device

Connecting
Module

INSIDE CONSOLE

failure to
24VDC
IMCS

ENGINE ROOM

Reset & Alarm


Release

safety on board
sm electrics
Dead Man Alarm le guardian 2025

Light Signal Device


LSD 309.7.3.1

visual pre-alarm & audible stage #1 alarm

• The audible & visual alarm to reach the ER watch keeper can be
transferred via existing light signal columns, saving additional engine
room alarm devices

• sm electrics‘ scope of supply does cover modern and reliable light


signal alarm systems (LSAS) for engine room as well.

DEAD MAN ALARM time table


VISUAL / AUDIBLE 1
STAGE #2 ALARM
OFFICER‘s AREA 0
t [sec]
5 10 15 20 25 30 60 90 120 150 180 210

AUDIBLE 1
Summarised VISUAL PRE-ALARM
STAGE #1 ALARM & AUDIBLE STAGE #1 ALARM limited to 3 min.
ENGINE ROOM 0
t [sec]
5 10 15 20 25 30 60 90 120 150 180 210

VISUAL 1
PRE-ALARM
ENGINE ROOM 0
t [sec]
5 10 15 20 25 30 60 90 120 150 180 210

VISUAL 1
PRE- ALARM
RESET UNITS 0
t [sec]
3… 27 min 5 10 15 20 25 30 60 90 120 150 180 210
START: 1 min. before MAIN PERIODE is over
SELECTED
MAIN PERIOD

safety on board
sm electrics
periphery equipment

system‘s remote reset unit in wall box reset unit in wall box reset unit w. buzzer
start/stop pre-alarm indication pre-alarm indication pre-alarm & alarm stage #1
engine room entrances engine room engine room engine room
WAP 220.3.0.0 WAR 222.2.0.0 WAR 222.2.0.0 A WAR 222.2.1.0

extension sounder alarm stage #2 panel alarm stage #2 panel alarm stage #1 / #2 panel
alarm stage #1 flush mounted bulkhead mounted flush or bulkhead mounted
ECR area officer‘s cabin officer‘s cabin ER & officer‘s public area
WAB 220.2.0.0 WAP 222.2.0.0 WAP 222.5.0.0 WAP 222.4.0.0

wall box to cover desk / wall / ceiling swivel bracket


1x LCM connecting module for operating device
relays & terminals (if required) ECR area
WBC 210.1.0.0 WBC 210.1.0.0

TECHNICAL DATA & FEATURES

 key-switch for lock / unlock  integrated buzzer, eight individual sound


 2 x 16 character blue light display shows all relevant characteristics & volume adjustment
device and alarm states  system voltage: 24VDC nominal (18… 31,2V)
 rotary encoder with integrated push button - simple  connecting module designed for TS 35 terminal rail
and effective for user  emergency call facility (manual release from ER)

DMA-991040-20140823-1

sm electrics GmbH | Am Wulfsbarg 17 | 24217 Stakendorf | Germany


 +49 (0) 4344 819 23-10 |  info@sm-electrics.de | www.sm-electrics.de