You are on page 1of 17
‘National Accreditation Board for Testing and Calibration Laboratories Department of Science & Technology, India CERTIFICATE OF ACCREDITATION GALIBRATION & STANDARDS LABORATORY, CONTROLLERATE OF QUALITY ASSURANCE (ELECTRONICS) has been assessed and accredited in accordance with the standard ISOMEC 17025:2005 Requirements for the Competence of Testing &alaton Laboratories” for its facilities at JC Nagar Post, Bangalore, Kamataka inthe discipline of ELECTRO-TECHNICAL CALIBRATION (To 200 the scope of scoredtation ofthis laboratory, you may also vsk NABL website www.nablincia.ra) Certificate Number C-0838 Issue Date 30/07/2014 ‘Valid Until 29/07/2016 This certificate remains valid for the Scope of Accreditation as specified in the annexure subject to continued satisfactory compliance to the above standard & the additional requirements of NABL. Signed for and on behalf of NABL Ese (ese A Avijit Das Anil Relia rof. K. VijayRaghavan Program Manager Director Chairman Tae eae) pat Faas AT se am. 2005 ue m6 FTE Ta AA pt sien fage caatat sisters dim &ifaa (ge setereren & aT Rr Ba A one OF at ee BATE woncnablindleor A Mt are we ee B) T= GT F-0838 watt wer a fafa 30/07/2014 Bear a fae 29/07/2016 ae Ta res ear Ter atten sire sister atraren TeUETT aS St safe aTteTsHT at Prk Marae agaTOTT Fe aT Ie ary H Pakage sere + das Ferg Se eT TATA, a ate a eee Department of Science & Technology. India SCOPE OF ACCREDITATION Calibration & Standards Laboratory, Controllerate of Quality Assurance (Electronics), JC Nagar Post, Bangalore, Karnataka Accreditation Standard ISO/IEC 17025:2005 Discipline Electro-Technical Calibration Issue Date 30.07.2014 Certificate Number C-0838 Valid Until 29.07.2016 Last Amended on - Page 10f5 ‘Quantity Measured? Range/ Frequency “Calibration Measurement Instrument Capability (+) ———SSeeeeeeeehFhFhkhFhFhe SOURCE® 1. DC Voltage ImV to 100mV 0.047% to 0.0014% Using FlukeS720A 100 mV to 1'V 0.0014% to 0.0007% By Direct Method 1Vt010V 0.007% to 0.005% 10.V to 1000 V 0,0005% to 0.008% 10 pA to 100 pA 0.051% to 0.012% Using FlukeS720A 100 pA to 1mA. 0.012% to 0.005% By Direct Method mA to 10mA 0.005% to 0.0045% 10mA to 100 mA 10,0045% to 0.006% 100 mA to 1A 0,006% t0 0.011% 1A to 2A 0.011% t0 0.010% 2A.t0 100A 0.010% to 0.047%, Using Multi Function = calibrator, Fluke 5720 , ‘Trans conductance ‘Amplifier, DMM/ Keithley 2002, Std Resistor L & N 0.000182 by Indirect Method 3. AC Voltage < 20 Hz t0 40 Bz 20 mV to 20 V 0.058% 10 0.031% Using FlukeS720A bby Direct Method 40 Fiz to 1 Bz Z 2mVt020mV.__-.._.0.61%100.036% 20 mV to 200 mV 0.036% to 0.017% 200 mV to2V 0.017% 10 0.013% 2vi0200¥ oor Ww e Avijit Das aces, Program Manager

You might also like